DynaScan DW551DR4-1 55 Inch Dual Sided High Brightness Display User Manual

June 14, 2024
DynaScan

DW551DR4-1
USER MANUAL
55″ Dual-Sided High Brightness Display

DW551DR4-1 55 Inch Dual Sided High Brightness Display

DynaScan DW551DR4-1 55 Inch Dual Sided High Brightness
Display

Please read this manual carefully before operating the product and keep it for future reference. The use of diagrarns and illustrations in the manuat are for reference only, the actual product may differ.
FOR MORE INFOMATION
For more information about DynaScan, vist our site at www.dynascandisplay.com.
Copyright © DynaScan Technology Inc. All rights reserved. All specifications and descriptions are subject to change without notice. Reproduction without permission is prohibited.

Material Contents Declaration

Part Name Hazardous Substances
Lead Mercury
Polybrominated Biphenyls Polybromodiphenyl Ethers
Pb Hg
PCBA O
CHASSIS O
ACCESSORY O
PACKAGE O

“O” indicates that the level of the specified chemical substance is less than the threshold level specified in the standards of SJ/T-11363-2006 and EU 2011/65/EC.
“?” indicates that the level of the specified chemical substance exceeds the threshold level specified in the standards of SJ/T-11363-2006 and EU 2011/65/EC.

Recycling and Energy Information

DynaScan is firmly committed to its environmental protection efforts and we believe that reducing our products’ impact on the environment is of the utmost importance. We are dedicated to meet the latest environmental protection regulations.
Energy usage

Mode Energy Consumption
Normal Max. 380W
Standby < 1W

Disposal
Do not dispose of electrical appliances as unsorted municipal waste, use separate collection facilities. Contact your local government for information regarding the collection systems available. If electrical appliances are disposed of in landfills or dumps, hazardous substances can leak into the groundwater and get into the food chain, damaging your health and well-being. When replacing old appliances with new one, the retailer is legally obligated to take back your old appliances for disposal at least for free of charge. The terms HDMI and HDMI High-Definition Multimedia Interface, and the HDMI Logo are trademarks or registered trademarks of HDMI Licensing Administrator, Inc.

Declaration of Conformity

FCC
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two  conditions: (1) this device may not cause harmful interference, and (2) this device must accept anyinterference received, including interference that may cause undesired operation.
RF exposure warning
To comply with FCC RF exposure compliance requirements, a separation distance of at least 20 cm must be maintained between the antenna of this device and all persons.
This Transmitter must not be co-located or operating in conjunction with any other antenna or transmitter
FEDERAL COMMUNICATIONS COMMISSION INTERFERENCE STATEMENT
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
CAUTION:
Any changes or modifications not expressly approved by the grantee of this device could void the user’s authority to operate the equipment.
Manufacturer Name DynaScan Technology Corp.
Manufacturer Address 6F, No. 88 Wenmao Rd., Guishan Dist, Taoyuan City 333001,Taiwan
**** This device complies with Directive 2014/53/EU issued by the Commission of the European Community.

Article 3.1(a)
IEC 62368-1:2018
IEC 62368-1:2014
EN 62368-1:2017+A11:2017 Article 3.2
ETSI EN 300 328 v2.2.2
ETSI EN 301 893 v2.1.1EN I
EC 62311 (2020)| Article 3.1

EN 55032:2015+A1:2020
EN IEC 61000-3-2:2019+A1:2021 EN 61000-3-3:2013+A1:2019
EN 55035:2017+A11:2020 EN 301 489-1 v2.2.3
EN 301 489-17 v3.2.4

---|---

Safety Precautions

CAUTION

  • Do not install near flammable material or any heat sources.
  • Do not defeat the safety purpose of the grounding-type plug.
  • Do not disassemble the display to avoid electrical shock or burn.
  • Normal operating condition considers installation at an altitude below 2000m; some abnormalities may be experienced when installed at an altitude above 2000m.

WARNING
Please power off the LCD and the video source before plugging in the DP or HDMI cable.
Please installed the display in well-ventilated place, do not install in a confined space.
Suitable for mounting on concrete or other non-combustible surface only.
If it gives off smoke, strange smell, or unusual noise, or when it gets too hot to touch, immediately unplug the display and contact the dealer.
Clean only with soft, dry cloth but not use chemical liquids, and unplug while cleaning.
Do not use extreme force or any sharp or pointed objects to touch the display.
Do not drop or allow any object to fall to the display.
Do not operate the display with wet hands to avoid electric shock.
Do not discard this product with general household waste. Please be sure to comply with the local waste regulations.
This device uses, generates and radiated radio frequency energy. The radio frequency energy produced by this device is well below the maximum exposure allows by Federal Communications Commission (FCC).
When a stationary or fixed image is displayed on the screen for a long time, the image may be permanently imprinted on the screen. This phenomenon is known as image burn-in and is not covered by the manufacturer’s warranty.
In order to avoid burn-in, avoid prolonged display of static or fixed images on the screen.
Power supply cord must not be attached to the building surface, nor run through walls, ceilings, floors and similar openings in the building structure.
Power cord shall be connected to a socket-outlet with earthing connection.

Important Safety Information

  • Disassembling the LCD is strictly prohibited. Opening the cover may expose the user to electric shock or other hazards. Please contact DynaScan certified service professionals for all maintenance requirements.
  • Do not allow any liquid to enter the LCD. Also avoid placing the LCD close to water sources.
  • Do not place heavy objects on the power cord. A damaged power cord might cause electric shock or fire.
  • Do not bend, twist, or damage the power cord.
  • The power cord must comply with the local safety regulations.
  • Do not damage or modify the prongs/pins and the ground contact on the power cord plug.
  • Do not place the LCD on an unleveled surface or an unstable vehicle. The LCD could fall over and cause substantial damage.
  • Do not cover the vents and/or the heat sink.
  • Do not install the LCD beside radiators or other heat sources. The installation site should have sufficient ventilation so the heat generated by the LCD can be dissipated.
  • Do not use the Signage in a hot, humid, dusty, or fumy environment.
  • Handle the LCD with care. Save the packaging materials for transport later.
  • Clean the LCD backside at least once a month for dust and other particles.

Unplug the LCD immediately and contact a DynaScan certified service professional as soon as possible when any of the following situations occurs:

  • Damaged power cord or power plug.
  • If liquid or foreign object has entered the LCD.
  • If the LCD has been exposed to rain or water.
  • If the LCD has been dropped or the casing has become damaged.
  • If any structural damage such as cracks or unnatural vibration is found.
  • If the LCD cannot be operated following the steps outlined in this manual.
  • If the LCD emits smoke or other odors, or generates strange noises.

Operating Suggestions

  •  Avoid displaying a stationary image for a long period of time in order to prevent image sticking.

Cleaning the Panel

  • Use a soft, lint-free cloth to gently wipe the dust off from the screen panel.
  • Do not use any hard material to wipe the panel.
  • Do not poke the panel with your hand or any sharp object (such as a pen or a nail) or exert excessive pressure on the panel to prevent any damage.
  • Do not use any cleaning solutions on the panel as it might cause discoloration.

Cleaning the Casing

  • Unplug the power cord.
  • Gently wipe the casing with a soft cloth.

Attention

  • Do not use any of the following solutions to clean the casing as they may damage the paint and cause it to crack or peel: benzene solution, alkaline solution, alcohol-based cleaning solution, glass cleaner, wax, polisher, or detergent.

‘Stability Hazard’ or equivalent wording;
‘The monitor set may fall, causing serious personal injury or death’ or equivalent text;
The following or equivalent text:
To prevent injury, this monitor set must be securely attached to the floor/wall in accordance with the nstallation instructions.

Getting Started

Contents
Confirm that the accessories below are shipped along with the display. If any item is missing, please contact your dealer. The color and shape of the accessories may vary with the products.

  • DW551DR4-1 Professional LCD.
  • Remote Control x 1 pc.
  • Batteries (1.5V / AAA) x2 pcs.
  • Power cable x1 pc.
  • Quick Start Guide x1 pc.
  • ESK302 x2 pcs.

Attention: Please use the following table to check whether the included power cord is suitable for your region. If the power cord does not match your region, please contact your local supplier. Please use matching AC socket in order to meet your local safety regulations.   DynaScan DW551DR4-1 55 Inch
Dual Sided High Brightness Display - Contents

Installing and Replacing Remote Control Batteries

  1. Open the battery compartment cover.
  2. Insert 2 new AAA batteries.
  3. Close the battery compartment cover.

Warning:

  • Incorrect usage of batteries may cause leakage or explosion.
  • Pay attention to the polarity when installing the batteries.
  • Do not mix different types of batteries or new and used batteries. Doing so may shorten the battery life or cause leakage.
  • Remove or replace the batteries when they are empty in order to prevent acid leaking in the battery compartment.
  • Do not touch the leaked substance from the batteries in case of a battery leakage. Doing so may hurt human skin.

Note: If the remote control is not going to be used for a long time, we recommend removing the batteries from the remote control.

Installation

The LCD has been designed with two ways installation, which suitable for (1) Stand and (2) Ceiling Mount applications. Please note that the display must be properly installed onto the stand (DynaScan optional kit) or well-connected with the hanging kit (DynaScan optional kit), details please refer to the display installation guide. Incorrect installation may cause injury or damage the equipment. Product warranty does not cover the damage caused by improper installation and DynaScan shall not be held
responsible in such incident. If you attempt to install the LCD on a different way, such as hanging from the ceiling with your customized hanging kit or your own platform/ enclosure; please contact DynaScan directly for more assistance. Please follow the local regulations for safety handling and display installation, this equipment is intended to be installed by qualified service personnel.
(1) Stand

Model| Screw Location| Screw Specification| Screw Length|

Number

---|---|---|---|---
DW551DR4-1| A| 31.4 1088.9
31.4
1148.9
31.4 1208.9| M6| 7mm is required| 12
B| 31.4
63.9
31.4 123.9
31.4
183.9

DynaScan DW551DR4-1 55 Inch Dual Sided High Brightness Display -
Installation

  1. Two mounting holes can be found from top and bottom sides of the display (Portrait mode), which  are reserved for wall, ceiling or stand mounting use.
  2. When the connection kit insert into the mounting hole, each length side of the display has six screw holes which can be used for fasten.

Orientation

  • DW551DR4-1 provides 3 different screen orientations for various environment applications. Portrait Flip, Portrait and Landscape mode can be distinguished by the corresponding position of I/O port in the figures below.

DynaScan DW551DR4-1 55 Inch Dual Sided High Brightness Display -
Orientation Installation Location

  • Do not install in a location with strong vibrations or dusty.
  •  Do not install near the building’s main electric panel.
  • Ensure the LCD is secured in such a manner that it cannot be easily removed by the general public.
  • Leave clearance around the outer edge of the LCD from other objects to ensure proper ventilation.

DynaScan DW551DR4-1 55 Inch Dual Sided High Brightness Display -
Installation Location

Maintenance

  • Inspect the fasteners regularly for signs of loosening or deformation. Please perform appropriate corrective measures when a problem is identified. Neglecting the problem may worsen the situation.
  • Increase the inspection frequency on areas where previous maintenance had occurred to ensure the problems do not occur again.

Connecting to a Power Source
Using the power cable provided, plug it in the power inlet which shown in the diagram below.
Connect the power cable to a 100-240 volt, 50 / 60Hz AC power outlet.
** Insert the plug completely into the socket. A loose power connection may cause damage to the display and/or lead to a fire hazard.DynaScan DW551DR4-1
55 Inch Dual Sided High Brightness Display - Connecting to a Power
Source Connecting an External Video Source
** Turn OFF the power of both LCD and external video device. Using the DP cable (or HDMI cable, DVI cable), insert one end into the DP-IN (or HDMI-IN, DVI-IN) which shown in the diagram below.
Connect the other end of the DP cable (or HDMI cable, DVI cable) to the DP output (or HDMI output, DVI output) of the video source. Refer to your video device’s manual for additional information. DynaScan DW551DR4-1 55 Inch Dual
Sided High Brightness Display - Connecting an External Video
Source

Input / Output Terminals
A. AC (IN): Connect the supplied power cord to the wall outlet.
B. Power Switch: Press to switch the main power on/off.
C. Audio (OUT): Connect the audio signal output from Audio IN jack to an external AV device.
D. RJ-45 1 (IN): RJ45 network input connection.
E. HDMI 1 (IN): Connect the HDMI output of a PC or an AV device via a HDMI cable.
F. RS-232 (IN): RS232C network input connection for remote control from PC.
G. USB 2.0 port 1: Support for USB flash drive storage, mouse and keyboard.
H. Extension Connector: Extension Connector for optional IR Extension sensor kit (ESK302).
I. Thermal: Extension Connector for optional Extension thermal kit (ETK302).
*USB 2.0 port: A standardized port to connect a variety of devices like mouse, keyboard,DynaScan DW551DR4-1 55 Inch Dual Sided High Brightness Display - Output Terminals

Operating Instructions

Powering On/Off the Display
To turn on/off the display. Press the power switch on as shown in the diagram below.DynaScan DW551DR4-1 55 Inch Dual Sided High Brightness Display -
Powering On Off the Display NOTE: The remote control only works when the power switch is ON.
Using the Remote Control
Connection using an External Sensor Kit (ESK302)
Connect the ESK302 cable to the mini USB port, and aim the remote at the IR receiver as shown below.DynaScan DW551DR4-1 55 Inch Dual Sided High
Brightness Display - Remote Control Sensor Kit
The operating range of the remote control is 2.5 meters (8 feet). DynaScan
DW551DR4-1 55 Inch Dual Sided High Brightness Display - Sensor
KitNOTE: Ambient light may affect the performance of the remote control. Avoid fluorescent or neon lights in the vicinity.DynaScan DW551DR4-1 55 Inch Dual Sided High
Brightness Display - Remote Control 1*Color and shape may vary by model.

ITEM|

DESCRIPTION

---|---
❶| POWER| Power On / Off
❷| MENU| OSD On / Off
❸| UP| Move the cursor up or change the setting of selected item.
❹| LEFT| Exit the current selection.
❺| RIGHT| Select the highlighted item.
❻| DOWN| Move the cursor down or change the setting of selected item.
❼| OK| Enter (for DSM365 only)
❽| BACK| Return to the last page. (for DSM365 only)

Press the MENU button on the remote control to show the OSD. Use the navigation arrows to select and adjust the menu items.
*The change of each setting can only enable when you press “LEFT” (refer to p.18) to back to the last menu layer.
1. Input SourceDynaScan DW551DR4-1 55 Inch Dual Sided High Brightness
Display - Input Source

ITEM 1 ITEM 2 DEFAULT DESCRIPTION
Input Source Main HDMI Set the Main input to display.
Failover 1 SDM Set the Failover 1 input to display.
Failover 2 DSM365 Set the Failover 2 input to display.
Failback OFF Set the time (hour),when the Input Source is failover , it will

redetection the Main Source per few hour.
Command Detection| Off| Only effective in Main input source.
If the display didn’t get both of commend and the input signal, it will change to Failover1 input.

2. Picture

DynaScan DW551DR4-1 55 Inch Dual Sided High Brightness Display - Input
Source 1

ITEM 1| ITEM 2| DEFAULT|

DESCRIPTION

---|---|---|---
Picture| Color Temperature| USER| Adjusts the color temperature to preset or user determined values. (User, D55, D65, D93, Balanced)
Red| 100| Adjust the red light level. Range 0 – 100. Not
e
: The feature is only supported on User2 mode.
Green| 100| Adjust the green light level. Range 0 – 100.
Note : The feature is only supported onUser2 mode.
Blue| 100| Adjust the blue light level. Range 0 – 100.
Note : The feature is only supported on User2 mode.
Contrast| 50| Adjust the contrast level. Range 0 – 100.
Gamma| Native| Adjusts the Gamma value. (Native, 2.2, 2.4  and sGamma)
Black Level| Limited| Selects the black level to adjust the screen gray scale. “Limited” for video source uses 16 to 235 levels for R/G/B, such as HDMI. “RGB Full” for video source uses all levels from 0 to 255 levels.
“Auto” is for detecting the video source to determine its value is applicable for “Limited” or “RGB Full”.

3. Brightness

DynaScan DW551DR4-1 55 Inch Dual Sided High Brightness Display - Input
Source 2

ITEM 1| ITEM 2| DEFAULT|

DESCRIPTION

---|---|---|---
Brightness| Auto Brightness| Fixed| Brightness Setting :Fixed:screen brightness remains at one level. Timer:Screen brightness is determined by the time of day. Auto:Screen brightness is determined by an extension sensor kit (ESK). Mix:Mix Timer & Auto Mode,Autosensor time screen brightness determined by an extension sensor kit (ESK); fixed time by timer. By Light Value:Screen brightness determined by ambient light values, up to 4 levels. By Time:Screen brightness determined by scheduled values, up to 4 levels.
Backlight Level| 100|

4. Time![DynaScan DW551DR4-1 55 Inch Dual Sided High Brightness Display

ITEM 1

| ITEM 2| DEFAULT|

DESCRIPTION

---|---|---|---
Time| Region| |
Time Zone| | Set the Time Zone.
Set Date & Time| | Set the mode.
Current Time| | Set the clock.
Note : The internal clock will continue to function when the power is turned off.
Current Date| | Set the date.
Day of Week| | Set the day of week. (Monday to Sunday)

5. ScheduleDynaScan DW551DR4-1 55 Inch Dual Sided High Brightness
Display - setting 1

ITEM 1

| ITEM 2| DEFAULT|

DESCRIPTION

---|---|---|---
Schedule| Power ON|OFF Time| OFF| Automatic power on / off schedule function.

6.AdvancedDynaScan DW551DR4-1 55 Inch Dual Sided High Brightness
Display - setting 3

ITEM 1| ITEM 2| DEFAULT|

DESCRIPTION

---|---|---|---
Advanced| Display Mode| Auto| Change the Menu orientation. The Menu can be displayed in either LANDSCAPE or PORTRAIT mode.
Screen Protection| OFF| Turn on / off image burn-in protection.
Set image burn-in protection interval. Range 0 –100 minutes.
IR Control| On| Enable/disable the remote control for Menu.
Note : When disabled, the remote control function can be enabled again from the control panel on the display or through the DynaScan “Display Manager” application.
Power Restore Behavior| Power On| Choose to use the AC back status function. Power On: Display booting up when the power back after an outage.
Standby: Display keeps soft-off status when the power back after an outage.
Memory: Display will back to the last state when the
Auto Out Volume| 50| Set volume. Range 100 – 0.
Source Info| ON| Enable/disable the Video Source Information.
RS232 CMD Compatible| OFF| RS232 Command compatibility between the current and last generation* model.
* _ last generation model** : DS371BT4_ 、 DS491LT4DS552LT4-1DS552LT4-MDS552LT5DS552LT6-1DS552LT7DS551DR4DI551ST2DW551LR5DO552LR4DO551LR4DO552LR4-MDI651ST2DP652ST2DP652LT5
Schedule Reboot| OFF| Enable/disable the Schedule Reboot, And set the Time.
OSD Password Protection| OFF| Turn On: Create Password > Confirm Password > Password Protection On
Turn Off: Enter Password > Password Protection Off
Export & Import Settings| | Export or Import OSD Setting by USB.
Reset Default Settings| | Restore all settings to default.
Note : It does not modify CURRENT TIME, POWER ON TIME and POWER OFF TIME.

7. InformationDynaScan DW551DR4-1 55 Inch Dual Sided High Brightness
Display - setting 4

ITEM 1| ITEM 2| DEFAULT|

DESCRIPTION

---|---|---|---
Information| Resolution| | Input resolution
MCB Version| | The MCB version.
FW Version| | The F/W version.
Fan Status| | Good: Fan under normal working conditions NG: A malfunction of the fan system.
**** Thermal Kit Temp.| | The Extension Thermal Kit (ETK302) is for ambient temperature monitoring.

Some functions may not be available for all models.

Specifications

MODEL|

DW551DR4- 1

---|---
PANEL| LCD Panel Size| 54.64 inches
Native Resolution| 1920 x 1080
Brightness| 1000 cd/m² (Typ.) / 3000 cd/m² (Typ.)
Contrast Ratio| 3,000:1
Response Time| 8 ms (Typ.)
Viewing Angle| 178°/ 178°
Life Time| 100,000 hrs (Typ.)
Panel Surface| AR 1.5%, 2H
POWER| Power Supply| Internal
Rated Voltage| 100 – 240V, 50 / 60Hz
Power On Mode| 380W
Power Saving Mode| < 1W
MECHANICAL SPECS| Bezel Width (T/B/L/R)| 29.5/29.5/29.5/29.5 mm
Cabinet Color| Black
Monitor Dimension (LxHxD)| 1272.8 x 743.3 x 62.7 mm
Monitor Weight| 43 kg
Orientation| Landscape / Portrait
USER INTERFACE| OSD Language| English
ENVIRONMENT| Operation Temperature| 0°C ~ 45°C
Storage Temperature| -20°C ~ 60°C
Humidity| 10%~80% RH Non-Condensing
I/O Ports| HDMI| IN 2
RS-232| IN
1
Audio| OUT 1
USB port| IN
2
RJ-45| IN 1
Extension Connector (Mini USB)| IN
1 (ESK only)
External temp. sensor| IN *1 (ETK only)
Fuse| | 5A

Design and specifications are subject to change without notice.

Input Mode

Active Resolution|

Refresh Rate

---|---

H Pixels

|

V Lines

640| 480| 60 Hz
720| 480| 60 Hz
800| 600| 60 Hz
960| 600| 60 Hz
1024| 768| 60 Hz
1280| 720| 60 Hz
1280| 768| 60 Hz
1280| 960| 60 Hz
1280| 1024| 60 Hz
1366| 768| 60 Hz
1400| 1050| 60 Hz
1440| 900| 60 Hz
1600| 1200| 60 Hz
1680| 1050| 60 Hz
1920| 720| 60 Hz
1920| 1080| 60 Hz

Pin Assignments

RS-232 Input

PIN No.

|

NAME

---|---
01| Connected to 7&8
02| TXD
03| RXD
04| Connected to 6
05| GND
06| Connected to 4
07| Connected to 1&8
08| Connected to 1&7
09| NC

DynaScan DW551DR4-1 55 Inch Dual Sided High Brightness Display - Pin
Assignments

Troubleshooting

ISSUE|

RECOMMENDED SOLUTION

---|---
No image is displayed.| Check whether the cable is completely plugged in.
Check whether the main switch is in the ON position, and the power cord is completely plugged in.
Check whether the image source’s resolution is set as the supported format (refer to section “Input Mode”, p.26).
Check whether the cable is damaged or bent excessively.
Nothing happens when switching the main switch on.| Unplug the power cord from the socket and plug it in again after a few seconds to reset the Signage.
Note: Unplugging the power cord will not change the settings.
Image is unstable.| Check whether the cable is completely plugged in.
The remote control does not work.| Check whether there are batteries in the remote control.
Check the batteries for freshness, polarity, etc.
Check whether the remote is in the operation range.
Bright light may interfere with the remote control.
Please avoid using the remote control near special fluorescent lights or neon lights.
Auto on/off does not work or does not function properly.| Check whether the TIMER setting in the menu is set to “OFF”.
Check whether the “Power On Time” and “Power Off Time” settings are set correctly.
Cannot control the display remotely via RS-232.| Check whether the RS-232 cable is connected properly.

If you are still having trouble with your DynaScan DS² Professional LCD, contact your dealer or DynaScan directly for more assistance.

About DSM365

DSM365 is an internal operating system as Android, which can install the applications via USB flash  drive storage, SD card or Internet.
How to Switch to DSM365

  • Press the MENU button on either the rear panel control or remote control to show the OSD.
  • Use the navigation arrows to select and adjust the Input Source.  [Input Source → Main → DSM365]

DynaScan DW551DR4-1 55 Inch Dual Sided High Brightness Display -
Switch

ITEM

|

DESCRIPTION

---|---
❶| APPS| Show the Installed APPS.

About SDM

Install SDM on the display
*Note: SDM must comply with Rated Power DC 12V 45W (Max 50W) and IEC 62368-1 Standard.

  1. Loosen screws and remove the SDM cover from the display.DynaScan DW551DR4-1 55 Inch Dual Sided High Brightness Display - SDM cover
  2. Insert the SDM module into the display and fasten screws. Make sure the SDM properly installed to avoid causing the devise destructionDynaScan DW551DR4-1 55 Inch Dual Sided High Brightness Display - SDM cover 1

Switch to SDM

  • Press the MENU button on either the rear panel control or remote control to show the OSD.
  • Use the navigation arrows to select and adjust the Input Source.
    [ Input Source →Main →SDM ]DynaScan DW551DR4-1 55 Inch Dual Sided High
Brightness Display - setting 6

www.dynascandisplay.com
Copyright © DynaScan Technology, Inc. All Rights Reserved.
DW551DR4-1 User Manual

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

DynaScan User Manuals

Related Manuals