CLIPSAL MX9K108PP Protection Kit Installation Guide

July 17, 2024
CLIPSAL

CLIPSAL MX9K108PP Protection Kit

CLIPSAL-MX9K108PP-Protection-Kit-PRODUCT

Specifications

  • 100A MAXBAR+ 1P, 8 MOD
  • 100A MAXBAR+ 3P, 18 MOD
  • Terminal Block, 100A, 1P
  • Terminal Block, 100A, 1P
  • Curve, 6000A, 240/415V, RED
  • Curve, 6000A, 415V, RED
  • Toggle 1P, 32A, C
  • Toggle 1P, 32A, C
  • Curve, 6000A, 240/415V
  • Curve, 6000A, 240/415V
  • 30mA, C Curve, 6000A
  • 30mA, C Curve, 6000A

Product Usage Instructions

Unboxing

  • When unboxing the Protection Kit, ensure all components are present based on the commercial reference numbers provided in the manual.

Description

  • For single-phase installations, use the components provided including the MAXBAR+, Terminal Block, Curve modules, and Comb busbar Tooth Cap as specified in the manual.

Three Phase

  • For three-phase installations, utilize the MAXBAR+ 3P, Terminal Block, Curve modules, and Comb busbar Tooth Cap as outlined in the manual.
  • Note: Ensure to follow the specified positions for device installation to prevent unintended equipment operation.

Additional Information

  • Circuit protection devices for SPD are sold separately.
  • The last module can be used for a sub-board or a second solar connection if no AC-coupled battery connection is required.

FAQ

Q: What should I do if I notice damage while unpacking the product?

A: If you observe any damage during unpacking, do not install the product and contact the supplier for further assistance.

Q: Can MCBs be replaced with an isolator switch or terminal block?

A: No, do not replace MCBs with isolator switches or terminal blocks as it could result in device damage and potential hazards.

SAFETY INSTRUCTION

PLEASE NOTE

  • This equipment must be installed and maintained by a qualified electrician under the appropriate statutory regulations and codes of practice.
  • All applicable local, regional, and national regulations must be complied with during the installation, use, maintenance, and replacement of this device.
  • This product should not be installed if, when unpacking it, you observe that it is damaged.
  • Clipsal cannot be held responsible in the event of non-compliance with the instructions in this document and in the documents to which it refers.
  • The service instruction must be observed throughout the lifetime of this product.

DANGER HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH

  • Turn off all power supplying this product before working on it.
  • Use a voltage tester with a suitable rated voltage to check that all active conductors are not energized.
  • Do not cut the comb busbar.
  • Failure to follow these instructions will result in death or serious injury.

WARNING HAZARD OF DEVICE DAMAGE

  • Ensure all the connected sources do not exceed 100 A at any one time.
  • Do not replace MCBs with an isolator switch or terminal block.
  • Failure to follow these instructions will result in death or serious injury.

TOOLS

Unboxing

CLIPSAL-MX9K108PP-Protection-Kit-FIG-2

Description

Single Phase

  • A 100A MAXBAR+, 1P, 8 MOD
  • B MX9TB1100
  • C MX9MC163R
  • D MX9R3240
  • E MX9MC132

Three Phase

  • A 100A MAXBAR+, 3P, 18 MOD
  • B MX9TB1100
  • C MX9MC363R
  • D MX9R3540
  • E MX9MC325
  • F MX9MC132

WARNING UNINTENDED EQUIPMENT OPERATION

  • Ensure that the devices are in specified positions only.
  • Failure to follow these instructions can result in death, serious injury, or equipment damage.

Single Phase Comb Busbar

  • В МХ9ТВ1100
  • C MX9MC163R
  • D MX9R3240
  • E МХ9МС132
  • G MX9MC140 + MX9SP140
  • Circuit protection devices and SPD are sold separately from this kit.
  • The last module can used for either a sub-board or 2nd solar connection if no AC-coupled battery connection is required.
  • Circuit protection device for SPD
  • Neutral connection
  • Grid connection
  • House connection
  • EV connection
  • Solar connection
  • AC coupled battery

For more information on SPD selection & connection, consult the SPN installation sheet. CLIPSAL-MX9K108PP-Protection-Kit-
FIG-13

Three-Phase Comb BusbarCLIPSAL-MX9K108PP-Protection-Kit-
FIG-14

  • B MX9TB1100
  • C MX9MC363R
  • D MX9R3540
  • E MX9MC325
  • F MX9MC132
  • The last module can used for either a sub-board or 2nd solar connection if no AC-coupled battery connection is required.
  • Neutral connection
  • Grid connection
  • House connection
  •   EV connection
  •   Solar connection
  • AC coupled battery

Installation of Devices

CLIPSAL-MX9K108PP-Protection-Kit-FIG-15

Note: For more information, refer to the respective device instruction sheets and technical data sheets.

Installation of Comb Busbar

Single PhaseCLIPSAL-MX9K108PP-Protection-Kit-FIG-16

Note: Remove the protection film from the busbar before installation of busbar.CLIPSAL-MX9K108PP-Protection-Kit-FIG-17

Three PhaseCLIPSAL-MX9K108PP-Protection-Kit-FIG-18

Note: Remove the protection film from the busbar before installation of busbar.CLIPSAL-MX9K108PP-Protection-Kit-FIG-19

Installation of Toothcap for MX9K108PP, MX9K318PPCLIPSAL-MX9K108PP-
Protection-Kit-FIG-20

Note: For unused tooths on the busbar install tooth caps. (Commercial reference number: RMXPT120).

Typical System Representation

Single Phase InstallationCLIPSAL-MX9K108PP-Protection-Kit-
FIG-21

Three Phase InstallationCLIPSAL-MX9K108PP-Protection-Kit-
FIG-22

Additional Technical Information

  • For more information on additional applications, enclosure compatibility, and FAQs, consult the complimentary guide.

Labeling

Single PhaseCLIPSAL-MX9K108PP-Protection-Kit-FIG-23

Three PhaseCLIPSAL-MX9K108PP-Protection-Kit-FIG-24

Single Phase LabelCLIPSAL-MX9K108PP-Protection-Kit-
FIG-25

Note: If there is no AC-coupled battery connection, apply a spare label to the last module for 2nd solar connection or subboard if required.

Three Phase LabelCLIPSAL-MX9K108PP-Protection-Kit-
FIG-26

Note: If there is no AC-coupled battery connection, apply the spare label to the last module for 2nd solar connection or subboard if required.

Testing of RCBO

Single Phase

Note: Test the device at regular intervals by pressing the Test button (marked T), following the intervals defined in your local regulations or monthly.

Three Phase

Note: Test the device at regular intervals by pressing the Test button (marked T), following the intervals defined in your local regulations or monthly.CLIPSAL-MX9K108PP-Protection-Kit-FIG-28

How to Get the Latest Instruction SheetCLIPSAL-MX9K108PP-Protection-Kit-
FIG-30

  • To get the latest instruction sheets for the device:

  • either scan the QR code on this document.

  • or search for the document references MX9K108PP or MX9K318PP on www.clipsal.com

  • Contact your local support to get a printed copy of the latest instruction sheet.

  • For more information, consult www.clipsal.com/support.

  • Clipsal by Schneider Electric (Australia) Pty Limited 33-37 Port Wakefield Road

  • Gepps Cross

  • South Australia 5094

  • Customer Care Centre

  • Tel: 13 73 28
    Email: customercare.au@se.com

  • Fax: 1300 369 288

  • www.clipsal.com

  • Printed on recycled paper.

  • © 2024 Clipsal Australia Pty Ltd – All rights reserved.

  • The identified trademarks and copyrights are the property of Clipsal Australia Pty Ltd unless otherwise noted.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals