BEGA 85139 Performance Flood Light

Product Information

  • Specifications:
    • Product Name: Performance Floodlight
    • Model Number: 85 139
    • Lamp Module Connected Wattage: 36.8 W
    • Luminaire Connected Wattage: 40 W
    • Colour Temperature: 3000 K or 4000 K
    • Colour Rendering Index (CRI): > 90
    • Module Luminous Flux: 5145 lm – 5220 lm
    • Luminaire Luminous Flux: 3834 lm – 3890 lm
    • Luminaire Luminous Efficiency: 95.8 lm/W – 97.2 lm/W

Product Usage Instructions

  • Application:
    • The Performance Floodlight is suitable for a variety of interior and exterior lighting applications.
  • Safety:
    • Installation and operation must comply with national safety regulations.
    • Only a qualified electrician should perform installation and commissioning to avoid damage due to improper use or installation.
    • Any modifications made to the luminaire must be done by a qualified individual.
  • Overvoltage Protection:
    • The luminaire’s electronic components are protected against overvoltage according to DIN EN 61547.
    • Additional protection against transients is recommended through separate overvoltage protection components available on the manufacturer’s website.
  • Installation:
    • Handle LED components with care during installation to avoid direct contact with the light output opening.
    • Place the floodlight unit on the mounting plate as shown in the diagram, align it, and securely fasten it with screws.
    • To adjust the beam direction, loosen the joint screw using a 5 mm hexagon socket head wrench, set the desired direction, and then tighten the screw with a torque of 7 Nm.

FAQs

  • Q: Can I install the Performance Floodlight myself?
    • A: Installation and commissioning should only be carried out by a qualified electrician to ensure safety and proper functionality.
  • Q: What should I do if I need to modify the luminaire?
    • A: Any modifications to the luminaire should be performed by a qualified individual to avoid voiding the manufacturer’s liability.

Performance Floodlight

BEGA-85139-Performance-Flood-Light-FIG-1 \(1\)

Instructions for use

Application

  • Performance floodlight with mounting box.
  • For a variety of interior and exterior lighting applications.

Product Description

  • Luminaire made of aluminium alloy, aluminium and stainless steel
  • BEGA Unidure® coating technology
  • Colour graphite or silver
  • Clear safety glass
  • Silicone gasket
  • The reflector surface is made of pure aluminium
  • BEGA Hybrid Optics®
  • The rotation range of floodlight is 350°
  • Swivel range -25°/+90°
  • Mounting box with 2 fixing holes ø 4.8mm · 67mm spacing 2 cable entries for through-wiring of mains supply cable ø 7-10.5mm, max. 5G1.5@
  • Connecting terminal 2.5@ with plug connection
  • Earth conductor connection
  • BEGA Ultimate Driver®
  • Complies with flicker requirements by IEEE 1789,
  • DIN IEC/TR 63158, DIN IEC/TR 61547-1
  • LED power supply unit 220-240 V x 0/50-60 Hz
  • DC 176-264 V
  • DALI-controllable
  • Number of DALI addresses: 1
  • Basic insulation is provided between the mains and control cables
  • BEGA Thermal Control®
  • Temporary thermal regulation to protect temperature-sensitive components without switching off the luminaire
  • Safety class I
  • Protection class IP 65
  • Dust-tight and protection against water jets
  • Impact strength IK06
  • Protection against mechanical impacts < 1 joule c – Conformity mark
  • Wind catching area: 0.031 m²
  • Weight: 2.8 kg

This product contains light sources of energy efficiency class(es) E

Lighting technology

  • Symmetrical wide beam light distribution Half beam angle 54°
  • For special lighting applications, an optical filter can be used to change the symmetrical light cone into a flat beam light distribution.

Lamp

  • Module connected wattage 36.8 W
  • Luminaire connected wattage 40 W
  • Rated temperature ta=25 °C
  • Ambient temperature ta max=40 °C

85 139K3

  • Module designation LED-0780/930
  • Colour temperature 3000 K
  • Colour rendering index CRI >90
  • Module luminous flux 5145 lm
  • Luminaire luminous flux 3834 lm
  • Luminaire luminous efficiency 95,8 lm/W

85 139K4

  • Module designation LED-0780/940
  • Colour temperature 4000 K
  • Colour rendering index CRI >90
  • Module luminous flux 5220 lm
  • Luminaire luminous flux 3890 lm
  • Luminaire luminous efficiency 97,2 lm/W

Safety

  • The installation and operation of this luminaire are subject to national safety regulations.
  • Installation and commissioning may only be carried out by a qualified electrician.
  • The manufacturer accepts no liability for damage caused by improper use or installation.
  • If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Overvoltage protection

  • The electronic components installed in the luminaire are protected against overvoltage per DIN EN 61547.
  • To achieve additional protection against e.g. transients, etc. we recommend separate overvoltage protection components.
  • You can find them on our website at www.bega.com.
  • The ideal protection of all electronic components installed in the luminaires is achieved by using bounce-free switching contacts such as an electronic relay (solid-state relay), e.g. BEGA 71320.

Installation

LEDs are high-quality electronic components!

  • Please avoid touching the light output opening of the LED directly during installation or relamping.
  • Undo the hexagon socket head screw (wrench size 3mm) up to the stop and disassemble the mounting plate.
  • Pass the power connecting cable through the cable entry in the mounting plate.
  • Note the position of application of the mounting plate “arrow down”.
  • Fix the mounting plate with enclosed or any other suitable fixing material onto the mounting surface.
  • Be sure to use the gasket rings supplied.
  • Make an earth conductor connection.
  • Push silicone sleeves over the lines and make an electrical connection to the terminal (plug connection).
  • For digital control please use the 2-pole plug connector DA, DA.
  • In case this connector is not used the luminaire will be operated at full light output.
  • Push plug into the coupler as far as it will go.
  • Connect the floodlight unit’s green and yellow protective earth conductor to the terminal marked 1 in the mounting plate.
  • Make sure that the gasket is positioned correctly.BEGA-85139-Performance-Flood-Light-FIG-1 \(2\)
  • Place the floodlight unit onto the mounting plate as displayed in the sketch, and align and screw together firmly.

Adjustment of beam direction:

  • Undo the joint screw (hexagon socket head wrench size 5 mm) and set the desired beam direction.
  • Tighten the joint screw.
  • Torque = 7Nm.

Cleaning  Maintenance

  • Clean the luminaire regularly with solvent-free cleansers from dirt and deposits.
  • Do not use high-pressure cleaners.

Maintenance

  • The connecting cable between mounting box and the floodlight has to be inspected for obvious damages and has to be replaced by a qualified electrician only.

Please note:

  • Do not remove the desiccant bag from the luminaire housing.
  • It is needed to remove residual moisture.

Replacing the LED module

  • The designation of the LED module is noted on a separate label in the luminaire or on the underside of the specific LED module.
  • The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted. The module can be replaced by qualified persons using standard tools.
  • Disconnect the system.

Open the floodlight:

  • Undo the locking pin (hexagon socket head wrench size 2.5 mm) on the back side of the floodlight housing.
  • Remove the trim ring along with the safety glass and reflector by twisting it counterclockwise.
  • Replace the LED module.
  • Please follow the installation instructions for the LED module.
  • Inspect and, if necessary, replace the luminaire gaskets.
  • The defective glass must be replaced.
  • Place the trim ring with glass and reflector on the floodlight housing in such a way that the notches in the trim ring and floodlight housing align on top of each other.
  • Twist on the trim ring clockwise as far as the stop. Tighten the locking pin.

Accessories

  • 71 291 Optical filter flat beam
  • 71333 Shield
  • 71 338 Cylindrical shield

For the accessories, separate instructions for use can be provided upon request.

Spares

  • Trim ring graphite with glass 25 000 281
  • Trim ring silver with glass 25 000 282
  • LED power supply unit DEV-0270/1050i
  • LED module 3000 K LED-0780/930
  • LED module 4000 K LED-0780/940
  • Reflector 75 005 099
  • Gasket housing 83 001 579
  • Gasket mounting box 83 001 839
  • Gasket trim ring 83 002 306