Beha-Amprobe AM-520-EUR Digital Multimeter User Manual
- June 13, 2024
- BEHA AMPROBE
Table of Contents
AM-520-EUR
AM-530-EUR
Digital Multimeter
User Manual
AM-520-EUR Digital Multimeter
Limited Warranty and Limitation of Liability
Your Beha-Amprobe product will be free from defects in material and
workmanship for three years from the date of purchase unless local laws
require otherwise. This warranty does not cover fuses, disposable batteries or
damage from accident, neglect, misuse, alteration, contamination, or abnormal
conditions of operation or handling. Resellers are not authorized to extend
any other warranty on the behalf of Beha-Amprobe. To obtain service during the
warranty period, return the product with proof of purchase to an authorized
Beha-Amprobe Service Center or to an Beha-Amprobe dealer or distributor. See
Repair Section for details. THIS WARRANTY IS YOUR ONLY REMEDY. ALL OTHER
WARRANTIES – WHETHER EXPRESS, IMPLIED OR STATUTORY – INCLUDING IMPLIED
WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE OR MERCHANTABILITY, ARE HEREBY
DISCLAIMED. MANUFACTURER SHALL NOT BE LIABLE FOR ANY SPECIAL, INDIRECT,
INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSSES, ARISING FROM ANY CAUSE OR
THEORY. Since some states or countries do not allow the exclusion or
limitation of an implied warranty or of incidental or consequential damages,
this limitation of liability may not apply to you.
Repair
All Beha-Amprobe tools returned for warranty or non-warranty repair or for
calibration should be accompanied by the following: your name, company’s name,
address, telephone number, and proof of purchase. Additionally, please include
a brief description of the problem or the service requested and include the
test leads with the meter. Non-warranty repair or replacement charges should
be remitted in the form of a check, a money order, credit card with expiration
date, or a purchase order made payable to Beha-Amprobe.
In-Warranty Repairs and Replacement – All Countries
Please read the warranty statement and check your battery before requesting
repair. During the warranty period, any defective test tool can be returned to
your Amprobe distributor for an exchange for the same or like product. Please
check the “Where to Buy” section on amprobe.com for a list of distributors
near you. Additionally, in the United States and Canada, in-warranty repair
and replacement units can also be sent to an Amprobe Service Center (see
address below).
Non-warranty Repairs and Replacement – Europe
European non-warranty units can be replaced by your Beha-Amprobe distributor
for a nominal charge. Please check the “Where to Buy” section on beha-
amprobe.com for a list of distributors near you.
Beha-Amprobe
Division and reg. trademark of Fluke Corp. (USA)
Germany*
In den Engematten 14
79286 Glottertal
Germany
Phone: +49 (0) 7684 8009 – 0
beha-amprobe.de| United Kingdom
52 Hurricane Way
Norwich, Norfolk
NR6 6JB United Kingdom
Phone: +44 (0) 1603 25 6662
beha-amprobe.com| The Netherlands – Headquarters**
Science Park Eindhoven 5110
5692 EC Son
The Netherlands
Phone: +31 (0) 40 267 51 00
beha-amprobe.com
---|---|---
*(Correspondence only – no repair or replacement available from this address. European customers please contact your distributor.)
**single contact address in EEA Fluke Europe BV
- Flash light
- LCD Display
- Function Buttons
- Flash light Button
- Rotary Switch
- SELECT Button
- Input Terminal for voltage, diode, capacitance, Resistance, continuity and temperature measurement
- COM (return) terminal for all measurements
- Input Terminal for AC/DC mA/uA measurement
- Input Terminal for AC/DC A measurement to10A
Screen Display
1 The Meter selects the range with best resolution
2 Direct Current
3 Negative reading
4 Alternate Current
5 Low battery indicator
6 Data hold
7 Diode test
8 Continuity test
9 Relative zero mode
10 Non-Contact Voltage| 11 Measurement units for Resistance
12 Measurement units for Frequency
13 Measurement units for Voltage
14 Measurement units for Current
15 Measurement units for Capacitance
16 Auto Power Off
17 Maximum / minimum reading memory
18 Measurement unit for Temperature
19 Analog bar graph display
---|---
SYMBOLS
| Caution ! Risk of electric shock.
---|---
| Caution! Refer to the explanation in this Manual
| Alternating Current (AC)
| Direct Current (DC)
| The equipment is protected by double insulation or reinforced
| Earth (Ground)
| Audible tone
| Battery
| Complies with European Directives
| Conforms to relevant Australian standards
| Canadian Standards Association (NRTL/C)
| Do not dispose of this product as unsorted municipal waste.
Contact a qualified recycler.
SAFETY INFORMATION
The Meter complies with:
IEC/EN 61010-1 3rd Edition, UL61010-1 2nd Ed. and CAN/CSA C22.2 No.
61010.1-0.92 to Category III 600 Volts, Pollution degree 2
IEC/EN 61010-2-030
IEC/EN 61010-2-31 for test leads
EMC IEC/EN 61326-1
Measurement Category III (CAT III) is for measurements performed in the
building installation. Examples are measurements on distribution boards,
circuit- breakers, wiring, including cables, bus-bars, junction boxes,
switches, socket-outlets in the fixed installation, and equipment for
industrial use and some other equipment, for example, stationary motors with
permanent connection to the fixed installation.
Measurement Category II (CAT II) iis for measurements performed on circuit
directly connected to low voltage installation. Examples are measurements on
household appliances, portable tools and similar equipments.
Warning: Read Before Using
- To avoid possible electrical shock or personal injury, follow these instructions and use the Meter only as specified in this manual.
- Do not use the Meter or test leads if they appear damaged, or if the Meter is not operating properly. If in doubt, have the Meter serviced.
- Always use the proper function and range for measurements. Before rotating the function range selection switch, disconnect test probe from circuit under test.
- Verify the Meter’s operation by measuring on a known voltage source.
- Do not apply more than the rated voltage, as marked on the Meter, between the test probe or between any test probe and earth ground.
- Use the Meter with caution for voltages above 30 Vac rms, 42 Vac peak, or 60 Vdc. These voltages pose electrical shock hazards.
- Disconnect circuit power and discharge all high-voltage capacitors before testing resistance.
- Do not use the Meter around explosive gas or vapor.
- When using the test leads, keep your fingers behind the finger guards.
- Remove test leads from the Meter before opening the Meter case or battery door.
UNPACKING AND INSPECTION
Your shipping carton should include:
1 AM-520-EUR or AM-530-EUR
1 Pair of test leads
1 Temperature probe
1 Velcro strap
1 9V (6F22) battery (installed)
1 User manual
1 Carrying case
If any of the items are damaged or missing, return the complete package to the
place of purchase for an exchange.
FEATURES
AM-520-EUR is designed for HVAC applications with key functions such as
temperature, micro amps used for flame sensor troubleshooting, as well as and
capacitance to check the motor startup capacitors. The AM-520-EUR measures a
complete range of electrical parameters and features a built in flashlight, a
“third hand” probe holder and VoltTect non-contact voltage detection. Safety
rated to CAT III 600V.
AM-530-EUR is the fully-featured multimeter of choice for the professional
electrical contractor. Measure and verify presence of voltage in order to
connect equipment or to perform repairs, run new wiring, check continuity of
electrical connections, identify blown fuses, troubleshoot motors or check
transformers. The AM-530-EUR features Truerms sensing to accurately measure
voltage on systems affected by harmonics, a built in flashlight to detect wire
colors in the dark, a “third hand” probe holder and non-contact voltage
detection. Safety rated to CAT III 600V.
-
Measurements: Voltage up to 600VAC and 600VDC, AC/DC current, Resistance, Frequency, Capacitance, Temperature.
-
Frequency, Capacitance, Duty Cycle for troubleshooting applications
-
Special Functions:
– Non-contact Voltage Detection
– Audible continuity
– Diode Test -
Backlit LCD display with analog bar graph
-
Events:
– Data hold
– MAX / MIN Memory
– Relative zero mode -
Built in work light (flashlight)
-
Built in test leads storage and “third hand holder”
-
Auto and Manual ranging
-
Auto power off
-
Low battery warning
-
Velcro strap to hang a meter
-
Safety: CAT III 600V
MAKING MEASUREMENT
-
Use the proper function and range for measurements.
-
To avoid possible electrical shock, personal injury or damages to the Meter, disconnect circuit power and discharge all high-voltage capacitors before testing resistance and diode.
-
Connecting test leads:
• Connect the common (COM) test lead to the circuit before connecting the live lead;
• After measurement, remove live lead before removing the common (COM) test lead from the circuit -
Symbol “OL” is displayed on LCD when the measurement is out of range.
Rotary Switch Positions
Switch Position | Measurement Function |
---|---|
AC or DC voltage measurement (use SELECT button for switching to AC or DC). | |
Resistance measurement | |
Voltage measurement of diode PN junction | |
Continuity measurement | |
Capacitance measurement | |
Hz | Frequency measurement |
°C °F | Temperature measurement |
NCV | Non-contact voltage |
AC or DC current measurement (use SELECT button for switching to AC or DC). |
Function Buttons
Button | Measurement Function |
---|---|
SELECT | Switching AC or DC. Press the yellow SELECT button to select |
alternate measurement functions on the rotary switch.
| Display freezes present reading / press 2 sec to turn on LCD backlight.
| Relative zero mode
RANGE| Manual or Auto range switching. The default setting is Auto
ranging, press to switch to manual ranging (selectable resolutions). Press for
2 sec to return to auto ranging.
MAX/MIN| Maximum / minimum reading memory.
| Flash light
Press to enable the function when at relevant rotary switch function.
Auto Power OFF
Auto power off: approx. 15 minutes.
When the Meter is in auto power off mode, press any button to resume normal
operation.
Measuring AC and DC Voltage
Press SELECT button to select AC/DC voltage measurement function.
To avoid personal injury or damage to the Meter, do not apply voltage higher
than 600Vac and 600Vdc. Measuring AC and DC Current
Press SELECT button to select AC or DC current measurement function.
To avoid personal injury or damage to the Meter:
- Do not attempt to make an in-circuit current measurement when the open-circuit potential to earth ground exceeding AC 600V or DC 600V
- Switch to proper function and range for your measurement.
- Do not place the test probe in parallel with a circuit when the test leads are connected to the current terminals.
- Connect the test leads to the correct input A/mA μA current terminal and to the circuit before powering the circuit under test.
- For current range from 8-10A, do not measure current for more than 20 minutes. Wait for 10 minutes before taking another measurement
- After measurement, switching OFF the circuit’s power before removing test leads from the circuit.
Measuring Resistance
Disconnect circuit power and discharge all high-voltage capacitors before
testing resistance. Note: On a higher resistance measurement (>1MΩ), the
measurement may take a few seconds to get stable reading.
Over range or open circuit indication: OL
Measuring Continuity
Disconnect circuit power and discharge all high-voltage capacitors before
testing continuity. Measuring Diode
Disconnect circuit power and discharge all high-voltage capacitors before
testing diode. Measuring Capacitance
Disconnect circuit power and discharge all high-voltage capacitors before
testing capacitance. Measuring Frequency
To avoid personal injury or damage to the Meter, do not apply voltage higher
than 600V. Measuring Temperature °C / °F
- To avoid personal injury or damage to the Meter, do not apply thetemperature probe to any live conductive parts.
- Temperature sensor K type (nickel-chromium/nichrosi) thermocouple is suitable for temperature measurement below 230°C (446°F).
Measurement steps:
Step 1: Turn the rotary switch to °C or °F position. The display will
show “OL”.
Step 2: Connect the temperature probe (K type) to the Meter and to the
surface to be measured. Non-Contact Voltage Sensing
- To avoid personal injury or damage to the Meter, do not test on uninsulated high voltage wires.
- Buzzer will sound and screen will display “OL” when sensing AC voltage between 90V and 600V
- Do not test on hazardous live wires higher than AC 600V
- Before and after hazardous voltage measurements, test the Meter by approaching to a known source such as a line AC voltage or outlet to determine proper operation. See below figure.
Buzzer will sound when the detected voltage is ≥ 90V, and the buzzer will be
on.The distances between the wire and the meter should be ≤ 8mm.
At NCV mode, LCD will display OL. No test lead connection are required for NCV
measurement.
SPECIFICATION
Ambient temperature: 73.4°F ±9 (23°C ±5°C); Relative temperature: ≤ 75%
Accuracy: ±(% of reading + digits)
Maximum voltage between input terminal and earth ground: AC 600Vrms or DC 600V
Fuse for mA µA input: F1 fuse, 0.5A H 1000V fast-fuse, (6.3×32)mm
Fuse for 10A input: F2 fuse, 11A H 1000V fast-fuse, (10×38)mm
Maximum display: Digital 3999 counts, updates 3/sec. Frequency: 9999 counts.
Analog pointer display: 41 segments, updates 30 times/sec.
Over-range indication: OL
Range: Automatic and Manual
Altitude: Operating 2000m
Operating temperature: 0°C ~ +40°C (32°F ~ 104°F)
Relative humidity: 0°C ~ +30°C (32°F ~ 86°F) ≤ 75%; +30°C ~ +40°C (86°F ~
104°F) ≤ 50%
Storage temperature: -10°C ~ +50°C (14°F ~ 122°F)
Electromagnetic compatibility: In an RF filed of 1V/m = Specified accuracy 5%
Battery: 9V, 6F22, NEDA1604 or equivalent
Low battery indication:
Dimensions (L x W x H): 182 mm x 90 mm x 45 mm (7.2 in x 3.5 in x 1.8 in)
Weight: Approx. 354g (0.78lb) with batteries installed
1. DC Voltage Measurement
Range | Resolution | Accuracy |
---|---|---|
400.0mV | 0.1mV | ± (0.8%+3LSD) |
4.000V | 1 my | ± (0.8%+1 LSD) |
40.00V | 10mV | |
400.0V | 100mV | |
600V | 1V | ±(1.0%+3LSD) |
Input impedance: About 10M ;
(Input impedance is ≤ 3G Ωexcept DC 400mV range)
Overload protection: ±600V
2. AC Voltage Measurement
Range | Resolution | Accuracy |
---|---|---|
400.0mV | 0.1mV | ±(1.2%+3LSD) |
4.000V | 1mV | ±(1.0%+3LSD) |
40.00V | 10mV | |
400.0V | 100mV | |
600V | 1V | ±(1.2%+3LSD) |
Note: Manual range only for 400.0mV range.
Input impedance: Around 10M Ω
Frequency response: 45Hz ~ 400Hz
AM-520-EUR : Average sensing, rms indication.
AM-530-EUR: True RMS.
Overload protection: 600Vrms
3. Resistance Measurement
Range | Resolution | Accuracy |
---|---|---|
400.0Ω | 0.1Ω | ±(1.2%+2LSD) |
4.000kΩ | 1Ω | ±(1.0%+2LSD) |
40.00kΩ | 10Ω | |
400.0kΩ | 100Ω | |
4.000MΩ | 1kΩ | ±(1.2%+2LSD) |
40.00MΩ | 10kΩ | ±(1.5%+5LSD) |
400Ω range: Measured value = (Measured display value – Short-circuiting value
of probe)
Open circuit voltage: Around 0.5V
Overload protection: 600Vrms
4. : Circuit ON/OFF : Diode measurement
Range | Resolution | Accuracy |
---|---|---|
0.1Ω | Open circuit voltage is around 0.5V. |
Resistance >150Ω , buzzer will not sound.
Resistance ≤ 10Ω , buzzer will sound.
| 1mV| Display range is 0V to 2.0V. Normal voltage is around 0.5V to 0.8V for
silicon PN junction.
Overload protection: 600V
5. Capacitance Measurement
Range | Resolution | Accuracy |
---|---|---|
40.00nF | 10pF | ±(3%+10LSD) under REL status |
400.0nF | 100pF | ±(3%+5LSD) under REL status |
4.000pF | 1nF | |
40.00pF | 10nF | ±(3%+5LSD) |
400.0pF | 100nF | ±(4%+5LSD) |
4000pF | 1pF | For reference only |
Overload protection: 600V
6. Frequency Measurement
Range | Resolution | Accuracy |
---|---|---|
10Hz~10MHz | 0.01Hz~0. 01MHz | ±(0.1%+4LSD) |
Overload protection: 600Vrms
7. DC Current Measurement
Range | Resolution | Accuracy |
---|---|---|
NA | 400.0pA | 0.1pA |
4000pA | 1pA | |
mA | 40.00mA | 10pA |
400.0mA | 0.1mA | |
A | 4.000A | 1 mA |
10.00A | 10mA |
Overload protection:
mA /µA range:F1 fuse, 0.5A H 1000V fast-fuse, ( Φ 6.3×32)mm
10 A range:F2 fuse, 11A H 1000V fast-fuse, ( Φ 10×38)mm
8. AC Current Measurement
Range | Resolution | Accuracy |
---|---|---|
NA | 400.OpA | 0.1pA |
4000pA | 1pA | |
mA | 40.00mA | 10pA |
400.0mA | 0.1mA | |
A | 4.000A | 1 mA |
10.00A | 10mA |
Frequency response: 45Hz ~ 400Hz
AM-520-EUR : Average sensing, rms indication.
AM-530-EUR: True RMS.
Overload protection:
mA /µA range:F1 fuse, 0.5A H 1000V fast-fuse, ( 6.3×32)mm
10 A range:F2 fuse, 11A H 1000V fast-fuse, ( 10×38)mm
9. Temperature Measurement
Range | Resolution | Accuracy |
---|---|---|
-40 – 0°C | 0.1°C @< 400°C | |
1°C @ 400°C | ±(10%+4°C) | |
>0 – 100°C | ±(1.2%+3°C) | |
>100 – 1000°C | ±(2.5%+2°C) | |
-40 – 32°F | 0.1°F @< 752°F | |
1°F © 752°F | ±(20%+6°F) | |
>32 – 212°F | ±(1.8%+6°F) | |
>212 – 1832°F | ±(2.5%+4°F) |
Overload protection: 600V
K type (nickel-chromium/nichrosi) thermocouple must be used for temperature
measurement.
MAINTENANCE AND REPAIR
If the Meter fails to operate, check battery, test leads, etc., and replace as
necessary.
Double check the followings:
- Replace the fuse or battery if the meter does not work.
- Review the operating instructions for possible mistakes in operating procedure.
Quick check on 0.5A FUSE:
Step 1: Turn the rotary switch to Ω function.
Step 2: short-circuit E /V/Ω/Hz terminal and mA/μA terminal.
Resistance reading ≤ 1M Ω : the fuse is OK
Resistance reading “OL”: the fuse is open. Replace the fuse as specified.
Quick check on 10A FUSE:
Step 1: Turn the rotary switch to Ω function.
Step 2: short-circuit E/V/Ω/Hz terminal and A terminal.
Resistance reading ≤ 0.5Ω : the fuse is OK.
Resistance reading “OL”: the fuse is open. Replace the fuse as specified.
Except for the replacement of the battery, repair of the meter should be
performed only by a Factory Authorized Service Center or by other qualified
instrument service personnel.
The front panel and case can be cleaned with a mild solution of detergent and
water. Apply sparingly with a soft cloth and allow to dry completely before
using. Do not use aromatic hydrocarbons, Gasoline or chlorinated solvents for
cleaning.
BATTERY AND FUSE REPLACEMENT
WARNING
To avoid shock, injury, or damage to the Meter:
Disconnect test leads before opening case.
Use ONLY fuses with the amperage, interrupt, voltage, and speed ratings
specified.
Replacing BATTERY follow below steps:
-
Disconnect the test lead probe from measuring circuit.
-
Turn the Meter to OFF position.
-
Remove the screws from the battery cover and open the battery cover
-
Remove the batteries and replace with one 9V (6F22) or equivalent. The battery cover provides the correct polarity fitting construction design.
Install the battery in the battery cover. -
Put the battery cover back and re-fasten the screw.
Battery: 9V (6F22) Battery or equivalent
Replacing FUSE follow below steps:
- Disconnect the test lead probe from measuring circuit.
- Turn the Meter to OFF position.
- Remove the screws from the enclosure and open the enclosure.
- Remove the broken fuse and replace with new specified fuse.
- Put the enclosure back and re-fasten the screw.
Fuse ratings:
mA /µA input terminal: F1 fuse, 0.5A H 1000V fast-fuse, (Φ 6.3×32)mm
10 A input terminal: F2 fuse, 11A H 1000V fast-fuse, (Φ 10×38)mm Visit beha-
amprobe.com for
- Catalog
- Application notes
- Product specifications
- User manuals
beha-amprobe.com
c/o Fluke Europe BV
Science Park
Eindhoven 5110
NL-5692 EC Son
Tel.: +49 (0) 7684 8009 – 0
References
- Amprobe | Electrical Test and Measurement Tools
- Beha-Amprobe: The answer to all electronics, electrical and predictive maintenance questions
- Beha-Amprobe: Die Antwort auf alle Fragen in den Bereichen Elektronik, Elektrik und vorausschauende Instandhaltung
- Manual-Hub.com – Free PDF manuals!