Bega 50 035 Ceiling and Wall Luminaire For Indoor Use Instruction Manual

June 1, 2024
BEGA

50 035 Ceiling and Wall
Luminaire For Indoor Use
Instruction Manual Technical amendments reserved
50 035
Ceiling and wall luminaire for indoor use

50 035 Ceiling and Wall Luminaire For Indoor Use

Bega 50 035 Ceiling and Wall Luminaire For Indoor Use -
fig

Instructions for use

Application

Ceiling and wall luminaire · indoor luminaire made of hand-blown opal glass and metal housing, for all lighting tasks. They are ideal for places where a soft and uniform lighting distribution is required.

Product description

Metal housing, finish colour white Hand-blown opal glass, satin matt, with bayonet closure 2 mounting holes ø 5.5 mm
Distance apart 230 mm
2 cable entries for through-wiring for mains cable up to ø 10,5 mm max. 5 x 1.5@ 3-pole plug connection with connecting terminal and earth conductor terminal 2.5@
2-pole connection for digital control LED power supply unit 220-240 V x 0/50-60 Hz
DALI-controllable
Number of DALI addresses: 1
Basic insulation is provided between the mains and control cables
BEGA Thermal Switch®
Temporary thermal shutdown to protect temperature-sensitive components Safety class I
Impact strength IK05
Protection against mechanical impacts < 0.7 joule
– Safety mark
****– Conformity mark
Weight: 3.2 kg
This product contains light sources of energy efficiency class(es) D, E

Safety

The installation and operation of this luminaire are subject to national safety regulations.
Installation and commissioning may only be carried out by a qualified electrician.
The manufacturer accepts no liability for damage caused by improper use or installation.
If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Overvoltage protection

The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e. g. transients, etc. we recommend separate overvoltage protection components.
You can find them on our website at www.bega.com.
Lamp

Module connected wattage 16.4 W
Luminaire connected wattage 19.6 W
Rated temperature ta= 25 °C
Ambient temperature ta max a= 30 °C

50 035 K27

Colour temperature 2700 K
Colour rendering index CRI > 90
Module luminous flux 2335 lm
Luminaire luminous flux 1423 lm
Luminaire luminous efficiency 72,6 lm / W

50 035 K3

Colour temperature 3000 K
Colour rendering index CRI > 90
Module luminous flux 2415 lm
Luminaire luminous flux 1473 lm
Luminaire luminous efficiency 75,2 lm / W

50 035 K4

Colour temperature 4000 K
Colour rendering index CRI > 90
Module luminous flux 2510 lm
Luminaire luminous flux 1531 lm
Luminaire luminous efficiency 78,1 lm / W

Luminaire with trim ring:
Before installing onto the mounting surface the luminaire housing must be inserted into the trim ring (accessory).

Installation

LED are high-quality electronic components!
Please avoid touching the light output opening of the LED directly during installation or relamping.
Pass the mains supply cable through the grommet into luminaire housing.
Fix luminaire housing with enclosed or any other suitable fixing material on to the mounting surface.
It is imperative to use the enclosed gaskets.
Dismantle the mains supply cable approx. 60 mm.
Make earth and electrical connection to the terminals.
For digital control please use the connecting terminal DA, DA.
In case this terminal is not used the luminaire will be operated at full light output.
Place glass to the luminaire housing and observe that the cam pins fit into the notches of the glass.
Screw in glass by turning it clockwise. Thus, you reach a safe and vibration- resistant holding of the glass.
To release the glass from the luminaire housing turn it counter-clockwise.
Replacement of the LED unit
The designation of the LED unit is noted on a label in the luminaire.
The light colour and light output of BEGA replacement units correspond to those of the LED units originally fitted. The LED unit can be replaced by qualified persons using standard tools.
Disconnect from main supply.
Unscrew glass from luminaire housing by turning it counter-clockwise.
Replace the LED unit.
Screw in glass by turning it clockwise.
Defective glass must be replaced.

Accessory · Trim rings

For this luminaire metal trim rings in 3 enamel surfaces are optional available.
Trim rings are accessories and must be ordered separately.

| Part. No
---|---
Colour white| 13 004
Colour palladium| 13 005
Colour glossy silver| 13 006

Spares

Spare glass 11 003 180 .0R G
LED unit 2700 K 75 001 904 .1K 27
LED unit 3000 K 75 001 904 .1K 3
LED unit 4000 K 75 001 904 .1K 4

BEGA Gantenbrink-Leuchten KG
· Postfach 31 60
· 58689 Menden
· info@bega.com
· www.bega.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals