General Information
Thank you for choosing a Petermann product.
Please read the user manual carefully before using the product for the
first time!
The current understanding in modern occupational health and safety is that
people in nursing professions experience significant work-related physical
strain. Back injuries are common. There are many situations in which a patient
has to be transferred from a bed, a wheeled stretcher, ambulance stretcher,
an X-Ray table or a wheelchair to a different stretcher or seat. The strain on
the user and the patient / care-dependent can be reduced significantly through
the use of Sliding Mats.
The use of transfer aids should be conditional upon the user having learned to use the equipment properly. The user has to decide for themselves what equipment is suitable to the patient’s situation and the intended sequence of movements.
Sliding Mats are available in various sizes. The choice of Sliding Mat is based on the clinical picture, the supporting surface and the positioning goal. Ask our experts about this. We are happy to help you!
The inner surface of all Sliding Mats is made from particularly low friction
fabric, which allows for easy movement.
The outer surfaces consist of a carbon-fibre reinforced, latex-free material,
which thanks to its liquid-repellent properties is optimal for use in care
settings. The Sliding Mats have soft padding between the surfaces so that the
patient can lie or sit comfortably.
The Sliding Mats are part of a product line which is used specifically to aid in the transfer of patients in home care and other health care facilities, as well as in hospitals.
The product may only be used for the specified purpose and under the specified conditions.
The Sliding Mats are a safe transfer aid, which allows for a transfer which is pleasant and comfortable for the patient as well as being simple and back- friendly for the users.
The information in this user manual is for the patient who is being transferred and moved, as well as the user performing the transfer / position change.
Contact us if you require additional information or assistance using the Petermann product.
1.1 Product versions
Item no.: PM-1010 Sliding Mat PES/Carbon
Item no.: PM-1210 Sliding Mat PES/Carbon
Item no.: PM-1220 Sliding Mat Cotton/natural ticking
Item no.: PM-1215 Sliding Mat PES/Carbon
Item no.: PM-2010 Sliding Mat PES/Carbon
Item no.: PM-2015 Sliding Mat PES/Carbon
Item no.: PM-1420 Sliding Mat Cotton/natural ticking
Item no.: PM-2010 Sliding Mat PES/Carbon
Item no.: PM-2020 Sliding Mat Cotton/natural ticking
Item no.: PM-2015 (2-piece) Sliding Mat PES/Carbon
1.2 Accessories
No accessories are available for this device.
1.3 Scope of delivery
Sliding Mat
User manual
1.4 Storage, transport
Store/transport | at -5°C – 40°C |
---|---|
Other: | protect from sunlight |
1.5 Service life / lifecycle
If the product is used in accordance with the safety instructions, then the
expected product service life is five years.
However, the effective service life may vary depending on the frequency and
intensity of use and the number of washing and disinfection cycles.
Perform regular function checks on the product and be sure to observe the safety information (see item 2).
Safety information
WARNING indicates a potential danger which could lead to personal injury or material damage.
➢ It is the responsibility of the organisation / the user to determine, on the
basis of the circumstances (weight / health condition of the patient) and the
capabilities of the user, whether several users may be required for the
transfer and/or whether additional safety measures are required.
➢ Defective products may no longer be used.
➢ The smooth surfaces significantly reduce resistance due to friction during
repositioning. Check the transfer surfaces carefully to ensure they are fixed
in place securely (e.g. wheelchair, bed).
➢ Ensure that the transfers are performed by the users in a back-friendly
manner.
➢ Weight limits must be observed (200 kg).
➢ After the transfer / repositioning, remove the Sliding Mat from under the
patient. If applicable, ask about products which can also be used for
“bedding” applications.
➢ Transfer products are subject to a natural ageing process. Inspect the
equipment regularly to ensure proper functionality.
➢ The use of non-standard cleaning agents or bleaching agents, alcohols,
fabric softeners or other chemical laundry additives may lead to permanent
deterioration of the Sliding Mat properties.
2.1 Symbols used
| 90°C laundry| | max. load capacity see item 6
---|---|---|---
| Do not bleach| | Manufacturer
| Dry at low temperatures| | Batch no. / lot no.
| Do not iron| | Identification code
| Do not dry clean| | Conformity mark
| Warning| | Item number
| Observe the user manual| | Medical device label
| Do not use fabric softener| |
2.2 Function check
Transfer products are also subject to a natural ageing process. Inspect the
equipment regularly and carefully, in particular before each use.
Visual inspection
Ensure that material, seams, handle loops and buckles are undamaged and in
functional order.| Sliding properties
Place the product on a firm surface
Pull your hands over the product with pressure
Good glide – easy gliding
Low glide: no gliding/moving possible
---|---
➢ Defective products may no longer be used!
Using the product
3.1 Indication and further use
Due to the wide range of possible applications, the indications cannot be
tied to a specific clinical picture, since Sliding Mats are suitable for all
applications involving people who require assistance. Thanks to the reduced
friction, the capabilities of the patient can be put to use when Sliding Mats
are used. The effort required on the part of the user is reduced. You will
find special areas of application for the following products:
PM-1010
➢ Patients whose legs cannot be flexed
PM-2020
➢ Increased rubbing of the heel over the mattress.
This product may be reused.
Before reusing the product, be sure to perform a thorough function check (see
item 2.2) as well as cleaning and disinfection of the product. (see item 5)
3.2 Contraindications
Contraindications cannot be tied to a specific clinical picture. Observe the
safety information under item 2. In the following patient pictures, the use of
the products may have to be avoided:
All Sliding Mats
➢ Individually perceived pain
PM-2010/PM-2020/PM-2015
➢ Patients are unable to actively support the transfer (exception PM-2020 –
scratching your heel)
3.3 Application risks
➢ The movement is performed surprisingly or too quickly → risk of falling,
particularly in the case of anxious patients, attention must be paid to the
patient and his condition
➢ Improper placement → difficult movement
➢ Sliding Mat is too small → resulting in undesirable shear forces.
3.4 Areas of application
The product can be used in home care and other health care facilities as well
as hospitals.
3.5 Application illustration
3.6 Application
Sliding Mats are available in various sizes and versions, the correct size is
determined on the basis of the patient’s functional capacities and the desired
change in position. These are tubular Sliding Mats, where the specified length
is the length of the respective closed side. The inner surface consists of
low friction material. The outer surface consists of carbon-fibre reinforced
latex-free material which has liquid-repellent properties.
The Sliding Mats not only allow the patient to be moved within the bed, they can also be used for many positionchanges and transfers while lying down or sitting. The Sliding Mats PES/Carbon support the movement transitionsand are not intended to remain underneath the patient. They can be combined effectively with a sliding boardturning disc, the raising aid or the support belt. If the patient is intended to continue lying on the product for alonger time, select the corresponding product version made from Cotton/natural thicking. After use, the slidingmats can be hung up by the label.
PM-1010
Placing the Sliding Mat
➢ Place the patient on their side.
➢ Fold the Sliding Mat down halfway on the closed side.
➢ Place the Sliding Mat against the back of the patient, the position may vary
correspondingly.
➢ Place the patient on their back.
➢ Pull the folded over third through sideways underneath the patient.
➢ The patient should be positioned in the centre of the slide sheet.
Moving with the Sliding Mat
The flexibility of the Sliding Mats allows for pulling, pushing and side /
135° positioning.
PM-1210/PM-1220/PM-1215/PM-1420/PM-2010/PM-2020/PM-2015
Placing the Sliding Mat, option A
➢ The Sliding Mat is pushed crosswise under the patient’s pelvis.
Placing the Sliding Mat, option B
➢ Place the patient on their side.
➢ Fold 1/3 of the Sliding Mat down on the side depending on the planned
direction of movement
➢ Place the Sliding Mat against the back of the patient, the position may vary
correspondingly.
➢ Place the patient on their back.
➢ Pull the folded over third through underneath the patient.
➢ The patient should be positioned in the centre of the Sliding Mat.
Moving toward the head
Prerequisites: The legs can be flexed. Use of a non-slip mat is recommended in
this case!
➢ Flex the patient’s legs.
➢ The patient can move up by extending the legs, on their own or with the
user’s assistance.
If the legs cannot be flexed, then an additional Sliding Mat is required.
Moving to the side
Prerequisites: none
The flexibility of the Sliding Mats allows for sideways pulling, pushing and
lateral positioning.
Removal
After positioning has been completed, the Sliding Mat can be removed
without moving the patient.
➢ Support the patient with one hand.
➢ The Sliding Mat can be pulled out from underneath the patient with the other
hand by pulling on the side below.
Visit our website at www.pm-med.de or watch our comprehensive product videos on our YouTube channel.
3.7 Approved accessories, combination with other products
Sliding Mats are used in combination with the following products:
➢ PM-7010/7011 Non-Slip Mats
➢ PM-8010 Positioning Wedges
Petermann transfer aids are part of a comprehensive aid product range, which are effective and back-friendly for the user and comfortable and supportive for the patients. Additional Petermann products may be used according to the situation and clinical picture. Ask our experts. We are happy to help you!
3.7.1 Sets
Item No. | Ingredients set |
---|---|
PM-1010-W | PM-1010 Sliding Mat |
PM-1051.2 Protection Cover
Product marking / CE
The Petermann Sliding Mat is a Class I Medical Device and meets the EU- Regulation 2017/745 of the European Parliament and Council dated 05.04.2017 for medical devices, hereinafter called MDR.
Petermann GmbH is certified in accordance with DIN EN ISO 13485 by TÜV Süd, Medical Devices – Quality management systems applicable to the design and development, production and distribution of aids for people of limited mobility.
Cleaning, care and disinfection
Cleaning | Desinfection (if necessary) |
---|---|
90° washing machine | Recommended disinfectants for wipe disinfection: |
– Trionic® (DGHM/VAH approval, further information on request)
– Mikrobac® Tissues
– Mikrobac® forte
– Bacillol® 30 Foam
– Bacillol® 30 Tissues
– Bacillol® 30 Sensitive Tissues
– Mikrobac® Virucidal Tissues
Mild detergent
Do not use cleaning agents with bleaching ingredientor chemical laundry
additives!
Otherwise the product properties may deteriorate permanently.
Wash with similar colours only| wipe with a cloth soaked in water after
disinfection to avoid residues or layer build-up. Please always follow the
manufacturer’s manuals for use when wiping disinfection.
Recommended detergent for industrial washing machines:
– – Maximo Liquid as single detergent
Low dryer temperatures (45° – 50° C)
Be sure to follow the care instructions on the label of each product as well as the manuals for use.
Technical Data
Item no. | Material | Colour | Load-bearing capacity |
---|---|---|---|
PM-1010 | PES/Carbon, latex free | blue/red | 200 kg |
PM-1051.2 | PES/PU | White | n. A. |
PM-1210 | PES/Carbon, latex free | blue/red | 200 kg |
PM-1251.2 | PES/PU | White | n. A. |
PM-1220 | Cotton/natural ticking, latex free | off-white | 200 kg |
PM-1215 | PES/Carbon, latex free | blue/red | 200 kg |
PM-1420 | Cotton/natural ticking, latexfree | off-white | 200 kg |
PM-2010 | PES/Carbon, latex free | blue/red | 200 kg |
PM-2020 | Cotton/natural ticking, latex free | off-white | 200 kg |
PM-2015 | PES/Carbon, latex free | blue/red | 200 kg |
Item no. | Description | Dimensions in mm | Weight |
--- | --- | --- | --- |
PM-1010 | Sliding Mat | 1900 x 600 x 5 | 950 g |
PM-1051.2 | Protection cover | 1900 x 600 x 0,5 | 200 g |
PM-1210 | Sliding Mat | 1000 x 700 x 5 | 590 g |
PM-1251.2 | Protection cover | 1900 x 600 x 0,5 | 120 g |
PM-1220 | Sliding Mat | 1000 x 700 x 5 | 985 g |
PM-1215 | Sliding Mat | 1100 x 750 x 5 | 660 g |
PM-1420 | Sliding Mat | 1400 x 900 x 5 | 1890 g |
PM-2010 | Sliding Mat | 500 x 600 x 5 | 265 g |
PM-2020 | Sliding Mat | 500 x 600 x 5 | 426 g |
PM-2015 | Sliding Mat (2piece) | 250 x 600 x 5 | 300 g |
The manufacturing of our products is subject to highest quality standards. Due to usual manufacturing variations published dimensions and further information concerning the condition of the product are defined as target production specifications. Deviations which might occur are monitored by professional quality management procedures and do not represent a reduction in performance of the respective product.
Warranty
➢ The company Petermann warrants that the product is free from defects in
material and workmanship.
➢ The warranty period is 3 years. It does not cover defects attributable to
abrasion, normal wear, improper use or improper cleaning.
➢ The company Petermann is not liable for accidental or consequential injury
or material damage.
Disposal information
There are no specific disposal regulations for Sliding Mats, they can be disposed of in accordance with applicable national and local regulations.
Petermann GmbH
Waldweg 3
D-91601 Dombühl
Phone: +49 (0) 9868-9339-0
Email:petermann@pm-med.de
Gleitmatten_2024-01
References
- med.de - Ihr Medizinportal | Chirurgie | Krankheiten | Gesundheit | Arztsuche