HYDRA DLB-V0001 Zodiac DLB Dynamic Load Balancing Instruction Manual
- May 15, 2024
- HYDRA
Table of Contents
HYDRA DLB-V0001 Zodiac DLB Dynamic Load Balancing
INTRODUCTION
The home load balancer can maintain the dynamic balance of the total household current, to ensure the safety of electricity consumption, and to avoid the overload of household electricity when the charging is charging. A home load balancer consists of a transmitter and a receiver. The transmitter needs to be installed at the main incoming line of the household power supply to transmit the sensed current data to the receiver. The receiving end is located inside the household AC chargepoint (the chargepoint needs to be purchased additionally) and receives the data from the transmitting end.
Size | 90mmX90mmX38mm |
---|---|
Support voltage/current | 1 Phase:230V±10% 50/60Hz,100A |
3 Phase:400V±10& 50/60Hz,100A(per phase)
Interface| Household line transformer interface 3
Indicator light| LED 2 RED+GREEN
Power supply| CT induction power supply
Transfer method| Wireless transmission
Button| Pair key 1
IP| IP31
Operating temperature| -20 °C to +40 °C
Storage temperature| -40 °C to +70 °C
Working humidity| 5%-95% No-condensing
Working altitude| 2000 m
Installation method| Back panel + guide rail/buckle
Transformer installation method| Open lock
She| ll material| | | ABS
| | |
DISCLAIMER OF WARRANTY AND LIMITATION OF LIABILITY
All information, specifications and illustrations in this manual are based on
the latest information available at the time of printing, images and
illustrations depicted in the manual may differ slightly from actual products.
Hydra EVC Ltd reserves the right to make changes at any time without prior
notice. Although this manual has been carefully checked, it does not guarantee
the completeness and correctness of the contents of the manual, including but
not limited to product specifications, functions, illustrations, etc. Before
operating or maintaining this product, please read this manual carefully and
pay special attention to safety warnings and precautions.
Note: This document is intended to guide professional electricians and
installers through the use and on-site installation of the Hydra home dynamic
load balancer. If you use the equipment in a manner other than described in
this manual or other related documents, death, injury and property damage
could occur.
THE TRANSMITTER
- Indicator light
- Pairing button
- Rail buckle
- Guide antenna interface
- RJ45 interface
- DIP switch
- Rubber stopper
- CT interface
- Reserved interface
THE RECEIVER (THE ZODIAC)
INSTALLATION
This device can only be used indoors or inside a cabinet, not outdoors. When selecting an installation site for the device, consider the environmental conditions listed in the table below. Equipment recommended installation environment table.
Ambient temperature | -20°C~+40°C |
---|---|
Altitude | ≤2000m |
Humidity | 5%~95%RH |
Dust | ≤1mg/m3 |
Corrosive substances | Free from pollutants such as salt, acid, smoke, etc. |
Shock | ≤1.5mm/s |
Damp | Rainproof, protection above IPX4 |
Fire protection | No flammables nearby |
- Install the DIN rail on the wall
- Connect the transformer (CT) and antenna
- Connect the transformer (CT) to the main power line of the household, connect the single phase to the L phase line, and connect the three phases to the L1, L2, and L3 phase
- Please refer to the HYDRA ZODIAC installation manual for installation instructions (download from www.hydraev.co.uk/support)
- Connect the transformer (CT) and antenna
PAIRING
SETTING UP THE APP
AFTER THE PAIRING IS COMPLETED
Please scan the corresponding QR code to download the HYDRA HOME app and
complete the registration.
ANDROID IPHONE
Pair the Hydra Home App to the Zodiac Chargepoint and set up according to
instructions in the app
manual:www.hydraev.co.uk/support
Note: Professionals must confirm the maximum load capacity of the family and set the corresponding value. When the household power supply is a single- phase power supply, only one transformer (CT) is used, and the household load balancer starts to work when the total electricity consumption current of the household needs to exceed 20A. When the current is less than 20A, the home load balancer remains off. When the household power supply is a three-phase power supply, three transformers (CT) are used, and the household load balancer starts to work when the total household power current needs to exceed 10A. When the current is less than 10A, the home load balancer remains off.
TROUBLESHOOTING
Fault state | RECOMMENDED TREATMENT |
---|
The equalizer light is off
| Check whether the front-end charging transformer is good or bad and whether the connection is correct; check whether the input current reaches the minimum current value required for work.
The equalizer light is on, but there is no communication
| Check whether the pairing is successful; check whether the distance between
the transmitter and receiver is too far or there are many obstacles; check
whether the charging pile is powered on; check whether the APP is set
correctly.
Still tripping after using the equalizer| Check whether the maximum current
set on the APP is correct.
Unable to pair
| Check whether the pairing operation is correct; check whether the
transmitter and receiver are in pairing mode; check whether the distance
between the transmitter and receiver is too far or there are many obstacles.
Other problems| Please contact our after-sales service.
HYDRA EVC Ltd
Telephone: 01268 205 121
Email: sales@hydraev.co.uk
Unit 11, Totman Close, Rayleigh, Essex SS6 7UZ
DLB-V0001-23/01/2023