BEHA GEN 2 PV Smart Heaters User Guide
- June 17, 2024
- BEHA
Table of Contents
BEHA GEN 2 PV Smart Heaters
Specifications
- Model: BEHA SMARTHEATERS GEN 2
- Types: PV, LV, PGV, LGV, HR, LR
- Languages Supported:
- NO, NL, DK, TR, SE, HR, FI, SI, UK, HU, DE
Technical Information:
Factory preset temperature is 22 degrees. Thermostat can be adjusted down to 5
degrees.
Barnesikringslok: Remove child safety lock by following the instructions.
Safety Information
The heater should only be used in an upright position.
Do not attempt to repair, disassemble, or modify the heater.
Do not use the heater if it has visible damage or has been dropped.
Installation
To remove the wall bracket, press lip 1 and gently press down on lip 2.
Carefully pull out the wall bracket.
Usage and Maintenance
For more information on the app, visit beha.no.
Do not immerse the heater in water for cleaning.
Technical information
- The heater can be operated manually without using the app. The ON/OFF switch and thermostat wheel are located in the lower right corner of the heater, under the safety lid.
- Factory set temperature is 22 °C. The thermostat can be set at min. 5 °C (Frost guard).
- When the thermostat is operating (power on) a small red dot will show on the floor.
- Beha heaters PV and LV are IP24 tested and approved for installation in bathrooms and utility rooms. They can be installed according to current regulations.
By power outage
Without app: The heater returns to last set temperature.
Open window detection
When opening a window and the temperature drops more than 5°C within 40 sec,
the open window dete-ction is activated. The heater changes between chosen
temperature for 10 seconds, and 5 degrees for 30 seconds. The function is
active for max. 15 minutes. The heater returns to the last set program /
temperature.
Protection and safety lid
- Take off the lid by pulling it lightly down.
- To put the lid back on the mark shall point towards the front of the heater.
Safety information
When using any electrical appliance, basic precautions should always be
followed to reduce the risk of fire and injuries.
Please read the entire user manual before using heater.
- Before use, remove all packaging.
- Turn the switch to OFF. Remove the plug from the wall socket when the heater is not in use and when cleaning.
CAUTION! Parts of this product will become hot and may cause burns. Pay
especially attention where children and vulnerable people are present.
Children aged from 3 years and less than 8 years shall only switch on/off the
appliance provided that it has been placed or installed in its intended normal
operating position and they have been given supervision or instruction
concerning use of the appliance in a safe way and understand the hazards
involved. Children aged from 3 years and less than 8 years shall not plug in,
regulate, and clean the appliance or perform user maintenance.
Warning
In order to avoid overheating, do not cover the heater.
- This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory, or mental capabilities or lack of experience an knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
- Children of less than 3 years should be kept away unless continuously supervised.
- Furthermore, do not use the heater in areas where gasoline, paint, or flammable liquids are used or stored.
- Warning: Do not use this heater in small rooms when they are occupied by persons not capable of leaving the room on their own, unless constant supervision is provided.
- The wall socket in which the heater is connected should be visible and accessible.
- The heater must not be located immediately below a wall socket. Do not operate any heater with a damaged cord or plug. The cable must not come into contact with hot surfaces of the heater during operation.
- Do not cover the cord with carpets. Do not step on the cable. Ensure that no foreign objects are placed in the heater’s air outlets as it can cause electrical failure or fire.
- When cleaning or relocating or when the heater is not in use, the heater should be switched off and the cord unplugged. In that order. Do not remove the plug from the socket by pulling the cord. Remove the cord
- from the socket by gripping the plug and gently pull it out of the wall socket.
- Do not touch the heater with wet hands.
- The heater must be in an upright position.
- The heater should not be repaired, dismantled or modified by unauthorized personnel.
- Do not use this heater in the immediate surroundings of a bath, a shower, or a swimming pool.
- Do not use this heater if it has been dropped or if there are visible signs of damage to the heater.
- Warning: The heater should be located away from furniture, curtains or other flammable objects.
When used as a freestanding heater
When using your Beha heater as a free-standing floor heater (with PF 240), please note that the protection class changes to IP20. The heater can thus not be used in bathrooms or other damp areas where protection class IP24 is required. The heater must be placed on a level floor, and it should not be used on soft surfaces as it may tip over. The heater must not be placed near combustible materials. Switch off the heater when you are not present, especially if there are children or animals in the room.
Installation
Electrical connection and use
Before connecting, please ensure that the voltage is 220-240V ~ 50Hz. The
heater should be connected to a socket in the room it is intended to be used.
Do not connect the heater to sockets in adjacent rooms using an extension
cable.
Removing wall bracket
Remove wall bracket from heater by pressing lip 1 and push lightly down-wards
on lip 2. Pull the bracket out gently.
Fixing the wall bracket
Insert a screw in the lower keyhole approx. 13 cm above the fl oor. Level the
bracket and insert the other 3 screws. When the heater is installed, the
distance below should be approx. 10 cm.
Mounting the
heater on the wall bracket
On the bottom of the back plate there are two small triangular tracks. Place
the heater onto the tracks and push the heater towards the lips on top of the
bracket in an upright position.
Heater sizes
Using the heater
The heater may also be used without mobile app control.
Switch on the heater. The heater is factory set at 22°C. Scrolling the
thermostat wheel changes the tempera-ture setting. When the selected
temperature is shown for the fi rst time it will be displayed on the fl oor
for 10 minutes. When adjusting the temperature later it will be displayed for
10 seconds.
After a power outage or the power is switched OFF and then ON again, the
Bluetooth® symbol will be displayed on the fl oor together with the
temperature for 10 minutes. After a power outage the heater will restart at
the last set temperature.
Using the heater with mobile app control
The Beha smartheater app is working from iOS 13 and Android 8.
For more information regarding use of the app, visit beha.no
Care and maintenance
Easy cleaning
The heater tilts forward on the fi xing bracket for the ease of cleaning
behind it.
- Remove power connection and make sure the heater is cooled down before cleaning.
- Clean the outside with a damp cloth.
- Never use abrasive cleaners or submerse the heater in water or other liquids.
Additional accessories
Beha PF 240 (feet)
Suitable for PV, LV, PB and LB heaters. Please note that when the heater is
installed with PF 240,
it becomes freestanding and changes to IP 20. This is according to current
regulations. When using PF 240, the same safety precautions as described in
this manual apply. How to install PF 240 is described in the manual that
follows the accessory.
Beha GB 200 (steel bracket)
Suitable for LV, LB and LGV heaters. Steel bracket can be used for mounting
the heater on the fl oor instead of the wall, close to the wall.
Beha KB 200
Junction Box for fi xed electrical installation. Mounted on the wall bracket.
Energy efficiency
This product complies with the EU regulations of the Ecodesign Directive (2009/125/EC) for energy-related products.
Model identifier | P nom kW | P min kW | P max,c kW |
---|---|---|---|
P(G)V 4 GEN 2 | 0,4 | 0,4 | 0,4 |
P(G)V 6 GEN 2 | 0,6 | 0,6 | 0,6 |
P(G)V 8 GEN 2 | 0,8 | 0,8 | 0,8 |
P(G)V 10 GEN 2 | 1 | 1 | 1 |
P(G)V 12 GEN 2 | 1,25 | 1,25 | 1,25 |
PV 15 GEN 2 | 1,5 | 1,5 | 1,5 |
PV 20 GEN 2 | 2 | 2 | 2 |
LV 5 GEN 2 | 0,5 | 0,5 | 0,5 |
L(G)V 7 GEN 2 | 0,75 | 0,75 | 0,75 |
L(G)V 10 GEN 2 | 1 | 1 | 1 |
LV 12 GEN 2 | 1,25 | 1,25 | 1,25 |
- Pnom kW: Nominal heat output
- Pmin kW: Minimum heat output (indicative)
- Pmax,c kW: Maximum continuous heat output
Auxiliary electri- city consumption | eloff kW | elsm kW | elidle kW | elnsb kW |
---|---|---|---|---|
P(G)V 4 GEN 2 | 0 | N/A | 0,0006 | 0,0006 |
P(G)V 6 GEN 2 | 0 | N/A | 0,0006 | 0,0006 |
P(G)V 8 GEN 2 | 0 | N/A | 0,0006 | 0,0006 |
P(G)V 10 GEN 2 | 0 | N/A | 0,0006 | 0,0006 |
P(G)V 12 GEN 2 | 0 | N/A | 0,0006 | 0,0006 |
PV 15 GEN 2 | 0 | N/A | 0,0006 | 0,0006 |
PV 20 GEN 2 | 0 | N/A | 0,0006 | 0,0006 |
LV 5 GEN 2 | 0 | N/A | 0,0006 | 0,0006 |
L(G)V 7 GEN 2 | 0 | N/A | 0,0006 | 0,0006 |
L(G)V 10 GEN 2 | 0 | N/A | 0,0006 | 0,0006 |
LV 12 GEN 2 | 0 | N/A | 0,0006 | 0,0006 |
eloff: In off mode elsm: In standby mode elidle: In idle mode
elnsb: In network standby
Technical parameter
F2 and F3 are correction factors that represent a positive contribution to the
seasonal energy efficiency for space heating. Seasonal space heating energy
efficiency for electric wall-mounted heaters, with a nominal heating output
above 250W, shall not be less than 38%.
Type of heat output/room temperature control (select one) Correction factor F2
Single stage heat output and no room temperature control| |
Two or more manual stages, no room temperature control| |
With mechanic thermostat room temperature control| |
With electronic room tempera- ture control| |
Electronic room temperature control plus day timer| |
Electronic room temperature control plus week timer| yes| 7
Other control options (multiple selections possible) Correction factor F3
Room temperature control, with presence detection| |
Room temperature control, with open window detection| yes| 1
With distance control option| yes| 1
With adaptive start control| |
With working time limitation| |
With black bulb sensor| |
Energy efficiency for Beha P(X)V and L(X)V Gen 2 heaters: 39%
Waste management
Directive 2012/19/EU regarding the handling of electrical and electronic waste
(Waste Electrical and Electronic Equipment-WEEE). Make sure that this product
is disposed in the correct manner, so that it does not constitute a health or
environmental risk.
The symbol on the product or on the documents accompanying the product,
indicates that this product may not be treated as household waste. Hand it
over to an authorized reception for recycling of electrical and electronic
equipment. Disposal must take place in accordance with the local waste
disposal regulations.
For further information, treatment, recovery, and recycling of this product, contact your local council, waste disposal service or the shop where you purchased it.
Recycling of packaging
Component | Material | Recycling |
---|---|---|
Packaging | PAP 20 | Carboard and paper |
Screw bag | PE | Plastic |
BEHA ELEKTRO AS Evjeløkka 3
N-1661 Rolvsøy
beha.no
a part of Beha Group AS
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>