TRIKDIS NX-8V2 GT+ Cellular Communicator Owner’s Manual
- June 17, 2024
- TRIKDIS
Table of Contents
NX-8V2
Wiring Trikdis GT+ Cellular Communicator and
Programming the Panel
CAUTION
- The communicator should be installed and maintained by qualified personnel.
- Prior to installation, it is advised to read full device installation manual carefully in order to avoid mistakes that can lead to malfunction or even damage the equipment.
- Disconnect the power supply before making any electrical connections.
- Changes, modifications or repairs not authorized by the manufacturer shall void your rights under the warranty.
Schematics forwiring the communicator to the security control panel
Following the schematics provided below, wire the communicator to the control panel.
Programming the Interlogix NX-8V2 Alarm Panel via the LCD Keypad
Using the control panel’s keypad enter these sections and set them as
described:
Enable Contact ID reporting
LCD keypad | Keypad Entry | Action Description |
---|---|---|
System ready | *89713 | Enter programming mode |
Enter device address | 0# | To go to main panel programming menu |
Enter location | 4# | To go to “Phone1 events reported” toggle menu. |
Loc#4 Seg#1 | 12345678* | All toggle options should be enabled. * to save and go |
to next menu.
Loc#4 Seg#2| 12345678| All toggle options should be enabled. to save and go
back.
Enter location| 23#| To go to “Partition features” menu.
Loc#23 Seg#1| | Press twice to go to section 3 toggle options menu.
Loc#23 Seg#3| 12345678#| Segment 3. All toggle options should be enabled,
press * to save and then # to save and # to go back to the main menu.
Enter location| 37#| To go to “Siren and system supervision” menu.
Loc#37 Seg#1| *| Press twice to go to segment 3 toggle options menu.
Loc#37 Seg#3| 12345678| Segment 3. All toggle options should be enabled,
press to save.
Loc#37 Seg#4| 12345678#| Segment 4. All toggle options should be enabled,
press to save and then # to save and # to go back to the main menu.
Enter location| 90#| To go to “Partition 2 features” menu.
Loc#90 Seg#1| | Press twice to go to section 3 toggle options menu.
Loc#90 Seg#3| 12345678#| Segment 3. All toggle options should be enabled,
press * to save and then # to save and # to go back to the main menu.
Enter location| 93#| To go to “Partition 3 features” menu.
Loc#93 Seg#1| *| Press twice to go to section 3 toggle options menu.
Loc#93 Seg#3| 12345678#| Segment 3. All toggle options should be enabled,
press to save and then # to save and # to go back to the main menu.
Programming the Interlogix NX-8V2 Alarm Panel via the LCD Keypad
Using the control panel’s keypad enter these sections and set them as
described:
Enable Contact ID reporting
LCD keypad | Keypad Entry | Action Description |
---|---|---|
Enter location | 96# | To go to “Partition 4 features” menu. |
Loc#96 Seg#1 | ** | Press * twice to go to section 3 toggle options menu. |
Loc#96 Seg#3 | 12345678*# | Segment 3. All toggle options should be enabled, |
press * to save and then # to save and # to go back to the main menu.
Enter location| 99#| To go to “Partition 5 features” menu.
Loc#99 Seg#1| | Press twice to go to section 3 toggle options menu.
Loc#99 Seg#3| 12345678#| Segment 3. All toggle options should be enabled,
press * to save and then # to save and # to go back to the main menu.
Enter location| 102#| To go to “Partition 6 features” menu.
Loc#102 Seg#1| *| Press twice to go to section 3 toggle options menu.
Loc#102 Seg#3| 12345678#| Segment 3. All toggle options should be enabled,
press to save and then # to save and # to go back to the main menu.
Enter location| 105#| To go to “Partition 7 features” menu.
Loc#105 Seg#1| | Press twice to go to section 3 toggle options menu.
Loc#105 Seg#3| 12345678#| Segment 3. All toggle options should be enabled,
press * to save and then # to save and # to go back to the main menu.
Enter location| 108#| To go to “Partition 8 features” menu.
Loc#108 Seg#1| *| Press twice to go to section 3 toggle options menu.
Loc#108 Seg#3| 12345678#| Segment 3. All toggle options should be enabled,
press to save and then # to save and # to go back to the main menu.
Enter location| EXIT EXIT| Press “EXIT” twice to exit programming mode.
LED keypad| Keypad Entry| Action Description
---|---|---
LEDs of Ready, Power steady ON| 89713| Enter programming mode
Service LED blinks| 0#| To go to main panel programming menu
Service LED blinks, Armed LED steady ON| 4#| To go to “Phone1 events reported”
toggle menu.
All zone LEDs are ON| 12345678| All toggle options should be enabled. * to
save and go to next
menu.
All zone LEDs are ON| 12345678| All toggle options should be enabled. to
save and go back.
Service LED blinks, Armed LED steady ON| 23#| To go to “Partition feature and
reporting selection” menu.
Service LED blinks, Ready LED steady ON| | Press twice to go to segment 3
toggle options menu.
Service LED blinks, Ready LED steady ON| 12345678#| Segment 3. All toggle
options should be enabled, press * to save and then # to save and # to go back
to the main menu.
Service LED blinks, Armed LED steady ON| 37#| To go to “Siren and system
supervision” menu.
Service LED blinks, Ready LED steady ON| *| Press twice to go to segment 3
toggle options menu.
Service LED blinks, Ready LED steady ON| 12345678| Segment 3. All toggle
options should be enabled, press to save.
Service LED blinks, Ready LED steady ON| 12345678#| Segment 4. All toggle
options should be enabled, press to save and then # to save and # to go back
to the main menu.
Service LED blinks, Armed LED steady ON| 90#| To go to “Partition 2 feature
and reporting selection” menu.
Service LED blinks, Ready LED steady ON| | Press twice to go to segment 3
toggle options menu.
Service LED blinks, Ready LED steady ON| 12345678#| Segment 3. All toggle
options should be enabled, press * to save and then # to save and # to go back
to the main menu.
Service LED blinks, Armed LED steady ON| 93#| To go to “Partition 3 feature
and reporting selection” menu.
Service LED blinks, Ready LED steady ON| | Press twice to go to segment 3
toggle options menu.
Service LED blinks, Ready LED steady ON| 12345678#| Segment 3. All toggle
options should be enabled, press * to save and then # to save and # to go back
to the main menu.
LED keypad| Keypad Entry| Action Description
---|---|---
Service LED blinks, Armed LED steady ON| 96#| To go to “Partition 4 feature
and reporting selection” menu.
Service LED blinks, Ready LED steady ON| *| Press twice to go to segment 3
toggle options menu.
Service LED blinks, Ready LED steady ON| 12345678#| Segment 3. All toggle
options should be enabled, press to save and then # to save and # to go back
to the main menu.
Service LED blinks, Armed LED steady ON| 99#| To go to “Partition 5 feature
and reporting selection” menu.
Service LED blinks, Ready LED steady ON| | Press twice to go to segment 3
toggle options menu.
Service LED blinks, Ready LED steady ON| 12345678#| Segment 3. All toggle
options should be enabled, press * to save and then # to save and # to go back
to the main menu.
Service LED blinks, Armed LED steady ON| 102#| To go to “Partition 6 feature
and reporting selection” menu.
Service LED blinks, Ready LED steady ON| | Press twice to go to segment 3
toggle options menu.
Service LED blinks, Ready LED steady ON| 12345678#| Segment 3. All toggle
options should be enabled, press * to save and then # to save and # to go back
to the main menu.
Service LED blinks, Armed LED steady ON| 105#| To go to “Partition 7 feature
and reporting selection” menu.
Service LED blinks, Ready LED steady ON| *| Press twice to go to segment 3
toggle options menu.
Service LED blinks, Ready LED steady ON| 12345678#| Segment 3. All toggle
options should be enabled, press to save and then # to save and # to go back
to the main menu.
Service LED blinks, Armed LED steady ON| 108#| To go to “Partition 8 feature
and reporting selection” menu.
Service LED blinks, Ready LED steady ON| | Press twice to go to segment 3
toggle options menu.
Service LED blinks, Ready LED steady ON| 12345678#| Segment 3. All toggle
options should be enabled, press * to save and then # to save and # to go back
to the main menu.
Service LED blinks, Armed LED steady ON| EXIT EXIT| Press “EXIT” twice to exit
programming mode.
LED indication of communicator operation
Indicator | Light status | Description |
---|
NETWORK
| Off| No connection to cellular network
Yellow blinking| Connecting to cellular network
Green solid with yellow blinking| Communicator is connected to cellular
network. Yellow blinks count indicates signal strength, 10 blinks max.
Sufficient cellular signal strength for 4G network – level 3 (three yellow
flashes).
DATA
| Off| No unsent events
Green solid| Unsent events are stored in buffer
Green blinking| (Configuration mode) Data is being transferred to/from
communicator
POWER
| Off| Power supply is off or disconnected
Green solid| Power supply is on with sufficient voltage
Yellow solid| Power supply voltage is insufficient (≤11.5V)
Green solid and yellow blinking| Configuration mode) Communicator is
ready for configuration
Yellow solid| (Configuration mode) No connection with computer
TROUBLE
| Off| No operation problems
1 red blink| SIM card not found
2 red blinks| SIM card PIN code problem (incorrect PIN code)
3 red blinks| Programming problem (No APN)
4 red blinks| Registration to GSM network problem
5 red blinks| Registration to GPRS/UMTS network problem
6 red blinks| No connection with the receiver
7 red blinks| Lost connection with control panel
8 red blinks| The entered ICCID number does not match the ICCID number of the
SIM card
Red blinking| (Configuration mode) Memory fault
Red solid| (Configuration mode) Firmware is corrupted
BAND
| 1 green blink| None
2 green blinks| GSM
3 green blinks| GPRS
4 green blinks| EDGE
5 green blinks| HSDPA, HSUPA, HSPA+, WCDMA
6 green blinks| LTE TDD, LTE FDD
Setting up the GT+ communicator with the app
Download and launch the Protegus application or use the browser version:
web.protegus.app.
The installer must connect to Protegus with an installer account.
After completing the setup and installation perform a system check:
-
Create an event:
– by arming/disarming the system with the control panel’s keypad;
– by triggering a zone alarm when the security system is armed. -
Make sure that the event arrives to the CMS (Central Monitoring Station) and the Protegus app.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>