RAB A22 Field Adjustable Area Light Instruction Manual

June 2, 2024
RAB

RAB A22 Field Adjustable Area Light

RAB-A22-Field-Adjustable-Area-Light-product

Product Information

Specifications

  • Model: A22TM
  • Manufacturer: RAB Lighting
  • Mounting Options: Pole Mount-Adjustable Universal Arm, Slipfitter Mount
  • Compatible Pole Size: Fits 2 3/8 O.D. Tenon

FAQ

  • Q: What should I do if I need further assistance with installation?
    • A: For further assistance with installation or any questions, please contact our Marketing Department at 888-RAB-1000 or email us at marketing@rablighting.com.

RAB Lighting is committed to creating high-quality, affordable, well-designed and energy-efficient LED lighting and controls that make it easy for electricians to install and end users to save energy. We’d love to hear your comments. Please call the Marketing Department at 888-RAB-1000 or email: marketing@rablighting.com

Models

RAB-A22-Field-Adjustable-Area-Light-fig-14

IMPORTANT

READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE. RAB fixtures must be wired in accordance with the National Electrical Code and all applicable local codes. Proper grounding is required for safety. THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED.

WARNING: Make certain power is OFF before installing or maintaining fixture. No user-serviceable parts inside.

CAUTION: For proper weatherproof function all gaskets must be seated properly and all screws inserted and tightened firmly. Apply weatherproof silicone sealant around the edge of the junction box. This is especially important with an uneven surface. Silicone all plugs and unused conduit entries.

POLE MOUNT-ADJUSTABLE

POLE MOUNT-ADJUSTABLE UNIVERSAL ARM

RAB-A22-Field-Adjustable-Area-Light-fig-1

  1. Place the Bolster Plate (provided) inside a Square or Round Pole as shown in Fig. 1, secure the Arm to the pole with (2) Bolts to the Bolster Plate.RAB-A22-Field-Adjustable-Area-Light-fig-2
  2. Open the Arm Cover (Fig. 2) and feed the fixture and supply wires into the Arm Wiring Compartment to make the wire connections as per wiring diagram ( Fig. 15 ). Make appropriate wire connections as per NEC.
  3. To adjust fixture angle, loosen the Locking Bolt as shown in Fig. 2. Swivel fixture to desired angle and tighten Locking Bolt.RAB-A22-Field-Adjustable-Area-Light-fig-3 RAB-A22-Field-Adjustable-Area-Light-fig-4
  4. The graduation of the Adjustable Arm Cover Plate can be used for guidelines to adjust the fixture angle (Fig. 3 and 4). Maximum tilt is ± 60°.

SLIPFITTER MOUNT

(Accessory ordered separately – Model # A22SF, A22SFW, A22SFB)

WARNING: RISK OF SERIOUS INJURY OR DEATH!

DO NOT MOUNT THE SLIPFITTER TO A TENON OR BRACKET THAT IS MORE THAN 20 DEGREES FROM VERTICAL. MOUNTING ANY ANGLE OTHER THAN 0-20 DEGREES INCREASES THE RISK OF DISENGAGEMENT AND/OR FAILURE OF THE SLIPFITTER. INSTALL THE POLE ON A SECURE BASE OR INSTALL THE BRACKET TO A WALL FIRST. THEN PLACE LUMINAIRE ONTO THE POLE OR BRACKET. DO NOT LIFT ASSEMBLED LUMINAIRE OR POLE OR LUMINAIRE & BRACKET. LUMINAIRE OR POLE/BRACKET MAY DISENGAGE.

RAB-A22-Field-Adjustable-Area-Light-fig-5

  1. Remove Adjustable Universal Arm by removing the fixture Securing Screw as shown in Fig. 5.
  2. Separate the Slipfitter assembly by removing the Swivel Bolt as shown in Fig. 6 and feed wires from fixture through Slipfitter. Re-install Swivel Bolt.
  3. Reconnect the Swivel Bolt. Make the necessary connections as per NEC (Fig. 15).RAB-A22-Field-Adjustable-Area-Light-fig-6
  4. The Slipfitter fits a 2 3/8” O.D. Tenon. Place the Slipfitter over the Tenon and secure the fixture with(4) Set Screws on the side of the Slipfitter as shown in Fig. 7.RAB-A22-Field-Adjustable-Area-Light-fig-7
  5. To adjust fixture angle of the Slipfitter, loosen the Swivel Bolt and swivel the fixture to the desired angle. The graduation of the Slipfitter Cover Plate can be used for guidelines to adjust the angle.

WALL MOUNT

(Accessory ordered separately – Model # A22WM, A22WMW, A22WMB)

  1. Remove the Adjustable Universal Arm by removing the fixture Securing Screw as shown in Fig. 4.RAB-A22-Field-Adjustable-Area-Light-fig-8
  2. Separate the Wall Mount Cover from the Wall Mount Box (Fig. 8).
  3. Orient Wall Mount Box so that the “UP” Arrow is facing up as shown in Fig. 9.
  4. Secure the Wall Mount Box to a sturdy surface. Use appropriate hardware for the mounting surface (by others).
  5. Apply weatherproof silicone sealant around the edge of the mounting box and/or junction box. This is especially important with an uneven surface.
  6. Secure the Wall Mount Cover to the fixture with Securing Screw.
  7. Bring the fixture up to the Wall Mount Box and slide the Tether Cable from inside the Wall Mount Cover into the Keyhole Slot (Fig. 7 and 8) for hands free wiring.
  8. Feed supply wires through Wall Mount Box and wire the fixture using suitable wire connectors as per NEC (Fig. 15).RAB-A22-Field-Adjustable-Area-Light-fig-10
  9. Secure the wall Mount Box to the Wall Mount Cover using (4) Set Screws (provided) as shown in Fig. 10.

FIELD ADJUSTMENT

Follow the instructions below to change the fixture Color Temperature (CCT) and/or Power (W) from the factory settings:

  • Factory Settings: A22-70/60/50W   / 70W / 4000K
    • A22-100/80/60W   /    100W / 4000K
    • A22-150/120/100W   /   150W / 4000K
    • A22-150X/120/100W   /   150W / 4000K
    • A22-200/180/160W   /    200W / 4000K
    • A22-320/280/250W   /   320W / 4000K

RAB-A22-Field-Adjustable-Area-Light-fig-11

  1. Locate the Selector Switches on fixture housing as shown in Fig. 11 and remove Plug.
  2. Select Color Temperature (CCT) and/or Power (W) by sliding the respective switch to the desired value (Fig. 12).
  3. After the switches are positioned to the desired setting replace Plug.

LENS ACCESSORY

LENS accessories are sold separately.
(A22-150X (ONLY) includes TYPE III LENS installed, Type IV and Type V LENS included with fixture).

RAB-A22-Field-Adjustable-Area-Light-fig-12

  1. Loosen Captive Screws (2) to open fixture Door Frame as shown in Fig.13 and 14, remove pre-installed Lens and Silicone Gasket (do not discard Gasket).
  2. Insert new Lens and Silicone Gasket, ensure that the Lens and Silicone Gasket are positioned correctly. Close fixture Door Frame and secure with Captive Screws.

MVS MODELS

(optional remote sold separately for custom settings, CAT# MSR1).

Factory Settings

  • Brightness: 100%
  • Hold Time: 1 Minute
  • Daylight: Disabled
  • Sensitivity: 100%
  • Stand-by dimming level: 20%
  • Stand-by time: 1 Minute

DIMMABLE WIRING

0-10V DIMMABLE WIRING

RAB-A22-Field-Adjustable-Area-Light-fig-13

Universal voltage driver permits operation at 120V through 277V, 50 or 60 Hz. Units ordered with /480 suffix are 480V ONLY. For 0-10V dimming follow the wiring directions shown below (Fig. 15).

  1. Connect the black fixture lead to the LINE supply lead.
  2. Connect the white fixture lead to the COMMON supply lead.
  3. Connect the GROUND wire from fixture to supply ground. Do NOT connect the GROUND of the dimming fixture to the output.
  4. Connect the purple fixture lead to the (V+) DIM lead.
  5. Connect the pink fixture lead to the (V-) DIM lead.
  6. Cap the yellow fixture lead, if present. Do NOT connect.

CLEANING & MAINTENANCE

CAUTION: Be sure fixture temperature is cool enough to touch. Do not clean or maintain while fixture is energized.

  1. Clean lens with non-abrasive glass cleaning solution.
  2. Do not open the fixture to clean the LED. Do not touch the LED.

TROUBLESHOOTING

  1. Check that the line voltage at the fixture is correct. Refer to wiring directions.
  2. Is the fixture grounded properly?
  3. Is the photocell, if used, functioning properly?

Note

  • These instructions do not cover all details or variations in equipment nor do they provide for every possible situation during installation, operation or maintenance.

Contacts

Easy Answers

  • Visit our website for product info rablighting.com
  • Tech Help Line Call our experts: 888 722-1000
  • e-mail Answered promptly: sales@rablighting.com
  • Free Lighting Layouts: Answered online or by request

RAB WARRANTY

© 2024 RAB LIGHTING Inc.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals