BEGA 85136K3 Performance Floodlight Instruction Manual

June 1, 2024
BEGA

Technical amendments reserved
Performance floodlight
IP 65
Instructions for use

85136K3 Performance Floodlight

BEGA 85136K3 Performance Floodlight

Application
Performance floodlight with mounting box.
For a variety of interior and exterior lighting applications.

**Product description

**

Luminaire made of aluminium alloy, aluminium and stainless steel
BEGA Unidure® coating technology
Colour graphite or silver
Clear safety glass
Silicone gasket
Reflector surface made of pure aluminium
BEGA Hybrid Optics®
Rotation range of floodlight 350°
Swivel range -30°/+80°
Mounting box with 2 fixing holes
ø 4.8 mm · 35 mm spacing
1 cable entry for mains supply cable up to ø 10,5 mm
Connecting terminals 2.5◻
Earth conductor connection
BEGA Ultimate Driver®
Complies with flicker requirements in accordance with IEEE 1789,
DIN IEC/TR 63158, DIN IEC/TR 61547-1
LED power supply unit
220-240 V ≂ 0/50-60 Hz
DC 176-280 V
Safety class I
Protection class IP 65
Dust-tight and protection against water jets
Impact strength IK07
Protection against mechanical impacts < 2 joule
– Conformity mark
Wind catching area: 0.01 m²
This product contains light sources of energy efficiency class(es) D

Lighting technology
Symmetrical wide beam light distribution
Half beam angle 48°
For special lighting applications, an optical filter can be used to change the symmetrical light cone into a flat beam light distribution.

Lamp

Module connected wattage 8.4 W
Luminaire connected wattage 9.6 W
Rated temperature ta = 25 °C
Ambient temperature t a max = 50 °C

85 136 K3

Module designation LED-1269/930
Colour temperature 3000 K
Colour rendering index CRI > 90
Module luminous flux 1265 lm
Luminaire luminous flux 918 lm
Luminaire luminous efficiency 95,6 lm / W

85 136 K4

Module designation LED-1269/940
Colour temperature 4000 K
Colour rendering index CRI > 90
Module luminous flux 1330 lm
Luminaire luminous flux 965 lm
Luminaire luminous efficiency 100,5 lm / W

Safety

The installation and operation of this luminaire are subject to national safety regulations.
Installation and commissioning may only be carried out by a qualified electrician.
The manufacturer accepts no liability for damage caused by improper use or installation.
If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Overvoltage protection

The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e. g. transients, etc. we recommend separate overvoltage protection components.
You can find them on our website at www.bega.com.
The ideal protection of all electronic components installed in the luminaires is achieved by using bounce-free switching contacts such as an electronic relay (solid-state relay), e.g. BEGA 71 320.

Installation

LED are high-quality electronic components!
Please avoid touching the light output opening of the LED directly during installation or relamping.
Undo hexagon socket head screw (wrench size 3 mm) up to the stop and disassemble the mounting plate.
Pass the power connecting cable through the cable entry in the mounting plate.
Note position of application of the mounting plate “arrow down”.
Fix the mounting plate with enclosed or any other suitable fixing material onto the mounting surface.
Be sure to use the gasket rings supplied.
Make earth conductor connection.
Push silicone sleeves over the lines and make electrical connection.
Connect the floodlight unit’s green and yellow protective earth conductor to the terminal marked ****in the mounting plate.
Make sure that gasket is positioned correctly.

BEGA 85136K3 Performance Floodlight 2

Place floodlight unit onto the mounting plate as displayed in the sketch, align and screw together firmly.
Adjustment of beam direction:
Undo joint screw (hexagon socket head wrench size 3 mm) and set the desired beam direction.
Tighten the joint screw.
Torque = 2.5 Nm.

Cleaning · Maintenance

Clean luminaire regularly with solvent-free cleansers from dirt and deposits.
Do not use high pressure cleaners.

Maintenance
The connecting cable between mounting box and floodlight has to be inspected regarding obvious damages and has to be replaced by a qualified electrician only.

Please note:
Do not remove the desiccant bag from the luminaire housing.
It is needed to remove residual moisture.
Replacing the LED module
The designation of the LED module is noted on a separate label in the luminaire or on the underside of the specific LED module.
The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted. The replacement can be carried out by a qualified person using standard tools.
Disconnect the system from the power supply.
Open the floodlight:
Remove the trim ring along with the safety glass and reflector by twisting it anti-clockwise. Replace LED module.
Please follow the installation instructions for the LED module.
Inspect and, if necessary, replace the luminaire gaskets.
Defective glass must be replaced.
Place the trim ring with glass and reflector on the floodlight housing so that the notches in the trim ring and luminaire housing sit on top of each other.
Twist on the trim ring clockwise as far as the stop.

Accessories

71 288 Optical filter flat beam
71 330 Shield
71 335 Cylindrical shield

For the accessories a separate instructions for use can be provided upon request.

Spares

Trim ring graphite with glass 25 000 271
Trim ring silver with glass 25 000 272
LED power supply unit DEV-0447/250
LED module 3000 K LED-1269/930
LED module 4000 K LED-1269/940
Reflector 75 005 133
Gasket mounting box 83 000 659
Gasket housing 2x 83 002 045

BEGA Gantenbrink-Leuchten KG
Postfach 31 60
58689 Menden
info@bega.com
www.bega.com

Documents / Resources

| BEGA 85136K3 Performance Floodlight [pdf] Instruction Manual
85136K3, 85136K3 Performance Floodlight, Performance Floodlight, Floodlight
---|---

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals