ARROW Two Lumen Hemodialysis Catheterization for High Volume Infusions Instruction Manual
- June 13, 2024
- Arrow
Table of Contents
ARROW Two Lumen Hemodialysis Catheterization for High Volume Infusions
Instruction Manual
Contents
- 1: Two-Lumen Catheter‡: 12 Fr. (4.06 mm OD) x 20 cm Radiopaque Polyurethane with Blue FlexTip®, Arrowg+ard® Antimicrobial Surface Treatment
- 1: Spring-Wire Guide,Marked: .035″ (0.89 mm) dia. x 23-5/8″ (60 cm) (Straight Soft Tip on One End – “J” Tip on Other) with Arrow® GlideWheel™ Wire Advancer
- 1: Catheter: 18 Ga. x 2-1/2″ (6.35 cm) Radiopaque over 20 Ga. RW Introducer Needle
- 1: Injection Needle: SafetyGlide™1 25 Ga. x 1″ (2.54 cm)
- 1: Blunt Fill Needle: 18 Ga. x 1-1/2″ (3.81 cm
- 1: Pressure Transduction Probe
- 1: Introducer Needle: Echogenic 18 Ga. x 2-1/2″ (6.35 cm) XTW and 5 mL Arrow® Raulerson Spring Wire Introduction Syringe
- 1: Injection Needle: SafetyGlide™1 22 Ga. x 1-1/2″ (3.81 cm) and 5 mL Luer-Slip Syringe
- 1: Syringe: 3 mL Luer-Lock
- 1: Tissue Dilator: 10 Fr. (3.5 mm) x 10.2 cm
- 1: Tissue Dilator: 12 Fr. (4.0 mm) x 14 cm
- 2: 10 mL Luer-Lock Pre-Filled Saline Syringe
- 1: 5 mL 1% Lidocaine HCl Solution and Alcohol Prep
- 2: 3 mL Applicator 2% CHG and 70% IPA ChloraPrep®2 One-Step Solution with Hi-Lite Orange™ Tint
- 1: Sharps Away® II Locking Disposal Cup
- 1: Sharps Away® Disposal Cup
- 1: Maximal Barrier Drape™ with 4″ fenestration
- 1: Towel
- 1: Needle Holder
- 1: Safety Scalpel: #11
- 1: Checklist/CLIP Sheet
- 1: Sterile Procedure Sign
- 1: Medication Label: 1% Lidocaine
- 2: Gauze Pad: 2″ x 2″ (5 cm x 5 cm)
- 5: Gauze Pad: 4″ x 4″ (10 cm x 10 cm)
- 1: Surgical Apparel: Impervious Gown
- 1: Dressing: Tegaderm®3 CHG 3-1/2″ x 4-1/2″ (8.5 cm x 11.5 cm)
- 1: Transducer Cover: 14 cm x 147 cm
- 1: Surgical Apparel: Mask with Eye Shield
- 1: Surgical Apparel: Bouffant Cap
- 1: Suture: 3-0 Silk with Curved Needle
- 1: Tubing±: 20″ (50 cm) Extension
- 1: HemoHopper® Fluid Receptacle
- 1A trademark of Becton, Dickinson and Company.
- 2A registered trademark of CareFusion or one of its subsidiaries.
±Precaution: Contains Phthalate: DEHP.
Warning: The results of certain animal experiments have shown phthalates
to be potentially toxic to reproduction. Proceeding from the present state of
scientific knowledge, risks for male premature infants cannot be excluded in
the case of long-term exposure or application. Medical products containing
phthalates should be used only temporarily with pregnant women, nursing
mothers, babies and infants. ‡MR Conditional
Not made with natural rubber latex.
Store between 20 – 25°C (68 – 77°F). Arrow International provides the enclosed
medication label(s) for your convenience. Please ensure that these labels are
applied to the correct syringe and corresponding medication.
Contraindications: The Arrow large-bore two-lumen catheter is not designed for
long-term (≥ 30 days) hemodialysis or for use in patients with thrombosed
vessels.
The Arrowg+ard Blue antimicrobial catheter is contraindicated for patients
with known hypersensitivity to chlorhexidine, silver sulfadiazine, and/ or
sulfa drugs.
*Priming Volume
**
Distal: 1.80 mL
Proximal: 1.80 mL
- Priming volumes are approximate and are done without accessories.
Dialysis Flow Rate†
Flow (mL/min) † In vitro tests performed using 3: 1 glycerine/saline at
37°C.
Symbols
Documents / Resources
|
ARROW Two Lumen Hemodialysis Catheterization for High Volume
Infusions
[pdf] Instruction Manual
CDC-25122-XCN1A-U, Two Lumen Hemodialysis Catheterization for High Volume
Infusions, Two Lumen Hemodialysis Catheterization, Hemodialysis
Catheterization for High Volume Infusions, High Volume Infusions Hemodialysis
Catheterization, Hemodialysis Catheterization, Hemodialysis, Catheterization
---|---
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>