DELTA SLM50 Ceiling Wall Ventilation Fan Instruction Manual

June 17, 2024
Delta

INSTALLATION AND OPERATING INSTRUCTIONS
CEILING/WALL VENTILATION FAN
READ AND SAVE THESE INSTRUCTIONS

GENERAL SAFETY INFORMATION

  1. Make sure that the electric service supply voltage is AC 120V, 60Hz.
  2. Follow all local electrical and safety codes, as well as the National Electrical Code (NEC) and the Occupational Safety and Health Act (OSH Act).
  3. Always disconnect the power source before workingon or near the ventilating fan, motor or junction box
  4. Protect the power cord from sharp edges, oil, greasehot surfaces, chemicals or other objects.
  5. Do not kink the power cord.
  6. Do not install the unit where ducts are configured asshown in Fig. A.
  7. Provide suction parts with proper ventilation.
  8. This unit is UL listed for use over a bathtub or shower when installed in a GFCI protected branch circuit.
  9. These ventilating fans are intended for residential usage only.

WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:

  1. Use this unit only in the manner intended by the manufacturer. If you have any questions, contact the manufacturer.

  2. Before servicing or cleaning the unit, switch the power off at service panel and lock the service disconnecting means to prevent the power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a  prominent warning device, such as a tag, to the service panel.

  3. Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction.

  4. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent backdrafting.
    Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating Refrigeration and Air Conditioning Engineers (ASHRAE) and  local code authorities. 5. When cutting or drilling into walls or ceilings, do not damage electrical wiring and other hidden utilities.

  5. Do not install this ventilating fan where air temperature may exceed 40°C (104°F).

  6. Ducted ventilating fans must always be vented to the outdoors.

  7. If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application and be connected to a GFCI (Ground Fault Circuit Interrupter) – protected branch circuit.

  8. These models are UL listed for tub and shower enclosures.

  9. Do not use this unit with any other solid-state control device. Solid-state controls may cause harmonic distortion, which can cause a motor humming noise.

  10. NEVER place a switch where it can be reached from a tub or shower.

  11. Not to be installed in a ceiling thermally insulated to a value greater than R40. (This is required for installation in Canada only)

CAUTION

  1. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.
  2. Not for use in cooking area. (Fig. B)
  3. This product must be properly grounded.

DELTA SLM50 Ceiling Wall Ventilation Fan - Figure 2

SUPPLIED ACCESSORIES

DELTA SLM50 Ceiling Wall Ventilation Fan - Figure 3

DIMENSIONS

DELTA SLM50 Ceiling Wall Ventilation Fan - Figure 5

SPECIFICATIONS

Model No.| Voltage
(V)| Frequency
(Hz)| Power
(W)| Air Flow
@ 0.1SM)P
(  CF| Weight
(lb.)| Note
---|---|---|---|---|---|---
SLM50| 120| 60| 6.| 50| 4.| Single
Speed
SLM70| 120| 60| 13.| 70| 4.| Single
Speed

Note: Design and specifications subject to change without notice.

OPERATION

  1. Single Speed Model: SLM50
    Single speed control mode: Turn the power switch on/off to operate ON or OFF – the LED indicator will be green.

  2. Single Speed Model: SLM70
    Single speed control mode: Turn the power switch on/off to operate ON or OFF – the LED indicator will be green.

MAINTENANCE WARNING:

Disconnect the power source before working on the unit.
Routine maintenance must be done every year.
CAUTION:

  1. Never use gasoline, benzene, thinner or any other such chemicals for cleaning the ventilating fan.
  2. Do not allow water to enter the motor.
  3. Do not soak resin parts in water over 60°C (140°F).

CLEANING

  1. Pull down the spring to remove the grille.
  2. Wash and clean the grille. (Use non-abrasive kitchen detergent, wipe dry with a new cloth.)
  3. Remove dust and dirt from the ventilating fan using a vacuum cleaner.
  4. Using a cloth dampened with kitchen detergent, remove any dirt from ventilating fan. Wipe dry with a new cloth.
  5. Replace the grille.

INSTALLATIONS

Install with wood frame

Model No. SLM50 SLM70
Install Dim.(Inch) 7.5X7.25 7.5X7.25
  1. Remove the motor plate from the housing by removing the three screws. (Fig. C)
  2. Remove the wiring cover from the housing by pulling straight out. Choose a hole and use a slotted screwdriver to remove it. (Fig. D)
  3. Follow all local electrical and safety codes. NEVER place a switch where it can be reached from a tub or shower. Connect wires as shown in wiring diagrams. (Fig. E)
  4. Using wire nuts, connect the house power cable to the ventilating fan wires. 14 AWG (2.1 mm 2) is the smallest conductor that shall be used for branch-circuit wiring. (Fig. F)
  5. Insert the duct into the duct connector and tape all ductwork connections to make them secure and airtight. Install the duct with a gradient 1°~2° to the outside. (Fig. G)
  6. New installation prior to finishing the ceiling or wall: Insert the fan between joists. Make sure the fan body is level and perpendicular with the joist. (Fig. H)
  7. Replacement installation: After making electrical and ductwork connections (see steps 2~5), nail the housing in place. Drive nails through the housing where indicated by arrows. (Fig. I)
  8. New installation in an existing ceiling or wall: Bend tabs outward 90°(Use a screw driver if desired) and position housing so that tabs rest against the bottom edge of the joists (or front of stud). Nail the housing to the joist or stud using four nails to ensure a solid, quiet installation. Ceiling installations: Tabs on the opposite side of the housing can be bent outward to rest on top of 1/2″ ceiling material and provide extra stability. (Fig. J)
  9. Plug in the motor and lock the fan body back by using three screws. (Fig. C)
  10. Squeeze the grille springs together and insert the springs into the slots in the motor plate. Push the grille up against the ceiling or wall. When the power is on, check for abnormal vibrations or sounds. Insert the mounting springs into the slots and mount  the grille to the body. (Fig. K)

DELTA SLM50 Ceiling Wall Ventilation Fan - Figure 6DELTA SLM50 Ceiling Wall Ventilation Fan - Figure
7

WARRANTY

DELTA ELECTRONICS THREE YEAR LIMITED WARRANTY
Delta Electronics Inc. (“Delta Electronics”) warrants to the original consumer purchaser in the USA that the Breez ventilation fan products will be free from defects in material or workmanship. This warranty is limited to three (3) years from the original date of  purchase.
Limitations and Exclusions

  1. During the warranty period, a replacement for any defective product will be supplied free of charge for installation by the consumer. The warranty provided herein does not cover charges for labor or other costs incurred in the troubleshooting, repair,  removal, and installation service.
  2. All returns of defective parts or products must include the product model number, and must be made through an authorized Delta Electronics distributor. Authorized returns must be shipped prepaid. Repaired or replacement products will be shipped by  Delta Electronics F.O.B. shipping point.
  3. Delta Electronics shall not be liable for any indirect, incidental, consequential, punitive, or special damages arising out of or in connection with products’ use or performance, regardless of the form of action whether in contract, tort (including negligence),  strict product liability or otherwise.
  4. This warranty does not extend to fluorescent lamp starters and tubes.
  5. The warranty does not cover if user does not comply with manufacturer’s installation manual.
  6. To qualify for warranty service, you must notify Delta Electronics at the address or telephone number below.
  7. Delta Electronics shall have no liability to the original owner-user with respect to any defect caused by abuse, misuse, neglect, improper transportation or storage, improper testing, improper installation, improper operation, improper use, improper  maintenance, improper repair, improper alteration, improper modification, tampering or accident of products or parts thereof, or unusual deterioration or degradation of products or parts thereof due to a physical environment beyond the requirements of  products’ specifications.

Address: 4405 Cushing Parkway, Fremont, CA 94538
US Toll Free Number: 1-888-979-9889

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Delta User Manuals

Related Manuals