Anolis Calumma XS 24 WW LED Lighting User Manual
- July 6, 2024
- ANOLiS
Table of Contents
- Anolis Calumma XS 24 WW LED Lighting
- Product Information
- Product Usage Instructions
- FAQ
- Safety instructions
- Fixture exterior view
- Control and connection
- Installation
- Software update
- Technical specifications
- Cleaning and maintenance
- ChangeLog
- DMX protocol
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Anolis Calumma XS 24 WW LED Lighting
Product Information
Specifications:
- Product: Calumma XS
- Version: 1.16
- Wireless Operation: RF Exposure requirements compliant
- Immunity: EN 55035 Electromagnetic compatibility
- FCC ID : 2A6PL-DMXRDMRW001
- IC: 29573-DMXRDMRW001
Product Usage Instructions
Safety Instructions:
Unauthorized modifications are forbidden for safety reasons. Use original
packaging for transportation. Operate the device as described in the manual to
avoid damages and warranty void. Avoid exposure to high-frequency
electromagnetic fields.
Fixture Exterior View:
- Transparent glass cover
- Mounting yoke
- Tilt adjusting lock
- LED module with heat sink
Control and Connection:
The Calumma XS modules should be connected to the E-Box Remote or E-Box
Remote basic via junction boxes. Operate in Pass-Through mode.
Example of connection with E-box Remote:
Max. 32 Calummas XS can be connected in one string, with a maximum of 40
connected to one E-box Remote/E-box Remote Basic depending on cable length.
Example of connection with E-box Remote Basic:
Combination of Calummas XS and Emineres Remote is possible.
FAQ
Can I connect more than 32 Calummas XS in one string?
No, the maximum number of Calummas XS that can be connected in one string
is 32. The total number depends on the E-box Remote/E-box Remote Basic and
cable length.
FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY BEFORE POWERING OR
INSTALLING YOUR Calumma !
Save it for future reference.
- This device has left our premises in absolutely perfect condition. In order to maintain this condition and to ensure safe operation, it is absolutely necessary for the user to follow the safety instructions and warnings written in this manual.
- The manufacturer will not accept liability for any resulting damages caused by the non-observance of this manual or any unauthorized modification to the device.
- Unauthorized modification will void warranty.
Safety instructions
DANGEROUS VOLTAGE CONSTITUTING A RISK OF ELECTRIC SHOCK IS PRESENT WITHIN THIS UNIT!
- Always disconnect the fixture from power before cleaning, servicing or installing.
- This fixture should be operated only from the type of power source indicated on the marking label. If you are not sure of the type of power supplied, consult your authorized distributor or local power company.
- Always disconnect the fixture from AC power before servicing or cleaning.
- Make sure the power/data cable is not damaged by sharp edges.
- Do not install the unit near an open flame.
- Refer servicing to qualified service personnel.
- Do not connect this fixture to a dimmer pack.
- This fixture falls under protection class III.
- LED light emission. Risk of eye injury. Do not look into the beam from a short distance without suitable protective eyewear. Do not look at LEDs with magnifiers or similar optical instruments that may concentrate the light output.
- The fixture was designed for outdoor use. This fixture must not be used for underwater installation.
- When choosing the installation spot, please make sure that the fixture is not exposed to extreme heat or dust.
- Avoid using the unit in locations subject to possible impacts.
- The fixture body never must be covered with cloth or other materials when the fixture is under operation.
- Only operate the fixture after having checked that the housing is firmly closed and all screws are tightly fastened.
- The fixture becomes hot during operation. Allow the fixture to cool approximately 30 minutes prior to servicing or maintenance.
- Please consider that unauthorized modifications on the fixture are forbidden due to safety reasons!
- Please use the original packaging if the fixture is to be transported.
- If this device will be operated in any way different to the one described in this manual, the product may suffer damages and the warranty becomes void. Furthermore, any other operation may lead to dangers like short-circuit, burns, electric shock etc.
- The product (covers and cables) must not be exposed to a high frequency electromagnetic field higher than 3V/m.
- Immunity of the equipment is designed according to the standard EN 55035 Electromagnetic compatibility of multimedia equipment – Immunity requirements
- Emission of the equipment complies with the standard EN55032 Electromagnetic compatibility of multimedia equipment – Emission Requirements according to class B.
- Contains FCC ID: 2A6PL-DMXRDMRW001
- Contains IC: 29573-DMXRDMRW001
- This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
- Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
- The [Device] wireless operation is safe and complies to RF Exposure requirements.
- This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
Fixture exterior view
- Transparent glass cover
- Mounting yoke
- Tilt adjusting lock
- LED module with heat sink
Control and connection
The Calumma XS modules should be connected to the E-Box Remote or E-Box Remote
basic via junction boxes. The Calumma XS modules have to be operated in Pass-
Through mode.
The E-box Remote has to be switched to the Pass-Through mode.
Example of connection with E-box Remote
Example of connection with E-box Remote Basic
Note. Combination of Calummas XS and Emineres Remote is also possible.
Example:
- From point of view of driver load (E-box Remote/E-box Remote Basic), max. number of Calummas connected to one E-box Remote/E-box Remote Basic is 40 but Calummas XS have to be operated in the Pass-through mode, it means that max. 32 Calummas XS can be connected in one string.
- Max. number of Calummas XS connected to the E-box Remote/E-box Remote Basic also depends on cable length.
E-box Remote
**Cable length *** | Max. number of Calummas XS |
---|---|
50 m | 25 per output, 40 in total |
100 m | 20 per output, 40 in total |
E-box Remote Basic
**Cable length *** | Max. number of Calummas XS |
---|---|
50 m | 25 |
100 m | 20 |
Cable length is a total cable length on both LED outputs.
Example:
Total cable length=L1+L2+L3+L4+L5+L6+L7+L8+L9
Power On/Off
Note: This type of connection is available for single chip (SC) versions
only – pure white or single colour. Non dimmable.
LEDs Input voltage: 48V
Calumma XS Power On/Off connection
Colours of wires apply to the 5-cored cable UL 20969 5x 20AWG (P/N
13053481).
Connector | Vcc | D+ | D- | 0V | **** |
---|---|---|---|---|---|
Function | LEDs + | Not connected | Not connected | LEDs – | Not connected |
Colour of wire | Red | – | – | Black | – |
Installation
Mounting the fixture
-
The Calumma can be fastened in any orientation on a flat, non-flammable surface by means of mounting yoke (2).
-
The LED module (4) can be tilted +180°/-180°. Use an Allen key 2.5 for adjusting a LED module position.
Connection to power
The unit must be installed by a qualified electrician in accordance with all national and local electrical and construction codes and regulations.
Junction box installation
-
Junction box with one output
-
Junction box with four outputs
1. Unscrew the four screws (1) from the cover (2) on the junction box to get access to the DPS with terminal blocks (3) and two mounting holes (4).
2. Screw the junction box on a non-flammable flat surface.
3. Connect cables to terminal blocks.
* Two cable glands M20 x 1.5 serves for a power/data cable. One (or four) cable gland M12 x 1.5 serves for Calumma XS connection cable.
* Remove the end cap from the cable gland before passing the cable.
* We recommend to apply an adequate layer of the paste LOCTITE 5331 on the plastic holder of the cable gland before inserting it into the body of the gland.
- **Cable gland M20x1.5 and M12x1.5
**
* Wiring of connection blocks on DPS RB4232 in the junction box with one LED output.
* Wiring of connection blocks on DPS RB4233 in the junction box with four LED outputs.
- Calumma XS connection
Connector| Vcc| D+| D-| 0V|
---|---|---|---|---|---
Function| LEDs +| Data +| Data –| LEDs –| Not connected
Colour of wire| Red| Orange| White| Black| –
Colours of wires apply to the 5-cored cable UL 20969 5x 20AWG (P/N 13053481)
Connection between junction box and E-box Remote and among junction boxes
Connector| Vcc| D+| D-| 0V|
---|---|---|---|---|---
Function| LEDs +| Data +| Data –| LEDs –| Not connected
Colour of wire| Red| Orange| White| Black| –
Colours of wires apply to the 5-cored cable SJTW 5x 14AWG (P/N 1305 3336).
NOTE: Each DMX line of Calummas XS connected to the LED output of the
E-box Remote has to be terminated at the last fixture. Connect a 120 Ohm
resistor between terminals D+ and D- in the last junction box.
Example:
Example of Control panel in RDM manager
The software RDM manager is available on the ROBE website
(https://www.robe.cz/support), product RUNIT WTX.
Manufacturer PIDs
- LED calibration 4byte HEX! (RGBW/RGBA) – the item shows 4 bytes of calibration values for calibrated white colours of RGBW(RGBA) Calumma.
E.g.
CTC channel has to be set to some calibrated white colour (21 DMX-1800K, 66
DMX-2700K,
91 DMX-3200K, 141 DMX-4200K, 211 DMX-5600K, 255 DMX-6500K) otherwise the item
shows values “ff ff ff ff” (and calibration values cannot be saved to the
Calumma).
Warning!
Changing and saving values in this item will affect calibrated white colour(s)
of the Calumma . Insect friendly light – the item effects RGBA Calumma only.
If the item is on, blue colour is not used in calibrated white colours. This
modification of white lights results in a smaller attraction of white light
for insects (mosquitos, moths..). The function is also available from DMX
chart (channel Special Function, range 7-10 DMX).
- WiFi unlink – the item is inactive for Calumma XS.
- Terminator active – the item inactive for Calumma XS
Software update
-
Software update of Calumma XS modules has to be done by means of the software ROBE Uploader running on PC.
-
The ROBE Uploader is a software for automatized software update of ROBE fixtures. The ROBE Uploader switches
-
Calummas XS to the update mode automatically.
-
Please see https://www.robe.cz/robe-uploader/ for more information.
Note: CalummaXS modules in ON/OFF connection cannot be updated. -
The Calummas XS have to be operated in the Pass-Through mode only.
-
To update Calummas XS including the E-box Remote.
- Update connected LED modules by means of the file Calumma.lib in the ROBE Uploader.
- Set the E-box Remote to the Standard mode and switch it off/on. Use the file EminereEbox.lib in the ROBE Uploader for software update of the E-box Remote.
- After updating the E-box Remote, set the E-box Remote to the Pass-Through mode and switch it off/on.
-
For more information about updating please see the E-box Remote user manual and E-box Remote Base user manual.
Examples of connection for software update
-
By means of DMX connection and Robe Universal Interface.
-
By means of the Ethernet connection
Technical specifications
-
Power supply
- Input voltage : 48 V
- Power consumption:
- Calumma XS MC: 10 W
- Calumma XS SC: 10 W
-
Optic
- Light source:
- Calumma XS MC: one high power multichip LEDs
- Calumma XS SC: 4 x high power single chip LED
- Colour variants Calumma XS MC: RGBW (W – 6500 K), RGBA, PW (W – 3000 K)
- Colour variants Calumma XS SC: PW (W – 3000 K)
- Beam Angle Calumma XS MC:
- Symetrical: 9°,12°, 15°, 25°, 30°, 45°, 65°, 100°
- Bi-symetrical: 10° x 30°, 30° x 10°, 10° x 60°, 60° x 10°, 15° x 45°, 45° x 15°, 15°x90°, 90°x15°, 30°x60°, 60°x30°, 30°x90°, 90°x30°
- Beam Angle Calumma XS SC:
- Symetrical: 10°, 15°, 25°, 30°, 45°, 65°, 100°
- Bi-symetrical: 10° x 30°, 30° x 10°, 10° x 60°, 60° x 10°, 15° x 45°, 45° x 15°, 15°x90°, 90°x15°, 30°x60°, 60°x30°, 30°x90°, 90°x30°
- Projected Lumen Maintenance: L90B10 >90.000 hrs, Ta = 25°C / 77°F
-
Compatible drivers
- E-box Remote
- E-box Remote Basic
-
Mounting method
- Via yoke
- Adjustability: -180°/+180°
-
Housing
- High pressure die-cast aluminium body
- Tempered glass
-
Cooling system Convection
-
Total heat dissipation
- Calumma XS MC: 25 BTU/h (calculated)
- Calumma XS SC : 25 BTU/h (calculated)
-
Protection factor
- CE: IP 67 (IP 66 junction box)
- US: Suitable for wet location
-
Impact rating IK10
-
Operating ambient temperature range -20°C /+40°C (-4°F /+104°F)
-
Connection
Via E-box Remote/E-box Remote Basic- Calumma IN: cable UL 20969 5x 20AWG (P/N 13053481), length 1m standard
- Interconnecting cable between junction boxes: SJTW 5x 14AWG (P/N 13053336)
- Junction Box for Calumma XS, (1x Output)
- Junction Box for Calumma XS, (4x Output)
-
Connection On/Off
Calumma IN: cable UL 20969 5x 20AWG black (P/N 13053481), length 1m standard- Interconnecting cable between junction boxes: SJTW 5x 14AWG (P/N 13053336)
- Junction Box for Calumma XS, (1x Output)
- Junction Box for Calumma XS, (4x Output)
-
Weight
- Calumma XS MC : 0.59 kg (1.3 lbs)
- Calumma XS SC: 0.6 kg (1.3 lbs)
-
**Dimensions (All dimensions in mm [inch])
**
* Junction box with one output
* Junction box with four outputs
* Land Spike
- Included items
- 1 x Calumma XS MC / Calumma XS SC
- 1 x User manual
- Optional accessories
- Top Hat Calumma XS RAL9011 (P/N 10980732)
- Half Top Hat Calumma XS RAL9011 (P/N 10980736)
- Tenon Adaptor for Calumma XS
- Pole Mount Bracket for Calumma XS
- Junction Box for Calumma XS, 1x Output, Ral 9011 (P/N 10980715)
- Junction Box for Calumma XS, 4x Output, Ral 9011 (P/N 10980716)
- Land Spike for Calumma XS RAL6008 (P/N 10981031)
Cleaning and maintenance
DANGER !
Disconnect from the mains before starting any maintenance or cleaning work
- Rinse off loose dirt with low pressure water spray. Wash the housing with a soft brush or sponge and a mild, nonabrasive washing detergent. Rinse it.
- Maintenance and service operations are only to be carried out by a qualified person.
- Should you need any spare parts, please use ROBE OEM parts.
Disposing of the product
To preserve the environment please dispose or recycle this product at the end
of its life according to the local regulations and codes.
ChangeLog
This section summarizes changes in the user manual.
Version of manual | Date of issue | Description of changes |
---|---|---|
1.1 | 13/09/2022 | Junction box connection change |
1.2 | 13/10/2022 | DMX chart ver. 1.1 added |
1.3 | 14/10/2022 | Numbers of connected Calummas to E-box changed |
1.4 | 05/01/2022 | Description of the software update changed |
1.5 | 10/02/2023 | DMX chart ver. 1.2 added |
1.6 | 22/02/2023 | Cable gland installation changed |
1.7 | 10/03/2023 | Beam angle 12°added at MC version |
1.8 | 17/03/2023 | EMC notes added |
1.9 | 17/04/2023 | DMX line termination more specified |
1.10 | 03/07/2023 | On/Off operation added |
1.11 | 11/09/2023 | Total cable length specification changed |
1.12 | 11/01/2024 | On/Off connection changed, DMX connection changed |
1.13 | 23/01/2024 | Control panel of RDM manager added, DMX chart ver. 1.3 |
1.14 | 16/02/2024 | Notice about Protection class III added to Safety |
instructions
1.15| 26/04/2024| Connection in junction box changed
1.16| 14/06/2024| Land Spike added to optional accessories
DMX protocol
DMX protocol for Calumma – All sizes – MC and SC
Version: 1.3 (16 modes in total)| | |
Mode/Channels in all| Mode 1- RGBW(A)-8bit, Mode 2- RGB 8-bit,
Mode 3- full RGBW(A)|
1| 2| 3| 4| 5| 6| 7|
8-10| Mode 4- White-full control, Mode 5- Reduced RGBW(A)|
4| 3| 12| 3| 6| 8| 15| Reserved| Mode 6- Reduced RGBW(A)+white control,
Mode 7- Full control|
| | | | | | | | Mode 7-Full RGBW(A)+virt. Colour wheel|
| | | | | | | | RGBW/RGBA/RGB modes|
Mode/channels|
DMX Value
| Function|
Type of control
1| 2| 3| 4| 5| 6| 7
–| –| –| –| –| –| 1| | Special
functions|
| | | | | | | 0| No function| step
| | | | | | | | To activate following functions , stop in DMX value
for at least 3 sec.|
| | | | | | | 1-2| Save current DMX values to fixture as initial DMX
values.| step
| | | | | | | 3-4| Show saved initial DMX values| step
| | | | | | | 5-6| Run factory demo sequences at switching fixture on
(without DMX)| step
| | | | | | | 7-8| Insect friendly light On (RGBA version only)| step
| | | | | | | 9-10| Insect friendly light Off (RGBA version only)| step
| | | | | | | 11-255| Reserved|
1| 1| 1| –| 1| 1| 2| | Red|
| | | | | | | 0 – 255| Red LEDs saturation control (0-100%)|
proportional
–| –| 2| –| –| –| 3| | Red Fine|
| | | | | | | 0 – 255| Red LEDs saturation control fine| proportional
2| 2| 3| –| 2| 2| 4| | Green|
| | | | | | | 0 – 255| Green LEDs saturation control (0-100%)|
proportional
–| –| 4| –| –| –| 5| | Green Fine|
| | | | | | | 0 – 255| Green LEDs saturation control fine| proportional
3| 3| 5| –| 3| 3| 6| | Blue|
| | | | | | | 0 – 255| Blue LEDs saturation control (0-100%)|
proportional
–| –| 6| –| –| –| 7| | Blue Fine|
| | | | | | | 0 – 255| Blue LEDs saturation control fine| proportional
4| –| 7| –| 4| 4| 8| | White
(Amber)|
| | | | | | | 0 – 255| White LEDs saturation control (0-100%)|
proportional
–| –| 8| –| –| –| 9| | White (Amber)
Fine|
| | | | | | | 0 – 255| White LEDs saturation control fine| proportional
–| –| 9| 1| –| 5| 10| | Green
correction|
| | | | | | | 0| Uncorrected white| step
| | | | | | | 1-127| Minus green – uncorrected white| proportional
| | | | | | | 128| Uncorrected white (128=default)| step
| | | | | | | 129-255| Uncorrected white – Plus green| proportional
–| –| 10| 2| –| 6| 11| | Colour
temperature correction (CTC)|
| | | | | | | 0| No function| step
| | | | | | | 1 – 10| Tungsten dimming 2700 K| step
| | | | | | | 11 – 20| Tungsten dimming 3200 K| step
| | | | | | | 21-255| Colour temperature changing from 1800 K –> 6500
K| proportional
| | | | | | | | (21-1800K, 66-2700K, 91-3200K,141-4200K, 211-5600K,
255-
6500K)
|
–| –| –| –| –| –| 12| | Virtual Colour
Wheel|
| | | | | | | 0| No function| step
| | | | | | | 1-2| White 1800 K| step
---|---|---|---|---|---|---|---|---|---
| | | | | | | 3-4| White 2700 K| step
| | | | | | | 5-6| White 3200 K| step
| | | | | | | 7-8| White 4200 K| step
| | | | | | | 9-10| White 5600 K| step
| | | | | | | 11-12| White 6500 K| step
| | | | | | | 13| Blue (Blue=full, Red+Green+White/Amber=0)| step
| | | | | | | 14-23| Red=0, Green->up,Blue =full, White/Amber=0|
proportional
| | | | | | | 24| Cyan (Red=0, Green=full, Blue =full, White/Amber=0)|
step
| | | | | | | 25-34| Red=0, Green=full, Blue->down, White/Amber=0|
proportional
| | | | | | | 35| Green (Red=0, Green=full, Blue =0, White/Amber=0)|
step
| | | | | | | 36-45| Red->up, Green=full, Blue=0, White/Amber=0|
proportional
| | | | | | | 46| Yellow (Red=full, Green=full, Blue=0, White/Amber=0)|
step
| | | | | | | 47-56| Red=full, Green->down, Blue=0, White/Amber=0|
proportional
| | | | | | | 57| Red(Red=full, Green=0, Blue=0, White/Amber=0)| step
| | | | | | | 58-67| Red=full, Green=0, Blue->up, White/Amber=0|
proportional
| | | | | | | 68| Magenta (Red=full, Green=0, Blue=full,
White/Amber=0)| step
| | | | | | | 69-78| Red -> down, Green=0, Blue=full, White/Amber=0|
proportional
| | | | | | | 79| Blue (Red=0, Green=0, Blue=full, White/Amber=0)| step
| | | | | | | | Transition effects|
| | | | | | | 80-87| Rainbow effect (with fade time) from slow-> fast|
proportional
| | | | | | | 88-95| Rainbow effect (without fade time) from slow->
fast| proportional
| | | | | | | 96-103| Full dynamic white (1800K->6500K->1800K) (with
fade time)
from slow-> fast
| proportional
| | | | | | | 104-111| Full dynamic white (1800K->6500K->1800K)
(without fade time)
from slow-> fast
| proportional
| | | | | | | 112-119| Dynamic warm white (1800K-3000K-1800K) (with
fade time)
from slow-> fast
| proportional
| | | | | | | 120-127| Dynamic warm white (1800K-3000K-1800K) (without
fade time)
from slow-> fast
| proportional
| | | | | | | 128-135| Rainbow effect + full dynamic white (with fade
time) from slow-
fast
| proportional
| | | | | | | 136-143| Rainbow effect + full dynamic white (without
fade time) from
slow-> fast
| proportional
| | | | | | | 144-151| Blue/Green effect (with fade time) from slow->
fast| proportional
| | | | | | | 152-159| Blue/Green effect (without fade time) from
slow-> fast| proportional
| | | | | | | 160-167| Red/Blue effect (with fade time) from slow->
fast| proportional
| | | | | | | 168-175| Red/Blue effect (without fade time) from slow->
fast| proportional
| | | | | | | 176-183| Green/Red effect (with fade time) from slow->
fast| proportional
| | | | | | | 184-191| Green/Red effect (without fade time) from slow->
fast| proportional
| | | | | | | 192-199| Blue/4000K effect (with fade time) from slow->
fast| proportional
| | | | | | | 200-207| Blue/4000K effect (without fade time) from
slow-> fast| proportional
| | | | | | | 208-215| Green/4000K effect (with fade time) from slow->
fast| proportional
| | | | | | | 216-223| Green/4000K effect (without fade time) from
slow-> fast| proportional
| | | | | | | 224-231| Red/4000K effect (with fade time) from slow->
fast| proportional
| | | | | | | 232-239| Red/4000K effect (without fade time) from slow->
fast| proportional
| | | | | | 13| | Shutter/Strobe|
| | | | | | | 0-31| Shutter closed| step
| | | | | | | 32-63| Shutter open| step
| | | | | | | 64-95| Strobe-effect from slow to fast| proportional
| | | | | | | 96-127| Shutter open| step
---|---|---|---|---|---|---|---|---|---
| | | | | | | 128-143| Opening pulse in sequences from slow to fast|
proportional
| | | | | | | 144-159| Closing pulse in sequences from fast to slow|
proportional
| | | | | | | 160-191| Shutter open| step
| | | | | | | 192-223| Random strobe-effect from slow to fast|
proportional
| | | | | | | 224-255| Shutter open| step
–| –| 11| 3| 5| 7| 14| | Dimmer|
| | | | | | | 0 – 255| Light intensity coarse (0-100%)| proportional
–| –| 12| –| 6| 8| 15| | Dimmer
Fine|
| | | | | | | 0 – 255| Light intensity fine| proportional
| | | | | | | | |
Copyright © 2022-2024 Robe Lighting s.r.o. – All rights reserved|
All Specifications subject to change without notice|
DMX protocol for Calumma – All sizes – MC and SC
Version: 1.3 (16 modes in total)| | |
Mode/Channels in all| TW Modes: Mode 11- White selection + Dimmer,
Mode 12- WW + CW|
11| 12| 13| 14-16| PW Mode: Mode 13-
Dimmer|
3| 4| 2| Reserved| |
| | | | TW and PW modes|
Mode/channels| DMX
Value
| Function|
Type of control
11| 12| 13
1| –| –| | White colour selection|
| | | 0 – 255| White from 2700 K – 6500 K| proportional
–| 1| –| | Warm White|
| | | 0 – 255| Warm White LEDs saturation control (0-100%)| proportional
–| 2| –| | Cool White|
| | | 0 – 255| Cool White LEDs saturation control (0-100%)| proportional
2| 3| 1| | Dimmer|
| | | 0 – 255| Light intensity coarse (0 – 100%)| proportional
3| 4| 2| | Dimmer Fine|
| | | 0 – 255| Light intensity fine| proportional
| | | | |
Copyright © 2022-2024 Robe Lighting s.r.o. – All rights reserved|
All Specifications subject to change without notice|
| | | | |
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>