Dimensions
Instructions For Use
Application
Compact floodlight BEGA Uni Link® with connection adapter for use in
combination with various accessories, e.g. for mounting on trees, pipes or
wooden structures.
A separate mains plug must be ordered in order to connect the floodlight to
the mains. The various country-specific mains plugs with 0.5m connecting
cable, as well as extension cables and five-way distribution boxes are
available as accessories.
Product description
Floodlight made of aluminium alloy, aluminium and stainless steel BEGA Uni
dure® coating technology Colour graphite or silver Clear safety glass
Reflector surface made of pure aluminium Rotation range of floodlight 360°
Swivel range -25°/+45° 5m mains supply cable X05RN-F FEP 2×1@ + 1G2,5@ with
BEGA Uni Link® plug-in connector BEGA Ultimate Driver® Complies with flicker
requirements in accordance with IEEE 1789, DIN IEC/TR 63158, DIN IEC/TR
61547-1 LED power supply unit 220-240 V y 50/60 Hz BEGA Thermal Control®
Temporary thermal regulation to protect temperature-sensitive components
without switching off the luminaire Safety class I Protection class IP 65
Dust-tight and protection against water jets Impact strength IK06 Protection
against mechanical impacts < 1 joule.
– Conformity mark
Weight: 1.4 kg
This product contains light sources of energy efficiency class(es) D.
Safety
The installation and operation of this luminaire are subject to national safety regulations. The manufacturer accepts no liability for damage caused by improper use or installation. If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.
Total load
When configuring your lighting system, please ensure that the maximum power
consumption of 6A is not exceeded. Information on power consumption can be
found in the instructions for use and data sheets for all BEGA Uni Link®
luminaires.
Power consumption of 85 019: 0,06 A
Lamp
Module connected wattage | 8.4 W |
---|---|
Luminaire connected wattage | 9.6 W |
Rated temperature | ta=25 °C |
Ambient temperature | ta max=50 °C |
85 019K3
Module designation| LED-1269/930
color temperature| 3000 K
color rendering index| CRI >90
Module luminous flux| 1265 lm
Luminaire luminous flux| 918 lm
Luminaire luminous efficiency| 95,6 lm/W
85 019K4
Module designation| LED-1269/940
Color temperature| 4000 K
color rendering index| CRI >90
Module luminous flux| 1330 lm
Luminaire luminous flux| 965 lm
Luminaire luminous efficiency| 100,5 lm/W
Light technique
Symmetrical wide beam light distribution Half beam angle 48°.
The symmetrical light cone can be modified to resemble flat beam light
distribution for special lighting applications by replacing the cover glass.
Overvoltage protection
The electronic components installed in the luminaire are protected against
overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e.g. transients, etc. we recommend
separate overvoltage protection components.
You can find them on our website at www.bega.com.
Caution:
The BEGA Uni Link® plug connectors may only be connected and disconnected in a
voltage free state.
Installation
Unscrew the hexagon socket screws (wrench size 3 mm) on the sides of the
connection adapter and screw the corresponding accessory to the floodlight.
Torque = 5Nm.
Plug the floodlight’s connecting cable into the plug contact of the connecting
cable with the country-specific mains plug, or into the distribution box or
extension cable.
To ensure a sufficiently low protective conductor resistance (loop
resistance), the connecting cable of each luminaire in the system must
not exceed a length of 50m from the entry point.
Adjustment of beam direction:
Undo joint screw (hexagon socket head wrench size 3 mm) and set the desired
beam direction.
Tighten the joint screw.
Torque = 2.5Nm.
Please note:
Do not remove the desiccant bag from the luminaire housing.
It is needed to remove residual moisture.
Maintenance
The connecting cable must be checked for external damage and may only be replaced by a qualified electrician.
Replacing the LED module
The designation of the LED module is noted on a label in the luminaire.
The light colour and light output of BEGA replacement modules correspond to
those of the modules originally fitted. The replacement can be carried out by
a qualified person using standard tools.
Disconnect the system from the power supply.
Open the floodlight:
Remove the trim ring along with the safety glass and reflector by twisting it
anti-clockwise.
Replace LED module.
Please follow the installation instructions for the LED module.
Inspect and, if necessary, replace the luminaire gaskets.
Defective glass must be replaced.
Place the trim ring with glass and reflector on the floodlight housing so that
the notches in the trim ring and luminaire housing sit on top of each other.
Twist on the trim ring clockwise as far as the stop.
Accessories
The following combination options are available for fitting to floodlights with connection adapter:
71 223 | Screw clamp with connection adapter |
---|---|
71 224 | Tube clamp with connection adapter |
71 225 | Lashing strap with connection adapter |
71 226 | General fastener with connection adapter |
71 227 | G½ mount with connection adapter |
71278 | Shield |
71 283 | Cylindrical shield |
71 288 | Exchangeable lens flat beam |
Country-specific mains plugs with 0.5 m connecting cable
71180| Plug type F / E: system common in Germany and Europe
71181| Plug type G: system used in Great Britain (“Commonwealth plug”)
71182| Plug type J: system common in Switzerland and Liechtenstein
71183| Plug type L: system common in Italy and Greece
71184| Plug type K: system common in Denmark and Greenland
71 186| BEGA Uni Link® Extension cable 5m
71 187| BEGA Uni Link® Extension cable 10m
71 188| BEGA Uni Link® Extension cable 20m
71 247| Connecting cable 5m with free line ends
71 256| Connecting cable 0.5m with free line ends
71 189| BEGA Uni Link® Five-way distribution box
For the accessories a separate instructions for use can be provided upon request.
Spares
Trim ring graphite with glass | 25 000 174 |
---|---|
Trim ring silver with glass | 25 000 175 |
LED power supply unit | DEV-0447/250 |
LED module 3000 K | LED-1269/930 |
LED module 4000 K | LED-1269/940 |
Reflector | 75 005 133 |
Gasket glass | 83 002 045 |
Gasket housing | 83 002 180 |