BEGA 50036PK27 Ceiling and Wall Luminaire Instruction Manual

June 1, 2024
BEGA

BEGA 50036PK27 Ceiling and Wall Luminaire

BEGA 50036PK27 Ceiling and Wall Luminaire

Dimension

Ceiling and wall luminaire for indoor use
Dimension

Instructions for use

Application
Ceiling and wall luminaire · indoor luminaire made of hand-blown opal glass and metal housing, for all lighting tasks. They are ideal for places where a soft and uniform lighting distribution is required.

Product description

Metal housing, finish colour white
Impact resistant synthetic diffuser, white,
with bayonet closure 2 mounting holes ø 5.5mm
Distance apart 230mm
2 cable entries for through-wiring for mains cable up to ø 10,5 mm max. 5 x 1.5@
Connection terminal 2.5@
Earth conductor connection
Complies with flicker requirements in accordance with IEEE 1789,
DIN IEC/TR 63158, DIN IEC/TR 61547-1
LED power supply unit 220-240 V x 0/50-60 Hz
DALI-controllable
Number of DALI addresses: 0
Basic insulation is provided between the mains and control cables
BEGA Thermal Control®
Temporary thermal regulation to protect temperature-sensitive components without switching off the luminaire
Safety class I
Impact strength IK10
Protection against mechanical impacts < 20 joule
Safety mark
  Conformity mark
Weight: 2.0 kg
This product contains light sources of energy efficiency class(es) D, E

Safety

The installation and operation of this luminaire are subject to national safety regulations.
Installation and commissioning may only be carried out by a qualified electrician.
The manufacturer accepts no liability for damage caused by improper use or installation.
If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Overvoltage Protection

The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against
e.g. transients, etc. we recommend separate overvoltage protection components.
You can find them on our website at www.bega.com.

Lamp

Module connected wattage 26.4 W
Luminaire connected wattage 29.4 W
Rated temperature ta=25 °C
Ambient temperature ta max=50 °C

50 036 PK27

Colour temperature 2700 K
Colour rendering index CRI >90
Module luminous flux 3845 lm
Luminaire luminous flux 3276 lm
Luminaire luminous efficiency 111,4 lm/W

50 036 PK3
Colour temperature 3000 K
Colour rendering index CRI >90
Module luminous flux 3970 lm
Luminaire luminous flux 3384 lm
Luminaire luminous efficiency 115,1 lm/W

50 036 PK4
Colour temperature 4000 K
Colour rendering index CRI >90
Module luminous flux 4135 lm
Luminaire luminous flux 3522 lm
Luminaire luminous efficiency 119,8 lm/W

Luminaire with trim ring:
Before installing onto the mounting surface the luminaire housing must be inserted into the trim ring (accessory).

Installation

LED are high-quality electronic components!
Please avoid touching the light output opening of the LED directly during installation or revamping.
Pass the mains supply cable through the grommet into luminaire housing.
Fix luminaire housing with enclosed or any other suitable fixing material on to the mounting surface.
It is imperative to use the enclosed gaskets.
Dismantle the mains supply cable approx. 60 mm.
Make earth and electrical connection to the terminals.
For digital control please use the connecting terminal DA, DA.
In case this terminal is not used the luminaire will be operated at full light output.
Place glass to the luminaire housing and observe that the cam pins fit into the notches of the glass.
Screw in glass by turning it clockwise. Thus, you reach a safe and vibration- resistant holding of the glass.

To release the glass from the luminaire housing turn it counter-clockwise.

Replacement of the LED unit

The designation of the LED unit is noted on a label in the luminaire.
The light colour and light output of BEGA replacement units correspond to those of the
LED units originally fitted. The LED unit can be replaced by qualified persons using standard tools.
Disconnect from main supply.
Unscrew synthetic diffuser from luminaire housing by turning it counter- clockwise.
Disassemble LED unit.
Assemble LED replacement unit.
Note installation instructions of the LED unit.
Screw in synthetic diffuser by turning it clockwise.
A damaged synthetic diffuser must be replaced.

Accessory · Trim rings

For this luminaire metal trim rings in 3 enamel surfaces are optional available.
Trim rings are accessories and must be ordered separately

Spares

Colour white 13 004
Colour palladium 13 005
Colour glossy silver 13 006

Spares
Synthetic cover 15 000 456
LED unit 2700 K 75 005 349 K27
LED unit 3000 K 75 005 349 K3