Ademco Vista-20 Wiring Trikdis GT+ Cellular Communicator Owner’s Manual
- June 17, 2024
- TRIKDIS
Table of Contents
Ademco Vista-20
Wiring Trikdis GT+ Cellular Communicator and
Programming the Panel
Ademco Vista-20 Wiring Trikdis GT+ Cellular Communicator
CAUTION
- The communicator should be installed and maintained by qualified personnel.
- Prior to installation, it is advised to read full device installation manual carefully in order to avoid mistakes that can lead to malfunction or even damage the equipment.
- Disconnect the power supply before making any electrical connections.
- Changes, modifications or repairs not authorized by the manufacturer shall void your rights under the warranty.
Schematics forwiring the communicator to the security control panel
Following the schematics provided below, wire the communicator to the control
panel.Programming the Honeywell Ademco
Vista-20Alarm Panel via Keypad
Using the control panel’s keypad enter these sections and set them as
described:
Enable Contact ID reporting
Keypad Entry | Action Description |
---|---|
4112800 | Enter programming mode |
591 | Enable “Exit Error Report Code” |
601 | Enable “Trouble Report Code” |
611 | Enable “Bypass Reporting Code” |
621 | Enable “AC Loss Report Code” |
631 | Enable “Low Battery Report Code” |
641 | Enable “Test Report Code” |
651 | Enable “Open Report Code” |
661 | Enable “Arm Away/Stay Report Code” |
671 | Enable “RF Transmitter Low Battery Report Code” |
681 | Enable “Cancel Report Code” |
691 | Enable “Recent Closing Report Code” |
701 | Enable “Alarm Restore Report Code” |
711 | Enable “Trouble Restore Report Code” |
721 | Enable “Bypass Restore Report Code” |
731 | Enable “AC Restore Report Code” |
741 | Enable “Low Battery Restore Report Code” |
751 | Enable “RF Transmitter Low Restore Code” |
761 | Enable “Test Restore Report Code” |
291 | Enable “Enable IP/GSM” |
1891 | Enable “AUI Device Enable” |
*99 | Exit programming mode. |
Setting up the GT+ communicator with the app
Download and launch the Protegus application or use the browser version:
web.protegus.app.
The installer must connect to Protegus with an installer account.Setting up the GT+ communicator with the app
Enter the e-mail of the user to whom the installer will
transfer the system. Press “Transfer”| The system will appear in
Protegus on the user’s phone
After completing the setup and installation perform a system check:
-
Create an event:
– by arming/disarming the system with the control panel’s keypad;
– by triggering a zone alarm when the security system is armed. -
Make sure that the event arrives to the CMS (Central Monitoring Station) and the Protegus app.
Read User Manual Online (PDF format)