BEGA 85139 Performance Flood Light
Product Information
- Specifications:
- Product Name: Performance Floodlight
- Model Number: 85 139
- Lamp Module Connected Wattage: 36.8 W
- Luminaire Connected Wattage: 40 W
- Colour Temperature: 3000 K or 4000 K
- Colour Rendering Index (CRI): > 90
- Module Luminous Flux: 5145 lm – 5220 lm
- Luminaire Luminous Flux: 3834 lm – 3890 lm
- Luminaire Luminous Efficiency: 95.8 lm/W – 97.2 lm/W
Product Usage Instructions
- Application:
- The Performance Floodlight is suitable for a variety of interior and exterior lighting applications.
- Safety:
- Installation and operation must comply with national safety regulations.
- Only a qualified electrician should perform installation and commissioning to avoid damage due to improper use or installation.
- Any modifications made to the luminaire must be done by a qualified individual.
- Overvoltage Protection:
- The luminaire’s electronic components are protected against overvoltage according to DIN EN 61547.
- Additional protection against transients is recommended through separate overvoltage protection components available on the manufacturer’s website.
- Installation:
- Handle LED components with care during installation to avoid direct contact with the light output opening.
- Place the floodlight unit on the mounting plate as shown in the diagram, align it, and securely fasten it with screws.
- To adjust the beam direction, loosen the joint screw using a 5 mm hexagon socket head wrench, set the desired direction, and then tighten the screw with a torque of 7 Nm.
FAQs
- Q: Can I install the Performance Floodlight myself?
- A: Installation and commissioning should only be carried out by a qualified electrician to ensure safety and proper functionality.
- Q: What should I do if I need to modify the luminaire?
- A: Any modifications to the luminaire should be performed by a qualified individual to avoid voiding the manufacturer’s liability.
Performance Floodlight
Instructions for use
Application
- Performance floodlight with mounting box.
- For a variety of interior and exterior lighting applications.
Product Description
- Luminaire made of aluminium alloy, aluminium and stainless steel
- BEGA Unidure® coating technology
- Colour graphite or silver
- Clear safety glass
- Silicone gasket
- The reflector surface is made of pure aluminium
- BEGA Hybrid Optics®
- The rotation range of floodlight is 350°
- Swivel range -25°/+90°
- Mounting box with 2 fixing holes ø 4.8mm · 67mm spacing 2 cable entries for through-wiring of mains supply cable ø 7-10.5mm, max. 5G1.5@
- Connecting terminal 2.5@ with plug connection
- Earth conductor connection
- BEGA Ultimate Driver®
- Complies with flicker requirements by IEEE 1789,
- DIN IEC/TR 63158, DIN IEC/TR 61547-1
- LED power supply unit 220-240 V x 0/50-60 Hz
- DC 176-264 V
- DALI-controllable
- Number of DALI addresses: 1
- Basic insulation is provided between the mains and control cables
- BEGA Thermal Control®
- Temporary thermal regulation to protect temperature-sensitive components without switching off the luminaire
- Safety class I
- Protection class IP 65
- Dust-tight and protection against water jets
- Impact strength IK06
- Protection against mechanical impacts < 1 joule c – Conformity mark
- Wind catching area: 0.031 m²
- Weight: 2.8 kg
This product contains light sources of energy efficiency class(es) E
Lighting technology
- Symmetrical wide beam light distribution Half beam angle 54°
- For special lighting applications, an optical filter can be used to change the symmetrical light cone into a flat beam light distribution.
Lamp
- Module connected wattage 36.8 W
- Luminaire connected wattage 40 W
- Rated temperature ta=25 °C
- Ambient temperature ta max=40 °C
85 139K3
- Module designation LED-0780/930
- Colour temperature 3000 K
- Colour rendering index CRI >90
- Module luminous flux 5145 lm
- Luminaire luminous flux 3834 lm
- Luminaire luminous efficiency 95,8 lm/W
85 139K4
- Module designation LED-0780/940
- Colour temperature 4000 K
- Colour rendering index CRI >90
- Module luminous flux 5220 lm
- Luminaire luminous flux 3890 lm
- Luminaire luminous efficiency 97,2 lm/W
Safety
- The installation and operation of this luminaire are subject to national safety regulations.
- Installation and commissioning may only be carried out by a qualified electrician.
- The manufacturer accepts no liability for damage caused by improper use or installation.
- If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.
Overvoltage protection
- The electronic components installed in the luminaire are protected against overvoltage per DIN EN 61547.
- To achieve additional protection against e.g. transients, etc. we recommend separate overvoltage protection components.
- You can find them on our website at www.bega.com.
- The ideal protection of all electronic components installed in the luminaires is achieved by using bounce-free switching contacts such as an electronic relay (solid-state relay), e.g. BEGA 71320.
Installation
LEDs are high-quality electronic components!
- Please avoid touching the light output opening of the LED directly during installation or relamping.
- Undo the hexagon socket head screw (wrench size 3mm) up to the stop and disassemble the mounting plate.
- Pass the power connecting cable through the cable entry in the mounting plate.
- Note the position of application of the mounting plate “arrow down”.
- Fix the mounting plate with enclosed or any other suitable fixing material onto the mounting surface.
- Be sure to use the gasket rings supplied.
- Make an earth conductor connection.
- Push silicone sleeves over the lines and make an electrical connection to the terminal (plug connection).
- For digital control please use the 2-pole plug connector DA, DA.
- In case this connector is not used the luminaire will be operated at full light output.
- Push plug into the coupler as far as it will go.
- Connect the floodlight unit’s green and yellow protective earth conductor to the terminal marked 1 in the mounting plate.
- Make sure that the gasket is positioned correctly.
- Place the floodlight unit onto the mounting plate as displayed in the sketch, and align and screw together firmly.
Adjustment of beam direction:
- Undo the joint screw (hexagon socket head wrench size 5 mm) and set the desired beam direction.
- Tighten the joint screw.
- Torque = 7Nm.
Cleaning Maintenance
- Clean the luminaire regularly with solvent-free cleansers from dirt and deposits.
- Do not use high-pressure cleaners.
Maintenance
- The connecting cable between mounting box and the floodlight has to be inspected for obvious damages and has to be replaced by a qualified electrician only.
Please note:
- Do not remove the desiccant bag from the luminaire housing.
- It is needed to remove residual moisture.
Replacing the LED module
- The designation of the LED module is noted on a separate label in the luminaire or on the underside of the specific LED module.
- The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted. The module can be replaced by qualified persons using standard tools.
- Disconnect the system.
Open the floodlight:
- Undo the locking pin (hexagon socket head wrench size 2.5 mm) on the back side of the floodlight housing.
- Remove the trim ring along with the safety glass and reflector by twisting it counterclockwise.
- Replace the LED module.
- Please follow the installation instructions for the LED module.
- Inspect and, if necessary, replace the luminaire gaskets.
- The defective glass must be replaced.
- Place the trim ring with glass and reflector on the floodlight housing in such a way that the notches in the trim ring and floodlight housing align on top of each other.
- Twist on the trim ring clockwise as far as the stop. Tighten the locking pin.
Accessories
- 71 291 Optical filter flat beam
- 71333 Shield
- 71 338 Cylindrical shield
For the accessories, separate instructions for use can be provided upon request.
Spares
- Trim ring graphite with glass 25 000 281
- Trim ring silver with glass 25 000 282
- LED power supply unit DEV-0270/1050i
- LED module 3000 K LED-0780/930
- LED module 4000 K LED-0780/940
- Reflector 75 005 099
- Gasket housing 83 001 579
- Gasket mounting box 83 001 839
- Gasket trim ring 83 002 306
CONTACT
- BEGA Gantenbrink-Leuchten KG
- Postfach 3160
- 58689 Menden
- info@bega.com.
- www.bega.com.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>