iGAGING 400-QC-05 Check Spindle Square Gauge
Product Information
Specifications :
- Product Name: Quick Check Spindle Square Gauge
- Model Number: #400-QC-05
- Patent: U.S. Pat Pend
- Spindle Stem Size: 3/8 inch
- Indicator Bezel Range: 0-0.25
- Thread Size: #4-48
- Squareness Error of Graduation: 0.0005
- Contact Separation: 4 instrument units
Product Usage Instructions
Setting Zero:
Set Zero on surface #400-QC-05 by turning the Bezel of the dial indicators
on a flatness surface. Ensure the instrument is mounted carefully on the
spindle to minimize run-out error.
Squaring the Instrument:
To ensure squareness, follow the steps below:
- Set Zero on the gauge as per the instructions provided.
- Place the instrument on a good flatness surface.
- Turn the Bezel of the dial indicators to adjust the squareness.
Calibration:
The gauge comes pre-calibrated for easy and fast use. It is advisable to
check calibration periodically to maintain accuracy.
Frequently Asked Questions (FAQ):
-
Q: How often should I calibrate the Quick Check Spindle Square Gauge?
A: It is recommended to calibrate the gauge periodically to ensure accurate measurements. The frequency of calibration may depend on your usage frequency and working conditions. -
Q: Can the squareness error be adjusted?
A: The squareness error of the gauge is minimal (0.0005). It is pre- calibrated and generally does not require adjustment. Ensure proper mounting and handling for accurate results.
Quick Check Spindle Square Gauge
PRODUCT MANUAL
This gauge is pre-calibrated for fast and easy use. –
- Item# 400-QC-05
- Range: 0-0.25”
- Graduation: 0.0005”
- Contact separation: 4”
- Spindle stem: Ф 3/8
- Thread size: #4-48
- Squareness: <=0.0005”
On Machine Surface Setup (Quick Setup)
- This gauge is pre-calibrated with a squareness within 0.0005”.
- Set the gauge on the machine surface and both dial will read zero.
On Machine Setup (Complete Setup)
- Step 1. Insert the gauge to the spindle
- Step 2. Use a marker to mark a dot under the left indicator contact (as a setup reference point); adjust the spindle height till the indicator reads zero.
- Step 3. Turn the spindle 180° and let the right indicator contact overlap on the marked dot. The indicator should zero. Otherwise, turn the dial indicator bezel till the indicator needle points to zero. – Gauge setup is completed.
- X-axis adjustment
- Turn spindle and let the gauge parallel to the X-axis.
- Turn the spindle head around B and observe the needle reading of the two indicators; make necessary adjustment until both indicators share the same readings.
- Y-axis adjustment
- Turn spindle and let the gauge parallel to the Y-axis.
- Turn the spindle head around A and observe the needle reading of the two indicators; make necessary adjustment until both indicators share the same readings.