Product Information
Specifications:
- Manufacturer: DELTA-OPTI Monika Matysiak
- Model: RG-EST350 V2 Wireless Bridge
- Power Supply: 24V/0.5A PoE
- Power Adapters: 24V/0.5A PoE, 12V/1A DC
- Max PoE Distance: 100m (Cat5e/6/6a/7/8 Cable)
Product Usage Instructions
Package Contents:
The package includes the necessary components for setting up the wireless
bridge:
- 2 x RG-EST350 V2 Wireless Bridges
- 8 x Phillips Pan Head Screws (ST4.2X19)
- 2 x Hose Clamps
Plugging the Ports:
Connect the LAN1/PoE port at the NVR end and Camera end using the provided PoE
power adapters. Ensure the maximum distance for PoE is within 100m using
compatible cables.
Installing the Device:
Pole Mounting:
- Assemble the mount kit.
- Secure the device on a pole using hose clamps.
- Adjust orientation as needed.
Wall Mounting:
- Drill holes at marked positions and insert wall anchors.
- Assemble the mount kit.
- Secure the device on the wall and adjust orientation.
Managing the Device:
App Management (Recommended):
Use the provided App to manage the wireless bridges. Scan the QR code to
download the App and follow instructions to set up the device.
Web Management:
To manage via web interface, connect to the SSID or plug an Ethernet cable
into the LAN port. Visit http://10.44.77.254 and set your computer’s IP
address to 10.44.77.250 for configuration.
Frequently Asked Questions (FAQ)
-
Q: How do I reset the device to factory settings?
A: Press the reset button for over 5 seconds to restore the device to factory settings. -
Q: What is the default power supply for RG-EST350 V2? A: RG-EST350 V2 adopts a 24V/0.5A PoE power supply.
Manufactured in China for: DELTA-OPTI Monika Matysiak, 60-713 Poznan, 10 Graniczna St., Poland www.shopdelta.eu
RG-EST350-V2 Wireless Bridge User Manual
Note
The device and software may update without prior notification. Please contact
Ruijie technical support for details.
Before You Begin
Package Contents
Management software WSP-EST350 V2 has been installed on the device.
Part Description | Qty |
---|---|
RG-EST350 V2 Wireless Bridges | 2 |
Phillips Pan Head Screws (ST4.2X19) | 8 |
Hose Clamps | 2 |
Mounting Brackets | 2 |
Universal Joint Assemblies | 2 |
Universal Joint Nuts | 2 |
RG-EST350 V2 Product Manual | 1 |
24V/0.5A PoE Power Adapters | 2 |
Wall Anchors | 6 |
Power Cord | 2 |
Warranty Card | 1 |
Networking
LED & Ports
Description
-
LED
-
a. SYS LED
Blinking: The system is initializing, restoring factory settings, upgrading or resetting.
On: The device is working properly.
Off: The device is not powered on. -
b. LAN1/LAN2 LED
Off: The LAN port is not connected.
Blinking Green: Link is up. The port is sending or receiving data. Solid Green: Link is up. The port is not sending or receiving data. -
c. Signal LED (STR1/STR2/STR3)
STR1 Blinking/On: The device is bridged.
STR1 On: RSSI > -75 dBm
STR1 On + STR2 Blinking: RSSI > -73 dBm
STR1 On + STR2 On: RSSI > -71 dBm
STR1 On + STR2 On + STR3 Blinking: RSSI > -68 dBm
STR1 On + STR2 On + STR3 On: RSSI > -64 dBm
-
-
12V DC Port
RG-EST350 V2 adopts 12 V/1 A DC power supply. -
LAN2
-
LAN1/PoE Port
RG-EST350 V2 adopts 24 V/0.5 A PoE power supply. -
Reset Button
Press the button for 2 seconds, and the device will be rebooted. Press the button for over 5 seconds, and the device will restore thefactory settings.
Plugging the Ports
NVR End
Camera End
Installing the Device
Pole Mounting
- Assemble the mount kit.
- Secure the device on a pole by using a hose clamp.
- Adjust the orientation.
Wall Mounting
- Drill holes into the marked positions and insert wall anchors.
- Assemble the mount kit.
- Adjust the orientation.
Managing the Device
App Management (Recommended)
The wireless bridges are used in pairs without extra configuration. You can
scan the following QR code to download an App to manage the bridges.
Navigate to Project > + Create a Project > Scan QR-code to manage the device.
Web Management
Connect to the SSID (Default: @Ruijie-bxxx. xxxx indicates the last four
digits of the MAC address) or plug an Ethernet cable into the LAN port, and
then visit http://10.44.77.254. It is recommended to set the IP address of
computer to 10.44.77.250.