iGAGING 400-QC-05 Check Spindle Square Gauge User Guide

June 2, 2024
iGAGING

iGAGING 400-QC-05 Check Spindle Square Gauge

iGAGING-400-QC-05-Check-Spindle-Square-Gauge-product-
image

Product Information

Specifications :

  • Product Name: Quick Check Spindle Square Gauge
  • Model Number: #400-QC-05
  • Patent: U.S. Pat Pend
  • Spindle Stem Size: 3/8 inch
  • Indicator Bezel Range: 0-0.25
  • Thread Size: #4-48
  • Squareness Error of Graduation: 0.0005
  • Contact Separation: 4 instrument units

Product Usage Instructions

Setting Zero:
Set Zero on surface #400-QC-05 by turning the Bezel of the dial indicators on a flatness surface. Ensure the instrument is mounted carefully on the spindle to minimize run-out error.

Squaring the Instrument:
To ensure squareness, follow the steps below:

  1. Set Zero on the gauge as per the instructions provided.
  2. Place the instrument on a good flatness surface.
  3. Turn the Bezel of the dial indicators to adjust the squareness.

Calibration:
The gauge comes pre-calibrated for easy and fast use. It is advisable to check calibration periodically to maintain accuracy.

Frequently Asked Questions (FAQ):

  • Q: How often should I calibrate the Quick Check Spindle Square Gauge?
    A: It is recommended to calibrate the gauge periodically to ensure accurate measurements. The frequency of calibration may depend on your usage frequency and working conditions.

  • Q: Can the squareness error be adjusted?
    A: The squareness error of the gauge is minimal (0.0005). It is pre- calibrated and generally does not require adjustment. Ensure proper mounting and handling for accurate results.

Quick Check Spindle Square Gauge

PRODUCT MANUAL
This gauge is pre-calibrated for fast and easy use. –

  • Item# 400-QC-05
  • Range: 0-0.25”
  • Graduation: 0.0005”
  • Contact separation: 4”
  • Spindle stem: Ф 3/8
  • Thread size: #4-48
  • Squareness: <=0.0005”iGAGING-400-QC-05-Check-Spindle-Square-Gauge-01

On Machine Surface Setup (Quick Setup)

  • This gauge is pre-calibrated with a squareness within 0.0005”.
  • Set the gauge on the machine surface and both dial will read zero.

On Machine Setup (Complete Setup)

  1. Step 1. Insert the gauge to the spindle
  2. Step 2. Use a marker to mark a dot under the left indicator contact (as a setup reference point); adjust the spindle height till the indicator reads zero.
  3. Step 3. Turn the spindle 180° and let the right indicator contact overlap on the marked dot. The indicator should zero. Otherwise, turn the dial indicator bezel till the indicator needle points to zero. – Gauge setup is completed.iGAGING-400-QC-05-Check-Spindle-Square-Gauge-03
  • X-axis adjustment
    • Turn spindle and let the gauge parallel to the X-axis.
    • Turn the spindle head around B and observe the needle reading of the two indicators; make necessary adjustment until both indicators share the same readings.
  • Y-axis adjustment
    • Turn spindle and let the gauge parallel to the Y-axis.
    • Turn the spindle head around A and observe the needle reading of the two indicators; make necessary adjustment until both indicators share the same readings.

STATE OF CALIFORNIA WARNING:
Cancer and Reproductive Harm
www.P65Warnings.ca.gov

iGAGING – San Clemente – California
Copyright © 2023 iGAGINGiGAGING-400-QC-05-Check-Spindle-Square-
Gauge-04www.iGAGING.com

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals