Product Information

Specifications

  • Product Name: TruGroove Recessed
  • Model: ID-39
  • Mounting: T-Grid Ceiling System
  • Light Direction: Asymmetric or Symmetric
  • Lens Type: Flush or Regressed
  • Tools Required: Phillips screwdriver, 5/16 Nut Driver
  • Compliance: Class A digital device, FCC Rules Part 15

FAQs

  • Q: What tools are required for installation?
    • A: Phillips screwdriver and 5/16 Nut Driver.
  • Q: Can the fixtures be installed in a residential area?
    • A: The fixtures are designed for commercial environments. Installing them in a residential area may cause harmful interference with radio communications.

Standalone or Continuous Run in T-Grid Ceiling

System Overview

These instructions review how to install TruGroove recessed fixtures in T-Grid ceilings. Please refer to layout drawings supplied by Ledalite in conjunction with these installation instructions. The graphics below show the components required.

IMPORTANT: Read all instructions including fixture/sensor wiring AND mechanical details before beginning installation.

Ledalite-Signify-ID-39-TruGroove-Recessed-fig-1

Hanger Kit 390ZK01

**Joint Kit 390JK01***

Ledalite-Signify-ID-39-TruGroove-Recessed-fig-3

**Joint Kit 390JK03***

Ledalite-Signify-ID-39-TruGroove-Recessed-fig-4

Note: One kit required for each joint. Joint kit type determined by flush or regressed lens mounting and symmetric or asymmetric light distribution. Tools: Phillips screwdriver, 5/16” Nut Driver

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

Important Notes

Warning, Shock Hazard

  • Fixture must be connected to building ground via the provided ground wire before connecting to mains power supply.
  • Disconnect or turn off power before attempting any installation, service or maintenance.

Prepare Fixtures

  • Arrange boxed fixtures on floor in specified mounting locations, based on supplied layout drawings.
  • Remove fixtures from boxes.
  • Remove plastic from fixtures.
  • Match up each fixture and lens based on the spec tag and ID number labelled on each fixture box for the specified run.

T-Grid

Ledalite-Signify-ID-39-TruGroove-Recessed-fig-6

  • Install main T’ s, 4” on center. For continuous row lengths, refer to supplied layout drawings. Add 1/4 “ to the overall housing length indicated on your layout drawings.
  • Position the cross T.

Install Fixtures

Install Mounting Brackets

Ledalite-Signify-ID-39-TruGroove-Recessed-fig-7

Important: Install T-Grid mounting brackets to required height.

Install Fixture Above T-Bar Grid

Ledalite-Signify-ID-39-TruGroove-Recessed-fig-8

  • Install the first fixture (or Standalone Unit) from above the T-Bar Grid.

NOTE

  • For Standalone fixtures skip to step 7

Install Joiner Aligners

Ledalite-Signify-ID-39-TruGroove-Recessed-fig-9

  • Important: To insert aligners, tap gently with a hammer until half is inserted into the joiner channel. Be sure to engage the dimple.

Complete Wiring and Connect Fixtures

  • Install the joiner fixture into the T Bar Grid from above. Complete wiring and slide the fixtures together.

Install Joiner Brackets

  • Important: Hand tighten bracket screws while supporting the housing on the opposite side. Gradually alternate sides while tightening.
  • Do not over tighten.

Secure the Fixture

Ledalite-Signify-ID-39-TruGroove-Recessed-fig-12

  • Secure the fixture hanger brackets to the T-Bar grid.
  • For continuous runs, finish installing run first and then secure to the T-Bar grid.

Install Power Drop

  • Install power drop at desired location. At the power location(s), remove factory installed wire cover. Feed power wires through. Complete all wiring connections.

Re-install Wire Cover

Ledalite-Signify-ID-39-TruGroove-Recessed-fig-14

  • Re-install wire cover and slide to lock. Install screw.

Install Seismic Restraints

Ledalite-Signify-ID-39-TruGroove-Recessed-fig-15

  • Install seismic restraints according to local building code requirements.

11a. Secure Joint Cover
Flush lens and Symmetric

Ledalite-Signify-ID-39-TruGroove-Recessed-fig-16

  • At joint location(s), secure joint covers using Philips screwdriver and supplied hardware.
  • Ensure cover plates sit flush with bottom reflectors for proper LED board fit.

11b. Secure Joint Cover
Regressed lens or Asymmetric

Ledalite-Signify-ID-39-TruGroove-Recessed-fig-17

  • At joint location(s), secure joint covers using Philips screwdriver and supplied hardware.
  • Ensure cover plates sit flush with bottom reflectors for proper LED board fit.

12a. Flush Lens Installation and Removal

Ledalite-Signify-ID-39-TruGroove-Recessed-fig-18

  • Flush Lens: Snap in lens into fixture.
  • Lens Removal: To remove snap in lens for maintenance purposes, insert a flat, smooth edged object between lens and housing. Twist to release pressure and remove lens.

12b. Regressed Lens Installation

Ledalite-Signify-ID-39-TruGroove-Recessed-fig-19

  • Regressed Lens: Angle lens to insert into fixture. Lay lens on aluminum extrusion flange.
  • Ensure lens engages between lens retaining clips to prevent movement of lens.

NOTE

  • Please refer to layout drawing and match up each lens based on the ID number.

ATTENTION

  • Install in accordance with local and national building and electric codes.

Sensors in Rows

Single Sensor Controlling Whole Row

Ledalite-Signify-ID-39-TruGroove-Recessed-fig-20

  1. Purple & brown (or purple & grey/pink) control wires MUST be connected between fixtures.

Note

  • A maximum of 8 drivers can be wired to one sensor; confirm fixture driver count with factory.

Multiple Sensors Controlling Separate Zones in a Row

Ledalite-Signify-ID-39-TruGroove-Recessed-fig-21

  1. Purple & brown (or purple & grey/pink) control wires MUST NOT be connected between zones.

Notes

  • A maximum of 8 drivers can be wired to one sensor; confirm fixture driver count with factory.
  • Only one sensor is allowed on a wired zone. (Sensors can be paired together wirelessly via a mobile app).

Sensor Spacing

Ledalite-Signify-ID-39-TruGroove-Recessed-fig-22

  • For correct operation, sensors should be placed a minimum distance of 8ft apart.
  • Wireless sensors should be placed no further than 40ft apart for good wireless signal connection.

Important Consideration When Using Sensors in a Row

  • For fixtures with wireless sensors (CS, SB or RA options): DO NOT connect fixture purple & brown (or purple & grey/pink) control wires to an external dimming switch.
  • Fixture mains wiring should not be connected to a circuit with an external on/off switch.
  • For best aesthetic condition, place sensors at ends of row only so as not to break the continuous lens.
  • For better occupancy coverage in longer rows, sensors may be placed mid run, but keep in mind this will break the continuous lens into discrete sections. Alternatively, remote sensor may be used, note the same wiring rules will apply.

Occupancy Sensor Coverage:

Ledalite-Signify-ID-39-TruGroove-Recessed-fig-23

Note: Longer dimension of detection area (Y1, Y2) is parallel to longer dimension of the luminaire.

Daylight sensor

The light sensor measures the total amount of light in a circular field of approximately 80% of the PIR detection area. The following aspects should be observed during installation:

  • Minimum distance from the window ≥2ft (0.6m).
  • Prevent light reflections from outside entering the sensor (for example sunlight reflection on a car hood) as this will lead to incorrect light regulation.

As a guideline the formula 0.72 x H can be used to calculate the minimum distance between the window and sensor whereby H is the height from the bottom of the window to the sensor.

Ledalite-Signify-ID-39-TruGroove-Recessed-fig-24

The detection area for the movement sensor can be roughly divided into two parts:

  • Minor movement (person moving ≤3ft/s or 0.9m/s).
  • Major movement (person moving ≥3ft/s or 0.9m/s).

Photosensor spatial response

Ledalite-Signify-ID-39-TruGroove-Recessed-fig-25

ATTENTION: Install in accordance with local and national building and electric codes.

© 2021 Signify Holding. All rights reserved. The information provided herein is subject to change, without notice. Signify does not give any representation or warranty as to the accuracy or completeness of the information included herein and shall not be liable for any action in reliance thereon. The information presented in this document is not intended as any commercial offer and does not form part of any quotation or contract, unless otherwise agreed by Signify.

Contact

Signify North America Corporation

  • 400 Crossing Bivd, Suite 600 Bridgewater, NJ 08807
  • Telephone: 855-486-2216

Signify Canada Ltd.

  • 281 Hillmount Road, Markham, ON, Canada L6C 253
  • Telephone: 800-668-9008

www.signify.com

www.ledalite.com

All trademarks are owned by Signify Holding or their respective owners.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Ledalite - Signify User Manuals

Related Manuals