PETERMANN PM-1584 Fitted Sheet User Manual
- May 15, 2024
- PETERMANN
Table of Contents
Fitted Sheet Manual
General Information
Thank you for choosing a Petermann product.
Please read the user manual carefully before using the product for the first
time!
The current understanding in modern occupational health and safety is that
people in nursing professions experience significant work-related physical
strain. Back injuries are common. There are many situations in which a patient
has to be transferred from a bed, a wheeled stretcher, ambulance stretcher, an
X-Ray table or a wheelchair to a different stretcher or seat. The strain on
the user and the patient / care-dependent can be reduced significantly through
the use of sliding mats.
The use of transfer aids should be conditional upon the user having learned to
use the equipment properly. The user has to decide for themselves what
equipment is suitable to the patient’s situation and the intended sequence of
movements.
The Sliding Mat Wheelchair is part of a product line which is used
specifically to aid in raising patients who have slid forward in the
wheelchair in home care settings, hospitals and other health care facilities.
The product may only be used for the specified purpose and under the specified
conditions. The Sliding Mats Wheelchair are a safe transfer aid, which allows
for a setup transfer which is pleasant and comfortable for the patient as well
as being simple and back-friendly for the users.
The information in this user manual is for the patient who is being
transferred and moved, as well as the user performing the transfer / position
change.
Contact us if you require additional information or assistance using the
Petermann product.
1.1 Product versions
Item no.: PM-1584 (for mattress size: 2000 x 900 mm)
1.2 Accessories
No accessories are available for this device.
1.3 Scope of delivery
Fitted Sheet
User manual
1.4 Storage, transport
Store/transport
at -5°C – 40°C Other: protect from sunlight
1.5 Service life / lifecycle
If the product is used in accordance with the safety instructions, then the
expected product service life is five years. However, the effective service
life may vary depending on the frequency and intensity of use and the number
of washing and disinfection cycles. Perform regular function checks on the
product and be sure to observe the safety information (see item 2).
Safety information
WARNING indicates a potential danger which could lead to personal injury
or material damage.
➢ It is the responsibility of the organisation / the user to determine, on the
basis of the circumstances (weight / health condition of the patient) and the
capabilities of the user, whether several users may be required for the
transfer and/or whether additional safety measures are required.
➢ Defective products may no longer be used.
➢ The smooth surfaces significantly reduce resistance due to friction during
repositioning. Check the transfer surfaces carefully to ensure they are fixed
in place securely (e.g. wheelchair, bed).
➢ Make sure that the mattress size is suitable for our product, otherwise the
anti-slip strips lose their non slip effect. => At smaller mattresses, the
anti-slip strips are not on the top side!
➢ Ensure that the transfers are performed by the users in a back-friendly
manner.
➢ In case of direct skin contact, observation of changes in skin appearance is
indicated.
➢ Weight limits must be observed (200 kg).
➢ Transfer products are subject to a natural ageing process. Inspect the
equipment regularly to ensure proper functionality.
➢ The use of non-standard cleaning agents or bleaching agents, alcohols,
fabric softeners or other chemical laundry additives may lead to permanent
deterioration of the sliding properties.
2.1 Symbols used
| 90°C laundry
---|---
| Do not bleach
| Dry at low temperatures
| Do not iron
| Do not dry clean
| Warning
| Observe the user manual
| Do not use fabric softener
| max. load capacity see item 6
| Manufacturer
| Batch no. / lot no.
| Identification code
| Conformity mark
| Item number
| Medical device label
2.2 Function check
Transfer products are also subject to a natural ageing process. Inspect the
equipment regularly and carefully, in particular before each use.
**| Visual inspection
Ensure that material, seams, handle loops and buckles are undamaged and in
functional order.
---|---
**| Sliding properties
Place the product on a firm surface Pull your hands over the product with
pressure
Good glide – easy gliding Low glide: no gliding/moving possible
**| Anti-slip function**
No anti-slip function: product can be moved Good anti-slip function: Product
cannot be moved
➢ Defective products may no longer be used!
Using the product
3.1 Indication and further use
Due to the wide range of possible applications, the indications cannot be tied
to a specific clinical picture, since the Fitted Sheets in combination with
the turn sheet are suitable for all applications involving people who require
assistance. Thanks to the reduced friction, the capabilities of the patient
can be put to use when Fitted Sheets are used. The effort required on the part
of the user is reduced. The product can be used in combination with the Turn
Sheet in support of the following diagnoses.
➢ For poor skin condition
➢ For large area wounds
➢ With decubitus
➢ For patients with an increased risk of bleeding due to skin contact
➢ For micro position changes
➢ For individually felt pain
➢ To the transfer of overweight patients
➢ As an option for recumbent transfer from bed to an adaptive wheelchair
➢ For mobilisation and positioning of a patient in bed according to
indications
➢ For patients with elevated or reduced muscle tone
➢ For patients unable to move on their own
➢ Can be used with minimal independent patient mobility (e.g. ALS or MS)
➢ To reduce shear and friction forces
➢ Application in palliative settings
➢ A combination of pressure relieving mattresses, pain treatment systems or
alternating pressure mattresses is possible in specific configurations after
testing.
This product may be reused.
Before reusing the product, be sure to perform a thorough function check (see
item 2.2) as well as cleaning or disinfection of the product. (see item 5)
3.2 Contraindications
Contraindications cannot be tied to a specific clinical picture. Under
consideration of the safety information (see item 2), the product may not be
used if the patient has any of the following conditions:
➢ Independent/active patients
➢ Wandering patients
3.3 Application risks
➢ Patients are miscalculatet → risk of falling
➢ The product is embedded incorrectly → risk of falling
3.4 Areas of application
The product can be used in home care and other health care facilities as
well as hospitals.
3.5 Application illustration
3.6 Application
The Fitted Sheet is an accessory item for the Turn Sheet (item no. PM-1582) or
the Turn Sheet with hidden handles (item no. PM-2098). The sliding surface of
the fitted sheet is finished with extremely low-friction sliding material.
The fact that the sliding surfaces of the top sheet and the turn sheet lie
against one another maximises the reduction of friction forces, producing the
same effects as a sliding mat.
3.6.1 Applications: Fitted Sheet as set PM-1695
When using the Fitted Sheet in combination with the turn sheet, anti-slip mat
and a 3-piece bed wedge set (item no.: PM-1695), the following parts are used:
➢ Turn Sheet 3 belt loops at the head end and 12 hidden handle loops
➢ Fitted Sheet with sliding surface and anti-slip safety strip
➢ Anti-Slip Mat and support belts to aid with supporting and positioning
➢ Bed Wedges for positioning the patient
3.6.2 Preparation
➢ Fit the Fitted Sheet onto the mattress like a fitted bed sheet with the
sliding surface facing up.
➢ Tighten it on the sides using the pull cords.
➢ Place the Turn Sheet directly onto the Fitted Sheet.
Visit our website at www.pm-med.de or watch our
comprehensive product videos on our YouTube channel.
https://www.youtube.com/channel/UCZdMwKtd1tGQayGEDHsi7Cg/videos
3.7 Approved accessories, combination with other products
Fitted Sheets are used in combination with the following products:
➢ PM-1582/2098/2099 Turn Sheets
➢ PM-7010/7011 Non-Slip Mats
➢ PM-8010 Bed Wedges
Petermann transfer aids are part of a comprehensive aid product range, which
are effective and back-friendly for the user and comfortable and supportive
for the patients. Additional Petermann products may be used according to the
situation and clinical picture. Ask our experts. We are happy to help you!
3.7.1 Sets
Item No. | Ingredients set |
---|---|
PM-1580 | PM-1582 Turn Sheet |
PM-1584 Fitted Sheet
PM-7010 Non Slip Mat
PM-1685| PM-2098.2 Turn Sheet
PM-2091 Fixing Stripes
PM-1584 Fitted Sheet
PM-7010 Non Slip Mat
PM-1695| PM-2098.2 Turn Sheet
PM-2091 Fixing Stripes
PM-1584 Fitted Sheet
PM-8010 Bed Wedges
PM-7010 Non Slip Mat
PM-1699| PM-2099.1 Turn Sheet
PM-2091 Fixing Stripes
PM-1234 Air Pump
PM-1233 Cover for Air Cushion
PM-1232 Air Cushion
PM-1584 Fitted Sheet
PM-7010 Non Slip Mat
PM-8010 Bed Wedges
Please observe the user manuals of the other items as well.
Product marking / CE
The Petermann Fitted Sheet is a Class I Medical Device and meets the EU- Regulation 2017/745 of the European Parliament and Council dated 05.04.2017 for medical devices, also called MDR. Petermann GmbH is certified in accordance with DIN EN ISO 13485 by TÜV Süd, Medical Devices – Quality management systems applicable to the design and development, production and distribution of aids for people of limited mobility.
Cleaning, care and disinfection
Cleaning | Desinfection (if necessary) |
---|---|
90° washing machine | Recommended disinfectants for wipe disinfection: |
– Trionic® (DGHM/VAH approval, further information on request)
– Mikrobac® Tissues
– Mikrobac ® forte
– Bacillol® 30 Foam
– Bacillol® 30 Tissues
– Bacillol ® 30 Sensitive Tissues
– Mikrobac® Virucidal Tissues
Mild detergent
Do not use cleaning agents with bleaching ingredients or chemical laundry
additives! Otherwise the product properties may deteriorate permanently.
Wash with similar colours only| wipe with a cloth soaked in water after
disinfection to avoid residues or layer build-up. Please always follow the
manufacturer’s manuals for use when wiping disinfection.
Recommended detergent for industrial washing machines:
– – Maximo Liquid as single detergent
Low dryer temperatures (45° – 50° C)
Be sure to follow the care instructions on the label of each product as well as the manuals for use.
Technical Data
Item no. | Material | Colour | Load-bearing capacity |
---|---|---|---|
PM-1584 | Cotton, latex free | cream | 200 kg |
Item no. | Description | Dimensions in mm | Weight |
Weight
---|---|---|---|---
PM-1584| Fitted Sheet| 2000 x 900 x 200 mm| 1440 g| 1440 g
The manufacturing of our products is subject to highest quality standards. Due to usual manufacturing variations published dimensions and further information concerning the condition of the product are defined as target production specifications. Deviations which might occur are monitored by professional quality management procedures and do not represent a reduction in performance of the respective product.
Warranty
➢ The company Petermann warrants that the product is free from defects in
material and workmanship.
➢ The warranty period is 3 years. It does not cover defects attributable to
abrasion, normal wear, improper use or improper cleaning.
➢ The company Petermann is not liable for accidental or consequential injury
or material damage.
Disposal information
There are no specific disposal regulations for Fitted Sheets, they can be disposed of in accordance with applicable national and local regulations.
Petermann GmbH
Waldweg 3
D-91601 Dombühl
Phone: +49 (0) 9868-9339-0
Email:petermann@pm-med.de