BEGA 85019K3 Compact Projector Instruction Manual

June 1, 2024
BEGA

BEGA 85019K3 Compact Projector

BEGA 85019K3 Compact Projector

Dimensions

Dimensions
Dimensions

Instructions For Use

Application

Compact floodlight BEGA Uni Link® with connection adapter for use in combination with various accessories, e.g. for mounting on trees, pipes or wooden structures.
A separate mains plug must be ordered in order to connect the floodlight to the mains. The various country-specific mains plugs with 0.5m connecting cable, as well as extension cables and five-way distribution boxes are available as accessories.

Product description

Floodlight made of aluminium alloy, aluminium and stainless steel BEGA Uni dure® coating technology Colour graphite or silver Clear safety glass Reflector surface made of pure aluminium Rotation range of floodlight 360° Swivel range -25°/+45° 5m mains supply cable X05RN-F FEP 2×1@ + 1G2,5@ with BEGA Uni Link® plug-in connector BEGA Ultimate Driver® Complies with flicker requirements in accordance with IEEE 1789, DIN IEC/TR 63158, DIN IEC/TR 61547-1 LED power supply unit 220-240 V y 50/60 Hz BEGA Thermal Control® Temporary thermal regulation to protect temperature-sensitive components without switching off the luminaire Safety class I Protection class IP 65 Dust-tight and protection against water jets Impact strength IK06 Protection against mechanical impacts < 1 joule.
– Conformity mark
Weight: 1.4 kg
This product contains light sources of energy efficiency class(es) D.

Safety

The installation and operation of this luminaire are subject to national safety regulations. The manufacturer accepts no liability for damage caused by improper use or installation. If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Total load

When configuring your lighting system, please ensure that the maximum power consumption of 6A is not exceeded. Information on power consumption can be found in the instructions for use and data sheets for all BEGA Uni Link® luminaires.
Power consumption of 85 019: 0,06 A

Lamp

Module connected wattage 8.4 W
Luminaire connected wattage 9.6 W
Rated temperature ta=25 °C
Ambient temperature ta max=50 °C

85 019K3

Module designation| LED-1269/930
color temperature| 3000 K
color rendering index| CRI >90
Module luminous flux| 1265 lm
Luminaire luminous flux| 918 lm
Luminaire luminous efficiency| 95,6 lm/W
85 019K4

Module designation| LED-1269/940
Color temperature| 4000 K
color rendering index| CRI >90
Module luminous flux| 1330 lm
Luminaire luminous flux| 965 lm
Luminaire luminous efficiency| 100,5 lm/W

Light technique

Symmetrical wide beam light distribution Half beam angle 48°.
The symmetrical light cone can be modified to resemble flat beam light distribution for special lighting applications by replacing the cover glass.

Overvoltage protection

The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e.g. transients, etc. we recommend separate overvoltage protection components.
You can find them on our website at www.bega.com.

Caution:
The BEGA Uni Link® plug connectors may only be connected and disconnected in a voltage free state.

Installation

Unscrew the hexagon socket screws (wrench size 3 mm) on the sides of the connection adapter and screw the corresponding accessory to the floodlight.
Torque = 5Nm.

Plug the floodlight’s connecting cable into the plug contact of the connecting cable with the country-specific mains plug, or into the distribution box or extension cable.
To ensure a sufficiently low protective conductor resistance (loop resistance), the connecting cable of each luminaire in the system must not exceed a length of 50m from the entry point.

Adjustment of beam direction:
Undo joint screw (hexagon socket head wrench size 3 mm) and set the desired beam direction.
Tighten the joint screw.
Torque = 2.5Nm.

Please note:
Do not remove the desiccant bag from the luminaire housing.
It is needed to remove residual moisture.

Maintenance

The connecting cable must be checked for external damage and may only be replaced by a qualified electrician.

Replacing the LED module

The designation of the LED module is noted on a label in the luminaire.
The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted. The replacement can be carried out by a qualified person using standard tools.
Disconnect the system from the power supply.
Open the floodlight:
Remove the trim ring along with the safety glass and reflector by twisting it anti-clockwise.
Replace LED module.
Please follow the installation instructions for the LED module.
Inspect and, if necessary, replace the luminaire gaskets.
Defective glass must be replaced.
Place the trim ring with glass and reflector on the floodlight housing so that the notches in the trim ring and luminaire housing sit on top of each other.
Twist on the trim ring clockwise as far as the stop.

Accessories

The following combination options are available for fitting to floodlights with connection adapter:

71 223 Screw clamp with connection adapter
71 224 Tube clamp with connection adapter
71 225 Lashing strap with connection adapter
71 226 General fastener with connection adapter
71 227 G½ mount with connection adapter
71278 Shield
71 283 Cylindrical shield
71 288 Exchangeable lens flat beam

Country-specific mains plugs with 0.5 m connecting cable
71180| Plug type F / E: system common in Germany and Europe
71181| Plug type G: system used in Great Britain (“Commonwealth plug”)
71182| Plug type J: system common in Switzerland and Liechtenstein
71183| Plug type L: system common in Italy and Greece
71184| Plug type K: system common in Denmark and Greenland
71 186| BEGA Uni Link® Extension cable 5m
71 187| BEGA Uni Link® Extension cable 10m
71 188| BEGA Uni Link® Extension cable 20m
71 247| Connecting cable 5m with free line ends
71 256| Connecting cable 0.5m with free line ends
71 189| BEGA Uni Link® Five-way distribution box

For the accessories a separate instructions for use can be provided upon request.

Spares

Trim ring graphite with glass 25 000 174
Trim ring silver with glass 25 000 175
LED power supply unit DEV-0447/250
LED module 3000 K LED-1269/930
LED module 4000 K LED-1269/940
Reflector 75 005 133
Gasket glass 83 002 045
Gasket housing 83 002 180

CUSTOMER SUPPORT

BEGA Gantenbrink-Leuchten KG · Postfach 3160 · 58689 Menden ·
info@bega.com
www.bega.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals