Product Information

Specifications

  • Product Model: QG-PRO-PM-TCA-B
  • Maximum Weight Capacity: 181kg (400lbs)
  • Truss Max. Diameter: 3
  • 1.5 NPT Pipe Compatibility

Product Usage Instructions

Installing the Ceiling Adapter to the Truss

  1. Identify the type of truss you have.
  2. Place the U bolts (B) over the truss.
  3. Attach the adapter plate (A) to the truss using the hex nuts (E), washers (C,D), and tighten them using a 17mm socket wrench.

Joining the Pipe to the Ceiling Adapter

  1. Connect the 1.5 NPT pipe end to the ceiling plate.
  2. Use screws (F or G) to secure the position of the pipe.
  3. Tighten the screws (F or G) using an allen key (H).

IMPORTANT: Do not loosen screws all the way when making adjustments, as this may disconnect the parts and cause injury or property damage.

Maintenance

Please check that the ceiling adapter is secure and safe to use at regular intervals. If you have any questions regarding any of the instructions or warnings, please contact your local distributor or QualGear technical support via email at

Parts Checklist

IMPORTANT: Before starting installation, please check that all parts shown in this checklist are included. If any parts are missing or damaged, contact your local distributor or

for replacement parts and do not start assembly and installation until you receive all the parts.

FAQ

  • Can I exceed the maximum weight capacity specified?
    • No, exceeding the maximum weight capacity may result in serious injury or property damage. Always ensure that the weight does not exceed the specified limit.
  • Can I use this product outdoors?
    • No, all QualGear products are intended for indoor use only. Using them outdoors will void the limited warranty.
  • What should I do if any parts are missing or damaged?
    • If any parts are missing or damaged, please contact your local distributor or support@qualgear.com for replacement parts before starting assembly and installation.

Installing the Ceiling Adapter to the Truss

Position “U” bolts (B) over truss, and attach adapter plate (A) with the hex nuts (E), and washers (C,D) and tighten using a 17mm socket wrench.

TYPES OF TRUSS

QualGear-QG-PRO-PM-TCA-B-Truss-Ceiling-Adapter-
fig-1

Joining the Pipe to the Ceiling Adapter

IMPORTANT!

Do not loosen screws all the way when making adjustments, this will disconnect the parts and may cause injury or property damage.

NOTE Please read the entire installation manual before you start installation and assembly.

WARNING

  • Do not begin to install your QualGear product until you have read and understood all the instructions and warnings contained in this installation manual. If you have
    any questions regarding the instructions, for US customers please contact QualGear customer support via email at support@qualgear.com. For all international customers, please contact your local distributor.

  • This product should only be installed by someone of good mechanical aptitude, has experience with basic building construction, and fully understands these instructions.

  • This product was designed to be installed and utilized only as specified in this manual. Improper installation of this product may cause damage or serious injury. QualGear is not liable for the improper use or installation of its products.

  • Make sure that the supporting surface will safely support the combined load of the equipment and all attached hardware and components.

  • Always use an assistant or mechanical lifting equipment to safely lift and position the equipment.

  • Tighten screws firmly, but do not over-tighten. Over-tightening can damage the items, greatly reducing their holding power.

  • ALL QUALGEAR products are intended for indoor use only and any outdoor use voids the limited warranty. For warranty information, please visit:

  • Never exceed the maximum rated weight specified in this manual.

  • All hardware must be used at the designated points in the installation instructions to prevent property damage and/or personal injury.

  • This product was designed to be compatible with all standard 1.5″ NPT pipes.

IMPORTANT: Installers must verify that the supporting surface will safely support the combined weight of the equipment and all attached hardware and components.

Maintenance

Please check that the ceiling adapter is secure and safe to use at regular intervals. If you have any questions regarding any of the instructions or warnings, please contact your local distributor (OR) contact QualGear technical support via email at support@qualgear.com.

Parts Checklist

IMPORTANT: Before starting installation, please check that all parts shown in this checklist are included. If any parts are missing or damaged, contact your local distributor or support@qualgear.com for replacement parts and do not start assembly and installation until you receive all the parts .QualGear-QG-PRO-PM-TCA-B-Truss-Ceiling-Adapter-fig-5

Hardware Package

QualGear-QG-PRO-PM-TCA-B-Truss-Ceiling-Adapter-
fig-6

CAUTION!

Do not exceed the maximum rated weight specified. Otherwise, serious injury or property damage may occur.