BEGA 51274.4 Indoor Use Ceiling Luminaire Instruction Manual

June 17, 2024
BEGA

Technical amendments reserved
Ceiling luminaire for indoor use
51 274.4

BEGA 51274.4 Indoor Use Ceiling Luminaire - Fig 1

Instructions for use

Application

Ceiling luminaire – Indoor luminaire with 2 ring-shaped light sources for unshielded and uniform light, light-diffusing silicone diffusers and metal rings.
As single luminaires or in arrangements, they are creative lighting design solutions for interior design.

Product description

Ring made of metal and luminaire housing made of synthetic material, surface colour matt brass
Round inlay made of metal, surface colour velvet white
Diffusor made of translucent ageing-resistant silicone
Mounting plate with 2 fixing holes ø 4.8 mm · 35 mm spacing
Connecting terminals 1,5▢
Earth conductor terminal
2-pole connection terminals for digital control
LED power supply unit
220-240 V 0/50-60 Hz
DC 196-250 V
DALI-controllable
Number of DALI addresses: 1
Basic insulation is provided between the mains and control cables
BEGA Thermal Control®
Temporary thermal regulation to protect temperature-sensitive components without switching off the luminaire Safety class I
– Conformity mark
Weight: 1.1 kg
This product contains light sources of energy efficiency class(es) D

Safety

The installation and operation of this luminaire are subject to national safety regulations.
Installation and commissioning may only be carried out by a qualified electrician.
The manufacturer accepts no liability for damage caused by improper use or installation.
If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Overvoltage protection

The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e. g. transients, etc. we recommend separate overvoltage protection components.
You can find them on our website at www.bega.com.

Lamp

Module connected wattage 34.8 W
Luminaire connected wattage 39 W
Rated temperature ta= 25 °C
Service life criteria 50 000 h / L70

51 274.4 K3

Module designation
LED-1409/930 + LED-1413/930
Colour temperature
Colour rendering index
Module luminous flux
Luminaire luminous flux
Luminaire luminous efficiency
| 3000 K
CRI > 90
5400 lm
3400 lm
87,2 lm / W
---|---

  • preliminary data

Installation

LED are high-quality electronic components!
Please avoid touching the light output opening of the LED directly during installation or relamping.
Remove the earth conductor connection (plug contact) between mounting plate and power supply unit.
Please ensure that sufficient installation clearance is provided for the luminaire on the ceiling.

BEGA 51274.4 Indoor Use Ceiling Luminaire - Fig 2

The axial mounting distance of the mounting plate to walls must be at least 425 mm. Pass the power connecting cable through the cable entry in the mounting plate.
Note position of application of the mounting plate “arrow down”.
Fasten the mounting plate with the supplied fastening material or other suitable fastening material to the installation surface.
Establish earth conductor connection to the earth conductor connection screw and make the electrical connection to the terminals.
Re-establish the earth conductor connection (plug contact) between mounting plate and power supply unit.
Insert the connection terminals into the luminaire housing.

IMPORTANT: Before installing the luminaire housing on the mounting plate, make sure that the external marking in the upper edge of the luminaire housing points to the recess in the fastening edge of the mounting plate.

BEGA 51274.4 Indoor Use Ceiling Luminaire - Fig 3

Position the luminaire housing in a flat inclination angle over the fastening edge of the mounting plate and swing in.
Press the luminaire housing with ring seal firmly onto the mounting plate and tighten clockwise.
The luminaire’s anti-twist device makes it possible to turn the luminaire housing between 25° and 340° in both directions on the mounting plate for alignment and fine adjustment.

Cleaning · Maintenance

Clean luminaire regularly with solvent-free cleansers from dirt.

Replacing the LED module
The designation of the LED module is noted on a label in the luminaire.
The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted. The module can be replaced by qualified persons using standard tools.
Disconnect the system from the power supply. Press the luminaire housing with ring seal firmly against the mounting plate and remove from the mounting plate by turning anti-clockwise.
Loosen the connecting wires from the terminals and place the luminaire with the top side on a soft surface.
Release the metal discs inserted on the underside of the luminaire housing from the housing groove by applying slight pressure on the edge, and remove them against the magnetic force.
To replace a LED module with diffusor, it is necessary to open the luminaire housing on the underside.

Hold the ceiling luminaire by the luminaire housing and, using a suitable tool, apply pressure to the four snap-in hooks of the luminaire housing until the housing section releases from the latch. Remove the LED module with the diffuser from the holder. Install the replacement module.
Please follow the installation instructions for the new LED module.
If necessary, repeat the same procedure with any additional LED module (housing section).
A defective luminaire cover must be replaced.
Reinsert the previously removed metal disk into the magnetic housing recess on the underside.
Install the luminaire on the ceiling again in the reverse order.

Spares

LED power supply unit
LED module 3000 K
LED module 3000 K
Round blank (inlay)| DEV-0305/700i
LED-1409/930
LED-1413/930
72 004 054 B1
---|---

BEGA Gantenbrink-Leuchten KG · Postfach 31 60 · 58689 Menden · info@bega.com · www.bega.com