BEGA 34560 Recessed Ceiling Light Instruction Manual

June 1, 2024
BEGA

BEGA 34560 Recessed Ceiling Light

BEGA-34560-Recessed-Ceiling-Light-PRODUCT

Product Information

Specifications:

  • Module connected wattage: 5.6 W
  • Luminaire connected wattage: 7.2 W
  • Rated temperature: 25°C
  • Ambient temperature: 50°C

Product Usage Instructions

Safety Instructions:

The installation and operation of this luminaire must comply with national safety regulations. Only a qualified electrician should carry out the installation and commissioning. The manufacturer is not liable for damages due to improper use or installation.

Overvoltage Protection:

The electronic components in the luminaire are protected against overvoltage as per DIN EN 61547. For additional protection against transients, it is recommended to use separate overvoltage protection components available on the manufacturer’s website.

Replacing the LED Module:

To replace the LED module, follow these steps:

  1. Disconnect the system and open the luminaire.
  2. Follow the installation instructions for the LED module.
  3. Inspect and replace the luminaire gaskets if necessary.
  4. Replace any defective glass.
  5. Close the luminaire after replacing the module.

Power Supply Units:

The power supply units provided are suitable for operating one LED luminaire only.

FAQ

  • Q: Can I use the power supply units for multiple LED luminaires?
    A: No, the power supply units are only suitable for operating one LED luminaire each.

  • Q: How can I replace the LED module?
    A: To replace the LED module, disconnect the system, open the luminaire, follow the installation instructions for the LED module, inspect and replace gaskets if needed, replace any defective glass, and then close the luminaire.

DIMENSION

BEGA-34560-Recessed-Ceiling-Light-FIG- \(1\)

Recessed ceiling luminaire for indoor use

Instructions for use

Application

  • Recessed ceiling luminaire · indoor luminaire with hand-blown opal glass, satin matt and metal housing for connection to external LED power supply unit.
  • They are ideal for places where a soft and uniform lighting distribution is required.
  • For installation into ceilings with a shallow depth in interior areas.

Product description

  • Luminaire housing made of metal
  • Opal glass, satin matt, with screw neck
  • Silicone gasket
  • Fixing is achieved by using two adjustable wedge-shaped claws
  • Connecting cable with strain relief and plug connector system for BEGA power supply unit, on/off or DALI.
  • Safety class III 3
  • – Safety mark
  • – Conformity mark
  • Weight: 0.6 kg
  • This product contains light sources of energy efficiency class(es) D

Safety

  • The installation and operation of this luminaire are subject to national safety regulations.
  • Installation and commissioning may only be carried out by a qualified electrician.
  • The manufacturer accepts no liability for damage caused by improper use or installation.
  • If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer

Overvoltage protection

  • The electronic components installed in the luminaire are protected against overvoltage by DIN EN 61547.
  • To achieve additional protection against e. g. transients, etc. we recommend separate overvoltage protection components.
  • You can find them on our website at www.bega.com

SPECIFICATION

Lamp

  • Module connected wattage 5.6 W
  • Luminaire connected wattage 7.2 W
  • Rated temperature ta = 25 °C
  • Ambient temperature ta max = 50 °C
  • When installed in heat-insulating
  • material ta max = 25 °C

34 560 K3

  • Module designation LED-0329/930
  • Colour temperature 3000 K
  • Colour rendering index CRI > 90
  • Module luminous flux 895 lm
  • Luminaire luminous flux 709 lm
  • Luminaire luminous efficiency 98,5 lm / W

34 560 K4

  • Module designation LED-0329/940
  • Colour temperature 4000 K
  • Colour rendering index CRI > 90
  • Module luminous flux 930 lm
  • Luminaire luminous flux 736 lm
  • Luminaire luminous efficiency 102,2 lm / W

Installation

  • LEDs are high-quality electronic components! Please avoid touching the light output opening of the LED directly during installation or relamping.
  • A separate power supply unit is required to operate the luminaire.
  • For connection to the external LED power supply unit – accessory 13 176 or 13 172 – the
  • luminaire is equipped with a 2-pin connector.
  • Note the operating instructions of the LED-power supply units.
  • The recessed opening is covered by the frame of the luminaire housing.
  • Fixing of the luminaire in the structure is achieved by using two adjustable wedge-shaped claws.

Installation into concrete ceilings:
For this purpose installation housing 13 024 is available.

Installation into inserted ceilings:

  • A recessed opening of ø 118 mm is necessary to accept the luminaire housing.
  • Recessed depth min. 45 mm.
  • The lateral distance between the recessed luminaire and other building parts must be at least 50 mm.
  • The claws catch the ceiling facing from the back side. The minimum thickness of the ceiling facing is 3 mm. If the ceiling facing has a thickness of less than 10 mm or in case of an installation into plasterboard ceilings, the facing thickness in the region of the claws must be increased from the back side.

Open luminaire:

  • Remove glass from luminaire housing by turning it counterclockwise.
  • Connect the plug part of the luminaire with the power supply unit.
  • Push the external LED power supply unit and luminaire housing into the ceiling cut-out.
  • Hand-tighten the screws of the claw fastener evenly. Do not use an electric screwdriver!
  • Screw glass with gasket into luminaire housing.
  • Make sure that the gasket is positioned correctly.

Cleaning Maintenance

Clean the luminaire regularly with solvent-free cleansers from dirt

Replacing the LED module

  • The designation of the LED module is noted on a label in the luminaire.
  • The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted.
  • The module can be replaced by qualified persons using standard tools.
  • Disconnect the system and open the luminaire.
  • Please follow the installation instructions for the LED module.
  • Inspect and, if necessary, replace the luminaire gaskets.
  • The defective glass must be replaced.
  • Close the luminaire.

Accessories

  • Power supply units for LED luminaires 220-240 V · 0/50-60 Hz with strain relief and plug connector system.
    • 13 176 Power supply unit on/off
    • 13 172 Power supply unit DALI
  • The power supply units are only suitable for the operation of one LED luminaire.
  • 13 024 Installation housing

For the accessories, separate instructions for use can be provided upon request.

Spares

  • Spare glass 11 003 085 40R G
  • LED module 3000 K LED-0329/930
  • LED module 4000 K LED-0329/940
  • Gasket glass 83 001 444

BEGA Gantenbrink-Leuchten KG · Postfach 31 60 · 58689 Menden