BEGA 50 652 Ceiling and Wall Luminaire For Indoor Use Instruction Manual
- June 1, 2024
- BEGA
Table of Contents
- BEGA 50 652 Ceiling and Wall Luminaire For Indoor Use
- Product Usage Instructions
- DIMENSION
- Instructions for use
- Product Description
- Safety
- Overvoltage protection
- Lamp
- Installation
- Replacement of the LED module Maintenance
- Spares
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
BEGA 50 652 Ceiling and Wall Luminaire For Indoor Use
Specifications:
- Lamp Module connected wattage: 25.3 W
- Luminaire connected wattage: 29 W
- Colour temperature: 3000 K (LED-0570/930) or 4000 K (LED-0570/940)
- Colour rendering index (CRI): > 90
- Module luminous flux: 3615 lm (3000 K) or 3760 lm (4000 K)
- Luminaire luminous flux: 2465 lm (3000 K) or 2564 lm (4000 K)
- Luminaire luminous efficiency: 85 lm/W (3000 K) or 88.4 lm/W (4000 K)
Product Usage Instructions
Safety Precautions:
The installation and operation of this luminaire must adhere to national safety regulations. Only a qualified electrician should perform the installation and commissioning. The manufacturer does not accept liability for damages resulting from improper use or installation. Any modifications should be conducted by a qualified person.
Overvoltage Protection:
The electronic components in the luminaire are protected against
overvoltage according to DIN EN 61547. For additional protection against
transients, separate overvoltage protection components are recommended and can
be found on the manufacturer’s website at www.bega.com.
Replacement Parts:
If replacement parts are needed, the following spare parts are available:
- Spare glass: 11 002 771 .0R G
- LED power supply unit: DEV-0291/850
- LED module 3000 K: LED-0570/930
- LED module 4000 K: LED-0570/940
FAQ:
-
Q: Can I install the luminaire myself?
A: No, only a qualified electrician should carry out the installation and commissioning to ensure safety and proper functioning of the luminaire. -
Q: Where can I find overvoltage protection components?
A: Additional overvoltage protection components can be found on the manufacturer’s website at www.bega.com.
DIMENSION
Instructions for use
Application
- Ceiling and wall luminaire · indoor luminaire made of hand-blown opal glass, satin matt and metal housing, for all lighting tasks.
- They are ideal for places where a soft and uniform lighting distribution is required.
Product Description
- Metal housing, finish colour white
- Hand-blown opal glass, satin matt,
- with sliding-bolt closure
- 2 mounting holes ø 5.5 mm
- Distance apart 240 mm
- 2 cable entries for through-wiring for mains
- cable up to ø 10.5 mm max. 3 × 1.5@
- Connecting terminal 2.5@
- with plug connection
- Earth conductor connection
- Complies with flicker requirements in
- accordance with IEEE 1789,
- DIN IEC/TR 63158, DIN IEC/TR 61547-1
- LED power supply unit
- 220-240 V x 0/50-60 Hz
- DC 170-280 V
- BEGA Thermal Switch®
- Temporary thermal shutdown to protect
- temperature-sensitive components
- Safety class I
- Protection class IP 44
- Protected against granular foreign bodies
- ≥ 1 mm and splash water
- Impact strength IK06
- Protection against mechanical
- impacts < 1 joule
- – Safety mark
- – Conformity mark
- Weight: 3.8 kg
This product contains light sources of energy efficiency class(es) D, E
Safety
- The installation and operation of this luminaire are subject to national safety regulations.
- Installation and commissioning may only be carried out by a qualified electrician.
- The manufacturer accepts no liability for damage caused by improper use or installation.
- If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer
Overvoltage protection
- The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547.
- To achieve an additional protection against e. g. transients, etc. we recommend separate overvoltage protection components.
- You can find them on our website at www.bega.com.
Lamp
- Module connected wattage 25.3 W
- Luminaire connected wattage 29 W
- Rated temperature ta = 25 °C
- Ambient temperature ta max = 40 °C
50 652 K3
- Module designation LED-0570/930
- Colour temperature 3000 K
- Colour rendering index CRI > 90
- Module luminous flux 3615 lm
- Luminaire luminous flux 2465 lm
- Luminaire luminous efficiency 85 lm / W
50 652 K4
- Module designation LED-0570/940
- Colour temperature 4000 K
- Colour rendering index CRI > 90
- Module luminous flux 3760 lm
- Luminaire luminous flux 2564 lm
- Luminaire luminous efficiency 88,4 lm / W
Installation
- LEDs are high-quality electronic components!
- Please avoid touching the light output opening of the LED directly during installation or relamping.
- Disassemble the LED module.
- Loosen LED connection and earth connection (plug connection).
- Dismantle the mains supply cable max. 80 mm.
- Lead mains supply cable through the cable entry into the luminaire housing.
- Fix the luminaire housing with enclosed or any other suitable fixing material onto the mounting surface.
- It is imperative to use the enclosed gaskets.
- Make an earth conductor connection.
- Push silicone sleeves over the lines and make an electrical connection.
- Make an earth connection between LED module and luminaire housing (plug connection).
- Push LED-plugs into couplers as far as it will go.
Assemble LED module.
Tighten the screws evenly (max. 0,8 Nm). Please observe that the LED module is
not damaged mechanically. Place glass to the luminaire housing with sliding
bolt glass closure and observe that the holding spring bolts fit into the
notches of the glass.
IMPORTANT!
- The glass must be turned clockwise past the first instance of palpable spring resistance.
- By continuing to turn the glass, the glass retaining spring enters the “resting zone” of the glass. The end position of the glass is reached via a palpably firm stop
- Thus, you reach a safe and vibration-resistant holding of the glass.
- To release the glass from the luminaire housing, turn it counterclockwise.
Replacement of the LED module Maintenance
- The designation of the LED module is noted on a label in the luminaire.
- The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted. The module can be replaced by qualified persons using standard tools.
- Disconnect the system.
- Unscrew the glass from the luminaire housing by turning it counterclockwise.
- Clean glass and luminaire regularly with solvent-free cleansers from dirt.
- Please follow the installation instructions for the LED module.
- Screw in the glass by turning it clockwise as far as it will go.
- A broken glass must be replaced
Spares
- Spare glass 11 002 771 .0R G
- LED power supply unit DEV-0291/850
- LED module 3000 K LED-0570/930
- LED module 4000 K LED-0570/940
BEGA Gantenbrink-Leuchten KG
Postfach 31 60
58689 Menden
info@bega.com · www.bega.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>