DynaScan DS491LT5 Professional Screen User Manual

June 17, 2024
DynaScan

DynaScan logo USER MANUAL
DS491LT5
49” Fanless High Brightness Display

Please read this manual carefully before operating the product and keep it for future reference.
The use of diagrams and illustrations in the manual are for reference only, the actual product may be different.

DynaScan DS491LT5 Professional Screen

FOR MORE INFORMATION
For more information about DynaScan, visit our website at www.dynascandisplay.com.
Copyright © DynaScan Technology Inc.
All rights reserved.
All specifications and descriptions are subject to change without notice. Reproduction without permission is prohibited.
64907 | V2.10

Material Contents Declaration

Part Name Hazardous Substances
Lead Mercury
Polybrominated Biphenyls Polybromodiphenyl Ethers
Pb Hg
PCBA O
CHASSIS O
ACCESSORY O
PACKAGE O

“O” indicates that the level of the specified chemical substance is less than the threshold level specified in the standards of SJ/T-11363-2006 and EU 2005/618/EC.
“?” indicates that the level of the specified chemical substance exceeds the threshold level specified in the standards of SJ/T-11363-2006 and EU 2005/618/EC.

Recycling and Energy Information

DynaScan is firmly committed to its environmental protection efforts and we believe that reducing our products’ impact on the environment is of the utmost importance. We are dedicated to meet the latest environmental protection regulations.

Energy usage

Mode Energy Consumption
Normal Max. 250 W
Standby < 1 W

Disposal
Do not dispose of electrical appliances as unsorted municipal waste, use separate collection facilities.
Contact your local government for information regarding the collection systems available. If electrical appliances are disposed of in landfills or dumps, hazardous substances can leak into the groundwater and get into the food chain, damaging your health and well-being. When replacing old appliances with new one, the retailer is legally obligated to take back your old appliances for disposal at least for free of charge.

LICENSES

The terms HDMI and HDMI High-Definition Multimedia Interface, and the HDMI Logo are trademarks or registered trademarks of HDMI Licensing Administrator, Inc.

Declaration of Conformity

FCC
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

FEDERAL COMMUNICATIONS COMMISSION INTERFERENCE STATEMENT
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

CAUTION:
Any changes or modifications not expressly approved by the grantee of this device could void the user’s authority to operate the equipment.

RF exposure warning
This equipment must be installed and operated in accordance with provided instructions and the antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users and installers must be provide with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

Manufacturer Name DynaScan Technology Corp.
Manufacturer Address 6F, No. 88 Wenmao Rd., Guishan Dist, Taoyuan City

333001,Taiwan


This device complies with Directive 2014/53/EU issued by the Commission of the European Community.

Article 3.1 (a)
EN 62368-1 :2014+A11 :2017
IEC 62368-1 :2014 (Second Edition)
Article 3.2
EN 300 328 V2.2.2 (2019-07)
EN 62311 :2008| Article 3.1
EN 55032 :2015+A11 :2020,Class A
EN IEC 61000-3-2 :2019
EN 61000-3-3 :2013+A1 :2019
EN 55035 :2017
EN 301 489-1 V2.2.3
EN 301 489-17 V3.2.4
---|---

– Frequency bands and Powers
a. WIFI 2.4G-2412~2462MHz.
b. Maximum radio-frequency power transmitted in the 2.4GHz is 50mW.

Safety Precautions

CAUTION

| Do not install near flammable material or any heat sources.
Do not defeat the safety purpose of the grounding-type plug.
Do not disassemble the display to avoid electrical shock or burn.
Normal operating condition considers installation at an altitude below 2000m; some abnormalities may be experienced when installed at an altitude above 2000m.

WARNING

  • Please power off the LCD and the video source before plugging in the DP or HDMI cable.
  • Please installed the display in well-ventilated place, do not install in a confined space.
  • Suitable for mounting on concrete or other non-combustible surface only.
  • If it gives off smoke, strange smell, or unusual noise, or when it gets too hot to touch, immediately unplug the display and contact the dealer.
  • Clean only with soft, dry cloth but not use chemical liquids, and unplug while cleaning.
  • Do not use extreme force or any sharp or pointed objects to touch the display.
  • Do not drop or allow any object to fall to the display.
  • Do not operate the display with wet hands to avoid electric shock.
  • Do not discard this product with general household waste. Please be sure to comply with the local waste regulations.
  • This device uses, generates and radiated radio frequency energy. The radio frequency energy produced by this device is well below the maximum exposure allows by Federal Communications Commission (FCC).
  • When a stationary or fixed image is displayed on the screen for a long time, the image may be permanently imprinted on the screen. This phenomenon is known as image burn-in and is not covered by the manufacturer’s warranty.
  • In order to avoid burn-in, avoid prolonged display of static or fixed images on the screen.
  • Power supply cord must not be attached to the building surface, nor run through walls, ceilings, floors and similar openings in the building structure.
  • Power cord shall be connected to a socket-outlet with earthing connection.

Important Safety Information

  • Disassembling the LCD is strictly prohibited. Opening the cover may expose the user to electric shock or other hazards. Please contact DynaScan certified service professionals for all maintenance requirements.
  • Do not allow any liquid to enter the LCD. Also avoid placing the LCD close to water sources.
  • Do not place heavy objects on the power cord. A damaged power cord might cause electric shock or fire.
  • Do not bend, twist, or damage the power cord.
  • The power cord must comply with the local safety regulations.
  • Do not damage or modify the prongs/pins and the ground contact on the power cord plug.
  • Do not place the LCD on an unleveled surface or an unstable vehicle. The LCD could fall over and cause substantial damage.
  • Do not cover the vents and/or the heat sink.
  • Do not install the LCD beside radiators or other heat sources. The installation site should have sufficient ventilation so the heat generated by the LCD can be dissipated.
  • Do not use the Signage in a hot, humid, dusty, or fumy environment.
  • Handle the LCD with care. Save the packaging materials for transport later.
  • Clean the LCD backside at least once a month for dust and other particles.

Unplug the LCD immediately and contact a DynaScan certified service professional as soon as possible when any of the following situations occurs:

  • Damaged power cord or power plug.
  • If liquid or foreign object has entered the LCD.
  • If the LCD has been exposed to rain or water.
  • If the LCD has been dropped or the casing has become damaged.
  • If any structural damage such as cracks or unnatural vibration is found.
  • If the LCD cannot be operated following the steps outlined in this manual.
  • If the LCD emits smoke or other odors, or generates strange noises.

Operating Suggestions

  • Avoid displaying a stationary image for a long period of time in order to prevent image sticking.

Cleaning the Panel

  • Use a soft, lint-free cloth to gently wipe the dust off from the screen panel.
  • Do not use any hard material to wipe the panel.
  • Do not poke the panel with your hand or any sharp object (such as a pen or a nail) or exert excessive pressure on the panel to prevent any damage.
  • Do not use any cleaning solutions on the panel as it might cause discoloration.

Cleaning the Casing

  • Unplug the power cord.
  • Gently wipe the casing with a soft cloth.

Attention

  • Do not use any of the following solutions to clean the casing as they may damage the paint and cause it to crack or peel: benzene solution, alkaline solution, alcohol-based cleaning solution, glass cleaner, wax, polisher, or detergent.

Getting Started

Contents
Confirm that the accessories below are shipped along with the display. If any item is missing, please contact your dealer. The color and shape of the accessories may vary with the products.

  • DS491LT5 Professional LCD.
  • Remote Control x 1 pc.
  • Batteries (1.5V / AAA) x2 pcs.
  • Power cable x1 pc.
  • Quick Start Guide x1 pc.
  • ESK302 x1 pc.

Attention: Please use the following table to check whether the included power cord is suitable for your region. If the power cord does not match your region, please contact your local supplier. Please use matching AC socket in order to meet your local safety regulations.

Plug Type| North America| European Continental| Japan| Taiwan
---|---|---|---|---
Plug Shape| | | |
Region| U.S.A. / Canada| EU (Except U.K.)| Japan| Taiwan
Voltage| 120V| 230V| 100V| 110V
NEMA TYPE| NEMA 5-15| CEE 7/7| NEMA 1-15| NEMA 5-15
IEC Display Plug|
IEC Plug TYPE| IEC320 C13

Installing and Replacing Remote Control Batteries

  1. Open the battery compartment cover.
  2. Insert 2 new AAA batteries.
  3. Close the battery compartment cover.

Warning:

  • Incorrect usage of batteries may cause leakage or explosion.
  • Pay attention to the polarity when installing the batteries.
  • Do not mix different types of batteries or new and used batteries. Doing so may shorten the battery life or cause leakage.
  • Remove or replace the batteries when they are empty in order to prevent acid leaking in the battery compartment.
  • Do not touch the leaked substance from the batteries in case of a battery leakage. Doing so may hurt human skin.

Note: If the remote control is not going to be used for a long time, we recommend removing the batteries from the remote control.

Installation

The LCD must be properly installed using a wall mount. Incorrect installation may cause injury or damage the equipment. Product warranty does not cover the damage caused by improper installation and DynaScan shall not be held responsible in such incident. Refer to the mount manufacturer’s instructions for proper installation.

Mounting

  • We recommend for at least four people to handle and mount the display.
  • Mounting the Professional LCD on the wall is the responsibility of the user. Not all walls provide enough strength to support the LCD. The LCD may drop and cause serious injury if it is mounted on a slanted wall. Product warranty does not cover improper installation, modification, or damage caused by natural disasters. DynaScan recommends having certified professionals to evaluate the installation site and perform the mounting operation.’
  • Do not to cover the vent and/or the heat sink in order to ensure proper heat dissipation.
  • Refer to the installation guide provided by the manufacturer for proper mounting.

When mounting on a wall

  • A wall mount is not included in the accessory. Please purchase a VESA Standard wall mount to secure the LCD. DynaScan is not responsible for the damage caused by using non-standard wall mounts.
  • Verify that the mounting location can support the weight of the LCD before installation.
  • The installation angle must be within 15 degrees of the vertical axis.
  • Do not install the wall mount while the power is turned on as it may cause serious injury due to electrical shock.
Model Number VESA (mm) Screw Specification Screw Length Number
DS491LT5 (A * B) 400 * 400 M6 Greater than 10mm

Smaller than 12mm
(not including wall mount thickness)| 4

DynaScan DS491LT5 Professional Screen - Unit

Orientation

  • When used in the portrait orientation, the LCD should be rotated clockwise when looking at the front of the display such that the left edge becomes the top edge.DynaScan DS491LT5 Professional Screen - Rotate the set clockwisePortrait mode: Rotate the set clockwise 90° (mandatory)
  • The orientation sticker can be found on the rear of display, which is for distinguishing the direction of installation.

DynaScan DS491LT5 Professional Screen - Symbol 4

Installation Location

  • The wall and mount must have enough strength to support the LCD and its accessories.
  • Do not install in a location with strong vibrations or dusty.
  • Do not install near the building’s main electric panel.
  • Ensure the LCD is secured in such a manner that it cannot be easily removed by the general public.
  • Leave clearance around the outer edge of the LCD (or video wall matrix) from other objects to ensure proper ventilation.

DynaScan DS491LT5 Professional Screen - Single display

Maintenance

  • Inspect the fasteners regularly for signs of loosening or deformation. Please perform appropriate corrective measures when a problem is identified. Neglecting the problem may worsen the situation.
  • Increase the inspection frequency on areas where previous maintenance had occurred to ensure the problems do not occur again.

Wall Mounting

  • A wall mount is not included. Please purchase a VESA Standard wall mount to secure the LCD.
    DynaScan is not responsible for damages caused by using non-standard wall mounts.

  • Verify that the mounting location can support the weight of the LCD before installation.

  • The installation angle must be within 15 degrees of the vertical axis.

  • Do not install the wall mount while the power is turned on as it may cause serious injury from electrical shock.

DynaScan DS491LT5 Professional Screen - Wall Mounting

Connecting to a Power Source
Using the power cable provided, plug it in the power inlet on the back of the display shown in the diagram below. Connect the power cable to a 100-240 volt, 50 / 60Hz AC power outlet.

Insert the plug completely into the socket. A loose power connection may cause damage to the display and/or lead to a fire hazard.

DynaScan DS491LT5 Professional Screen - Power Source

Connecting an External Video Source
Turn OFF the power of both LCD and external video device. Using the DP cable (or HDMI cable) provided, insert one end into the DP-IN (or HDMI 1-IN, HDMI 2-IN) on the back of the display shown the in the diagram below. Connect the other end of the DP cable (HDMI cable) to the DP output (or HDMI output) of the video source. Refer to your video device’s manual for additional information.

DynaScan DS491LT5 Professional Screen - External Video
Source

Input / Output Terminals

A. AC (IN): Connect the supplied power cord to the wall outlet.
B. Power Switch: Press to switch the main power on/off.
C. RJ-45 1 (IN): RJ45 network input connection.
D. RJ-45 2 (IN): RJ45 network input connection.
E. RS-232 (IN): RS232C network input connection for remote control from PC.
F. HDMI 1 (IN): Connect the HDMI output of a PC or an AV device via a HDMI cable.
G. HDMI 2 (IN): Connect the HDMI output of a PC or an AV device via a HDMI cable.
H. DP (IN): Connect the DP output of a PC or an AV device via a DP cable.
I. USB 3.0 port: Support for USB flash drive storage, mouse and keyboard.
J. Extension Connector: Extension Connector for optional IR Extension sensor kit (ESK302).
K. Micro SD card: Support for up to 128GB, FAT32 format is supported.
L. Thermal: Extension Connector for optional Extension thermal kit (ETK302).
M. Audio (OUT): Connect the audio signal output from Audio IN jack to an external AV device.

*USB 3.0 port: A standardized port to connect a variety of devices like mouse, keyboard, and flash drive. Support USB storage devices formatted with NTFS, FAT32 (32G) file system.

DynaScan DS491LT5 Professional Screen - Output
Terminals

Operating Instructions

Powering On/Off the Display
To turn on/off the display, press the power switch on the back of the display as shown in the diagram below.![DynaScan DS491LT5 Professional Screen

Using the Remote Control
Connection using an External Sensor Kit (ESK302)

Connect the ESK302 cable to the mini USB port on the side of the display, and aim the remote at the IR receiver as shown below. Meanwhile, the IR receiver on the display will be disabled. The operating range of the remote control is 2.5 meters (8 feet).

DynaScan DS491LT5 Professional Screen - External Sensor
Kit

NOTE: Ambient light may affect the performance of the remote control. Avoid fluorescent or neon lights in the vicinity.

DynaScan DS491LT5 Professional Screen - Remote

*Color and shape may vary by model.

ITEM DESCRIPTION
1 POWER Power On / Off
2 MENU OSD On / Off
3 UP Move the cursor up or change the setting of selected item.
4 LEFT Exit the current selection.
5 RIGHT Select the highlighted item.
6 DOWN Move the cursor down or change the setting of selected item.
7 OK Enter (for DSM365 only)
8 BACK Return to the last page. (for DSM365 only)

Using the built-in keypadDynaScan DS491LT5 Professional Screen - Using
the built-in keypad

ITEM DESCRIPTION
MENU OSD On / Off, Power On / Off.
UP Move the cursor up or change the setting of selected item.
DOWN Move the cursor down or change the setting of selected item.
LEFT Exit the current selection.
RIGHT Select the highlighted item.

Press the MENU button on the built-in keypad or remote control to show the OSD. Use the navigation arrows to select and adjust the menu items.
*The change of each setting can only enable when you press “LEFT” (refer to p.19) to back to the last menu layer.

  1. Input SourceDynaScan DS491LT5 Professional Screen - Input Source
    ITEM 1| ITEM 2| DEFAULT| DESCRIPTION
    ---|---|---|---
    Input Source| Main| HDMI 1| Set the Main input to display.
    Failover 1| HDMI 2| Set the Failover 1 input to display.
    Failover 2| DP| Set the Failover 2 input to display.
    Failover 3| DSM365| Set the Failover 3 input to display.
    Failback| OFF| Set the time (hour),when the Input Source is failover, it will redetection the Main Source per few hour.
    Command Detection| OFF| Only effective in Main input source.
    If the display didn’t get both of commend and the input signal, it will change to Failover1 input.
  2. PictureDynaScan DS491LT5 Professional Screen - Picture
    ITEM 1| ITEM 2| DEFAULT| DESCRIPTION
    ---|---|---|---
    Picture| Color Temperature| User| Adjusts the color temperature to preset or user determined values.
    (User, D55, D65, D93, Balanced)
    | Red| 100| Adjust the red light level. Range 0 – 100.
    Note : The feature is only supported on User mode.
    Green| 100| Adjust the green light level. Range 0 – 100.
    Note : The feature is only supported on User mode.
    Blue| 100| Adjust the blue light level. Range 0 – 100.
    Note : The feature is only supported on User mode.
    Contrast| 60| Adjust the contrast level. Range 0 – 100.
    Gamma| Native| Adjusts the Gamma value. (Native, 2.2, 2.4 and sGamma)
    Black Level| Limited| Selects the black level to adjust the screen gray scale. “Limited” for video source uses 16 to 235 levels for R/G/B, such as HDMI. “RGB Full” for video source uses all levels from 0 to 255 levels.
    “Auto” is for detecting the video source to determine its value is applicable for “Limited” or “RGB Full”.
  3. BrightnessDynaScan DS491LT5 Professional Screen - Brightness
    ITEM 1| ITEM 2| DEFAULT| DESCRIPTION
    ---|---|---|---
    Brightness| Auto Brightness| Fixed| Brightness Setting: Fixed:screen brightness remains at one level.
    Timer: Screen brightness is determined by the time of day. Auto:Screen brightness is determined by an extension sensor kit (ESK).
    Mix: Mix Timer & Auto Mode, Autosensor time screen brightness determined by an extension sensor kit (ESK); fixed time by timer.
    By Light Value: Screen brightness determined by ambient light values, up to 4 levels.
    By Time: Screen brightness determined by scheduled values, up to 4 levels.
    Backlight Level| 100|
    Local Dimming| High| Adjusts the contrast. High is the highest contrast. Low is the lowest contrast.
    (High, Low, Medium, OFF)
  4. TimeDynaScan DS491LT5 Professional Screen - Time
    ITEM 1| ITEM 2| DEFAULT| DESCRIPTION
    ---|---|---|---
    Time| Region| |
    Time Zone| | Set the Time Zone.
    Set Date & Time| | Set the mode.
    Current Time| | Set the clock.
    Note : The internal clock will continue to function when the power is turned off.
    Current Date| | Set the date.
    Day Of Week| | Set the day of week. (Monday to Sunday)
  5. ScheduleDynaScan DS491LT5 Professional Screen - Schedule
    ITEM 1| ITEM 2| DEFAULT| DESCRIPTION
    ---|---|---|---
    Schedule| Power ON|OFF Time| OFF| Automatic power on / off schedule function.
  6. AdvancedDynaScan DS491LT5 Professional Screen - Advanced
    ITEM 1| ITEM 2| DEFAULT| DESCRIPTION
    ---|---|---|---
    Advanced| Display Mode| Auto| Change the Menu orientation. The Menu can be displayed in either LANDSCAPE or PORTRAIT mode.
    Screen Protection| OFF| Turn on / off image burn-in protection.
    Set image burn-in protection interval. Range 0 – 100 minutes.
    IR Control| ON| Enable/disable the remote control for Menu.
    Note : When disabled, the remote control function can be enabled again from the control panel on the display or through the DynaScan “Display Manager” application.
    Power Restore Behavior| Power On| Choose to use the Power Restore Behavior function.
    Power On: Display booting up when the power back after an outage.
    Standby: Display keeps soft-off status when the power back after an outage.
    Memory: Display will back to the last state when the
    Auto Out Volume| 50| Set volume.
    Range 100 – 0.
    RS232 CMD Compatible| ON| RS232 Command compatibility between the current and last generation* model.
    * last generation model : DS371BT4、 DS491LT4、DS552LT4-1、DS552LT4-M、 DS552LT5、DS552LT6-1、DS552LT7、 DS551DR4、DI551ST2、DW551LR5、 DO552LR4、DO551LR4、DO552LR4-M、DI651ST2、DP652ST2、DP652LT5
    Schedule Reboot| OFF| Enable/disable the Schedule Reboot, And set the Time.
    OSD Password Protection| ****

OFF

| Turn On: Create Password > Confirm Password > Password Protection On   Turn Off: Enter Password > Password Protection Off
Export & Import Settings| | Export or Import OSD Setting by USB.
Reset Default Settings| | Restore all settings to default.
Note: It does not modify CURRENT TIME, POWER ON TIME and POWER OFF TIME.
7. InformationDynaScan DS491LT5 Professional Screen - Information
ITEM 1| ITEM 2| DEFAULT| DESCRIPTION
---|---|---|---
Information| Resolution| | Input resolution.
MCB Version| | The MCB version.
FW Version| | The Firmware version.
OS Version| | The OS version.
Thermal Kit Temp.| | The Extension Thermal Kit (ETK302) is for ambient temperature monitoring.

Some functions may not be available for all models.

Specifications

MODEL DS491LT5
PANEL LCD Panel Size
Native Resolution 1920 x 1080
Brightness 4,000 cd/m² (Typ.)
Contrast Ratio 3,000:1
Response Time 8 ms (Typ.)
Viewing Angle 178°/ 178°
Life Time 100,000 hrs (Typ.)
Panel Surface AR, 2H
POWER Power Supply
Rated Voltage 100 – 240V, 50 / 60Hz
Power On Mode 160W (Typ.) / 230W (Max.)
Standby Mode < 1W
MECHANICAL SPECS Bezel Width (T/B/L/R)
Cabinet Color Black
Monitor Dimension (LxHxD) 1096.7 x 627.2 x 82.3 mm
Monitor Weight (set / package) 19.6 kg / 26.5 kg
VESA Mounting (Dimension) 4 Holes (400×400 mm)
USER INTERFACE OSD Language
ENVIRONMENT Operation Temperature
Storage Temperature -20°C ~ 60°C
Humidity 10%~80% RH Non-Condensing
I/O Ports HDMI
DP IN *1
RS-232 IN *1
Audio OUT *1
USB port IN *1
RJ-45 IN *2
Micro SD Slot IN *1
Extension Connector (Mini USB) IN *1 (ESK only)
Fuse

Design and specifications are subject to change without notice.

Input Mode

Active Resolution Refresh Rate
H Pixels V Lines
640 480
720 480
800 600
960 600
1024 768
1280 720
1280 768
1280 960
1280 1024
1366 768
1400 1050
1440 900
1600 1200
1680 1050
1920 720
1920 1080

Pin Assignments

RS-232 Input

PIN No. NAME
01 Connected to 7&8
02 TXD
03 RXD
04 Connected to 6
05 GND
06 Connected to 4
07 Connected to 1&8
08 Connected to 1&7
09 NC

Troubleshooting

ISSUE RECOMMENDED SOLUTION
No image is displayed. ● Check whether the cable is completely plugged in.

● Check whether the main switch is in the ON position, and the power cord is completely plugged in.
● Check whether the image source’s resolution is set as the supported format (refer to section “Input Mode”, p.27).
● Check whether the cable is damaged or bent excessively.
Nothing happens when switching the main switch on.| ● Unplug the power cord from the socket and plug it in again after a few seconds to reset the Signage.
Note: Unplugging the power cord will not change the settings.
Image is unstable.| ● Check whether the cable is completely plugged in.
The remote control does not work.| ● Check whether there are batteries in the remote control.
● Check the batteries for freshness, polarity, etc.
● Check whether the remote is in the operation range.
● Bright light may interfere with the remote control. Please avoid using the remote control near special fluorescent lights or neon lights.
Auto on/off does not work or does not function properly.| ● Check whether the TIMER setting in the menu is set to “OFF”.
● Check whether the “Power On Time” and “Power Off Time” settings are set correctly.
Cannot control the display remotely via RS-232.| ● Check whether the RS-232 cable is connected properly.

If you are still having trouble with your DynaScan DS² Professional LCD, contact your dealer or DynaScan directly for more assistance.

About DSM365

DSM365 is an internal operating system as Android, which can install the applications via USB flash drive storage, SD card or Internet.

How to Switch to DSM365

  • Press the MENU button on either the rear panel control or remote control to show the OSD.
  • Use the navigation arrows to select and adjust the Input Source.
    [Input Source → Main → DSM365]

DynaScan DS491LT5 Professional Screen - About DSM365

ITEM DESCRIPTION
APPS

www.dynascandisplay.com
Copyright © DynaScan Technology, Inc.
All Rights Reserved.
DS491LT5 User Manual

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

DynaScan User Manuals

Related Manuals