BEGA 50337.1 Recessed Ceiling Lights Spots Instruction Manual
- June 1, 2024
- BEGA
Table of Contents
BEGA 50337.1 Recessed Ceiling Lights Spots
Specifications:
- Product: Recessed LED ceiling luminaire
- Power Supply: External LED power supply unit (220-240 V x 0/50-60 Hz)
- Material: Luminaire housing made of cast aluminum
- Finish: White with pure aluminum reflector surface
- Weight: 0.7 kg
- Energy Efficiency : Class D
Product Description
The product is a recessed LED ceiling luminaire with a remote power supply unit. It features a luminaire housing made of cast aluminum with a white finish and a pure aluminum reflector surface. The light-diffusing disc provides uniform light distribution.
Safety Information:
The installation and operation of the luminaire must comply with national safety regulations and should only be carried out by a qualified electrician. Overvoltage protection is built-in, but additional protection components are recommended to guard against transients and other electrical disturbances.
Installation:
- Avoid covering the luminaire housing and external LED power supply unit with heat-insulating materials.
- Avoid direct contact with the LED output opening during installation or relamping.
- Secure the luminaire housing in the recessed opening using the provided springs.
- Clean the luminaire regularly with solvent-free cleansers to prevent dirt buildup.
LED Module Replacement:
To replace the LED module, follow these steps:
- Identify the LED module designation on the label inside the luminaire.
- Disconnect the system and open the luminaire according to the installation instructions.
- Replace the module with a BEGA replacement module that matches the light color and output.
- Close the luminaire securely after replacement.
FAQ
- Q: Can I use heat-insulating materials to cover the luminaire housing?
- A: No, it is advised not to cover the luminaire housing and external LED power supply unit with any heat-insulating materials to prevent overheating.
- Q: How often should I clean the luminaire?
- A : It is recommended to clean the luminaire regularly with solvent-free cleansers to maintain optimal performance and prevent dirt buildup.
Recessed ceiling downlight for indoor use
DIMENSIONS
Instructions for use
Application
Recessed ceiling downlight · Indoor luminaire with symmetrical wide beam light distribution. For installation in suspended ceilings of 5-25mm in interior applications.
Lamp
- Module connected wattage : 17.6 W
- Luminaire connected wattage : 21 W
- Rated temperature: ta=25 °C
- Ambient temperature: ta max=40 °C
50 337.1K3
- Module designation: LED-0838/930
- Color temperature: 3000 K
- Color rendering index : CRI >90
- Module luminous flux : 2670 lm
- Luminaire luminous flux : 1935 lm
- Luminaire luminous efficiency: 92,1 lm/W
50 337.1K4
- Module designation : LED-0838/940
- Color temperature: 4000 K
- Color rendering index : CRI >90
- Module luminous flux : 2715 lm
- Luminaire luminous flux : 1967 lm
- Luminaire luminous efficiency: 93,7 lm/W
Product Description
Recessed LED ceiling luminaire
with a remote power supply unit
Luminaire housing made of cast aluminium
Finish color white
The reflector surface is made of pure aluminum
Light-diffusing disc
Fixing is achieved by using
2 fastening springs
Recessed opening ø 220mm Required installation depth 110mm Connecting cable 2
x 1,0@ External LED power supply unit
220-240 V x 0/50-60 Hz
Safety class II
Safety mark
Conformity mark
Weight: 0.7 kg
This product contains light sources of energy efficiency class(es) D
Light technique
- Symmetrical wide beam light distribution
- Half beam angle 73°
Safety
The installation and operation of this luminaire are subject to national safety regulations. Installation and commissioning may only be carried out by a qualified electrician. The manufacturer accepts no liability for damage caused by improper use or installation. If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.
Overvoltage protection
The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547. To achieve an additional protection against e.g. transients, etc. we recommend separate overvoltage protection components. You can find them on our website at www.bega.com.
Installation
Luminaire housing and external LED power supply units must not be covered by any heat-insulating materials.
LEDs are high-quality electronic components! Please avoid touching the light output opening of the LED directly during installation or relamping. Cover the recessed opening with the stop ring of the luminaire housing. The luminaire housing is then fixed in the recessed opening via two springs.
Installation in suspended ceilings:
A recessed opening of 220 mm with a minimum depth of 110 mm is required. The lateral clearance from the installation housing to parts of the building must be at least 50 mm. The minimal thickness of the ceiling panel must be 5 mm and must not be greater than 25 mm. A ceiling panel with less than 5 mm thickness must be reinforced on the reverse.
The electrical connection must be made on-site in the appropriate safety class on the power supply unit connecting cable. A distribution box must be used. Ensure the correct assignment of theconnecting cable.
Establish the main connection on the brown (L) and blue (N) wires. Guide the LED power supply unit through the opening in the ceiling and position it on the suspended ceiling.
Place the LED unit on top of the luminaire housing over the reflector and lock it in place by turning it to the right.
Compress the fastening springs of the luminaire housing on both sides and slide the luminaire housing into the recessed opening.
The fastening springs lock into place behind the ceiling panel.
Cleaning / Maintenance
Clean the luminaire regularly with solvent-free cleansers from dirt.
Replacing the LED module
The designation of the LED module is noted on a label in the luminaire.
The light color and light output of BEGA replacement modules correspond to
those of the modules originally fitted. The module can be replaced by
qualified persons using standard tools.
Disconnect the system and open the luminaire. Please follow the installation
instructions for the LED module.
Close the luminaire.
Spares
- LED power supply unit : DEV-0310/700
- LED module 3000 K : LED-0838/930
- LED module 4000 K : LED-0838/940
- Reflector: 76 001 622
- BEGA Gantenbrink-Leuchten KG
- Postfach 3160
- 58689 Menden
- info@bega.com