PETERMANN PM-5070 Turning Disc Soft Instruction Manual
- June 17, 2024
- PETERMANN
Table of Contents
- PETERMANN PM-5070 Turning Disc Soft
- Product Information
- Product Usage Instructions
- General Information
- Safety information
- Using the product
- Product marking / CE
- Cleaning, care and disinfection
- Technical Data
- Warranty
- Disposal information
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
PETERMANN PM-5070 Turning Disc Soft
Product Information
Specifications
- Article Number: PM-5070
- Material: Cotton/natural, latex-free
- Color : Cream
- Weight : 260g
- Load Capacity: 200 kg
Product Usage Instructions
General Information
Thank you for choosing the Soft-Drehscheibe Turning Disc. Please read the
user manual carefully before using the product for the first time.
Safety Information
Ensure to follow all safety symbols and conduct a function check before
each use.
Product Application
- Indication and Further Use: The Soft-Drehscheibe Turning Disc is designed for transferring patients from one surface to another with reduced physical strain.
- Contraindications: Check for any specific contraindications before using the product.
- Application Risks: Be aware of potential risks associated with the product’s usage and take necessary precautions.
- Areas of Application: Use the disc in various healthcare settings for patient transfers.
- Application Illustration: Refer to the user manual for a visual guide on how to use the product correctly.
- Approved Accessories: Combine the Soft-Drehscheibe Turning Disc with PM-7010/7011 Antirutschmatte for enhanced functionality.
Cleaning, Care, and Disinfection
Follow the recommended cleaning and disinfection procedures to maintain
hygiene standards. Use suitable disinfectants and avoid damaging the product
during cleaning.
Frequently Asked Questions (FAQ)
-
Q: What is the maximum weight capacity of the Soft-Drehscheibe Turning Disc?
A: The disc can support a maximum weight of 200 kg. Ensure not to exceed this limit for safe usage. -
Q: Can I combine the Soft-Drehscheibe Turning Disc with other products?
A: Yes, you can use the disc in combination with PM-7010/7011 Antirutschmatte for added functionality.
General Information
- Thank you for choosing a Petermann product.
- Please read the user manual carefully before using the product for the first time!
- The current understanding in modern occupational health and safety is that people in nursing professions experience significant work-related physical strain. Back injuries are common. There are many situations in which a patient has to be transferred from a bed, a wheeled stretcher, ambulance stretcher, an X-Ray table or a wheelchair to a different stretcher or seat. The strain on the user and the patient/caregiver can be reduced significantly through the use of sliding mats.
- The use of transfer aids should be conditional upon the user having learned to use the equipment properly. The user has to decide for themselves what equipment is suitable to the patient’s situation and the intended sequence of movements.
- The Petermann Soft Turning Disc is part of a product line that is used specifically to support turning movements of patients with lower extremity limitations and largely intact trunk stability.
- The product may only be used for the specified purpose and under the specified conditions.
- The information in this user manual is for the patient who is being transferred and moved, as well as the user performing the transfer/position change.
- Contact us if you require additional information or assistance using the Petermann product.
Product versions
- Item no.: PM-5070 Soft Turning Disc
Accessories
- No accessories are available for this device.
Scope of delivery
- Soft Turning Disc
- User manual
Storage, transport
- Store/transport at -5 C – 40 C
- Other: protect from sunlight
Service life / lifecycle
- If the product is used in accordance with the safety instructions, then the expected product service life is five years.
- However, the effective service life may vary depending on the frequency and intensity of use and the number of washing and disinfection cycles.
- Perform regular function checks on the product and be sure to observe the safety information (see item 2)
Safety information
WARNING indicates a potential danger which could lead to personal injury or material damage.
- It is the responsibility of the organisation / the user to determine, on the basis of the circumstances (weight / health condition of the patient) and the capabilities of the user, whether several users may be required for the transfer and/or whether additional safety measures are required.
- Defective products may no longer be used.
- Weight limits must be observed (200 kg).
- The Soft Turning Disc may not be used while driving in vehicles.
- Transfer products are subject to a natural ageing process. Inspect the equipment regularly to ensure proper functionality.
- In case of direct skin contact, observation of changes in skin appearance is indicated.
- The use of non-standard cleaning agents or bleaching agents, alcohols, fabric softeners or other chemical laundry additives may lead to permanent deterioration of the sliding mat properties.
Symbols used
Function check
Transfer products are also subject to a natural ageing process. Inspect the
equipment regularly and carefully, in particular before each use.
Visual inspection
Ensure that material, seams, handle loops and buckles are undamaged and in
functional order.
Sliding properties
- Place the product on a firm surface
- Pull your hands over the product with pressure
- Good glide – easy gliding
- Low glide: no gliding/moving possible
Defective products may no longer be used!
Using the product
Indication and further use
Due to the wide range of possible applications, the indications cannot be tied
to a specific clinical picture, since Sliding Mats are suitable for all
applications involving people who require assistance. Thanks to the reduced
friction, the capabilities of the patient can be put to use when Sliding Mats
are used. The effort required on the part of the user is reduced. The product
can be used to support the following diagnoses:
Patients with lower extremity limitations and largely intact trunk
stability.
This product may be reused. Before reusing the product, be sure to perform a
thorough function check (see item 2.2) as well as cleaning or disinfection of
the product. (see item 5)
Contraindications
Contraindications cannot be tied to a specific clinical picture. Observe the
safety information under item 2. In the following patient pictures, the use of
the products may have to be avoided:
Insufficient trunk stability
Application risks
- The soft turntable has no restraining function, so if the torso is not stable, there is → Risk of falling
- Do not use while driving in a vehicle, as there is no restraint function. → Risk of falling
Areas of application
The product can be used in home care and other health care facilities.
Application illustration
Application
The Soft Turning Disc allows the patient to change their sitting position
independently by aligning the body.
- Weight transfer
- Residual muscle function
- Active and passive corrections of the sitting position are possible
The Soft Turning Disc can be used for transfers in/out a car seat.
Warning : Do not leave the product while driving because of the sliding
risks in case of an unexpected event or movement.
Visit our website at www.pm-med.de or watch our
comprehensive product videos on our YouTube channel.
Approved accessories, in combination with other products
Soft Turning Discs are used in combination with the following products:
PM-7010/7011 Non-Slip Mats
Petermann transfer aids are part of a comprehensive aid product range, which
are effective and back-friendly for the user and comfortable and supportive
for the patients. Additional Petermann products may be used according to the
situation and clinical picture. Ask our experts. We are happy to help you!
Product marking / CE
- The Petermann Soft Turning Disc is a Class I Medical Device and meets the EU-Regulation 2017/745 of the European Parliament and Council dated 05.04.2017 for medical devices, also called MDR.
- Petermann GmbH is certified by DIN EN ISO 13485 by TÜV Süd, Medical Devices – Quality management systems applicable to the design and development, production and distribution of aids for people of limited mobility
Cleaning, care and disinfection
__60° washing machine| Recommended disinfectants for wipe disinfection:
– Trionic® (DGHM/VAH approval, further information on request)
– Mikrobac® Tissues*
– Mikrobac® forte*
– Bacillol® 30 Foam
– Bacillol® 30 Tissues
– Bacillol® 30 Sensitive Tissues
– Mikrobac® Virucidal Tissues*
---|---
__Mild detergent
Do not use cleaning agents with bleaching ingredients or chemical laundry
additives!
Otherwise, the product properties may deteriorate permanently.
__Wash with similar colors only| * wipe with a cloth soaked in water after
disinfection to avoid residues or layer build-up. Please always follow the
manufacturer’s manuals for use when wiping disinfection.
Recommended detergent for industrial washing machines:
Maximo Liquid as a single detergent
Low dryer temperatures (45° – 50° C)
Technical Data
Item no. | Material | Color | Load-bearing capacity |
---|---|---|---|
PM-5070 | Cotton/natural thicking, latex-free | cream | 200 kg |
Item no. | Description | Dimensions in mm | Weight |
--- | --- | --- | --- |
PM-5070 | Soft Turning Disc | Ø 460 | 260 g |
The manufacturing of our products is subject to the highest quality standards. Due to usual manufacturing variations published dimensions and further information concerning the condition of the product are defined as target production specifications. Deviations that might occur are monitored by professional quality management procedures and do not represent a reduction in the performance of the respective product.
Warranty
- The company Petermann warrants that the product is free from defects in material and workmanship.
- The warranty period is 3 years. It does not cover defects attributable to abrasion, normal wear, improper use or improper cleaning.
- The company Petermann is not liable for accidental or consequential injury or material damage.
Disposal information
There are no specific disposal regulations for open Soft Turning Discs, they can be disposed of in accordance with applicable national and local regulations.
Petermann GmbH Waldweg 3 D-91601 Dombühl
Phone : +49 (0) 9868-9339-0
Email : petermann@pm-med.de
References
- med.de - Ihr Medizinportal | Chirurgie | Krankheiten | Gesundheit | Arztsuche
- Innovative Hilfsmittel - Manuellen Transferhilfen - Petermann DE