BEGA 23 253.6 Wall Luminaire Instruction Manual

June 1, 2024
BEGA

BEGA 23 253.6 Wall Luminaire

Specifications:

  • Lamp Module connected wattage: 10.5 W – 12.8 W
  • Luminaire connected wattage: 10.5 W – 12.8 W
  • Colour temperature: 3000 K – 4000 K
  • Colour rendering index (CRI): > 90
  • Module luminous flux: 1735 lm – 1830 lm
  • Luminaire luminous flux: 1318 lm – 1390 lm
  • Luminaire luminous efficiency: 103 lm/W – 108.6 lm/W

Product Usage Instructions

  • Safety:
    The installation and operation of this luminaire must comply with national safety regulations. Only a qualified electrician should carry out the installation and commissioning. The manufacturer is not liable for damage due to improper use or installation. Any modifications should be performed by authorized personnel.

  • Overvoltage Protection:
    The luminaire’s electronic components are protected against overvoltage according to DIN EN 61547. For additional protection against transients, it is recommended to use separate overvoltage protection components available on the manufacturer’s website.

  • Installation:
    When mounting or disassembling, maintain a minimum distance of 300 mm between the removable cap and the wall. Avoid direct contact with the LED light output opening during installation or relamping as LEDs are high-quality electronic components.

  • Replacement Parts:
    For spare parts such as spare glass, LED power supply unit, LED modules (3000 K and 4000 K), and gasket, use the specified part numbers for ordering.

FAQ:

  • Q: Can I install the luminaire myself?
    A: No, installation and commissioning should only be done by a qualified electrician to ensure safety and proper functioning.

  • Q: What should I do if I need to replace a part?
    A: Use the specified part numbers provided in the manual to order the correct replacement parts.

Technical amendments reserved

Wall luminaire for indoor use

BEGA-23-253-6-Wall-Luminaire-fig- \(2\)

Instructions for use

Application

  • Wall luminaire · indoor luminaire made of handblown opal glass and metal housing, for all lighting tasks in interior applications.
  • They are ideal for places where a soft and uniform lighting distribution is required.
  • Luminaire with a high protection class.

Product description

  • Luminaire made of Aluminium, finish Colour velvet copper
  • Hand-blown opal glass
  • Two elongated mounting holes
  • Width 6 mm · 365 mm spacing
  • Insulating housing with cable entry for mains supply cable up to ø 10,5 mm, max. 3 x 1,5
  • Connection terminal 2.5
  • Earth conductor connection
  • Complies with flicker requirements in accordance with IEEE 1789,
  • DIN IEC/TR 63158, DIN IEC/TR 61547-1
  • LED power supply unit 220-240 V x 0/50-60 Hz
  • DC 170-276 V
  • BEGA Thermal Switch®
  • Temporary thermal shutdown to protect temperature-sensitive components
  • Safety class I
  • Protection class IP 44
  • Protected against granular foreign bodies
  • ≥ 1 mm and splash water
  • Impact strength IK02
  • Protection against mechanical impacts < 0.2 joule
  • – Safety mark
  • – Conformity mark
  • Weight: 1.8 kg
  • This product contains light sources of energy efficiency class(es) D

Safety

  • The installation and operation of this luminaire are subject to national safety regulations. Installation and commissioning may only be carried out by a qualified electrician.
  • The manufacturer accepts no liability for damage caused by improper use or installation. If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Overvoltage protection

  • The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547.
  • To achieve an additional protection against e. g. transients, etc. we recommend separate overvoltage protection components.
  • You can find them on our website at www.bega.com.

Lamp

  • Module connected wattage 10.5 W
  • Luminaire connected wattage 12.8 W
  • Rated temperature ta = 25 °C
  • Ambient temperature ta max = 45 °C

23 253.6 K3
Module designation

  • LED-0424/930 LED-0425/930
  • Colour temperature 3000 K
  • Colour rendering index CRI > 90
  • Module luminous flux 1735 lm
  • Luminaire luminous flux 1318 lm
  • Luminaire luminous efficiency 103 lm / W

23 253.6 K4
Module designation

  • LED-0424/940 LED-0425/940
  • Colour temperature 4000 K
  • Colour rendering index CRI > 90
  • Module luminous flux 1830 lm
  • Luminaire luminous flux 1390 lm
  • Luminaire luminous efficiency 108,6 lm / W

Insulation housing

Installation

  • For mounting and dismantling please keep a minimum distance of 300 mm between the removable cap and the wall.
  • LEDs are high-quality electronic components! Please avoid touching the light output opening of the LED directly during installation or relamping.
  • Open luminaire:
    • Loosen knob, remove cap and glass.
    • Drill mounting holes into the mounting surface – spacing 365 mm.
  • For the mains supply connecting open the insulation housing – pull open – strip mains supply cable max. 15 mm and lead it into the insulation housing – see sketch.
  • Make earth conductor connection and electrical connection.
  • Connect both parts of the insulation housing until they audibly engage.
  • The outer coating of the cable has to be fully enclosed by the compression nipple.
  • Fix luminaire with enclosed or any other suitable fixing material onto the mounting surface. Place glass into luminaire housing, close luminaire with the cap and screw in knob into the cap.

Cleaning · Maintenance

Clean luminaire regularly with solvent-free cleansers from dirt.

Replacement of the LED module

  • The designation of the LED module is noted on a separate label in the luminaire or on the underside of the specific LED module.
  • The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted. The module can be replaced by qualified persons using standard tools.
  • Disconnect the system.
  • Loosen lateral knob, remove cap and take out glass.
  • Please follow the installation instructions for the LED module.
  • Defective glass must be replaced.
  • Insert glass into luminaire housing, close luminaire with the cap and screw in knob into the cap.

Spares

  • Spare glass 11 002 947 .1R G
  • LED power supply unit DEV-0341/350
  • LED module 3000 K LED-0425/930
  • LED module 4000 K LED-0425/940
  • LED module 3000 K LED-0424/930
  • LED module 4000 K LED-0424/940
  • Gasket 83 001 179

BEGA Gantenbrink-Leuchten KG · Postfach 31 60 · 58689 Menden · info@bega.com · www.bega.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals