WOODBRIDGE BS5430R Alcove Acrylic Rectangular Whirlpool Heated Jetted Tub User Guide
- June 1, 2024
- WOODBRIDGE
Table of Contents
- WOODBRIDGE BS5430R Alcove Acrylic Rectangular Whirlpool Heated Jetted Tub
- Product Introduction
- Installation Instructions
- INSTRUCTIONS
- TOOLS REQUIRED FOR INSTALLATION
- DIMENSION
- Connect Power Supply
- ELECTRICAL REQUIREMENTS
- INSTALLATION
- IMPORTANT SAFETY RULES
- Care and Cleaning
- Repair and Maintenance
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
WOODBRIDGE BS5430R Alcove Acrylic Rectangular Whirlpool Heated Jetted Tub
Product Introduction
Specifications:
- Model: Woodbridge Modern Alcove Bathtub
- Available Models: BS5430R, BS5430L, BS6030R, BS6030L, BS6032R, BS6032L
- Dimensions:
- BS5430R: 54” x 30” x 21-5/8”
- BS6030R: 60” x 30” x 21-5/8”
- BS6032R: 60” x 32” x 21-5/8”
- BS5430L: 54” x 30” x 21-5/8”
- BS6030L: 60” x 30” x 21-5/8”
- BS6032L: 60” x 32” x 21-5/8”
Installation Instructions
Step 1: Prepare Tools
Before starting the installation, make sure you have the following tools
ready:
- Soft Cloth or Blanket
- Silicone
- Tape Pencil/Marker
- Measure
- Hammer
- Hacksaw Framing Square
- Safety Glass
- Knife
- Level
- Caulk Gun
- Adjustable Wrench
- Channel Lock Pliers
- Drill
Step 2: Check Subfloor and Cut to Accommodate Plumbing
Ensure that the subfloor is level. If needed, level the subfloor with leveling
compound or mortar over the entire area of installation. Cut the subfloor to
accommodate plumbing in compliance with local plumbing and building codes.
Step 3: Position Bathtub
Verify that the draining pipe location matches the actual location of the
bathtub drain. Remove the bathtub and position it correctly according to the
model dimensions provided.
Step 4: Connect Power Supply
Connect the power supply to the control unit. The electrical connections must
comply with local authority regulations and must be done by an authorized
electrician.
Step 5: Fill Bathtub and Test Pump
Fill the bathtub with water to approximately 40 mm above the jets and trial
run the pump for 10-15 minutes. Check all fittings for leaks and test the
control functions. Switch off the spa pump and leave the unit filled with
water (pump is not running) for at least another two minutes. Check the pump
and pipes union connections for leaks and hand tighten union connections if
required.
FAQ:
-
Q: What should I do if I encounter leaks during installation?
A: If you encounter leaks during installation, check the connections and fittings for any loose components. Tighten the connections as needed to stop leaks. -
Q: Can I install the bathtub without professional help?
A: While it’s possible to install the bathtub on your own, it’s recommended to seek professional help, especially for electrical connections, to ensure safety and compliance with regulations.
Certified to the following Codes & Standard:
- UL 1795 Safety Standard for Hydromassage Bathtubs (UL1795)
- ASME A112.19.7 / CSA B45.10) – Hydromassage Bathtub Systems
- CSA B45.5/IAPMO Z124 – Plastic Plumbing Fixtures
- International Plumbing Code® (IPC)
- International Residential Code® (IRC)
- Uniform Plumbing Code® (UPC)
- National Plumbing Code of Canada® (NPC)
INSTRUCTIONS
READ ALL INSTRUCTIONS BEFORE UNPACKING THE PRODUCT
INSTRUCTIONS THAT, IF IGNORED COULD RESULT IN DEATH OR SERIOUS INJURY CAUSED BY INCORRECT HANDLING OR INSTALLATION OF THE PRODUCT. THESE INSTRUCTIONS MUST BE OBSERVED FOR SAFE INSTALLATION.
2 PEOPLE ARE REQUIRED TO LIFT AND DURING ENTIRE INSTALLATION OF THIS PRODUCT.
This products must be installed by a fully insured and licensed plumber only. Installation of any our product by anyone other than fully insured and licensed plumber shall void limited warranty. We recommends that such licensed plumber has experience in the installation of products.
We are not responsible for local code compliance for this product. Building and plumbing codes may vary from state-to-state in accordance to your location. We are not responsible for providing any compliance certifications. Under no circumstances we shall not be liable for any incidental damages sustained in connection with this product Neither manufacture, nor distributor, nor retailer is responsible for water damage or flood caused due to use of this product. Under no circumstances We shall not be liable for any and all fees, cost of installation/reinstallation/removal, subsequent damage or transportation in case of the product defect
TOOLS REQUIRED FOR INSTALLATION
DIMENSION
First ensure that the subfloor is level.
If needed, level subfloor with leveling compound or mortar over the entire
area of installation.
Cut subfloor to accommodate plumbing in compliance with local plumbing and
building code. Verify your bathtub for final dimensions.
Position bathtub.Verify that the draining pipe location matches the actual
location of the bathtub drain. Remove the bathtub.
Connect Power Supply
Connect power supply to control unit. The electrical connections must comply
with local authority regulations and must be done by an authorized
electrician. Fill bathtub with water to approximately 40 mm above the jets and
trial run pump for 10-15 minutes. Check all the fittings for leaks and test the
control functions. Switch off the spa pump and leave the unit filled with water
(pump is not running) for at least another two minutes. Check the pump and
pipes union connections for leaks. Hand tighten union connections if required.
IMPORTANT: Your bathtub has been factory tested and approved. It is the
responsibility of the installer to test run the bathtub, check all the fittings
for leaks and test the control functions. NON OBSERVANCE WILL INVALIDATE
FACTORY WARRANTY.
The unit must be connected only to a supply circuit that is protected by a Ground-Fault Circuit Interrupter (GFCI). Such a GFCI should be provided by the installer and should be tested on a routine basis.
ELECTRICAL REQUIREMENTS
In the example above, there are 2 Dedicated 120V 15AMP GFCI Breakers.
- One (1) Dedicated GFCI Breaker for the Whirlpool Pump
- One (1) Dedicated GFCI Breaker for the Heater
- Heater automatically on when pump starts and will automatically heat up to 100˚F/38˚C
- Heater will stop to heating when water temperature reach 100˚F/38˚C Each application requires a 120V 15AMP Dedicated GFCI Breaker.
INSTALLATION
- The bathtub can be leveled by adjusting the feet. Check your adjustment with a level.
- Lock the adjustment by tighten the hexagon nut.
- The bathtub must be tested before installation is completed. Fill the tub to the overflow and inspect it for leaks. Tighten any loose connections.
- Fasten bathtub to studs framing.
- Apply silicone sealant to seal the joints between the bathtub rim and the finished wall.
- Reference for Correct Tile Flange Installation . Use drawing below as a reference guide for rough-in measurements.
IMPORTANT SAFETY RULES
ATTENTION! ALWAYS FOLLOW THESE PRECAUTIONS WHEN USING A BATHTUB
- Warning The bathtub must be installed and used as described in this manual
- Warning Use caution when entering or exiting the bathtub
- Warning Do not permit children or persons with infirmities to use the bathtub without supervision of an adult
- Warning People using any medications or having adverse medical history must consult a physician prior to use of the bathtub to avoid potential hyperthermia and possible drowning
- Warning Water temperature over 100ºF may cause hyperthermia and/or other health problems. Check water temperature and adjust it for your personal comfort
- Warning Never use bathtub while intoxicated, after taking meals or any alcoholic beverages. Consuming alcoholic beverages before or during bathing will cause drowsiness and may result in hyperthermia, loss of consciousness, or even drowning
- Warning If you are pregnant or you feel that you are may be pregnant, consult your doctor before using the bathtub
- Warning Never use any electrical devices such as hair dryer, lamp, telephone, tv, radio, or others within 5 feet of the bathtub
- Warning Do not overfill the bathtub before enetering. Entering the bathtub when filled will cause overflow and slippery conditions. Use extreme caution when entering and exiting
Care and Cleaning
- Most dirt will wash off with mild soap and warm water.
- For tough spots, use liquid dish washing soap or non-chlorine bleach.
- Do not use abrasive material such steel wool or scouring pads to clean the acrylic surface.
- Always test the cleaning solution on a small area before using it on the entire surface.
- Do not allow cleaning to soak on the acrylic surface.
- Rinse thoroughly with water immediately and wipe dry with soft cloth.
Repair and Maintenance
- Use liquid polish compound such as Gel-Gloss Kitchen and Bath Polish(TM) to keep the original shine of acrylic surface.
- Light scratches can be removed with polishing compound for automobiles.
- For deeper scratches use wet sandpaper (1500 grit or higher). Always add water when sanding and lightly sand the area larger than the scratch in a circular motion to remove the scratches. Repeat until the scratch is removed. Use soft cloth and small amount of polishing compound to restore shine. Repeat as needed until surface shine is restored.
IMPORTANT!
- DO NOT USE: Abrasive cleaners such as: acid, ammonia, bleach, and simmilar solutions. Use of such solutions may cause corrosion, finish peeling, and/or dull the surface.
- DO NOT USE: Abrasive sponges or cloth. Never use steel, wool, or wired brushes that will permanently scratch the surface.
Retain these installation instructions for future reference!
Thank you for using WoodBridge products!
Please don’t hesitate to contact us if you have any questions or concerns.
Customer Service Phone:
562-229-0088. (Monday – Friday 9 AM – 5
PM Pacific Time) Or Email:
help@woodbridgebath.com
Read User Manual Online (PDF format)