FRIEDRICH CCW15B10B Room Air Conditioner Installation Guide

June 17, 2024
FRIEDRICH

FRIEDRICH-LOGO

FRIEDRICH CCW15B10B Room Air Conditioner

FRIEDRICH-CCW15B10B-Room-Air-Conditioner-PRO

RECOGNIZE THIS SYMBOL AS AN INDICATION OF IMPORTANT SAFETY INFORMATION!

WARNING THESE INSTRUCTIONS ARE INTENDED AS AN AID TO QUALIFIED SERVICE PERSONNEL FOR PROPER INSTALLATION, ADJUSTMENT AND OPERATION OF THIS UNIT. READ THESE INSTRUCTIONS THOROUGHLY BEFORE ATTEMPTING INSTALLATION OR OPERATION. FAILURE TO FOLLOW THESE INSTRUCTIONS MAY RESULT IN IMPROPER INSTALLATION, ADJUSTMENT, SERVICE OR MAINTENANCE, POSSIBLY RESULTING IN FIRE, ELECTRICAL SHOCK, CARBON MONOXIDE POISONING, EXPLOSION, PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.
WARNING PROPOSITION 65 WARNING: THIS PRODUCT CONTAINS CHEMICALS KNOWN TO THE STATE OF CALIFORNIA TO CAUSE CANCER, BIRTH DEFECTS OR OTHER REPRODUCTIVE HARM.

DO NOT DESTROY THIS MANUAL. PLEASE READ IT CAREFULLY AND KEEP IN A SAFE PLACE FOR FUTURE REFERENCE BY A SERVICEMAN.

CAUTION: Do Not Operate Equipment During Active Stages Of Construction To ensure proper operation, Friedrich requires that all equipment is not operated during active construction phases. This includes active stages of completing framing, drywalling, spackling, sanding, painting, flooring, and molding in the equipment’s designated conditioning space. The use of this equipment during construction could result in premature failure of the components and/or system and violates our standard warranty guidelines. The operation of newly installed equipment during construction will accelerate the commencement and/or termination of the warranty period.

Register your Air Conditioner
Model information can be found on the name plate. Please complete and mail the owner registration card furnished with this product, or register online at www.friedrich.com.

IMPORTANT SAFETY AND GENERAL INFORMATION

Introduction
This booklet contains the installation and operating instructions for your Air Conditioning unit. Some precautions should be taken to ensure proper operation. Improper installation can result in unsatisfactory operation or dangerous conditions.
Read this booklet and any instructions packaged with separate equipment required to make up the system before installation. Give this booklet to the owner and explain its provisions. The owner should retain this booklet for future reference.

Safety Warnings

WARNING: The manufacturer’s warranty does not cover any damage or defect to the air conditioner caused by the attachment or use of any components, accessories or devices (other than those authorized by the manufacturer) into, onto or in conjunction with the air conditioner. You should be aware that the use of unauthorized components, accessories or devices may adversely affect the operation of the air conditioner and may also endanger life and property. The manufacturer disclaims any responsibility for such loss or injury resulting from the use of such unauthorized components, accessories or devices.

WARNING: Electrical Shock Hazard
Disconnect all power to the unit before starting maintenance. All electrical connections and wiring MUST be installed by a qualified electrician and conform to the National Code and all local codes which have jurisdiction. Failure to do so can result in property damage, severe electrical shock or death.

WARNING: Read Installation Manual
Please read this manual thoroughly before equipment installation or operation. It is the installer’s responsibility to properly apply and install the equipment. Installation must be in conformance with the NFPA 70-2023 national electric code or current edition, International Mechanic Code 2021 or current edition, and any other local or national codes.

WARNING: Safety First
Do not remove, disable, or bypass this unit’s safety devices. Doing so may cause fire, injuries, or death.

WARNING

  • RISK OF FIRE OR EXPLOSION
  • FLAMMABLE REFRIGERANT USED
  • REPAIRS MAY ONLY BE PERFORMED BY TRAINED PERSONNEL
  • CONSULT THE SERVICE MANUAL BEFORE ATTEMPTING REPAIRS. ALL SAFETY PRECAUTIONS MUST BE FOLLOWED
  • DO NOT PUNCTURE TUBING
  • DISPOSE OF UNIT PROPERLY BY FEDERAL OR LOCAL REGULATIONS
  • ONLY USE A2L APPROVED SERVICE EQUIPMENT

Warning For Using R32 Refrigerant
For R32 refrigerant models:

  1. Appliance shall be installed, operated and stored in a room with a floor area larger than 43 sq ft.
  2. Appliance shall not be installed in an unventilated space, if that space is smaller than 43 sq ft.
  3. Compliance with national gas regulations shall be observed.
  4. Keep ventilation openings clear of obstruction.
  5. The appliance shall be stored so as to prevent mechanical damage from occurring.
  6. A warning that the appliance shall be stored in a well-ventilated area where the room size corresponds to the room area as specified for operation.
  7. Any person who is involved with working on or opening a refrigerant system must be certified for refrigerant handling as required by local, state, and federal regulations.
  8. Servicing shall only be performed as recommended by the equipment manufacturer. Maintenance and repair requiring the assistance of other skilled personnel shall be carried out under the supervision of the person competent in the use of flammable refrigerants.
  9. Please follow the instruction carefully to handle, install, clear, and service the air conditioner to avoid any damage or hazard. Flammable Refrigerant R32 is used within air conditioner. When maintaining or disposing the air conditioner, the refrigerant (R32) shall be recovered properly, and shall not be discharged to air directly.
  10. No any open fire or device like a switch which may generate spark/arcing shall be around the air conditioner to avoid causing ignition of the flammable refrigerant used.
  11. Please follow the instruction carefully to store or maintain the air conditioner to prevent mechanical damage from occurring.
  12. Flammable refrigerant R32 is used in air conditioner. Please follow the instruction carefully to avoid any hazard.
  13. For specific information on the type of gas and the amount of refrigerant used, refer to the model nameplate on the unit.

CAUTION: Risk of fire/flammable materials (Required for R32 units only)
WARNING: low burning velocity material (For R32 models apply to IEC60335-2-40:2018)

Note about Fluorinated Gases

  1. Fluorinated greenhouse gases are contained in hermetically sealed equipment. For specific information on the type, the amount and the Co2 equivalent in tonnes of the fluorinated greenhouse gas(on some models), please refer to the relevant label on the unit itself.
  2. Installation, service, maintenance and repair of this unit must be performed by a certified technician.
  3. Product uninstallation and recycling must be performed by a certified technician.

For Household Use Only Read And Save These Instructions

  1. Transport of equipment containing flammable refrigerants: See transport regulations.

  2. Marking of equipment using signs: See local regulations.

  3. Disposal of equipment using flammable refrigerants: See national regulations.

  4. Storage of equipment/appliances: The storage of equipment should be by the manufacturer’s instructions.

  5. Storage of packed (unsold) equipment: Storage package protection should be constructed such that mechanical damage to the equipment inside the package will not cause a leak of the refrigerant charge. The maximum number of pieces of equipment permitted to be stored together will be determined by local regulations.

  6. Information on servicing:

  7. Checks to the area:
    Before beginning work on systems containing flammable refrigerants, safety checks are necessary to ensure that the risk of ignition is minimized. For repair to the refrigerating system, the following precautions shall be complied with before conducting work on the system.

  8. Work procedure:
    Work shall be undertaken under a controlled procedure to minimize the risk of a flammable gas or vapor being present while the work is being performed.

  9. General work area:
    All maintenance staff and others working in the local area shall be instructed on the nature of work being carried out. Work in confined spaces shall be avoided. The area around the workspace shall be sectioned off. Ensure that the conditions within the area have been made safe by control of flammable material.

  10. Checking for presence of refrigerant:
    The area shall be checked with an appropriate refrigerant detector before and during work, to ensure the technician is aware of potentially flammable atmospheres. Ensure that the leak detection equipment being used is suitable for use with flammable refrigerants, i.e. non-sparking, adequately sealed or intrinsically safe.

  11. Presence of fire extinguisher:
    If any hot work is to be conducted on the refrigeration equipment or any associated parts, appropriate fire extinguishing equipment shall be available to hand. Have a dry powder or CO2 fire extinguisher adjacent to the charging area.

  12. No ignition sources:
    No person carrying out work about a refrigeration system that involves exposing any pipe work that contains or has contained flammable refrigerant shall use any sources of ignition in such a manner that it may lead to the risk of fire or explosion. All possible ignition sources, including cigarette smoking, should be kept sufficiently far away from the site of installation, repairing, removing and disposal, during which flammable refrigerant can possibly be released to the surrounding space. Before work taking place, the area around the equipment is to be surveyed to make sure that there are no flammable hazards or ignition risks. No Smoking signs shall be displayed.

  13. Ventilated area:
    Ensure that the area is in the open or that it is adequately ventilated before breaking into the system or conducting any hot work. A degree of ventilation shall continue during the period that the work is carried out. The ventilation should safely disperse any released refrigerant and preferably expel it externally into the atmosphere.
    Checks to the refrigeration equipment:
    Where electrical components are being changed, they shall be fit for the purpose and to the correct specification. At all times the manufacturer’s maintenance and service guidelines shall be followed. If in doubt consult the manufacturer’s technical department for assistance. The following checks shall be applied to installations using flammable refrigerants:

  *  **a.** The charge size is by the room size within which the refrigerant-containing parts are installed;
  *  **b.** The ventilation machinery and outlets are operating adequately and are not obstructed;
  *  **c.** If an indirect refrigerating circuit is being used, the secondary circuit shall be checked for the presence of refrigerant; Marking to the equipment continues to be visible and legible. Markings and signs that are illegible shall  e corrected;
  *  **d.** Refrigeration pipe or components are installed in a position where they are unlikely to be exposed to any substance which may corrode refrigerant-containing components, unless the components are constructed of materials which are inherently resistant to being corroded or are suitably protected against being so corroded.
8.  **Checks to electrical devices:**  

Repair and maintenance to electrical components shall include initial safety checks and component inspection procedures. If a fault exists that could compromise safety, then no electrical supply shall be connected to the circuit until it is satisfactorily dealt with. If the fault cannot be corrected immediately but it is necessary to continue operation, an adequate temporary solution shall be used. This shall be reported to the owner of the equipment so all parties are advised. Initial safety checks shall include:

  *  **a.** That capacitors are discharged: this shall be done safely to avoid possibility of sparking;
  *  **b.** That there no live electrical components and wiring are exposed while charging, recovering or purging the system;
  *  **c.** That there is continuity of earth bonding.
  1. Repair to intrinsically safe components:
    Do not apply any permanent inductive or capacitance loads to the circuit without ensuring that this will not exceed the permissible voltage and current permitted for the equipment in use. Intrinsically safe components are the only types that can be worked on while live in the presence of a flammable atmosphere. The test apparatus shall be at the correct rating. Replace components only with parts specified by the manufacturer. Other parts may result in the ignition of refrigerant in the atmosphere from a leak.

  2. Cabling:
    Check that cabling will not be subject to wear, corrosion, excessive pressure, vibration, sharp edges or any other adverse environmental effects. The check shall also take into account the effects of aging or continual vibration from sources such as compressors or fans.

  3. Detection of flammable refrigerants
    Under no circumstances shall potential sources of ignition be used in the searching for or detection of refrigerant leaks. A halide torch (or any other detector using a naked flame) shall not be used.

  4. Leak detection methods:
    The following leak detection methods are deemed acceptable for systems containing flammable refrigerants. Electronic leak detectors shall be used to detect flammable refrigerants, but the sensitivity may not be adequate, or may need re-calibration. (Detection equipment shall be calibrated in a refrigerant-free area.) Ensure that the detector is not a potential source of ignition and is suitable for the refrigerant used. Leak detection equipment shall be set at a percentage of the LFL of the refrigerant and shall be calibrated to the refrigerant employed and the appropriate percentage of gas (25 % maximum) is confirmed. Leak detection fluids are suitable for use with most refrigerants but the use of detergents containing chlorine shall be avoided as the chlorine may react with the refrigerant and corrode the copper pipe-work. If a leak is suspected, all naked flames shall be removed/extinguished. If a leakage of refrigerant is found which requires brazing, all of the refrigerant shall be recovered from the system, or isolated (using shut off valves) in a part of the system remote from the leak. Oxygen-free nitrogen (OFN) shall then be purged through the system both before and during the brazing process.

  5. Removal and evacuation
    When breaking into the refrigerant circuit to make repairs or for any other purpose conventional procedures shall be used. However, best practice must be followed since flammability is a consideration. The following procedure shall be adhered to: Remove refrigerant; Purge the circuit with inert gas; Evacuate; Purge again with inert gas; Open the circuit by cutting or brazing. The refrigerant charge shall be recovered into the correct recovery cylinders. The system shall be flushed with OFN to render the unit safe. This process may need to be repeated several times. Compressed air or oxygen shall not be used for this task. Flushing shall be achieved by breaking the vacuum in the system with OFN and continuing to fill until the working pressure is achieved, then venting to atmosphere, and finally pulling down to a vacuum. This process shall be repeated until no refrigerant is within the system. When the final OFN charge is used, the system shall be vented down to atmospheric pressure to enable work to take place. This operation is vital if brazing operations on the pipe work are to take place. Ensure that the outlet for the vacuum pump is not close to any ignition sources and there is ventilation available.

  6. Charging procedures:
    In addition to conventional charging procedures, the following requirements shall be followed. Ensure that contamination of different refrigerants does not occur when using charging equipment. Hoses or lines shall be as short as possible to minimize the amount of refrigerant contained in them. Cylinders shall be kept upright. Ensure that the refrigeration system is earthed before charging the system with refrigerant. Label the system when charging is complete (if not already). Extreme care shall be taken not to overfill the refrigeration system. Before recharging the system it shall be pressure tested with OFN. The system shall be leak tested on completion of charging but before commissioning. A follow-up leak test shall be carried out before leaving the site.

  7. Decommissioning:
    Before carrying out this procedure, the technician must be completely familiar with the equipment and all its detail. It is recommended good practice that all refrigerants are recovered safely. Before the task being carried out, an oil and refrigerant sample shall be taken in case analysis is required before re-use of reclaimed refrigerant. Electrical power must be available before the task is commenced.

    • a. Become familiar with the equipment and its operation.
    • b. Isolate system electrically.
    • c. Before attempting the procedure ensure that: Mechanical handling equipment is available, if required, for handling refrigerant cylinders; All personal protective equipment is available and being used correctly; The recovery process is supervised at all times by a competent person; Recovery equipment and cylinders conform to the appropriate standards.
    • d. Pump down refrigerant system, if possible.
    • e. If a vacuum is not possible, make a manifold so that refrigerant can be removed from various parts of the system.
    • f. Make sure that cylinder is situated on the scales before recovery takes place.
    • g. Start the recovery machine and operate by the manufacturer’s instructions.
    • h. Do not overfill cylinders. (No more than 80 % volume liquid charge).
    • i. Do not exceed the maximum working pressure of the cylinder, even temporarily.
    • j. When the cylinders have been filled correctly and the process completed, make sure that the cylinders and the equipment are removed from site promptly and all isolation valves on the equipment are closed off.
    • k. Recovered refrigerant shall not be charged into another refrigeration system unless it has been cleaned and checked.
  8. Labelling:
    Equipment shall be labelled stating that it has been de-commissioned and emptied of refrigerant. The label shall be dated and signed. Ensure that there are labels on the equipment stating the equipment contains flammable refrigerant.

  9. Recovery:
    When removing refrigerant from a system, either for servicing
    or decommissioning, it is recommended good practice that all refrigerants are removed safely. When transferring refrigerant into cylinders, ensure that only appropriate refrigerant recovery cylinders are employed. Ensure that the correct number of cylinders for holding the total system charge is available. All cylinders to be used are designated for the recovered refrigerant and labeled for that refrigerant (i.e. special cylinders for the recovery of refrigerant).
    Cylinders shall be complete with pressure relief valve and associated shut-off valves in good working order. Empty recovery cylinders are evacuated and, if possible, cooled before recovery occurs. The recovery equipment shall be in good working order with a set of instructions concerning the equipment that is at hand and shall be suitable for the recovery of flammable refrigerants. In addition, a set of calibrated weighing scales shall be available and in good working order. Hoses shall be complete with leak-free disconnect couplings and in good condition. Before using the recovery machine, check that it is in satisfactory working order, has been properly maintained and that any associated electrical components are sealed to prevent ignition in the event of a refrigerant release. Consult the manufacturer if in doubt. The recovered refrigerant shall be returned to the refrigerant supplier in the correct recovery cylinder, and the relevant Waste Transfer Note arranged. Do not mix refrigerants in recovery units and especially not in cylinders. If compressors or compressor oils are to be removed, ensure that they have been evacuated to an acceptable level to make certain that flammable refrigerant does not remain within the lubricant. The evacuation process shall be carried out before returning the compressor to the suppliers. Only electric heating to the compressor body shall be employed to accelerate this process. When oil is drained from a system, it shall be carried out safely.
    NOTE: Check the appliance regularly and refer to TROUBLESHOOTING or contact our customer support if it shows any of the following signs:

    • Power cord or plug is damaged.
    • Loud noise, unusual smell or excessive heat.

Importance of a Quality Installation
Optimal system performance and longevity depend upon a quality and proper installation. Failure to properly install this unit could result in undesirable operation and subsequent faults and potential failures. Carefully follow all guidelines listed in the manual and industry best practices. Conform to all local code requirements. Contact your local technical representative with any questions or concerns. Upon receiving the unit, inspect it for any damage from shipment. Claims for damage, either shipping or concealed, should be filed immediately with the shipping company. IMPORTANT: Check the unit model number, Cooling size, electrical characteristics, and accessories to determine if they are correct.
WARNING: Check the unit power cord and make sure the cord is protected from wear, corrosion, excessive pressure, vibration, sharp edges, or any other adverse environmental effects. It is recommended that the cord is checked for any potential damage when filter maintenance is performed. If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
WARNING: If the unit appears damaged,or if a refrigerant leak is suspected, do not install. Contact a licenced repair person to perform a leak check on the unit.
WARNING: Under no circumstances shall potential sources of ignition be used in the searching for or detection of refrigerant leaks. A halide torch (or any other detector using a naked flame) shall not be used. The following leak detection methods are deemed acceptable for all refrigerant systems. Electronic leak detectors may be used to detect refrigerant leaks but, in the case of FLAMMABLE REFRIGERANTS, the sensitivity may not be adequate, or may need re-calibration. (Detection equipment shall be calibrated in a refrigerant-free area.) Ensure that the detector is not a potential source of ignition and is suitable for the refrigerant used. Leak detection equipment shall be set at a percentage of the LFL.
WARNING: Service of this product (aside from filter maintenance) shall only be performed by trained service personnel. This includes: Opening of any ventilated Any tubing or refrigerant circuit work Opening of any sealed components Enclosures beyond the hinged door for filter cleaning Scan this QR code to be linked to the Friedrich professional support page where you can locate the Service Manual.

Product Inspection / Packing List
Upon receiving the unit, inspect it for any damage from shipment. Claims for damage, either shipping or concealed, should be filed immediately with the shipping company. IMPORTANT: Check the unit model number, Cooling size, electrical characteristics, and accessories to determine if they are correct .FRIEDRICH-CCW15B10B-Room-Air-Conditioner- \(2\)

SPECIFICATIONS

Dimensions

INSTALLATION OF THE UNIT

Pre-Installation Checkpoints
Before attempting any installation, carefully consider the following points:

  • Clearances and provision for servicing. Install this unit in accordance with local and national standards. Any and all work must be done by authorized personnel.
  • IMPORTANT: Before you begin the actual installation of your air conditioner, check your local electrical codes and the information below. Your air conditioner must be connected to a power source with the same alternating current (A.C.) voltage and amperage as marked on the name plate located on the chassis. Only A.C. can be used. Direct Current (D.C.) cannot be used.
  • CIRCUIT PROTECTION – Use on single outlet circuit only. An overloaded circuit will invariably cause malfunction or failure of an air conditioner; therefore, it is necessary that the electrical protection is adequate. Due to momentary high current demand when the air conditioner starts, use a “TIME DELAY” fuse or a HACR type circuit breaker. Consult your dealer or power company if in doubt.
  • Refer to the electrical name plate located on the air conditioner chassis (see Table E.1 to determine the correct fuse or circuit breaker amperage for your model.
  • The power cord has a plug with a grounding prong and a matching receptacle is required.

Tools Required

WARNING- Electrical Shock Hazard
Make sure your electrical receptacle has the same configuration as your air conditioner’s plug. If different, consult a Licensed Electrician. Do not use plug adapters. Do not use an extension cord. Do not remove ground prong. Always plug into a grounded 3 prong outlet. Failure to follow these instructions can result in death, fire, or electrical shock.

  1. Power Drill
  2. 1/8 Drill Bit
  3. Gloves
  4. Carpenters Level
  5. 2 Phillips Screw Driver

  6. Putty Knife or (wood stir stick)

Choosing a Location Installation Clearances
Improper installation of the Air Conditioner can cause poor performance and premature wear of the unit. Ensure that the unit is installed with proper clearances as described below. Ensure no obstructions or enclosures are within clearances limits to allow for proper airflow. Ensure no open flames, or surfaces that will exceed 1000 degrees Fahrenheit are within clearances limits.

Clearances
WARNING -Refigeration System Under High Pressure

  • Do not puncture, heat, expose to flame or incinerate.
  • Only certified refrigeration technicians should service this equipment.
  • R410A and R32 systems operate at higher pressures than R22 equipment.
  • Appropriate safe service and handling practices must be used.
  • Only use gauge sets designed for use with R410A or R32.
  • Do not use standard R22 gauge sets.

Top and Bottom of Unit – One (1) foot
Sides of Unit – One (1) foot
Front of Unit – Three (3) feet
Rear of Unit – Three (3) feet

WARNING – Fire Hazard
A2L refrigerant is classified as mildly flammable. Do not install unit next open flame sources, or surfaces that will exceed 1200 degrees fahrenheit.

**Window Installation

**

CAUTION – Moving Parts Hazard

  • Do not operate unit out of sleeve or with front grille removed.
  • Do not place hands in blower or fan blade areas.
  • Failure to do so can result in serious injury.

CAUTION – Excessive Weight Hazard
Use two or more people when installing your air conditioner. Failure to do so can result in back or other injury.

Window preparation

  1. This air conditioner is designed to be installed in a standard double-hung window Refer to Figure C.4.2 for dimensions.
  2. The air conditioner can be installed without the accordion panels fit in a narrow window opening.
  3. The lower sash ( the lower part of the window that moves up and down) must allow for vertical clearance when open. Refer to Figure C.4.2 for dimensions.
  4. All supporting parts must be secured to firm wood, masonry, or metal.
  5. The electrical outlet must be within reach of the power cord.

TOOLS NEEDED:

  • Phillips Screw Driver
  • Drill (If pilot holes are needed)

NOTE: Save the product packaging and installation instructions for future reference. Store the air conditioner in the product box when not in use for an extended period of time.

How to Install
NOTE: This is necessary for proper condensed water utilization and drainage. If you are not using the Side Panels for any reason, this pitch to the rear muse be maintained!
Remove the air conditioner from the box and place on a hard flat surface, as floor, a bench or a table. There is a Left and Right Window Filler Panel – be sure to use the proper panel for each side. When installed the flange for securing the panel in place to the window sill will be facing into the room.

REMOVE FRONT PANEL AND CHASSIS

  1. Pull down the front panel and remove the filter.
  2. Lift the front panel upwards to remove and place to the side.
  3. Locate the four faceplate screws and remove. These screws will need to be re-installed prior to mounting the air conditioner.
  4. After removing the screws, gently pull away the faceplate from the air conditioner cabinet.
  5. Remove the control panel screw and WI-FI module screw from the front panel.
  6. Remove the six screws from the cabinet. There two screws on the top, left, and right.
  7. Hold the cabinet while pulling on the base handle to carefully remove the unit. Do not pull or lift near the top of the unit.

Top Angle Rail and Side Bracket Installation
The top rail must be assembled prior to installing the air conditioner in the window
Tools Needed: Phillips Screw Driver

Attaching the Top Rail to the Air Conditioner

  1. Remove the air conditioner from the box and place on a hard flat surface.
  2. Remove top rail from the bottom of the packaging material as shown in FIG. A
  3. Secure the top rail to the unit with the 5/16″ Screws as shown in FIG. B
  4. Slide the “I” section of the window panel into the side bracket of the cabinet (FIG.9a ). Do this for both sides
  5. Insert top and bottom legs of window filler panel frame into channel in the top angle and bottom rail. Do both sides. Install side retainer to cabinet as shown. (FIG. 9b-10).

Placing the Cabinet Inside the Window

  1. Open the window and place the cabinet in the middle of the window sill.
  2. Make sure the bottom rail is seated over the window sill as shown below. Bring the window down temporarily behind the top angle rail to hold the cabinet in place. (It is suggested to keep a downward angle so accumulated rain water can drain out from the backside of the unit.)
  3. Fasten cabinet to window sill using two 5/8″ Round-Head screws. Pre-drill holes if needed. Add the bottom rail seal over the screws.FRIEDRICH-CCW15B10B-Room-Air-Conditioner- \(19\)

Install Support Brackets

  1. Hold each support bracket flush against the outside of the window sill. Tighten each bracket to the bottom of the cabinet as shown below. Mark the brackets at top lever of the window sill and then remove.
  2. Assemble the sill angle brackets to the support brackets at the marked position as shown above. Hand tighten, but not for any changes that may need to be made later during installation.
  3. Install the support brackets (with sill angle brackets attached) to the bottom of the cabinet as shown below.
  4. Tighten all 6 bolts securely.

Extend the Accordion Panels

  1. Carefully raise the window to expose the accordion panel and panel frame. Loosen the locking screws so the accordion panels slide easily.
  2. Extend each panel to completely fill the width of the window. Tighten the locking screws when the panels are fully extended.

Install the Window Lock and Sash Seal

  1. Trim the sash seal to fit the width of the window. Insert the sash seal into space between the upper and lower sashes.
  2. Attach the right angle sash lock as shown below.

Installing the Chassis into the Cabinet

  1. Team lift (two people) the air conditioner chassis and carefully slide it into the cabinet. Let the front of the air conditioner hang out approximately 6″.
  2. CAUTION: DO NOT PUSH ON THE CONTROLS OR FINNED COILS.
  3. Be sure the chassis is firmly seated in the back of the cabinet.
  4. Insert all screws removed during window installation and reattach the front face plate, front panel, and the air filter. Use the REMOVE CHASSIS instructions and figures 5-11 for reference.

Storm Window Requirements
A storm window frame will not allow the air conditioner to tilt properly which in turn will keep it from draining properly. To adjust for this, attach a board or a piece of wood to the sill. The board or piece of wood should have a depth of at least 1/2″. Make sure the board is approximately 1/2″ higher than the storm window frame. This will allow the air conditioner to tilt enough for proper drainage.FRIEDRICH-CCW15B10B-Room-Air-Conditioner-
\(26\)

Thru-The-Wall Installation Instructions – Optional

NOTE: Consult local building codes prior to installation and/or a qualified carpenter.

Select the Wall Location
This air conditioner has a slide-out chassis, so that it can be installed through an outside wall as specified below:
MAX WALL THICKNESS: 8″
IMPORTANT: The side louvers must never be blocked.
NOTE: All parts needed for Thru-The-Wall Installation are provided, except a wood frame, shims, and 10 wood screws (10-1″ long minimum). Select a wall surface that:

  1. Does not support major structural loads such as the frame construction at ends of windows, and under truss-bearing points, etc.
  2. Does not have plumbing or wiring inside.
  3. Is near existing electrical outlets, or where another outlet can or will be installed.
  4. Does not have objects blocking the air vents which limits cooling.
  5. Allows unblocked airflow from the rear and sides of the air conditioner.

Prepare the Wall

  1. Prepare the wall in frame construction (including brick and stucco veneer). Working from inside the room, find the wall stud that is nearest the center of the installation area.

  2. Cut a hole on each side of the center stud.

  3. Measure between the inside edges of every other stud as shown below.
    Carefully measure and cut an opening with the following dimensions depending on your model.

    • WIDTH “X” = inside model plus twice the thickness of the framing material used.
    • HEIGHT “Y” = inside model height plus twice the thickness of framing material used.FRIEDRICH-CCW15B10B-Room-Air-Conditioner- \(28\)
  4. Build a wooden frame with the INSIDE dimensions of your model listed above (Measure twice). The frame depth should be the same as the wall thickness. Fill in extra space from the opening to the studs with wood spacers as shown below.

  5. Nail the spacers to the studs. They should be flush with the dry wall.
    NOTE: If wall thickness is 8-1/2″ or more, add aluminum flashing over the bottom of the frame opening to assure water is unable to enter the area between the inner and outer wall.

Prepare and Install the Cabinet

  1. Slide the chassis from the cabinet. Refer back to the REMOVE CHASSIS instructions (Page 6 and 7) in the WINDOW MOUNTING SECTION.

  2. Place the cabinet into the opening with the bottom rail resting firmly on the bottom board of the wood frame.

  3. Position the cabinet so it is tilted properly for water removal as seen below.

  4. Secure the bottom rail to the wood frame with two large 1″ long wood screws as shown below.
    Refer to the SUPPORT BRACKET ASSEMBLY in the WINDOW MOUNTING section to assemble the support brackets. A wooden strip nailed to the outside wall should be used in conjunction with the angled sill support brackets.

  5. Screw or nail the cabinet to the wooden frame using shims if the frame is oversized, to eliminate possible noise. Remember to maintain proper slope for water elimination.

  6. Install the chassis into the cabinet by following the steps described in the WINDOW MOUNTING section.
    OPTIONAL: Caulking and installation of the trim on the interior wall may be done if desired. Caulk the openings around the top and sides of the cabinet and all sides of the wood sleeve to the opening.
    NOTE: See the WINDOW MOUNTING instructions for the bottom rail seal location.

MASONRY CONSTRUCTION

  1. Cut or build a wall opening in the masonry wall similar to the frame construction (refer to the THRU-THE-WALL installation for a wall thickness greater than 8 1/2″)..
  2. Secure the cabinet in place using masonry nails, or masonry anchor screws. Or, build a frame using the instructions found in the THRU-THE-WALL installation section.
  3. Make sure the masonry above the cabinet is supported well. Use the existing holes in the cabinet or additional drilled holes to fasten the cabinet at various positions. Make sure that the side louvers are clear of any obstructions.
  4. Install the exterior cabinet support brackets according to the SUPPORT BRACKET INSTALLATION instructions in the THRU-THE-WALL installation section. Caulk or flash with aluminum if needed. This will provide a tight seal around the top and sides of the cabinet.
  5. For a more aesthetically pleasing installation, apply wood trim molding around the sides of the cabinet without obstructing the side louvers.

ELECTRICAL

Electrical Safety Information
WARNING
– Electrical Shock Hazard

  • Make sure your electrical receptacle has the same configuration as your air conditioner’s plug. If different, consult a Licensed Electrician.
  • Do not use plug adapters.
  • Do not use an extension cord.
  • Do not remove ground prong.
  • Always plug into a grounded 3 prong outlet. Failure to follow these instructions can result in death, fire, or electrical shock.

Make sure the wiring is adequate for your unit. If you have fuses, they should be of the time delay type. Before you install or relocate this unit, be sure that the amperage rating of the circuit breaker or time delay fuse does not exceed the amp rating listed in Table 1. DO NOT use an extension cord. The cord provided will carry the proper amount of electrical power to the unit; an extension cord may not. Make sure that the receptacle is compatible with the air conditioner cord plug provided. Proper grounding must be maintained at all times. Two prong receptacles must be replaced with a grounded receptacle by a certified electrician. The grounded receptacle should meet all national and local codes and ordinances. You must use the three-prong plug furnished with the air conditioner. Under no circumstances should you remove the ground prong from the plug50.FRIEDRICH-CCW15B10B-Room-Air-Conditioner-
\(35\)

Testing the Power Cord
All Friedrich room air conditioners are shipped from the factory with a Leakage Current Detection Interrupter (LCDI) equipped power cord. The LCDI device on the end of the cord meets the UL and NEC requirements for cord connected air conditioners.
To test your power supply cord:

  1. Plug power supply cord into a grounded 3 prong outlet.
  2. Press RESET (see Figure E.2).
  3. Press TEST, listen for click; the RESET button trips and pops out.
  4. Press and release RESET (Listen for click; RESET button latches and remains in). The power cord is ready for use.

Once plugged in, the unit will operate normally without the need to reset the LCDI device. If the LCDI device fails to trip when tested or if the power supply cord is damaged, it must be replaced with a new power supply cord from the manufacturer.FRIEDRICH-CCW15B10B-Room-Air-Conditioner-
\(36\)

STARTUP AND OPERATION

Control Panel Operation
USING YOUR AIR CONDITIONER Electronic Control Panel & Remote Control
NOTE: This display always shows the room temperature in Fan Mode except when setting the Timer. FRIEDRICH-CCW15B10B-Room-Air-Conditioner-
\(37\)

Normal Operating Sounds

  • You may hear a pinging noise caused by water hitting the condenser on rainy days, or when the humidity is high. This design feature helps re­move moisture and improve efficiency.
  • You may hear the thermostat click when the com­pressor cycles on and off.
  • Water will collect in the base pan during rain or days of high humidity. The water may overflow and drip from the outside part of the unit.
  • The fan may run even when the compressor is not on.
  1. Digital Display: Without timer setting, the set temperature will be displayed. Time will be displayed under the timer setting.

  2. + and – Button: Use these buttons on the control panel and remote to increase or decrease the Set Temperature or Timer.
    Temperature range: 61″F~88″F or 16’C~31 ‘C.

  3. Button: Turn the air conditioner on and off.

  4. Mode Button: Press the mode button to cycle through the various modes: Cool, Dry, Fan and Auto, or Heat.

    • Cool Mode: The cooling function allows the air conditioner to cool the room and at the same time reduces air humidity. Press the MODE button to activate the cooling function. To optimize the function of the air conditioner, adjust the temperature and the speed by pressing the button indicated.

    • Dry Mode: This function reduces the humidity of the air to make the room more comfortable. Press MODE button to set the DRY mode. An automatic function of alternating cooling cycles and air fan is activated.

    • Fan Mode: The air conditioner works in only ventilation. Press MODE button to set the FAN mode.
      With pressing the FAN SPEED button the speed changes in the following sequence: Hi, Med and Lo in FAN mode.

    • Auto Mode: In AUTO mode the unit automatically chooses the fan speed and the mode of operation (COOL, HEAT, DRY or FAN). In this mode the temperature is set automatically according to the room temperature (tested by the temperature sensor which is incorporated in the indoor coil).

    • Heat Mode: The heating function allows the air conditioner to heat the room. Press the MODE button to activate the heating function. To optimize the function of the air conditioner, adjust the temperature and the speed by pressing the button indicated.

  5. Timer Button: Use these buttons on the control panel and remote to set the Timer.

    • Timer Off: The timed stop is programmed by pressing TIMER button. Set the rest time by pressing the button “+” or “-” until the rest time displayed is to your liking then press
      the TIMER button again.

    • Timer On: When the unit is off, press TIMER button at the first time, set the temperature with pressing the button “+” or “-” . Press TIMER button at the second time, set the rest time with pressing the button “+” or “-” . Press TIMER button at the third time, confirm the setting, then the rest time to next automatic switching-on could be read on the display of the machine. Note: It can be set to automatically turn off or on in 0.5-24 hours. Each press of the “+” “-” buttons will increase or decrease the timer. The Timer can be set in 0.5 hour increments below 10 hours and 1 hour increment for 10 hours or above. The SET light will turn on while setting.
      To cancel the set function, press the TIMER button again.

  6. Money Saver Button: When the unit is in Money Saver mode, the light will turn on. In Money Saver mode, the unit will turn off once the room is cooled to the user-set temperature. The unit will turn back on when the room temperature rises above the user-set temperature. Before the compressor starts, the fan motor will run for a while, then it will stop for a while, and will repeat to provide a much more comfortable feeling and save energy.

  7. Sleep Button: Press the SLEEP button, all of the display lights will turn off after a while, but the Sleep light is always on. In SLEEP mode, the air conditioner will automatically adjust the temperature and fan speed to make the room more comfortable during the night. The set temperature will automatically raise every 30-60 minutes, and at most change six times until the set temperature is 81 or 82°F. for cooling and 75 or 76°F for heating.

  8. Fan Speed Button: Press the FAN SPEED button to choose the fan speed options. You can choose Hi, Med, Lo or auto speed in COOL mode or HEAT mode and choose Hi, Med, Lo in FAN mode.

  9. Filter Button:
    When the Filter Check light is on, you can turn off the light by pressing the Filter Check button. After the fan motor works for 500 total hours, the Filter Check light will turn on to remind the user to clean the filter. When the Filter Check light is off, it is not necessary to press the Filter Check button.

  10. Directional Louvers: To direct the airflow, use the horizontal wheel to control the horizontal direction, and use the air deflectors to control the vertical direction.FRIEDRICH-CCW15B10B-Room-Air-Conditioner- \(39\)

Remote Control Operation

  1. Power: Turn the air conditioner on and off. This button will clear the TIMER setting.

  2. MODE: Press the button to select the mode of operation, AUTO, COOL, DRY, FAN ONLY, HEAT.
    Note: The HEAT mode is only for some heating models. If you do not need it, press the MODE button for more than 5 seconds to delete the HEAT function, and the COOL mode will be selected automatically. Press the MODE again for more than 5 seconds to add the HEAT function, and the HEAT mode will be selected automatically.

  3. + And -: Use these buttons to increase or decrease the setting Temperature or Timer. Setting temperature range: 61 ~88°F or 16 ~31°C .
    Note: After setting temperature with remote using the + and – buttons, both the remote display and the unit display will automatically turn off after a short time. This does not affect the unit operation.

  4. TURBO: When the remote is ON, press the button to activate the TURBO function, under AUTO/COOL/FAN ONLY mode. Press again to cancel the TURBO function, and the fan speed will change to pre-setting before.
    Note: °F and °C change: After inserting the batteries, in the off state within 3 minutes, press the TURBO button for more than 5 seconds to switch the Fahrenheit (°F) or Celsius (°C) degree display.

  5. DISPLAY: When the unit is ON, press the button, to switch off/on all lights or LED display. And this function will be canceled when changing mode.

  6. TIMER: Use the button to set the TIMER, or cancel the TIMER.

    • TIMER OFF: When the unit is ON, the timed OFF is programmed by pressing TIMER button, the remote will display 6 hours of pre-setting at first.
      Set the rest time by pressing the button or until the needed rest time display, then press TIMER button again to confirm.

    • TIMER ON: When the unit is OFF, the timed ON is programmed by pressing TIMER button, the remote will display 6 hours of pre-setting at first. Set the rest time by pressing the button or until the needed rest time display, then press TIMER button again to confirm. Later, the remote screen will keep display [TIMER] icon.
      Note: When TIMER ON, it cannot select Sleep mode, but can pre-set Mode, temperature, fan speed, ECO.

  7. SLEEP: Press the SLEEP button, all of the display lights will turn off after a while, but the Sleep light is always on. In SLEEP mode, the air conditioner will automatically adjust the tem-perature and fan speed to make the room more comfortable during the night. The set temperature will automatically raise every 30-60 minutes and at most change six times until the set temperature is 81 or 82°F. This function can be selected when COOL or HEAT mode.

  8. FAN SPEED: Press the FAN SPEED button to choose the fan speed options. You can choose Hi, Med, Lo or Auto speed in COOL or HEAT mode and choose Hi, Med, Lo in FAN mode. When DRY mode, it is only Low fan speed.

  9. MONEY SAVER: When the unit is in COOL mode, press the button to MONEY SAVER function. In MONEY SAVER mode, the unit will turn off once the room is cooled to the user set temperature. The unit will turn back on when the room temperature rises above the user set temperature. Before the compressor starts, the fan motor will run for 20 sec., then it will stop for 10 min., and will repeat to provide a much more comfortable feeling and save energy.

    • Battery size: AAA
      Note: Do not mix old and new batteries or different types of AAA batteries.

Start-up
This is a warm weather appliance
Your air conditioner is designed to cool in warm weather when the outside temperature is above 60 °F (15.6 °C) and below 115 °F (46.1 °C), so it won’t cool a room if it is already cool outside.

  • Condensation is normal
    Air conditioners actually pump the heat and humidity from your room to the outside. Humidity becomes water, and your air conditioner will use most of the water to keep the outside coil cool. If there is excessive humidity, there may be excess water that will drip outside. This is normal operation.

  • Frosting
    This usually occurs because of insufficient airflow across the coils, a dirty filter, cool damp weather, or all these. Set the SYSTEM mode to FAN ONLY and the frost will disappear. Setting the thermostat a little warmer will probably prevent the frosting from recurring.

  • Noises
    All air conditioners make some noise. Friedrich units are designed to operate as quietly as possible. An air conditioner mounted in a wall is quieter than one mounted in a window. It is important to ensure that the chassis seal gasket is properly installed (refer to the Installation Instructions).

WiFi

Use a QR Reader on your phone to Scan this QR Code. It will take you to the Wifi Instructions page of our website.

TROUBLESHOOTING

Troubleshooting TipsFRIEDRICH-CCW15B10B-Room-Air-Conditioner-
\(44\)

INFORMATION FOR THE OWNER

Routine Maintenance

  • Coils & Chassis
    NOTE: Do not use a caustic cleaning agent on coils or base pan. Use a biodegradable cleaning agent and degreaser. The use of harsh cleaning materials may lead to deterioration of the aluminum fins or the coil end plates.
    The indoor coil and outdoor coils and base pan should be inspected periodically (annually or semi-annually) and cleaned of all debris (lint, dirt, leaves, paper, etc.) as necessary. Under extreme conditions, more frequent cleaning may be required. Clean the coils with and base pan with a coil comb or soft brush and compressed air or vacuum. A low pressure washer device may also be used; however, you must be careful not to bend the aluminum fin pack. Use a sweeping up and down motion in the direction of the vertical aluminum fin pack when pressure cleaning coils.
    NOTE: It is extremely important to insure that none of the electrical and/ or electronic parts of the unit get wet when cleaning. Be sure to cover all electrical components to protect them from water or spray.

  • Decorative Front
    Use a damp (not wet) cloth when cleaning the control area to prevent water from entering the unit, and possibly damaging the electronic control. The decorative front and the cabinet can be cleaned with warm water and a mild liquid detergent. Do NOT use solvents or hydrocarbon based cleaners such as acetone, naphtha, gasoline, benzene, etc. The indoor coil can be vacuumed with a dusting attachment if it appears to be dirty. DO NOT BEND FINS. The outdoor coil can be gently sprayed with a garden hose.

  • Air Filter
    The air filter should be inspected weekly and cleaned if needed by vacuuming with a dust attachment or by cleaning in the sink using warm water and a mild dishwashing detergent. Dry the filter thoroughly before reinstalling. Use caution, the coil surface can be sharp.

  • Blower Wheel / Housing / Condensor Fan / Shroud
    WARNING: Service of this product (aside from filter maintenance) shall only be performed by trained service personnel. Refer to the Service Manual for procedures on how to inspect and maintain the interior of the unit and its components. A QR code is located in section A.4 which will help you locate the service manual online. Inspect the indoor blower and its housing, evaporator blade, condenser fan blade and condenser shroud periodically (yearly or bi- yearly) and clean of all debris (lint, dirt, mold, fungus, etc.). Under extreme conditions, more frequent cleaning may be necessary. Clean the blower housing area and blower wheel with an antibacterial/antifungal cleaner. Use a biodegradable cleaning agent and degreaser on condenser fan and condenser shroud. Use warm or cold water when rinsing these items. Allow all items to dry thoroughly before reinstalling them.

Warranty

FIRST YEAR
ANY PART: If any part supplied by FRIEDRICH fails because of a defect in workmanship or material within twelve months from date of original purchase, FRIEDRICH will repair the product at no charge, provided room air conditioner is reasonably accessible for service. Any additional labor cost for removing inaccessible units and/or charges for mileage related to travel by a Service Agency that exceeds 25 miles one way will be the responsibility of the owner. This remedy is expressly agreed to be the exclusive remed within twelve months from the date of the oriainal purchase.

SECOND THROUGH FIFTH YEAR
SEALED REFRIGERANT SYSTEM: If the Sealed Refrigeration System (defined for this purpose as the compressor, condenser coil, evaporator coil, reversing valve, check valve, capillary, filter drier, and all interconnecting tubing) supplied by FRIEDRICH in your Room Air Conditioner fails because of a defect in workmanship or material within sixty months from date of purchase, FRIEDRICH will pay a labor allowance and parts necessary to repair the Sealed Refrigeration System; PROVIDED FRIEDRICH will not pay the cost of diagnosis of the problem, removal, freight charges, and transportation of the air conditioner to and from the Service Agency, and the reinstallation charges associated with repair of the Sealed Refrigeration System. All such cost will be the sole responsibility of the owner. This remedy is expressly agreed to be the exclusive remedy within sixty months from the date of the original purchase.

APPLICABILITY AND LIMITATIONS: This warranty is applicable only to units retained within the Fifty States of the U.S.A., District of Columbia, and Canada. This warranty is not applicable to:

  1. Air filters, fuses, batteries and the front grille removal tool.
  2. Products on which the model and serial numbers have been removed.
  3. Products which have defects or damage which results from improper installation, wiring, electrical current characteristics, or maintenance; or caused by accident, misuse or abuse, fire, flood, alterations and/or misapplication of the product and/or units installed in a corrosive atmosphere, default or delay in performance caused by war, government restrictions or restraints, strikes, material shortages beyond the control of FRIEDRICH, or acts of God.

OBTAINING WARRANTY PERFORMANCE: Service will be provided by the FRIEDRICH Authorized Dealer or Service Organization in your area. They are listed in the Yellow Pages. If assistance is required in obtaining warranty performance, write to: Room Air Conditioner Service Manager (the Friedrich address is at the top of this warranty) or email [email protected].
LIMITATIONS: THIS WARRANTY IS GIVEN INSTEAD OF ALL OTHER WARRANTIES. Anything in the warranty notwithstanding, ANY IMPLIED WARRANTIES OF FITNESS FOR PARTICULAR PURPOSE AND/OR MERCHANTABILITY SHALL BE LIMITED TO THE DURATION OF THIS EXPRESS WARRANTY. MANUFACTURER EXPRESSLY DISCLAIMS AND EXCLUDES ANY LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGE FOR BREACH OF ANY EXPRESSED OR IMPLIED WARRANTY.

Performance of Friedrich’s Warranty obligation is limited to one of the following methods:

  1. Repair of the unit
  2. A refund to the customer for the prorated value of the unit based upon the remaining warranty period of the unit.
  3. Providing a replacement unit of equal value

The method of fulfillment of the warranty obligation is at the sole discretion of Friedrich Air Conditioning.
NOTE: Some states do not allow limitations on how long an implied warranty lasts, or do not allow the limitation or exclusion of consequential or incidental damages, so the foregoing exclusions and limitations may not apply to you.
OTHER: This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.
PROOF OF PURCHASE: Owner must provide proof of purchase in order to receive any warranty related services.
All service calls for explaining the operation of this product will be the sole responsibility of the consumer. All warranty service must be provided by an Authorized FRIEDRICH Service Agency, unless authorized by FRIEDRICH prior to repairs being made.

Friedrich Air Conditioning Company
10001 Reunion Place, Suite 500
San Antonio, TX 78216
800.541.6645
www.friedrich.com

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

FRIEDRICH User Manuals

Related Manuals