BOSCH EasyControl Adapter Installation Guide

June 12, 2024
Bosch

BOSCH-logo

BOSCH EasyControl Adapter

BOSCH-EasyControl-Adapter-product

Product Information

  • Product Name: EasyControl Adapter
  • Model Number: 6720888197 (2019/07)

Product Features

  • Easy to install and use
  • Compatible with EMS/iRT systems
  • Supports OpenTherm functionality
  • Can be used with Bosch and Buderus products
  • LED indicators for easy status monitoring

Product Specifications

Parameter Value
Power Supply 230 VAC, 50-60 Hz
Maximum Power Consumption 20 W
Output Power (EMS) 3 W
Dimensions (L x W x H) Not specified
Weight 230 g
Operating Temperature Range 0°C to 50°C
Operating Humidity Range 10% to 90%
IP Rating IP20

Product Usage Instructions

  1. Before installation, ensure that the power supply is disconnected.
  2. Connect the EasyControl Adapter to your EMS/iRT system according to the provided wiring diagram.
  3. If using OpenTherm functionality, ensure that the appropriate connections are made.
  4. Connect the EasyControl Adapter to the EasyControl unit using the provided cables.
  5. Once all connections are made, power on the EasyControl Adapter and verify that the LED indicators are functioning correctly.
  6. Follow the instructions provided with your EMS/iRT system or EasyControl unit for further configuration and usage.
  7. If any issues occur, refer to the troubleshooting section in the user manual or contact customer support for assistance.

Safety instructions

The maximum power consumption of the connected components and assemblies must not exceed the power output stated in the specifications for this module.

  • Avoid high ambient temperatures (table 2).
  • Avoid moisture and a dusty atmosphere.
  • Prevent short circuit or damage to the product.
  • Before starting the installation, switch off the boiler mains voltage.
  • Only use the provided cables.
  • Only clean the product with a dry cloth.
  • Incorrect connection of this product can cause damage to the unit. The unit must therefore only be installed by an approved contractor.
    • Depending on which signal is connected to the potential contact, there is a danger of electric shock.

Product Information

This product provides communication between a boiler without an EMS function (Energy Management System) and:

  • a thermostat with an EMS interface,
  • a function module.

This product converts the following protocols to EMS and viceversa:

  • iRT (Intelligent Room Thermostat) for UBA (universal burner control unit) 1.5,
  • OpenTherm®, version 4.0 or higher,
  • zero volt on-off switching contact.

Functional capability can be lost, if protocols are converted. This product can also be used to increase the electrical output of an EMS/iRT bus.

The standard delivery consists of

BOSCH-EasyControl-Adapter-fig-1

  1. EasyControl adaptor
  2. screw with rawl plug (2x)
  3. technical documentation
  4. power adaptor

This product has the following connection possibilities

  1. room thermostat1)
  2. function module
  3. mains voltage
  4. power adaptor
  5. EasyControl adaptor
  6. zero volt contact
  7. function module
  8. other units
  9. EMS or iRT or OpenTherm bus or on-off
  10. boiler

This product has a warranty period of 2 years. This product is in accordance in design and operation with the European Directives and the supplementary national requirements. The conformity is indicated by the CE mark. You can ask for a copy of the declaration of conformity for this product. For this see the contact address on the back cover of these instructions.

Environmental protection/disposal

Environmental protection is a key company principle for the Bosch Group. Product quality, economical profitability and environmental protection are equally important to us. We strictly adhere to environmental laws and rules. To protect the environment, we adapt, subject to economical considerations, the best possible technology and materials.

Packaging

In our packaging, we consider all country specific recycling systems to guarantee optimal recycling. All of our packaging materials are environmentally friendly and recyclable.

Old electrical and electronic appliances

Electrical or electronic devices that are no longer serviceable must be collected separately and sent for environmentally compatible recycling (in accordance with the European Waste Electrical and Electronic Equipment Directive).

  1. This product is compatible with Bosch brand, Buderus brand and Worcester smart temperature controllers.
  • To dispose of old electrical or electronic appliances, you should use the return and collection systems put in place in the country concerned.

Assembly

The minimum requirements for installation of this product are:

  • Before installation, check that the combination of the thermostat, the EasyControl adaptor and the boiler is possible.
  • Assembly in bathrooms is not permitted .
  • A 2-wire cable is required for the assembly, see tables in the chapter 7 “Technical data”.
  • Ensure that the cable length between the EasyControl adaptor and the boiler is max. 2 metres, since long data cables can cause faults.
  • Open the EasyControl adaptor casing (fig. 3).
  • Mark the drill holes using the centre distance between the elongated holes.
  • Install the product using the provided screws and rawl plugs.
  • Tighten the screws finger-tight.

Electrical connection

CAUTION: Risk of electric shock.

  • There is the danger of an electric shock, if the unit is touched.

See the installation instructions for the boiler for more information on connecting the thermostat.

Thermostat and boiler connection

The “thermostat” and “boiler” cable clamps are not polarity sensitive.

  • Remove the boiler plug from the socket.
  • Disconnect the thermostat.
  • Connect the part of the 2-wire cable that connects to the thermostat to the “thermostat” cable clamps.

Bus connection

The EMS-bus is connected in the following way (fig. 4):

  1. base plate
  2. thermostat or EMS module(s)
  3. EasyControl adaptor
  4. boiler
  5. boiler 2-wire cable
  6. power adaptor
  7. thermostat 2-wire cable

Zero volt contact

An on-off switching unit can be connected through the zero volt contact (fig. 5):

  1. normally open connection (NO)
  2. normally closed connection (NC)
  3. common (COM)

The default connection is COM-NO. Following a heat demand, the NO contact closes.

  • Close the EasyControl adaptor casing (fig. 6).
  • Connect the power adaptor to the EasyControl adaptor.

Commissioning

  • Position the thermostat.
  • Insert the boiler plug into a socket.
  • Turn on the boiler.
  • Insert the power adaptor into a socket.

The EasyControl adaptor will start initialising (fig. 7).
The steps in table 1 are run through automatically.

Table 1: LED indication during initialisation

#| LED

indication

| The EasyControl adaptor:
---|---|---
1| Flashing red| … is receiving power and is waiting for protocol detection.
2| Flashing blue| … is processing protocol detection.
3| Constantly blue| … has detected a supported protocol and is initialising the internal database.
4| Constantly green| … has received data from the boiler as well as from the thermostat.
5| Dimmed green| … is in operation.

Technical data

Table 2: Technical data, module

Volume Unit Value
Voltage supply VDC 20
Pmax W 3
Pmax out (EMS) W 2.25

Dimensions

(width x height x depth)

| mm| 134× 115× 37
Weight| g| 230
Permissible ambient temperature range| °C| 0 – 50
Max. storage temperature| °C| 0 – 60
Permissible relative humidity (dry mode)| %| 10 – 90
IP classification| IP20

Table 3: Technical data, connections

Volume Unit Value
Cable diameter (min.) mm2 0.2
Cable diameter (max.) mm2 2.5
Cable length (max.) EasyControl adaptor – boiler m 3
Cable length (max.) EasyControl adaptor – thermostat m 100

Table 4: Technical data, volt free contact, DC load

Volume Unit Value
Switching voltage AC (maximum) V 250
Switching current AC (maximum) A 5
Contact load AC (maximum) VA 1250

Table 5: Technical data, volt free contact, AC load

Volume Unit Value
Power supply AC in V 100 – 240
Frequency Hz 50 – 60
Contact load (maximum) @ 240 VAC A 0,32
Power supply DC out V 20
Contact load (maximum) @ 20 VDC mA 300

Table 6: Technical Data, power source

Faults

LED Error Solution
Blinking alternating red and blue No boiler detected.

| Turn on the boiler.

Check the cable clamps between the power adaptor and the connection to the boiler. Check the 2-wire cable.

Refer to the boiler installation instructions.

Constantly red| Short circuit connection to the thermostat.

No communication with the boiler.

| The boiler is turned off:

▶ Turn on the boiler.

▶ Check all connections. The boiler is switched on:

▶ Remove the EasyControl adaptor power adaptor from the socket, wait at least

10 seconds, and reconnect it.

Constantly blue| No communication with the thermostat.| ▶

| Turn on the boiler.

Check the cable clamps between the power adaptor and the thermostat. Check the 2-wire cable to the thermostat.

Out| No power.| ▶

| Connect the EasyControl adaptor power supply.

Replace the power adaptor.