Recessed ceiling downlight for indoor use.
Instructions for use
Application
Ceiling luminaire downlight · Indoor luminaire with symmetrical very wide beam
light distribution. Ready-to-connect set of 3 including external phase-
dimmable LED power supply unit and connection cables between the luminaires.
For installation in suspended ceilings of 3-18 mm in interior applications.
Product description
Set of 3 ready-to-connect recessed ceiling luminaire downlights including external power supply unit. Luminaire housing made of die-cast zinc finish colour velvet white. Reflector surface made of pure aluminium. Fixing is achieved by using 2 fastening springs. Recessed opening ø 68 mm. Required installation depth 48 mm. Connection cable with 2-pole plug connector between luminaires and external LED power supply unit (see sketch). External LED power supply unit 220-240 V y 50-60 Hz. Dimmable via a leading-edge or trailing-edge dimmer. Safety class II 2
- å – Safety mark
- c – Conformity mark
- Weight: 0.6 kg
- This product contains light sources of energy efficiency class(es) E.
Safety
The installation and operation of this luminaire are subject to national
safety regulations. Installation and commissioning may only be carried out by
a qualified electrician. The manufacturer accepts no liability for damage
caused by improper use or installation. If subsequent modifications are made
to the luminaire, the person responsible for these modifications shall be
considered the manufacturer.
Overvoltage protection
The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547. To achieve an additional protection against e. g. transients, etc. we recommend separate overvoltage protection components. You can find them on our website at www.bega.com.
Lamp
- Module connected wattage 4 W
- Luminaire connected wattage 16 W
- Rated temperature ta = 25 °C
- Ambient temperature ta max = 30 °C
51 101.1 K27
- Module designation 3x LED-1208/927
- Colour temperature 2700 K
- Colour rendering index CRI > 90
- Module luminous flux 1620 lm
- Luminaire luminous flux 950 lm
- Luminaire luminous efficiency 59,4 lm / W
51 101.1 K3
- Module designation 3x LED-1208/930
- Colour temperature 3000 K
- Colour rendering index CRI > 90
- Module luminous flux 1740 lm
- Luminaire luminous flux 1020 lm
- Luminaire luminous efficiency 63,8 lm / W
Lighting technology
Symmetrical wide beam light distribution Half beam angle 50°.
Installation
Luminaire housing and external LED power supply unit must not be covered by
any heat insulating materials. LED are high-quality electronic components!
Please avoid touching the light output opening of the LED directly during
installation or relamping.
The ready-to-connect set of recessed ceiling luminaires includes an external phase dimmable LED power supply unit and connection cables with 2-pole plug connector between the luminaires and the LED power supply unit.
Installation in suspended ceilings:
For each luminaire, a recessed opening of 68 mm with a minimum depth of 48 mm
is required. The minimal thickness of the ceiling panel must be 3 mm and must
not be greater than 18 mm. A ceiling panel with less than 3 mm thickness must
be reinforced on the reverse.
The electrical connection must be made on site in the appropriate safety class
on the LED power supply unit connecting cable. A distribution box must be
used. Ensure the correct assignment of the connecting cable. Establish the
mains connection on the brown (L) and blue (N) wires. Guide the LED power
supply unit and connection cable with distribution boxes through the ceiling
opening and deposit them in the suspended ceiling. Make sure that the plug
connectors between connection cables and distribution boxes on the suspended
ceiling are connected correctly before connecting the recessed luminaires. The
luminaires are interlinked in a series connection.
IMPORTANT : Make sure that the series circuit is closed via the plug with
wire jumper in the distribution box of the last luminaire.
Alternatively, plug this plug with wire jumper into the distribution box socket of the last luminaire. Connect the plug of the first recessed luminaire to the integrated socket of the first distribution box until the latch engages. Proceed with additional luminaires in the same way. Cover the recessed opening with the stop ring of the luminaire housing.
The luminaire housing is then fixed in the recessed opening via two springs. Compress the fastening springs of the luminaire housing on both sides and slide the luminaire housing into the recessed opening. The fastening springs lock into place behind the ceiling panel.
Cleaning: Maintenance
Clean luminaire regularly with solvent-free cleansers from dirt.
Replacing the LED module
The designation of the LED module is noted on a label in the luminaire. The
light colour and light output of BEGA replacement modules correspond to those
of the modules originally fitted. The module can be replaced by qualified
persons using standard tools. Disconnect the system and open the luminaire.
Please follow the installation instructions for the LED module. Close the
luminaire.
Spares
- LED power supply unit DEV-0431/700
- Connecting cable 62 001 256
- Connecting cable 62 001 258
- Distributor 64 000 636
- Plug with wire jumper 64 000 637
- LED module 2700 K LED-1208/927
- LED module 3000 K LED-1208/930
- Retaining spring LED component 73 005 597
- LED component 75 004 495 K27
- LED component 75 004 495 K3
- Reflector 76 002 020
BEGA Gantenbrink-Leuchten KG
Postfach 31 60
58689 Menden
info@bega.com
www.bega.com
Documents / Resources
| BEGA
51101.1K27 Recessed ceiling lights-
spots
[pdf] Instruction Manual
51101.1K27 Recessed ceiling lights-spots, 51101.1K27, Recessed ceiling lights-
spots, ceiling lights-spots, lights-spots, spots
---|---
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>