Specifications

  • 100A MAXBAR+ 1P, 8 MOD
  • 100A MAXBAR+ 3P, 18 MOD
  • Terminal Block, 100A, 1P
  • Terminal Block, 100A, 1P
  • Curve, 6000A, 240/415V, RED
  • Curve, 6000A, 415V, RED
  • Toggle 1P, 32A, C
  • Toggle 1P, 32A, C
  • Curve, 6000A, 240/415V
  • Curve, 6000A, 240/415V
  • 30mA, C Curve, 6000A
  • 30mA, C Curve, 6000A

Product Usage Instructions

Unboxing

  • When unboxing the Protection Kit, ensure all components are present based on the commercial reference numbers provided in the manual.

Description

  • For single-phase installations, use the components provided including the MAXBAR+, Terminal Block, Curve modules, and Comb busbar Tooth Cap as specified in the manual.

Three Phase

  • For three-phase installations, utilize the MAXBAR+ 3P, Terminal Block, Curve modules, and Comb busbar Tooth Cap as outlined in the manual.
  • Note: Ensure to follow the specified positions for device installation to prevent unintended equipment operation.

Additional Information

  • Circuit protection devices for SPD are sold separately.
  • The last module can be used for a sub-board or a second solar connection if no AC-coupled battery connection is required.

FAQ

Q: What should I do if I notice damage while unpacking the product?

A: If you observe any damage during unpacking, do not install the product and contact the supplier for further assistance.

Q: Can MCBs be replaced with an isolator switch or terminal block?

A: No, do not replace MCBs with isolator switches or terminal blocks as it could result in device damage and potential hazards.

SAFETY INSTRUCTION

PLEASE NOTE

  • This equipment must be installed and maintained by a qualified electrician under the appropriate statutory regulations and codes of practice.
  • All applicable local, regional, and national regulations must be complied with during the installation, use, maintenance, and replacement of this device.
  • This product should not be installed if, when unpacking it, you observe that it is damaged.
  • Clipsal cannot be held responsible in the event of non-compliance with the instructions in this document and in the documents to which it refers.
  • The service instruction must be observed throughout the lifetime of this product.

DANGER HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH

  • Turn off all power supplying this product before working on it.
  • Use a voltage tester with a suitable rated voltage to check that all active conductors are not energized.
  • Do not cut the comb busbar.
  • Failure to follow these instructions will result in death or serious injury.

WARNING HAZARD OF DEVICE DAMAGE

  • Ensure all the connected sources do not exceed 100 A at any one time.
  • Do not replace MCBs with an isolator switch or terminal block.
  • Failure to follow these instructions will result in death or serious injury.

TOOLS

Unboxing

CLIPSAL-MX9K108PP-Protection-Kit-FIG-2

Description

Single Phase

  • A 100A MAXBAR+, 1P, 8 MOD
  • B MX9TB1100
  • C MX9MC163R
  • D MX9R3240
  • E MX9MC132

Three Phase

  • A 100A MAXBAR+, 3P, 18 MOD
  • B MX9TB1100
  • C MX9MC363R
  • D MX9R3540
  • E MX9MC325
  • F MX9MC132

WARNING UNINTENDED EQUIPMENT OPERATION

  • Ensure that the devices are in specified positions only.
  • Failure to follow these instructions can result in death, serious injury, or equipment damage.

Single Phase Comb Busbar

  • В МХ9ТВ1100
  • C MX9MC163R
  • D MX9R3240
  • E МХ9МС132
  • G MX9MC140 + MX9SP140
  • Circuit protection devices and SPD are sold separately from this kit.
  • The last module can used for either a sub-board or 2nd solar connection if no AC-coupled battery connection is required.
  • Circuit protection device for SPD
  • Neutral connection
  • Grid connection
  • House connection
  • EV connection
  • Solar connection
  • AC coupled battery

For more information on SPD selection & connection, consult the SPN installation sheet. CLIPSAL-MX9K108PP-Protection-Kit-
FIG-13

Three-Phase Comb BusbarCLIPSAL-MX9K108PP-Protection-Kit-
FIG-14

  • B MX9TB1100
  • C MX9MC363R
  • D MX9R3540
  • E MX9MC325
  • F MX9MC132
  • The last module can used for either a sub-board or 2nd solar connection if no AC-coupled battery connection is required.
  • Neutral connection
  • Grid connection
  • House connection
  •   EV connection
  •   Solar connection
  • AC coupled battery

Installation of Devices

CLIPSAL-MX9K108PP-Protection-Kit-FIG-15

Note: For more information, refer to the respective device instruction sheets and technical data sheets.

Installation of Comb Busbar

Single PhaseCLIPSAL-MX9K108PP-Protection-Kit-FIG-16

Note: Remove the protection film from the busbar before installation of busbar.CLIPSAL-MX9K108PP-Protection-Kit-FIG-17

Three PhaseCLIPSAL-MX9K108PP-Protection-Kit-FIG-18

Note: Remove the protection film from the busbar before installation of busbar.CLIPSAL-MX9K108PP-Protection-Kit-FIG-19

Installation of Toothcap for MX9K108PP, MX9K318PPCLIPSAL-MX9K108PP-
Protection-Kit-FIG-20

Note: For unused tooths on the busbar install tooth caps. (Commercial reference number: RMXPT120).

Typical System Representation

Single Phase InstallationCLIPSAL-MX9K108PP-Protection-Kit-
FIG-21

Three Phase InstallationCLIPSAL-MX9K108PP-Protection-Kit-
FIG-22

Additional Technical Information

  • For more information on additional applications, enclosure compatibility, and FAQs, consult the complimentary guide.

Labeling

Single PhaseCLIPSAL-MX9K108PP-Protection-Kit-FIG-23

Three PhaseCLIPSAL-MX9K108PP-Protection-Kit-FIG-24

Single Phase LabelCLIPSAL-MX9K108PP-Protection-Kit-
FIG-25

Note: If there is no AC-coupled battery connection, apply a spare label to the last module for 2nd solar connection or subboard if required.

Three Phase LabelCLIPSAL-MX9K108PP-Protection-Kit-
FIG-26

Note: If there is no AC-coupled battery connection, apply the spare label to the last module for 2nd solar connection or subboard if required.

Testing of RCBO

Single Phase

Note: Test the device at regular intervals by pressing the Test button (marked T), following the intervals defined in your local regulations or monthly.

Three Phase

Note: Test the device at regular intervals by pressing the Test button (marked T), following the intervals defined in your local regulations or monthly.CLIPSAL-MX9K108PP-Protection-Kit-FIG-28

How to Get the Latest Instruction SheetCLIPSAL-MX9K108PP-Protection-Kit-
FIG-30

  • To get the latest instruction sheets for the device:

  • either scan the QR code on this document.

  • or search for the document references MX9K108PP or MX9K318PP on www.clipsal.com

  • Contact your local support to get a printed copy of the latest instruction sheet.

  • For more information, consult www.clipsal.com/support.

  • Clipsal by Schneider Electric (Australia) Pty Limited 33-37 Port Wakefield Road

  • Gepps Cross

  • South Australia 5094

  • Customer Care Centre

  • Tel: 13 73 28
    Email: customercare.au@se.com

  • Fax: 1300 369 288

  • www.clipsal.com

  • Printed on recycled paper.

  • © 2024 Clipsal Australia Pty Ltd – All rights reserved.

  • The identified trademarks and copyrights are the property of Clipsal Australia Pty Ltd unless otherwise noted.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals