85136K3 Performance Floodlight
Application
Performance floodlight with mounting box.
For a variety of interior and exterior lighting applications.
**Product description
**
Luminaire made of aluminium alloy, aluminium and stainless steel
BEGA Unidure® coating technology
Colour graphite or silver
Clear safety glass
Silicone gasket
Reflector surface made of pure aluminium
BEGA Hybrid Optics®
Rotation range of floodlight 350°
Swivel range -30°/+80°
Mounting box with 2 fixing holes
ø 4.8 mm · 35 mm spacing
1 cable entry for mains supply cable up to ø 10,5 mm
Connecting terminals 2.5◻
Earth conductor connection
BEGA Ultimate Driver®
Complies with flicker requirements in accordance with IEEE 1789,
DIN IEC/TR 63158, DIN IEC/TR 61547-1
LED power supply unit
220-240 V ≂ 0/50-60 Hz
DC 176-280 V
Safety class I
Protection class IP 65
Dust-tight and protection against water jets
Impact strength IK07
Protection against mechanical impacts < 2 joule
– Conformity mark
Wind catching area: 0.01 m²
This product contains light sources of energy efficiency class(es) D
Lighting technology
Symmetrical wide beam light distribution
Half beam angle 48°
For special lighting applications, an optical filter can be used to change the
symmetrical light cone into a flat beam light distribution.
Lamp
Module connected wattage | 8.4 W |
---|---|
Luminaire connected wattage | 9.6 W |
Rated temperature | ta = 25 °C |
Ambient temperature | t a max = 50 °C |
85 136 K3
Module designation | LED-1269/930 |
---|---|
Colour temperature | 3000 K |
Colour rendering index | CRI > 90 |
Module luminous flux | 1265 lm |
Luminaire luminous flux | 918 lm |
Luminaire luminous efficiency | 95,6 lm / W |
85 136 K4
Module designation | LED-1269/940 |
---|---|
Colour temperature | 4000 K |
Colour rendering index | CRI > 90 |
Module luminous flux | 1330 lm |
Luminaire luminous flux | 965 lm |
Luminaire luminous efficiency | 100,5 lm / W |
Safety
The installation and operation of this luminaire are subject to national
safety regulations.
Installation and commissioning may only be carried out by a qualified
electrician.
The manufacturer accepts no liability for damage caused by improper use or
installation.
If subsequent modifications are made to the luminaire, the person responsible
for these modifications shall be considered the manufacturer.
Overvoltage protection
The electronic components installed in the luminaire are protected against
overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e. g. transients, etc. we
recommend separate overvoltage protection components.
You can find them on our website at www.bega.com.
The ideal protection of all electronic components installed in the luminaires
is achieved by using bounce-free switching contacts such as an electronic
relay (solid-state relay), e.g. BEGA 71 320.
Installation
LED are high-quality electronic components!
Please avoid touching the light output opening of the LED directly during
installation or relamping.
Undo hexagon socket head screw (wrench size 3 mm) up to the stop and
disassemble the mounting plate.
Pass the power connecting cable through the cable entry in the mounting plate.
Note position of application of the mounting plate “arrow down”.
Fix the mounting plate with enclosed or any other suitable fixing material
onto the mounting surface.
Be sure to use the gasket rings supplied.
Make earth conductor connection.
Push silicone sleeves over the lines and make electrical connection.
Connect the floodlight unit’s green and yellow protective earth conductor to
the terminal marked ****in the mounting plate.
Make sure that gasket is positioned correctly.
Place floodlight unit onto the mounting plate as displayed in the sketch,
align and screw together firmly.
Adjustment of beam direction:
Undo joint screw (hexagon socket head wrench size 3 mm) and set the desired
beam direction.
Tighten the joint screw.
Torque = 2.5 Nm.
Cleaning · Maintenance
Clean luminaire regularly with solvent-free cleansers from dirt and deposits.
Do not use high pressure cleaners.
Maintenance
The connecting cable between mounting box and floodlight has to be inspected
regarding obvious damages and has to be replaced by a qualified electrician
only.
Please note:
Do not remove the desiccant bag from the luminaire housing.
It is needed to remove residual moisture.
Replacing the LED module
The designation of the LED module is noted on a separate label in the
luminaire or on the underside of the specific LED module.
The light colour and light output of BEGA replacement modules correspond to
those of the modules originally fitted. The replacement can be carried out by
a qualified person using standard tools.
Disconnect the system from the power supply.
Open the floodlight:
Remove the trim ring along with the safety glass and reflector by twisting it
anti-clockwise. Replace LED module.
Please follow the installation instructions for the LED module.
Inspect and, if necessary, replace the luminaire gaskets.
Defective glass must be replaced.
Place the trim ring with glass and reflector on the floodlight housing so that
the notches in the trim ring and luminaire housing sit on top of each other.
Twist on the trim ring clockwise as far as the stop.
Accessories
71 288 | Optical filter flat beam |
---|---|
71 330 | Shield |
71 335 | Cylindrical shield |
For the accessories a separate instructions for use can be provided upon request.
Spares
Trim ring graphite with glass | 25 000 271 |
---|---|
Trim ring silver with glass | 25 000 272 |
LED power supply unit | DEV-0447/250 |
LED module 3000 K | LED-1269/930 |
LED module 4000 K | LED-1269/940 |
Reflector | 75 005 133 |
Gasket mounting box | 83 000 659 |
Gasket housing 2x | 83 002 045 |
BEGA Gantenbrink-Leuchten KG
Postfach 31 60
58689 Menden
info@bega.com
www.bega.com
Documents / Resources
| BEGA
85136K3 Performance
Floodlight
[pdf] Instruction Manual
85136K3, 85136K3 Performance Floodlight, Performance Floodlight, Floodlight
---|---
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>