BEGA 51274.4 Indoor Use Ceiling Luminaire Instruction Manual
- June 17, 2024
- BEGA
Table of Contents
Technical amendments reserved
Ceiling luminaire for indoor use
51 274.4
Instructions for use
Application
Ceiling luminaire – Indoor luminaire with 2 ring-shaped light sources for
unshielded and uniform light, light-diffusing silicone diffusers and metal
rings.
As single luminaires or in arrangements, they are creative lighting design
solutions for interior design.
Product description
Ring made of metal and luminaire housing made of synthetic material, surface
colour matt brass
Round inlay made of metal, surface colour velvet white
Diffusor made of translucent ageing-resistant silicone
Mounting plate with 2 fixing holes ø 4.8 mm · 35 mm spacing
Connecting terminals 1,5▢
Earth conductor terminal
2-pole connection terminals for digital control
LED power supply unit
220-240 V 0/50-60 Hz
DC 196-250 V
DALI-controllable
Number of DALI addresses: 1
Basic insulation is provided between the mains and control cables
BEGA Thermal Control®
Temporary thermal regulation to protect temperature-sensitive components
without switching off the luminaire Safety class I
– Conformity mark
Weight: 1.1 kg
This product contains light sources of energy efficiency class(es) D
Safety
The installation and operation of this luminaire are subject to national
safety regulations.
Installation and commissioning may only be carried out by a qualified
electrician.
The manufacturer accepts no liability for damage caused by improper use or
installation.
If subsequent modifications are made to the luminaire, the person responsible
for these modifications shall be considered the manufacturer.
Overvoltage protection
The electronic components installed in the luminaire are protected against
overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e. g. transients, etc. we
recommend separate overvoltage protection components.
You can find them on our website at www.bega.com.
Lamp
Module connected wattage | 34.8 W |
---|---|
Luminaire connected wattage | 39 W |
Rated temperature | ta= 25 °C |
Service life criteria | 50 000 h / L70 |
51 274.4 K3
Module designation
LED-1409/930 + LED-1413/930
Colour temperature
Colour rendering index
Module luminous flux
Luminaire luminous flux
Luminaire luminous efficiency | 3000 K
CRI > 90
5400 lm
3400 lm
87,2 lm / W
---|---
- preliminary data
Installation
LED are high-quality electronic components!
Please avoid touching the light output opening of the LED directly during
installation or relamping.
Remove the earth conductor connection (plug contact) between mounting plate
and power supply unit.
Please ensure that sufficient installation clearance is provided for the
luminaire on the ceiling.
The axial mounting distance of the mounting plate to walls must be at least
425 mm. Pass the power connecting cable through the cable entry in the
mounting plate.
Note position of application of the mounting plate “arrow down”.
Fasten the mounting plate with the supplied fastening material or other
suitable fastening material to the installation surface.
Establish earth conductor connection to the earth conductor connection screw
and make the electrical connection to the terminals.
Re-establish the earth conductor connection (plug contact) between mounting
plate and power supply unit.
Insert the connection terminals into the luminaire housing.
IMPORTANT: Before installing the luminaire housing on the mounting plate, make sure that the external marking in the upper edge of the luminaire housing points to the recess in the fastening edge of the mounting plate.
Position the luminaire housing in a flat inclination angle over the fastening
edge of the mounting plate and swing in.
Press the luminaire housing with ring seal firmly onto the mounting plate and
tighten clockwise.
The luminaire’s anti-twist device makes it possible to turn the luminaire
housing between 25° and 340° in both directions on the mounting plate for
alignment and fine adjustment.
Cleaning · Maintenance
Clean luminaire regularly with solvent-free cleansers from dirt.
Replacing the LED module
The designation of the LED module is noted on a label in the luminaire.
The light colour and light output of BEGA replacement modules correspond to
those of the modules originally fitted. The module can be replaced by
qualified persons using standard tools.
Disconnect the system from the power supply. Press the luminaire housing with
ring seal firmly against the mounting plate and remove from the mounting plate
by turning anti-clockwise.
Loosen the connecting wires from the terminals and place the luminaire with
the top side on a soft surface.
Release the metal discs inserted on the underside of the luminaire housing
from the housing groove by applying slight pressure on the edge, and remove
them against the magnetic force.
To replace a LED module with diffusor, it is necessary to open the luminaire
housing on the underside.
Hold the ceiling luminaire by the luminaire housing and, using a
suitable tool, apply pressure to the four snap-in hooks of the luminaire
housing until the housing section releases from the latch. Remove the LED
module with the diffuser from the holder. Install the replacement module.
Please follow the installation instructions for the new LED module.
If necessary, repeat the same procedure with any additional LED module
(housing section).
A defective luminaire cover must be replaced.
Reinsert the previously removed metal disk into the magnetic housing recess on
the underside.
Install the luminaire on the ceiling again in the reverse order.
Spares
LED power supply unit
LED module 3000 K
LED module 3000 K
Round blank (inlay)| DEV-0305/700i
LED-1409/930
LED-1413/930
72 004 054 B1
---|---
BEGA Gantenbrink-Leuchten KG · Postfach 31 60 · 58689 Menden · info@bega.com · www.bega.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>