HANYOUNG nux PAN20-TN PAN Series Area Sensor Instruction Manual

June 10, 2024
HANYOUNG NUX

Hangyoung nux-logo

HANYOUNG nux PAN20-TN PAN Series Area Sensor

Product Information: Area Sensor PAN Series

The Area Sensor PAN Series is a product manufactured by Hanyoung Nux. It is used to detect the presence or absence of an object in a specific area. The sensor operates through a through-beam sensing method using an IR (860nm) light source. It is available in two models, PAN20 and PAN40, with varying optical axis pitches and number of optical axis. The sensor has NPN or PNP control output options.

Specifications:

Type| Model| Sensing Distance| Sensing Object| Optical Axis Pitch| Light Source| Power Voltage| Current Consumption| Control Output
---|---|---|---|---|---|---|---|---
Through beam| PAN20-TN| 7m| 20mm| 8-48 (depending on model)| IR (860nm)| Max. 170V| Max. 100mA| NPN or PNP open collector
Through beam| PAN40-TN| 7m| 40mm| 4-24 (depending on model)| IR (860nm)| Max. 170V| Max. 100mA| NPN or PNP open collector

The sensor has a response time of maximum 15ms and is insulated
with a minimum resistance of 20M ohms (500VDC mega standard). It is
also equipped with noise immunity, dielectric strength, vibration
resistance, and shock resistance features for added protection.

Product Usage Instructions:

Before using the Area Sensor PAN Series, it is important to read the safety information carefully and use the product correctly. The alerts declared in the manual are classified into Danger, Warning, and Caution according to their importance. Please follow these alerts to prevent any product malfunction.

  1. Connect the sensor to a power source using the power supply (SMPS) and noise-eliminating condenser.
  2. Select the appropriate model and control output option for your application.
  3. Install the sensor in the desired location with a clear line of sight to the area to be detected.
  4. Set the operation mode using the M/S MODE switch for the transmitter and D/L MODE switch for the receiver.
  5. Check the operation LED and protection circuit for proper functioning.
  6. Ensure that ambient illumination is within the specified range of maximum 10,000 lux for sunlight and 3,000 lux for incandescent lamp.
  7. During operation, maintain an ambient temperature of -10 ~ +55 ℃ and humidity of 35 ~ 85% R.H. without condensation or icing.

PAN series

INSTRUCTION MANUAL

Thank you for purchasing Hanyoung Nux products. Please read the instruction manual carefully before using this product, and use the product correctly. Also, please keep this instruction manual where you can see it any time.

HANYOUNGNUXCO.,LTD

28, Gillaroo 71beon-gil, Michuholgu, Incheon, Korea
TEL : +82-32-876-4697 http://www.hynux.com

Safety information

Please read the safety information carefully before use, and use the product correctly. The alerts declared in the manual are classified into Danger, Warning and Caution according to their importance.

DANGER
Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury.

WARNING
Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.

CAUTION
Indicates a potentially hazardous situation which, if not avoided, may result in minor injury or property damage.

DANGER

The input/output terminals are subject to electric shock risk. Never let the input/output terminals come in contact with your body or conductive substances.

WARNING

  • The contents of this manual are subject to change without prior notice.
  • To prevent defection or malfunction of this product, supply proper power voltage in accordance with the rating.
  • Do not use the product at where subject to flammable or explosive gas.
  • Remove this product while the power is off. Otherwise, it may cause malfunction or electric shock.
  • Due to the danger of electric shock, use this product installed onto a panel while an electric current is applied.
  • To avoid electric shock, use this product installed on the panel.
  • This product is not for press safety sensors.
  • This product does not have control of the disaster prevention and accident prevention.
  • Hanyoung Nux shall not be liable for a damage and for a failure.

CAUTION

  • The contents of this manual are subject to change without prior notification.
  • If you use the product with methods other than specified by the manufacturer, there may be bodily injuries or property damages.
  • Do not decompose, modify, revise or repair this product. This may be a cause of malfunction, electric shock or fire.
  • Make sure that there is no damage or abnormality of the product during delivery.
  • Do not use this product at any place with a large inductive noise or occurring static electricity or magnetic noise.
  • Do not use this product at any place with possible thermal accumulation from direct sunlight or heat radiation.
  • When the product gets wet, the inspection must be done to avoid electric leakage or fire.
  • Make sure that the unused wire insulated.
  • Make sure to wire with correct polarity of terminals.
  • For the continuous and safe use of this product, the periodical maintenance is recommended.
  • Make wiring as short as possible, wire is recommended with its demission 0.5 ㎟ or more and maximum 25m.
  • Avoid continuously switching the power source On and Off.
  • Use a dry cloth to wipe off the substance when cleaning the lens or cases. Never use thinner or organic solvents.
  • Do not use this product where exposed to dust, vibration or impact.
  • Before inserting power source, make sure that the circuit wiring is properly connected.
  • In the case of wiring loaded inductors such as DC Relay and others to output, use diode, visitor and others to prevent surge.
  • To avoid malfunction caused by noise, do not put high voltage or power line with sensor wire in a same conduit
  • Prevent strong disturbance light such as sunlight and others which directly enter into the directional angle of the sensor by putting a glare shield.
  • When using the Switching Power Supply as the power source, earth the Frame Ground (F.G) terminal and be sure to connect the noise-eliminating condenser between 0 V and F.G.

HANYOUNG-nux-PAN20-TN-PAN-Series-Area-Sensor-01 

If you do not follow the contents described in the safety information then it is possible to be a cause of the product’s malfunction so please follow them.

Feature

  • Minimum beam pitch 20 ㎜, maximum beam pitch 40 ㎜.
  • Providing various detection range (140㎜ – 940㎜).
  • Mutual interference protection when installed in parallel (Max 2 sets).
  • Dark On/ Light ON operation selectable according to applications.
  • Easy to check and maintenance by operation display and Error indicator.

Suffix code

 | Code|
---|---|---
PAN Model| □| -□| □| □| Area Sensor                         Content
Optical axis pitch| 20|  |  |  | 20 ㎜
40|  |  |  | 40 ㎜
Sensing method| T|  |  | Through Beam
Number of optical axis|  |  | Number of optical axis (Please refer to table below)
Control output| N| NPN open collector
P| PNP open collector
PAN20| 8, 12, 16, 20, 24, 28, 32, 36, 40, 44, 48
---|---
PAN40| 4, 6, 8, 10, 12, 14, 16, 18, 20, 22, 24

Specification

 |
---|---
Model|  | NPN| PAN20-T□N                   Through|  | PAN40-T□N
PNP| PAN20-T□P| PAN40-T□P
Sensing distance|  | 7 m|
Sensing object|  |
Optical axis pitch| 20 ㎜                        IR (86|  | 40 ㎜
Light source|
Power voltage| 12 – 24 VDC ±10% Ripple(p-p)10% max
Current consumption| Max. 170 ㎃| Max. 100 ㎃
|
|
Operation LED| LED), E1 display(Red LED), E2 display(Blue LED)
Protection circuit| Power reverse connecMtiountuparlointetcetrifoenre, nOcuetpretvsahtoiornt-cfuirnccutiitoonver-current protection,
Response Time| Max. 15 ㎳
Insulation resistance| Min. 20 ㏁ (500 VDC mega standard)
Noise immunity| Square wave noise by noise simulator (pulse width 1 ㎲) ±240 V
Dielectric strength| 1,000 VAC (50/60 Hz 1min)
Vibration resistance| 10 – 55 ㎐, double amplitude: 1.5 ㎜, X·Y·Z in each direction for 2 hours
Shock resistance| 500㎨ , X·Y·Z each direction 3 times
Ambient illumination| Sunlight : Max. 10,000 Lux, Incandescent lamp : Max. 3,000 Lux
Ambient temperature| During operation : -10 ~ +55 ℃, During storage : -25 ~ +70 ℃ (Without condensation or icing)
Ambient humidity| 35 ~ 85 % R.H. (Without condensation)
Degree of protection| IP65 (IEC standard)
Approval|
Connection method| (Code length : 200 ㎜, RNeulamybceornonfewctiroersty: p4Pe, Dimension : Ø5.5 ㎜)
Material| Case| Aluminum
front cover| Acryl
lens| Acryl

Production formation

Series| Model| Detection| Seisntsainocneg| Nputimcablearxoefs| Detecting| Current(tComnasux)motion| Detectable object
---|---|---|---|---|---|---|---

PAN20

| PAN20-T8|

ThBreoaumgh

|

7 m

| 8 EA| 140 ㎜| 70 ㎃|

Oopajeqcute Øab32ov㎜e

PAN20-T12| 12 EA| 220 ㎜| 80 ㎃
PAN20-T16| 16 EA| 300 ㎜| 90 ㎃
PAN20-T20| 20 EA| 380 ㎜| 100 ㎃
PAN20-T24| 24 EA| 460 ㎜| 110 ㎃
PAN20-T28| 28 EA| 540 ㎜| 120 ㎃
PAN20-T32| 32 EA| 620 ㎜| 130 ㎃
PAN20-T36| 36 EA| 700 ㎜| 140 ㎃
PAN20-T40| 40 EA| 780 ㎜| 150 ㎃
PAN20-T44| 44 EA| 860 ㎜| 160 ㎃
PAN20-T48| 48 EA| 940 ㎜| 170 ㎃

PAN40

| PAN40-T4| 4 EA| 120 ㎜| 50 ㎃|

Oopajeqcute Øab52ov㎜e

PAN40-T6| 6 EA| 200 ㎜| 55 ㎃
PAN40-T8| 8 EA| 280 ㎜| 60 ㎃
PAN40-T10| 10 EA| 360 ㎜| 65 ㎃
PAN40-T12| 12 EA| 440 ㎜| 70 ㎃
PAN40-T14| 14 EA| 520 ㎜| 75 ㎃
PAN40-T16| 16 EA| 600 ㎜| 80 ㎃
PAN40-T18| 18 EA| 680 ㎜| 85 ㎃
PAN40-T20| 20 EA| 760 ㎜| 90 ㎃
PAN40-T22| 22 EA| 840 ㎜| 95 ㎃
PAN40-T24| 24 EA| 920 ㎜| 100 ㎃

Output Circuit

  • NPN Open Collector Output (N TYPE)
  • PNP Open Collector Output (P TYPE)

HANYOUNG-nux-PAN20-TN-PAN-Series-Area-Sensor-02

Dimension

PAN20 series

HANYOUNG-nux-PAN20-TN-PAN-Series-Area-Sensor-03

PAN40 series

HANYOUNG-nux-PAN20-TN-PAN-Series-Area-Sensor-04

Type A B C D1 D2 E1 E2
PAN20-T8 PAN40-T4 227 214.2 197 7 3 140
PAN20-T12 PAN40-T6 307 294.2 277 11 5 220
PAN20-T16 PAN40-T8 387 374.2 357 15 7 300
PAN20-T20 PAN40-T10 467 454.2 437 19 9 380
PAN20-T24 PAN40-T12 547 534.2 517 23 11 460
PAN20-T28 PAN40-T14 627 614.2 597 27 13 540
PAN20-T32 PAN40-T16 707 694.2 677 31 15 620
PAN20-T36 PAN40-T18 787 774.2 757 35 17 700
PAN20-T40 PAN40-T20 867 854.2 837 39 19 780
PAN20-T44 PAN40-T22 947 934.2 917 43 21 860
PAN20-T48 PAN40-T24 1027 1014.2 997 47 23 940

Indicator & Wiring classification

HANYOUNG-nux-PAN20-TN-PAN-Series-Area-Sensor-05

Operation LED classification

LED indicator Transmitter

Red

Green

| L.OFF when operation the MASTER / L.ON when operating the SLAVE

Power indicator

 |

LED indicator Receiver
Red Operation LED
Green L.ON stability indicator
Red L.OFF with the disconnection or break of cluck (sync signal)/reset signal

wire
Blue| L.OFF with the appearance of disturbance light such as mercury lamp, luminescent light and etc.

Wiring and connecting classification

PIN NO. Wiring color Transmitter

1

2

| Brown

Orange

| Power (12 – 24 VDC)

Sync wire

3| Blue| GND
 |  |
4| Purple| M/S

PIN NO. Wiring color Receiver

1

2

| Brown

Orange

| Power (12 – 24 VDC)

Sync wire

 |  |
3| Blue| GND
4| Black| Output

Operation chart

HANYOUNG-nux-PAN20-TN-PAN-Series-Area-Sensor-06

  • Green LED on the Transmitter is power indication.
  • The E1 indicator on the receiver (red led) is turn off when the sync line is shorted.
  • The E2 indicator on the receiver (blue LED) is turn off when there is a disturbance light such as sunlight,
  • fluorescent light, etc. (It may malfunction when the E2 indicator is turn off so please be careful)
  • In the case of Dark On, the operation indicator and control output operate in the reverse direction of Light ON.

MASTER / SLAVE Connection diagram

When two sensors are used close together, set them as shown below. Connect sensor A and sensor B according to the connection method in <Image 1>.

HANYOUNG-nux-PAN20-TN-PAN-Series-Area-Sensor-07

  • Open the connector cover at the bottom of the Transmitter (use the flat drive) and make the operation mode conversion
    switch as shown in Image 2 below. Set the Transmitter of sensor A to M (Master) and the Transmitter of sensor B to S (Slave)

  • Default = M (Master)

HANYOUNG-nux-PAN20-TN-PAN-Series-Area-Sensor-08

  • When using two sets of sensors together, wire them so that they do not become the master operation mode or the slave operation mode for both of them.
  •  Do not connect the sync lines of sensor A and sensor B to each other.
  •  Check the M / S indicator of the Transmitter after turning on the power.
    • Transmitter A (Master operation mode): M/S indicator is Turn off,
    • Transmitter B (Slave operation mode): M/S indicator is Turn on.

Operation Mode

  • Open the connector cover at the bottom of the Transmitter (use the flat drive), and use the operation mode switch to select the mode that meets the operating conditions.
  • Default mode: L (Light On) operation mode
  • L : LIGHT ON / D : DARK ON

Mounting and optical axis adjustment

  • After checking the connection status, turn on the power and check that the power indicator (green) of the Transmitter is turn on.
  • Move the Transmitter up, down, left, and right so that the light stability indicator (green) of the Receiver turns on.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

HANYOUNG NUX User Manuals

Related Manuals