BEGA 85169A Performance Floodlight Instruction Manual

June 1, 2024
BEGA

BEGA 85169A Performance Floodlight

BEGA-85169A-Performance-Floodlight-PRO

Product Information

Specifications

  • Model: Leistungsscheinwerfer RGBW Performance floodlight RGBW
  • Luminaire connected wattage: 24 W
  • Colour temperature of the white LED: 4000 K
  • Luminaire luminous flux: 1297 lm
  • Luminaire luminous efficiency: 54 lm / W
  • Module designation: LED-1161/RGBW

Product Usage Instructions

Safety Instructions

  • The installation and operation of this luminaire must comply with national safety regulations.
  • Only a qualified electrician should carry out the installation and commissioning.
  • The manufacturer is not liable for damages resulting from improper use or installation.
  • Any modifications to the luminaire should be done by a qualified person.

Overvoltage Protection

  • The electronic components in the luminaire are protected against overvoltage as per DIN EN 61547.
  • For additional protection against transients, it is recommended to use separate overvoltage protection components available on the manufacturer’s website.

FAQ

Q: Can I replace the connecting cable myself?

A: No, the connecting cable must be replaced by a qualified electrician.

Q: What should I do if I notice external damage on the connecting cable?

A: Contact a qualified electrician for a thorough inspection and possible replacement of the damaged cable.

Q: Is it safe to operate the luminaire without overvoltage protection components?

A: It is recommended to use overvoltage protection components to ensure the safety and longevity of the electronic components in the luminaire.

Performance floodlight RGBW

BEGA-85169A-Performance-Floodlight-FIG-1

Dimensions

BEGA-85169A-Performance-Floodlight-FIG-2

Instructions for use

Application

  • Performance floodlight with G½ mounting bush.
  • The floodlight can be bolted together with any female thread G½ according to ISO 228 supplied by others or to BEGA accessories.
  • For a variety of interior and exterior lighting applications.
  • The floodlight can be controlled by DALI colour light control (DT8, RGBWAF, xy, TC).

Product Description

  • Luminaire made of aluminium alloy, aluminium and stainless steel BEGA Unidure® coating technology
  • Colour graphite or silver
  • Safety glass with optical structure
  • Silicone gasket
  • Reflector surface is made of pure aluminium
  • BEGA Constant Optics®
  • Rotation range of floodlight 350°
  • Swivel range -30°/+100°
  • Mounting bracket with G½ threaded connection
  • Thread length: 14 mm
  • Connecting cable X05BQ-F 5 G 1 mm²
  • Cable length 1 m
  • BEGA Ultimate Driver®
  • Complies with flicker requirements by IEEE 1789,
  • DIN IEC/TR 63158, DIN IEC/TR 61547-1
  • LED power supply unit 220-240 V 0/50-60 Hz
  • DC 176-264 V
  • DALI-controllable(DT8, RGBWAF, xy, TC)
  • Number of DALI addresses: 1
  • Basic insulation is provided between the mains and control cables
  • Safety class I
  • Protection class IP 65
  • Dust-tight and protection against water jets
  • Impact strength IK06
  • Protection against mechanical impacts < 1 joule
  • – Conformity mark
  • Wind catching area: 0.021 m²
  • This product contains light sources of energy efficiency class(es) F

Safety

  • The installation and operation of this luminaire are subject to national safety regulations.
  • Installation and commissioning may only be carried out by a qualified electrician.
  • The manufacturer accepts no liability for damage caused by improper use or installation.
  • If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Overvoltage protection

  • The electronic components installed in the luminaire are protected against overvoltage under DIN EN 61547.
  • To achieve additional protection against e. g. transients, etc. we recommend separate overvoltage protection components.
  • You can find them on our website at  www.bega.com.

Installation

  • Screw the floodlight G½ threaded connection firmly into the on-site G½ female thread or BEGA accessory.
  • G½ threaded connection torque = 40 Nm.
  • Secure the screw connection from loosening on site (if provided with locking screw S, see fig. A).
  • Check the earth conductor connection between the G½ threaded connection and the on-site G½ female thread.

Adjust floodlight

  • Undo the hexagon socket screw (wrench size 5 mm) and hexagon nut (wrench size 27 mm) and set the desired beam direction (see sketch B, C).

Torque

  • Hexagon socket screw = 7 Nm
  • Hexagon nut = 35 Nm
  • Secure bolted connection Gß against loosening by tightening the hexagon socket screws (wrench size 2 mm).

BEGA-85169A-Performance-Floodlight-FIG-5

  • The electrical connection must be carried out with matching protection class and safety class, strain-relieved, with suitable connection terminals (not included in the scope of delivery) at the luminaire power supply cable.
  • Note the correct configuration of the main supply cable. The earth conductor is connected at the green-yellow ( ), the phase to the brown (L), and the neutral conductor to the blue (N) marked wire.
  • The connection of the control cables is achieved through both leads marked with DALI. In case these leads are not used the luminaire will be operated at full light output.

Lamp

  • Module connected wattage 20.8 W
  • Luminaire connected wattage 24 W
  • Rated temperature ta = 25 °C
  • Service life criteria 50 000 h / L70
  • Module designation LED-1161/RGBW
  • Colour temperature of the white LED 4000 K
  • Luminaire luminous flux 1297 lm
  • Luminaire luminous efficiency 54 lm / W

Lighting technology

  • Symmetrical wide beam light distribution
  • Half beam angle 50°
  • For special lighting applications, an optical filter can be used to change the symmetrical light cone into a flat beam light distribution.

Cleaning Maintenance

  • Clean the luminaire regularly with solvent-free cleansers from dirt and deposits.
  • Do not use high-pressure cleaners.

Maintenance

  • The connecting cable must be checked for external damage and may only be replaced by a qualified electrician.

Please note

  • Do not remove the desiccant bag from the luminaire housing.
  • It is needed to remove residual moisture.

Replacing the LED module

  • The designation of the LED module is noted on a separate label in the luminaire or on the underside of the specific LED module.
  • The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted. The module can be replaced by qualified persons using standard tools.
  • Disconnect the system.
  • Open the floodlight:
  • Undo the locking pin (hexagon socket head wrench size 2.5 mm) on the back side of the floodlight housing.
  • Remove the trim ring along with the safety glass and reflector by twisting it counterclockwise.
  • Replace the LED module.
  • Please follow the installation instructions for the LED module.
  • Inspect and, if necessary, replace the luminaire gaskets.
  • Defective glass must be replaced.
  • Place the trim ring with glass and reflector on the floodlight housing in such a way that the notches in the trim ring and floodlight housing align on top to each other.
  • Twist on the trim ring clockwise as far as the stop. Tighten the locking pin.

Accessories

  • 71 290 Optical filter flat beam
  • 71 332 Shield
  • 71 337 Cylindrical shield
  • 70 214 Pole cap for pole ø 48 mm
  • 70 248 Pole cap for pole ø 60 mm
  • 70 245 Mounting box
  • 70 252 General fastener
  • 70 280 Tube clamp G½
  • 70 283 Screw clamp
  • 70 379 Cross beam G½
  • 70 889 Tension belt

For the accessories, separate instructions for use can be provided upon request.

Spares

  • Trim ring graphite with glass 25 000 279
  • Trim ring silver with glass 25 000 280
  • LED power supply unit DEV-0418/200i
  • LED module LED-1161/RGBW
  • Reflector 76 002 012
  • Gasket housing 83 000 521
  • Gasket trim ring 83 001 952