BEGA 24 213 Wall Luminaire
DIMENSION
Recessed wall luminaire
Instructions for use
Application
Wall luminaire with unshielded light for flush or surface-mounted
installation. Luminaire for the illumination of corridors, paths and
staircases.
Product Description
- LED recessed luminaire without power supply unit
- Luminaire made of cast aluminium, aluminium and stainless steel
- BEGA Unidure® coating technology
- Colour graphite or silver
- Safety glass, white
- Silicone gasket
- Required recessed opening 70 x 70 mm Recessed depth 80 mm
- Fixing is achieved by using two adjustable wedge-shaped claws 1 cable entry for connecting cable max. ø 10,5 mm Connecting terminals 2.5@
- Safety class III
- Protection class IP 65
- Dust-tight and protection against water jets
- – Safety mark
- Impact strength IK05
- Protection against mechanical impacts < 0.7 joule
- – Conformity mark
- Weight: 0.25 kg
- This product contains light sources of energy efficiency class(es) E
Please note: The luminaire can only be operated with an operating device that fulfils the requirements according to EN 61347-2-13. The maximum idle voltage of 60 V DC must conform to SELV or SELV equivalent.
Safety
The installation and operation of this luminaire are subject to national safety regulations. Installation and commissioning may only be carried out by a qualified electrician. The manufacturer accepts no liability for damage caused by improper use or installation. If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.
Please note:
The luminaire must not have permanent contact with aggressive media.
Aggressive media can be washed out of building materials and destroy the
housing of the luminaire. In case of an unknown composition of the building
materials a material analysis is to be carried out before installation of the
luminaire. Aggressive media that is outgoing from the surface might also
affect the luminaire. Thus an overuse of cleaning agents in the surroundings
of the luminaire must be avoided.
Installation
The electrical connection must only be made to safety transformers according to EN 61558 – see accessories. The recessed opening will be covered by the frame of the luminaire housing. Fixing of the luminaire is achieved by using two adjustable wedge-shaped claws.
Installation in solid, plastered walls:
The installation housing 10 406 is available for this purpose. If this is not
used, an exact recessed opening of 70 x 70 mm with a minimum depth of 80 mm is
required.
Installation in exposed brickwork:
The construction of an on-site recessed opening with the exact installation
dimensions of 70 x 70 mm with a minimum depth of 80 mm is required. An
installation housing cannot be used.
Installation in drywalling
A recessed opening of 70 x 70 mm with a minimum depth of 80 mm is required.
The claws grip behind drywall.
Open luminaire:
Undo hexagon socket screws (SW 3) and remove the housing cover. Do not remove
the desiccant pouch from the luminaire housing. It is needed to remove
residual moisture. Lead the secondary connecting cable supplied by others from
the power supply unit through the cable entry into the luminaire housing. Make
the electrical connection: Connect the black conductor with the negative pole
and the red conductor with the positive pole of the power supply unit. A 24 V
safety direct voltage source with a smoothed residual ripple of max. 10 % is
required for the electrical connection of the luminaire – see accessories. If
other safety direct voltage sources are used, an upstream fuse (max. 6 A) must
be provided by the customer. Assemble the housing cover. Make sure that the
gasket is positioned correctly. Tighten the screws evenly. Insert luminaire
housing into the recessed opening. Tighten the screws of the claw fastener
(torx drive T10) evenly.
Lamp
- Module connected wattage 3.6 W
- Luminaire connected wattage 4 W
- Rated temperature ta = 25 °C
- Ambient temperature ta max = 50 °C
- When installed in heat-insulating
- material ta max = 40 °C
- Voltage 24 V = DC
24 213 K3
- Module designation LED-0797/930
- Colour temperature 3000 K
- Colour rendering index CRI > 90
- Module luminous flux 510 lm
- Luminaire luminous flux 109 lm
- Luminaire luminous efficiency 27,2 lm / W
24 21 3 K4
- Module designation LED-0797/940
- Colour temperature 4000 K
- Colour rendering index CRI > 90
- Module luminous flux 530 lm
- Luminaire luminous flux 113 lm
- Luminaire luminous efficiency 28,2 lm / W
Cleaning · Maintenance
Clean the luminaire regularly with solvent-free cleansers from dirt and deposits. Do not use high-pressure cleaners.
Replacing the LED module
The designation of the LED module is noted on a label in the luminaire. The
light colour and light output of BEGA replacement modules correspond to those
of the modules originally fitted. The module can be replaced by qualified
persons using standard tools. Disconnect the system and open the luminaire.
Please follow the installation instructions for the LED module. Inspect and,
if necessary, replace the luminaire gaskets. The defective glass must be
replaced. Close the luminaire.
Accessories
Power supply unit for LED luminaires 24 V DC Safety transformer according to
- EN 61558/VDE 0570 part 2-6
- 70 564 Power supply unit for 5-15 W
- 70 465 Power supply unit for 10-25 W
- 70 565 Power supply unit for 20-35 W
- 70 566 Power supply unit for 30-50 W
- 70 567 Power supply unit for 40-75 W
- 70 169 Power supply unit for 70-150 W 230 V 50-60 Hz
- 71 134 Power supply unit for 0-70 W
- AC range : AC: 198-264 V 50-60 Hz
- DC range: DC: 176-275 V
The power supply units are also suitable for the operation of several LED luminaires. In this case, the maximum wattage of the power supply unit must not be exceeded.
- 10 406 Installation housing
- 10 006 Plaster frame
- 10 070 Plaster frame flush
For the accessories, separate instructions for use can be provided upon request.
Spares
- LED module 3000 K LED-0797/930
- LED module 4000 K LED-0797/940
- Gasket 83 002 226