Translation of the original instructions
WHP 200
WHP200 Preheating Plate 200W
- Display (3-digit 7-segment display)
- “UP” button
- Mains switch
- “DOWN” button
- Optical indication of the state of regulation
- Mains connection
Accessories
Easy fix board holder
Code No.: T0058757875
We thank for the confidence you have shown by purchasing the Weller Heating Plate WHP 200. During manufacture the strictest quality requirements are applied; these assure the correct function of the device and make it possible to obtain optimal soldering results.
**** Attention!
Prior to placing the device in operation, please carefully read these
operating instructions and the safety instructions enclosed. If the safety
instructions are not observed, there is a risk of injury.
The manufacturer accepts no liability for usage other than that described in
the operating instructions or for unauthorised modifications
The WELLER heating plate WHP 200 complies with the EU declaration of
conformity as per the essential safety requirements in the directives
2004/108/EU and 2006/95/EU.
Description
The WHP 200 heating plate is equipped with a 200 W infrared high-temperature lamp and enables the user to preheat electronic assemblies in numerous ways. The hightemperature lamp supplies energy primarily in the wavelength range of 2 – 10 μm and heats modern tools quickly and efficiently. Digital regulation electronics ensure precise temperature behaviour.
Technical data
Dimensions: | 165 x 195 x 70 mm |
---|---|
(W x L x H) | 6,5 x 7,68 x 2,75 inch |
Mains voltage: | 230 V (120 V); 50 Hz (60 Hz) |
Power: | Heating zone 200 W |
Temperature range: | 50°C – 400°C (150°F – 750°F) |
Protection class: | 1 |
Heating zone: | 120 (4,72) x 60 (2,36) mm (inch) |
Placing in operation
Remove all temperature sensitive and flammable objects from the vicinity of
the heating plate. Ensure that the heating plate is switched off. Ensure that
the mains voltage is correct.
Connect the device to the mains (6). Switch on the device at the mains switch
(3). When the device is switched on, a self-test is performed during which all
display elements (1) are operated. The temperature set (setpoint) and the
temperature scale (°C / °F) are then displayed briefly.
The display then switches automatically to the indication of the actual value.
The red dot on the display illuminates (5). This dot is a visual indication of
the state of the regulation. Continuous illumination indicates the system is
warming up.
Flashing indicates that the operating temperature has been reached.
3.1. Adjusting temperature
The digital display (1) normally indicates the actual temperature.
The digital display (1) switches to the current setpoint when the ”UP” or
“DOWN” button (2)(4) is pressed.
The setpoint (flashing indication) can now be changed as required by pressing
or pressing and holding the “UP” or “DOWN” button (2)(4). If the button is
pressed and held down, the setpoint changes quickly. Approx. 2 sec. after the
button is released, the digital display (1) automatically switches back to the
actual value.
3.2. Manual heating shut down (OFF)
The device heating is shut down by simultaneously pressing the “UP” and “DOWN”
buttons. “Off” appears on the display (1).
Error indications on the display (1)
– – – No temperature sensor detected
E10 Maximum housing temperature exceeded
Power-on routine
°C / °F change over
For this purpose the device is first switched off at the mains switch (3).
Press DOWN button (4) and switch on the device.
Keep button pressed until the “°F” appears on the display (1). When the “DOWN”
button is released the setting is saved. Use the same procedure for the change
over to “°C”.
PCB holder
The PCB holder is secured to the housing upper section by the Heizone. For securing, removing or adjusting the PCB holder, release the knurled screws.
Items supplied
WHP 200 heating plate
Mains cable
PCB holder
Operating instructions
Safety information
Subject to technical change without notice!
See the updated operating instructions at www.weller-tools.com.
Symbols
**** CE mark of conformity
British Conformity Mark
Disposal
**** Waste light sources have to be removed from equipment. Check with your
local authority or retailer for recycling advice and collection point.
According to local regulations retailers may have an obligation to take back
waste electrical and electronic equipment free of charge. Your contribution to
re-use and recycling of waste electrical and electronic equipment helps to
reduce the demand of raw materials. Waste electrical and electronic equipment
contain valuable, recyclable materials, which can adversely impact the
environment and the human health, if not disposed of in an environmentally
compatible manner. Delete personal data from waste equipment, if any.
Contaminated filters must be treated as special waste. Dispose of replaced
equipment parts, filters or old devices in accordance with the rules and
regulations applicable in your country.
EC declaration of conformity
We hereby declare that the products described herein comply with the following
guidelines:
2014/35/EU, 2014/30/EU, 2006/42/EG
**** Besigheim,2023-08-28
Philippe Buidin
Managing director
Authorised to compile technical documentation.
SI 2016 No.1101, SI 2016 No.1091, SI 2008 No.1597
Besigheim, 2023-08-28
Philippe Buidin
Managing director
Authorised to compile technical documentation.
Apex Tool Group UK Ltd Registered in England, Company
Number 14127816 Registered Offi ce: 20 Farringdon Street,
8th Floor London, EC4A 4AB, United Kingdom
Weller Tools GmbH
Carl-Benz-Straße 2, 74354 Besigheim, Germany
Circuit Diagram
Product Registration
www.weller-tools.com/registration
GERMANY
Weller Tools GmbH
Carl-Benz-Straße 2
74354 Besigheim
Tel: +49 (0) 7143 580-0| CHINA
Apex Tool Group
Room 302A,
NO 177 Bibo Road
Shanghai, 201202
Tel: +86 (21) 60880288
---|---
THE NETHERLANDS
Apex Tool Group B. V.
Phileas Foggstraat 16
7821 AK Emmen
Te l : +31 (0) 591 66 75 00| GREAT BRITAIN
Apex Tool Group UK Ltd
Registered in England,
Company Number 14127816 Registered Office:
C/O TMF Group 13th Floor, One Angel Court, London,
EC2R 7HJ, United Kingdom
Tel: +44 740 8836 404
USA
Apex Tool Group, LLC.
Weller Professional Tools Division
1000 Lufkin Road
Apex, NC 27539
Te l : +866 – 498- 0484
info@weller-tools.com
www.weller-tools.com
© 2023, Apex Tool Group, LLC.
Weller is a registered Trademark and registered Design of Apex Tool Group,
LLC.
References
- tools.com | Buy Power Tools and Automotive Parts online
- Homepage | Weller Tools
- Weller Product Registration | Weller Tools
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>