Product Information

Specifications

  • Lamp Module connected wattage: 34.7 W
  • Luminaire connected wattage: 38.5 W
  • Rated temperature: 25-55°C
  • Ambient temperature: 25-55°C
  • Colour temperature: 3000 K
  • Colour rendering index (CRI): > 90
  • Module luminous flux: 5400 lm
  • Luminaire luminous flux: 3430 lm
  • Luminaire luminous efficiency: 89.1 lm/W

FAQ

  • Q: Can anyone replace the LED module?
    • A: Only qualified persons should replace the LED module using standard tools following the provided installation instructions.
  • Q: Is overvoltage protection necessary for this luminaire?
    • A: While the luminaire is protected against overvoltage according to standards, additional protection components are recommended for further safety.

Product Overview

Wall luminaire for indoor use

BEGA-51-260-1-Wall-Luminaire-fig-2

Application And Product Description

Application

  • Wall luminaire · indoor luminaire with light emission on one side for the glare free illumination of wall surfaces with the mounting surface being the reflection surface.
  • A luminaire which allows interesting illumination concepts individually or in rows.

Product Description

  • Luminaire housing made of aluminium, finish colour velvet white
  • Silicone light diffuser
  • 3 elongated fixing holes
  • Width 4.5 mm · 895 mm spacing
  • Mounting plate with several openings for cable entry and through-wiring for mains cable
  • Connecting terminals 2.5@
  • Earth conductor connection
  • LED power supply unit: 220-240 V x 0/50-60 Hz
  • DC 176-276 V
  • During DC operation the LED power is reduced to 15 %
  • DALI-controllable
  • Number of DALI addresses: 1
  • Basic insulation is provided between the mains and control cables
  • BEGA Thermal Control®
  • Temporary thermal regulation to protect temperature-sensitive components without switching off the luminaire
  • Safety class I
  • Impact strength IK08
  • Protection against mechanical impacts < 5 joule
  • – Conformity mark
  • Weight: 5.0 kg

This product contains light sources of energy efficiency class(es) D

Safety

  • The installation and operation of this luminaire are subject to national safety regulations.
  • Installation and commissioning may only be carried out by a qualified electrician.
  • The manufacturer accepts no liability for damage caused by improper use or installation.
  • If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Overvoltage protection

  • The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547.
  • To achieve an additional protection against e. g. transients, etc. we recommend separate overvoltage protection components.
  • You can find them on our website at www.bega.com.

Lamp

  • Module connected wattage: 34.7 W
  • Luminaire connected wattage: 38.5 W
  • Rated temperature: ta = 25 °C
  • Ambient temperature: ta max = 55 °C

51 260.1 K3

  • Module designation: LED-1321/930
  • Colour temperature: 3000 K
  • Colour rendering index: CRI > 90
  • Module luminous flux: 5400 lm
  • Luminaire luminous flux: 3430 lm
  • Luminaire luminous efficiency: 89,1 lm / W

Installation

LED are high-quality electronic components!
Please avoid touching the light output opening of the LED directly during installation or relamping.

  • Undo the hexagon socket head screws (wrench size 3 mm) and lift luminaire housing.
  • Loosen earth connection (plug connection) between luminaire housing and mounting plate.
  • Pass the power connecting cable through one of the openings of the mounting plate.
  • Ensure correct directionality towards the area to be illuminated.
  • Fasten the mounting plate with the supplied fastening material or other suitable fastening material to the installation surface.
  • Make the electrical connection to the terminals.
  • Please ensure correct wire assignment for the connecting cable.
  • Connect the earth conductor to the green-yellow wire ( ). Connect the live conductor to the brown wire (L) and the neutral conductor to the blue wire (N).
  • Use the terminals marked DA, DA for digital control.
  • If these terminals are not used, the luminaire will operate at full light output.
  • Make earth connection (plug connection) between luminaire housing and mounting plate again.
  • Hang the luminaire housing in the mounting plate and screw it in place with the hexagon socket head screws.

Maintenance And Replacing The Module

Cleaning · Maintenance

  • Clean luminaire regularly with solvent-free cleansers from dirt.

Replacing the LED module

  • The designation of the LED module is noted on a label in the luminaire.
  • The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted. The module can be replaced by qualified persons using standard tools.
  • Disconnect the system and open the luminaire.
  • Please follow the installation instructions for the LED module.
  • Defective luminaire cover must be replaced.
  • Close the luminaire.

Spares

  • LED power supply unit: DEV-0159/700i
  • LED module 3000 K with diffuser: LED-1321/930