iGAGING 100-700-XX-1 OriginCal Absolute Digital Caliper Instruction Manual
- May 15, 2024
- iGAGING
Table of Contents
- iGAGING 100-700-XX-1 OriginCal Absolute Digital Caliper
- Parts
- Specification
- Battery Replacement
- Operations
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
- 100-700-USB: SPC TO USB cable data output kit
- 35-WL-CAD: SPC TO USB wireless dongle data output kit
- 35-BT-28: SPC dongle data output kit to compatible Bluetooth devices
iGAGING 100-700-XX-1 OriginCal Absolute Digital Caliper
Parts
- Measure Beam
- HD LCD Display
- Function Keys
- Battery Compartment
- Locking Screw
- SPC 5-PIN Data Port
- Thumb Roll
- External Measure Jaws
- Internal Measure Jaws
- Depth Measure Rod
- Depth Rod
Specification
- Reading: 0.0005” / 0.01mm
*100-700-33,39: 0.0005” / 0.01mm / Inch 128th - Measuring speed: 3 meter per second
- Protection rating: IP54 splash water and dust protection
- Power: Battery 3V, CR2032; Storage temperature: 0-40°c Operating environment: 0-40°c
Battery Replacement
-
Slide Battery Cover to the right
-
Remove the Battery Rubber Seal
-
Pull out the Battery Tab for battery removal
-
Insert a new CR2032 battery
Make sure the Battery is facing out / up
Make sure the Battery Tab is not interfering with the battery contacts Make sure the top part of the Battery Tab is on top of the battery -
Re-insert the Battery Rubber Seal
-
Slide the Battery Cover to the original position
-
Responsibility recycle the used battery
Item# Range Accuracy
100-700-04 0-4”/0-100mm 0.001”/0.02mm
100-700-06,26,28,34,35,36,38,43 0-6”/0-150mm 0.001”/0.02mm
100-700-08,D08 0-8”/0-200mm 0.0015”/0.03mm
100-700-12,D12 0-12”/0-300mm 0.0015”/0.03mm
100-700-33* 0-6”/0-150mm/128th 0.001”/0.02mm
100-700-37 .79-6”/20-150mm 0.001”/0.02mm
100-700-39* 0-1.45”/0-37mm/128th 0.001”/0.02mm
Operations
- Press Power to switch the gauge ON or Off. Caliper will auto shut-off within 5 minutes of none use.
- Press mm/in to switch the display reading between measuring units: inch, mm, inch fractional (100-700-33,34,35,36,37,38,39 models)
- Press Origin key to reset origin zero. Origin zero is the absolute zero position for the the caliper. Close the Measure Jaws and press the key to set origin zero.
- Press 0/ABS key to switch between absolute / incremental reading.
- Press the key to enter Incremental mode, and “INC” will show on the display. This gives the user the ability to set an incremental zero.
- Press the key again to exit the mode. Normal reading / measuring will resume. “INC” will disappear from the display.
- Battery: 3V CR3023 (1 Piece)
Precautions
- Do not expose the instruments to direct sunlight or cold temperature.
- Do not attempt to disassemble the caliper for extended period of time.
- Avoid exposure to electromagnetic fields.
- Keep dry when not in use.
DATA OUTPUT OPTIONS
-
100-700-USB: SPC TO USB cable data output kit
-
35-WL-CAD: SPC TO USB wireless dongle data output kit
-
35-BT-28: SPC dongle data output kit to compatible Bluetooth devices
Visit www.iGAGING.com for more information.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>