PACIFIC ENERGY Neo 2.5 LE Wood Stove Instruction Manual
- June 16, 2024
- Pacific Energy
Table of Contents
- PACIFIC ENERGY Neo 2.5 LE Wood Stove Instruction Manual
- SAFETY NOTICE
- Rating Label
- Safety
- Operation
- Maintenance
- Maintenance Checks
- Baffle Removal
- Dimensions
- Crate Removal
- Assembly – Side Panels
- Floor Protector
- Residential Installation
- Combustion Air
- Mobile Home Installation
- Optional Blower
- Firebrick Installation
- Trouble Shooting
- Parts Diagram – NEO 2.5 LE
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
PACIFIC ENERGY Neo 2.5 LE Wood Stove Instruction Manual
MODEL: NEO 2.5 LE
SAFETY NOTICE
If this stove is not properly installed, a house fire may result. For your safety, follow the installation instructions. Contact local building or fire officials about restrictions and installation inspection requirements in your area.
Meets the Environmental Protection Agency’s 2020 Particulate Emission Standards (Cord Wood).
Visit www.pacificenergy.net for the most recent version of this manual
WARNING
HOT GLASS WILL CAUSE BURNS.
DO NOT TOUCH GLASS UNTIL COOLED.
NEVER ALLOW CHILDREN TO TOUCH GLASS.
STATE of CALIFORNIA
WARNING: this product can expose you to chemicals including ceramic
fibers, which are known to the state of California to cause cancer,and to
carbon monoxide, which is known to the state of California to cause birth
defects or other reproductive harm.
For more information go to www.p65warnings.ca.gov.
This warning is applicable to all
PACIFIC ENERGY FIREPLACE PRODUCTS
PLEASE SAVE THESE INSTRUCTIONS
NOTE: WE STRONGLY RECOMMEND THAT SMOKE AND CARBON MONOXIDE DETECTORS BE
INSTALLED IN THE AREA WHERE THE HEATER IS TO BE INSTALLED.
If smoke detectors have been previously installed, you may notice that they
are operating more frequently. This may be due to curing of stove paint or
fumes caused by accidentally leaving the fire door open. Do not disconnect the
detectors.
SAFETY NOTICE: I f this stove is not properly installed, a house fire may result. For your safety, follow the installation instructions. Contact local building or fire officials about restrictions and installation inspection requirements in you area.
Please read this entire manual before you install and use your new room
heater. Failure to follow instructions may result in property damage, bodily
injury, or even death.
Experience will give you the right settings for proper combustion and
efficient burning. Remember the correct air inlet setting is affected by
variables such as type of wood, outside temperature, chimney size and weather
conditions. With practice, you will become proficient in operating your heater
and will obtain the performance for which it was designed.
Rating Label
PLEASE SAVE THESE INSTRUCTIONS
This manual describes the installation and operation of the Pacific Energy,
NEO 2.5 LE Freestanding wood heater.
SAFETY NOTICE: If this stove is not properly installed, a house fire may
result. For your safety, follow the installation instructions. Contact local
building or fire officials about restrictions and installation inspection
requirements in you area.
Please read this entire manual before you install and use your new room
heater. Failure to follow instructions may result in property damage, bodily
injury, or even death.
This heater meets the 2020 U.S. Environmental Protection Agency’s cordwood
emission limits for wood heaters sold after May 15, 2020 Tested to ASTM E3053.
Model NEO 2.5 LE: 2.0 g/hr..
Under specific test conditions this heater has been shown to deliver heat at
rates ranging from 15,850 to 59,850 Btu/hr.
Efficiency and BTU Output
- Weighted Average Lower Heating Value (LHV) efficiency as tested using CSA B415 Performance testing of solid-fuel-burning heating appliances. LHV assumes the moisture is already in a vapour state so there is no loss of energy
- Weighted Average Higher Heating Value (HHV) efficiency as tested using CSA B415 Performance testing of solid-fuel-burning heating appliances. HHV includes the energy required to vaporize the water in the fuel
- The range of BTU outputs is based on efficiency using CSA B415 Performance testing of solid-fuel-burning heating appliances and burn rates from the low and high EPA tests using Douglas Fir dimensional lumber.
Safety
CAUTION: Never use gasoline, gasoline type lantern fuel, kerosene, charcoal lighter fluid or similar liquids to start or “freshen up” a fire in this heater. Keep all such liquids well away from the heater while it is in use.
Instruct all members of your family on the safe operation of the heater. Ensure they have enough knowledge of the entire system if they are expected to operate it. Stress the section on chimney fires and the importance of following the steps outlined “In Case of a Chimney Fire” on page 5.
Chimney Smoke and Creosote Formation
When wood is burned slowly, it produces tar and other organic vapors, which combine with expelled moisture to form creosote. The creosote vapors condense in the relatively cool chimney flue of a slow burning fire. As a result, creosote residue accumulates on the flue lining. When ignited, this creosote makes an extremely hot fire. The chimney connector and chimney should be inspected periodically (at least once every two months) during the heating season to determine if a creosote buildup has occurred. If creosote has accumulated (3 mm. or more), it should be removed to reduce the risk of a chimney fire.
1. Highest smoke densities and emissions occur when a large amount of wood is added to a bed of hot coals and the air inlet is closed. The heated wood generates smoke, but without ample air, the smoke cannot burn. Smoke-free, clean burning requires small fuel loads, two or three logs at a time or 1/4 to 1/2 of fuel load and leaving the air inlet relatively wide open, especially during the first 10 to 30 minutes after each loading, when most of the smoke generating reactions are occurring. After 30 minutes or so, the air inlet can be turned down substantially without excessive smoke generation. Wood coals create very little creosote-producing smoke.
2. The cooler the surface over which the wood smoke is passing, the more
creosote will be condensed. Wet or green wood contributes significantly to
creosote formation as the excess moisture that is boiled off cools the fire,
making it difficult for the tars and gases to ignite, thus creating dense
smoke and poor combustion.
This moisture-laden smoke cools the chimney, compounding the problem by
offering the smoke the ideal place to condense.
In summary, a certain amount of creosote is inevitable. Regular inspection and cleaning is the solution. The use of dry, seasoned wood and ample combustion air will help to minimize annoying smoke emissions and creosote buildup.
Chimney Fires
The dangerous side effect of excessive creosote buildup is a chimney fire.
This causes much higher than normal temperatures in the chimney and on its
exterior surfaces. Temperatures inside the chimney can exceed 2000°F (1100°C).
Ignition of nearby or touching combustible material is more likely during a
chimney fire. Proper clearances are critical to prevent damage during such a
fire.
Chimney fires are easy to detect; they usually involve one or more of the following:
• Flames and sparks shooting out of the top of the chimney
• A roaring sound
• Vibration of the chimney
To Avoid a Chimney Fire
- Burn wood cleanly. Do not burn wet wood or turn down the unit too quickly after loading.
- Do not let creosote build up to a point where a chimney fire is possible.
- Do not have fires in the heater that may ignite chimney fires. These are excessively hot fires, such as when burning household trash, cardboard, Christmas tree limbs, or even ordinary fuel wood; (e.g. with a full load on a hot bed of coals and with the air inlet wide open for more time than is needed to completely char a fresh fuel load.)
- The Chimney and connector pipe should be inspected /cleaned periodically.
In Case of a Chimney Fire
1. Prepare to evacuate to ensure everyone’s safety. Have a well understood
plan of action for evacuation. Have a place outside where everyone is to meet.
2. Close air inlet on stove.
3. Call local fire department. Have a fire extinguisher handy. Contact your
local municipal or provincial fire authority for further information on how to
handle a chimney fire. It is most important that you have a clearly understood
plan on how to handle a chimney fire.
4. After the chimney fire is out, the chimney must be cleaned and checked for
stress and cracks before starting another fire. Also check combustibles around
the chimney and the roof.
• The services of a certified installer/Chimney Sweep (from one of the
associations listed below), is strongly recommended to inspect and service
your Chimney system
NFI (National Fireplace Institute®) in the United States,
CSIA (Chimney Safety Institute of America) in the United States and Canada,
WETT (Wood Energy Technology Transfer) in Canada or
APC (Association des Professionnels du Chauffage) in Quebec
Curing of the Paint Finish
To achieve the best finish, the paint on your stove must be baked on. When
burning your stove for the first 2-3 times it is very important that the room
be well ventilated. Open all windows and doors. Smoke and fumes caused by the
curing process may cause discomfort to some individuals. Follow the procedures
on the information sheet included with your stove from STOVE BRIGHT (Forrest
Paint).
WARNING: Never use chemicals or any other volatile liquid to start a fire. Do not burn garbage, or flammable fluids such as gasoline, naptha, or engine oil.
Operation
CAUTION: Hot while in operation. Keep children, clothing and furniture away.
Contact may cause skin burns.
WARNING: Always keep loading door closed when burning. This heater is not
designed for open door burning.
WARNING: No alteration or modification of the combustion air control assembly
is permitted. Any tampering will void warranty and could be very hazardous.
WARNING: Do not use grates or andirons to elevate the fuel. Burn directly on
the fire bricks. Replace broken or missing bricks. Failure to do so may create
a hazardous condition.
Wood Selection
This heater is designed to burn natural wood only. Higher efficiency and lower
emissions generally result when burning air-dried seasoned hardwoods, as
compared to softwoods or to green or freshly cut hardwoods.
Wood should be properly air dried (seasoned) for six months or more. Wet or
undried wood will cause the fire to smoulder and produce large amounts of
smoke and creosote. Wet wood also produces very little heat and tends to go
out often. Wood should be stored under cover away from open flame or heat
sources.
DO NOT BURN :
- These materials contain chlorides which will rapidly destroy metal surfaces and void warranty.
Burning these materials may result in the release of toxic fumes or render the heater ineffective and cause smoke.
Do not burn anything but wood. Other fuels, e.g. Charcoal, can produce large amounts of carbon monoxide, a tasteless, odorless gas that can kill. Under no circumstances should you attempt to barbecue in this heater.
The prohibition against burning these materials does not prohibit the use of fire starters made from paper, cardboard, saw dust, wax and similar substances for the purpose of starting a fire in an affected wood heater.
How to Test Your Wood
Add a large piece of wood to the stove when it has a good large bed of coals.
It is dry if it is burning on more than one side within one minute. It is damp
if it turns black and lights within three minutes. If it sizzles, hisses and
blackens without igniting in five minutes it is too wet and should not be
burnt
Lighting a fire
WARNING: Never use chemicals or any other volatile liquid to start a fire.
1. Adjust air control to “High” position (all the way to the left) and open
door.
2. Place crumpled newspaper in the centre of the heater and crisscross with
several pieces of dry kindling. Add a few small pieces of dry wood on top.
3. Ignite the paper and leave the door ajar approximately 1/2″(13mm) –
1″(25mm) until the wood kindling is fully engulfed in flame.
4. After the kindling is fully engulfed add a few small logs. Close door.
5. Begin normal operation after a good coal base exists and wood has charred.
Normal Operation
WARNING: This wood heater has a manufacturer-set minimum low burn rate that
must not be altered.
It is against federal regulations to alter this setting or otherwise operate
this wood heater in a manner inconsistent with the operating instructions in
this manual.
1. Set air control to a desired setting. If smoke pours down across the glass
(waterfall effect) this indicates you have shut the control down too soon or
you are using too low a setting. The wide range control panel makes finding
the desired setting for your application easy. As every home’s heating needs
vary (i.e. Insulation, windows, climate, etc.) The proper setting can only be
found by trial and error and should be noted for future burns.
2. To refuel, adjust air control to high, and give the fire time to brighten.
Open the door slowly, this will prevent back puffing.
3. Use wood of different shape, diameter and length (up to 18″(457mm)). Load
your wood endwise and try
to place the logs so that the air can flow between them. Always use dry wood.
4. Do not load fuel to a height or in such a manner that would be hazardous
when opening the door.
5. For extended or overnight burns, unsplit logs are preferred. Remember to
char the wood completely on maximum setting before adjusting air control for
overnight burn.
• Burn wood only, dry and well seasoned. The denser or heavier the wood when
dry, the greater its heat value. This is why hardwoods are generally
preferred. Green or wet wood will cause a rapid buildup of creosote. If you
feel it is necessary to burn wet or unseasoned wood, do so only with the air
inlet set open enough to maintain a good strong fire and fairly high chimney
temperatures. Do not attempt to burn overnight using green wood or wet wood.
Wet wood can cause up to 25% drop in heater output, as well as contributing
significantly to creosote buildup.
DO NOT OVER FIRE THIS HEATER: Attempts to achieve heat output rates that exceed heater design specifications can result in permanent damage to the heater and chimney. A glowing red, top or vent pipe are indications of over firing. Failure to rectify an over firing condition can be hazardous and may void the manufacturer’s warranty.
Restarting After Extended or Overnight Burns
1. Open door and rake hot embers towards the front of the heater. Add a
couple of dry, split logs on top of embers, close door.
2. Adjust air control to high and in just a few minutes, logs should begin
burning.
3. After wood has charred, reset air control to desired setting.
4. To achieve maximum firing rate, set control to high “H”. Do not use this
setting other than for starting or preheating fresh fuel loads.
Proper Draft
1. Draft is the force which moves air from the appliance up through the
chimney. The amount of draft in your chimney depends on the length of the
chimney, local geography, nearby obstructions and other factors.
2. Too much draft may cause excessive temperatures in the appliance. An
uncontrollable burn or a glowing red stove part or chimney indicates excessive
draft.
3. Inadequate draft may cause back puffing into the room and plugging of the
chimney. Smoke leaking into the room through appliance and chimney connector
joints indicates inadequate draft.
Remember the correct air inlet setting is affected by variables such as type
of wood, outside temperature, chimney size and weather conditions.
Ash Removal
Caution: Ashes are to be removed only when the heater is cold. Whenever ashes
get 3″(76mm) to 4″(102mm) deep in your firebox, and when fire has burned down
and cooled, remove excess ashes. Leave an ash bed approximately 1″ (25 mm)
deep on the firebox bottom to help maintain a hot charcoal bed.
Ash Clean out system:
The ash dump handle is located behind the Lower Grill, under the ash lip on
the left hand side. To access the handle, pull the Lower Grill up to unlock
then tip towards to you. To operate ash dump, pull handle out 1/2″(13mm) and
turn clockwise. This will unlock the ash dump and allow it to open. Hold
handle open while pulling ashes into the opening. Avoid large embers as these
still contain heat value. Release handle and push in to lock. Ensure ash dump
door is properly engaged. Fill the cavity with the remaining ash level with
the firebox floor. Lift and pull out ash pan and discard ashes into metal
container. Replace ash pan and ensure it is seated properly.
Do not burn with ash dump door open. Doing so will create a hazardous condition. Always leave about 1″(25mm) of ash when cleaning.
Disposal of Ashes
Ashes should be placed in a metal container with a tight fitting lid. The
closed container of ashes should be placed on a non-combustible floor or on
the ground, well away from all combustible materials, pending final disposal.
If the ashes are disposed of by burial in soil or otherwise locally dispersed,
they should be retained in closed container until all cinders have thoroughly
cooled. Other waste should not be placed in this container.
Maintenance
WARNING: Never use chemicals or any other volatile liquid to start a fire. Do not burn garbage, or flammable fluids such as gasoline, naptha, or engine oil.
WARNING: ONLY USE MATERIALS SUPPLIED BY MANUFACTURER WHEN DOING MAINTENANCE OR REPLACEMENTS.
- If glass becomes darkened through slow burning or poor wood, it can readily be cleaned with fireplace glass cleaner when stove is cold. Never scrape with an object that might scratch the glass. The type and amount of deposit on the glass is a good indication of the flue pipe and chimney buildup. A light brown dusty deposit that is easily wiped off usually indicates good combustion and dry, well-seasoned wood and therefore relatively clean pipes and chimney. On the other hand, a black greasy deposit that is difficult to remove is a result of wet and green wood and too slow a burning rate. This heavy deposit is building up at least as quickly in the chimney.
- DOOR GASKETS – The gasket used by Pacific Energy (3/4″(19mm) High density fiberglass rope) requires only light pressure to seal. This will prolong seal life. It is important that the door seal be maintained in good condition. Periodically inspect seals and replace if necessary. Follow the instructions included in the kit, available from your nearest Pacific Energy dealer. See Replacement Parts List
- DOOR GLASS – Do not slam loading door or otherwise impact glass. When closing door, make sure that no logs protrude to impact the glass. If the glass gets cracked or broken, it must be replaced before using the stove. Replacement glass can be obtained from your dealer. Use 18″(457mm) x 10-1/4″(260mm) x 5 mm. Ceramic glass only. See Replacement Parts List page 28. Do not substitute with any other type of Glass.
• To remove broken glass, undo the four retaining screws and remove clamps and frame, noting position for re-assembly. Remove all particles of glass . Be careful as they are very sharp. Install new glass complete with gasket. Replace frame, clamps and screws.
CAUTION:
– Do not overtighten, tighten screws very carefully
– Do not clean glass when hot
– Do not use abrasive cleaners on glass
4. The area where boost combustion air enters the firebox must be kept clear
of excessive ash buildup which will block air flow. This area is at the front
of the firebox.
5. Do not store wood within heater installation clearances, or within the
space required for fuel loading and ash removal. Keep the area around the
heater clean and free of loose combustibles, furniture, newspapers, etc.
6. Establish a routine for the fuel, wood burning and firing technique. Check
daily for creosote buildup until experience shows how often you need to clean
to be safe.
7. Be aware that the hotter the fire, the less creosote is deposited. Weekly
cleaning may be necessary in mild weather, even though monthly cleaning is
usually enough in the coldest months when burning rates are higher. When wood
is burned slowly, it produces tar and other organic vapours, which combine
with expelled
Maintenance Checks
Check the following parts for damage such as cracks, excessive corrosion, burned out sections and excessive warping: (See website for descriptions and more detail)
Weekly:
• Firebrick – Visual, for cracking.
• Door Gasket – sagging, placement, damage.
Monthly
• Brick Rail Tabs and Brick Rails.
• Air Riser Tube in the back of the firebox.
• Back side of Airwash Chamber.
• Baffle Locking Pin.
• Boost tube cover holes – located in center of manifold, bottom front of
firebox.
When Cleaning the Chimney System:
• Top Baffle Board / Blanket.
• Baffle.
• Top Heat Shield and mounting bolts.
• Baffle Gasket.
• Brick Rail Tabs and Brick Rails.
• Air Riser Tube in the back of the firebox..
Blower:
• The optional blower should be cleaned out a minimum every six months by
using a vacuum on the grill openings in the back and bottom of the blower
casing, to remove any dust and debris.
Baffle:
• Some warping of the baffle is normal(up to 1/4” or .65cm). Replace if the
baffle has permanent warping greater than this or has cracking or breakage.
• Please contact your Dealer if you experience any of the damage listed above.
Continuing to operate your stove with broken parts can accelerate damage to
other parts and may void your warranty
Baffle Removal
Chimney connector pipe should be disconnected from stove to clean and inspect. Only if this is not possible should you remove baffle assembly.
WARNING: If you Sweep/Clean the chimney with the baffle removed, be sure to plug the top of the baffle tube in the back of the firebox before sweeping or cleaning. Failure to prevent ash or soot from falling into the baffle tube will cause incorrect operation and will lead to premature burn out of the tube or baffle.
DO NOT OPERATE WITH BAFFLE ASSEMBLY OR INSULATION REMOVED.
Baffle Removal
1. Remove retaining pin at the back of the firebox, just under the baffle.
2. Lift the Baffle up to disconnect from the Baffle Supply Tube.
3. Pull the Baffle towards you, then tilt it sideways to drop down and remove
from firebox. You may need to remove the opposite side brick rail to allow the
Baffle to drop down. To remove the Brick Rail, remove the brick directly under
it then lift the rail up and inward to clear the locating pins
4. Inspect the gasket between baffle and supply tube. If necessary, replace
with gasket (prt#80000365) available from your Pacific Energy dealer.
5. Re-install baffle assembly in reverse order.
Dimensions
Crate Removal
1. Carefully remove the crate top and supports.
2. Remove plastic cover.
3. Using a 7/16″(12mm) wrench, remove lag bolts that secure the unit to the
pallet.
Assembly – Side Panels
Carefully remove the panels from their box. Try not twist or bend the panels as it may damage the finish.
With the pattern at the top, guide the Side Panel’s front tabs into the slots on the front of the Panel Mounting Brackets located on the side of the unit. Pull towards the back to fully engage (Figure 2).
Using the screws provided attach the Panel to the unit. Use the fibre washers between the panel and the screw head on enamel panels to prevent chipping (Figure 3).
Floor Protector
The stove may be installed on a combustible floor provided noncombustible
ember protection is used.
This protection must extend as follows:
In USA: 16″ (406 mm) to the front and 8″ (203 mm) to the sides of the fuel
loading door opening. See Figure 4, below.
In Canada: 18″ (457 mm) on the firing side and 8″ (203 mm) to the other sides
(Figure 5).
This protection is also required under the chimney connector and 2″ (51 mm)
beyond each side.
Residential Installation
Clearances:
Clearances may be reduced with various heat shielding/insulating materials.
Consult CSA B365 or NFPA 211 and local fire codes and authorities for
approval. For close clearances, use a listed double-wall connector.
NOTE: local/national codes or regulations may override some guidelines in this
manual
We recommend that our products be installed and/or serviced by professionals
who are certified by a “Qualified agency”;
NFI (National Fireplace Institute®) in the United States,
CSIA (Chimney Safety Institute of America) in the United States and Canada,
WETT (Wood Energy Technology Transfer) in Canada or
APC (Association des Professionnels du Chauffage) in Quebec
Warning: Under no circumstances is this heater to be installed in a makeshift
or “temporary” manner.
It may be fired only after the following conditions have been met.
DO NOT ATTEMPT TO CONNECT THIS HEATER TO ANY AIR DISTRIBUTION DUCT.
DO NOT INSTALL IN ANY FIREPLACE.
Outside combustion air or fresh air into the room may be required in your
area, consult local building codes (see Combustion Air section).
Chimney and Connector
• The chimney system must be a ULC-S629 or UL-130HT listed Stainless chimney
or a Masonry chimney suitable for use with solid fuel, that is lined, in good
condition and meets fire and building codes.
• The chimney flue size should be the same as the stove outlet (6 inches) for
optimal performance. Reducing or increasing the flue size may adversely affect
stove performance.
• Chimney flue exit is to be 3 feet (1 m.) above roof and two feet (0.6 m.)
above highest projection within 10 feet (3 m.) horizontally.
• The installation must meet all local codes.
• Do not connect this unit to a chimney flue serving another appliance.
Minimum system height is 15 feet (4.6 m.) (measured from base of appliance).
BOTH CHIMNEY SYSTEM AND CONNECTOR MUST BE LISTED TO:
IN CANADA – ULC S-641 LISTED for double wall connector and ULC-S629 LISTED
CHIMNEY,
IN USA – UL-103 HT LISTED CONNECTOR AND CHIMNEY
When using a Double-Wall Connector
• Use a listed double-wall connector.
• If a listed chimney and double-wall connector are to be connected to the
stove, install all components as per the chimney/connector manufacturer’s
installation requirements.
When using a Single-Wall (smoke pipe) Connector
The single wall pipe section must be:
• If you are using smoke pipe/chimney connector in conjunction with the listed
chimney system, consult local/national fire or building codes for connector
installation. Follow the chimney manufacturer’s complete instructions for the
installation of the chimney system.
• As short and straight as possible, use six inch diameter, 24 gauge black
pipe that is clean and in new condition.
• Installed with the crimped or male ends pointing down. (This will carry any
liquid creosote or condensation back into the stove) and secured at every
joint and collar with 3 sheet metal screws.
• The chimney connector shall not pass through an attic, roof space, closet or
similar concealed space, floor, or ceiling. Where passage through a wall, or
partition of combustible material is desired, the installation shall conform
to CAN/CSA-B365, Installation Code for Solid-Fuel-Burning Appliances and
Equipment or NFPA 211 Standard for Chimneys, Fireplaces, Vents and Solid-Fuel
Burning Appliances.
Installation Procedure
1. Select the position for your wood stove based on the clearances diagram.
Position the floor protection and stove.
2. Mark the position for the hole in the ceiling and roof by using a string
and plumb-bob hanging over the exact center of the stoves flue pipe.
3. Check that the intended location will not interfere with floor joists,
ceiling joists or rafters before proceeding further. Adjust if necessary and
reconfirm the clearance’s from the stove to combustibles.
4. Carefully follow the directions of the listed chimney for installation of
the chimney system from the ceiling through to the rain cap. This may include
framing in holes etc.
5. Start installing smoke pipe / chimney connector, slip the crimped edge of
the pipe inside the stove collar. Use holes provided in collar to secure pipe
with two screws.
6. Install the remaining lengths of pipe one on top of the other up to the
finished height of the chimney and using the manufacturers approved adapter,
secure to each other. A slip section can make this easier.
Combustion Air
Intake or combustion air can be supplied to the stove in one of two ways.
Consult your local building code or CAN/CSA-B365, Installation Code for Solid-
Fuel-Burning Appliances and Equipment before proceeding. Outside air supply –
(Necessary for mobile home installation, optional for residential
installation.)
To draw outside air through the floor – This hole must get its air from a
ventilated crawl space or be extended with duct to the outdoors. See “Figure
7: Residential venting.” on page 18. The use of outside combustion air for
residential installation requires the unit to be secured to the structure to
prevent dislodging of the air duct.
• Cut or drill a hole in the floor, (large enough to fit 4″ metal flex
venting) behind where the unit will sit. Once the stove is in place, attach
the 4″ Intake Starter to the Ash Box Enclosure. Connect thru the floor with
the 4″(100mm) i.d. metal flex pipe.
To draw outside air from behind the stove, Use a 4″(100mm) Air intake. Cut or
drill the recommended size hole through a wall behind the unit.
• Install the 4″ Intake Starter over the hole in the rear of the Ash Box
enclosure. Attach metal flex between the starter and the Air Intake.
Room air supply – The stove will draw its air from the room through the
opening in the Ash Box Enclosure and into the firebox intake. Note: The living
space around the heater must be well ventilated with good air circulation.
Anything that
may cause a negative pressure can cause gases or fumes to be pulled into the
living area. During extremely cold weather, and especially when burning at
very slow rates, the upper parts of the exposed chimney may ice up, partially
blocking the flue gases. If blockage occurs, flue gases may enter the living
space.
Figure 7: Residential venting.
Figure 8: Masonry chimney install.
Through Wall Installations
(as per NFPA 211-2013)
ATTENTION: VAPOUR BARRIER MUST BE MAINTAINED WHEREVER CHIMNEY OR OTHER COMPONENTS PENETRATE TO THE EXTERIOR OF THE STRUCTURE. SEE LOCAL BUILDING CODES FOR PROPER AND APPROVED METHODS OF MAINTAINING VAPOUR BARRIER.
Minimum Clearance 12 in. (305mm) to combustibles
System A. Minimum 3.5 in. (90 mm) thick brick masonry wall framed into combustible wall with a minimum of 12 in. (305 mm) brick separation from clay liner to combustibles. Fireclay liner (ASTM C 315, Standard Specifications for Clay Fire Linings, or equivalent), minimum 5/8 in. (16 mm) wall thickness, shall run from outer surface of brick wall to, but not beyond, the inner surface of chimney flue liner and shall be firmly cemented in place.
Minimum Clearance 9 in. (229mm) to combustibles
System B. Solid-Insulated, listed factory-built chimney length of the same
inside diameter as the chimney connector and having 1 in. (25.4 mm) or more of
insulation with a minimum 9 in. (229 mm) air space between the outer wall of
the chimney length and combustibles.
The inner end of the chimney length shall be flush with the inside of the
masonry chimney flue and shall be sealed to the flue and to the brick masonry
penetration with non-water-soluble refractory cement. Supports shall be
securely fastened to wall surfaces on all sides.
Fasteners between supports and the chimney length shall not penetrate the
chimney liner.
Minimum Clearance: 6 in. (152mm) to combustibles
System C. Sheet steel chimney connector, minimum 24 gauge [0.024 in. (0.61
mm)] in thickness, with a ventilated thimble, minimum 24 gauge [0.024 in.
(0.61 mm)] in thickness, having two 1 in. (25.4 mm) air channels, separated
from combustibles by a minimum of 6 in. (152 mm) of glass fiber insulation.
Opening shall be covered, and thimble supported with a sheet steel support,
minimum 24 gauge [0.024 in. (0.61 mm))] in thickness.
Supports shall be securely fastened to wall surfaces on all sides and shall be sized to fit and hold chimney section. Fasteners used to secure chimney section shall not penetrate chimney flue liner.
Minimum Clearance: 2 in. (51mm) to combustibles
System D. Solid-Insulated, listed factory-built chimney length with an inside diameter 2 in. (51 mm) larger than the chimney connector and having 1 in. (25.4mm) or more of insulation, serving as a pass-through for a single-wall sheet steel chimney connector of minimum 24 gauge [0.024 in. (0.61 mm)] thickness, with a minimum 2 in. (51 mm) air space between the outer wall of chimney section and combustibles.
Minimum length of chimney section shall be 12 in. (305 mm). Chimney section concentric with and spaced 1 in. (25.4 mm) away from connector by means of sheet steel support plates on both ends of chimney section. Opening shall be covered, and chimney section supported on both sides with sheet steel supports of minimum 24 gauge [0.024 in. (0.61 mm)] thickness.
Supports shall be securely fastened to wall surfaces on all sides and shall be sized to fit and hold chimney section. Fasteners used to secure chimney section shall not penetrate chimney flue liner.
Mobile Home Installation
Warning: Under no circumstances is this heater to be installed in a makeshift or “temporary” manner. It may be fired only after the following conditions have been met.
- DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE.
- DO NOT INSTALL IN A SLEEPING ROOM.
- CAUTION: THE STRUCTURAL INTEGRITY OF THE MOBILE HOME FLOOR, WALL AND CEILING/ ROOF MUST BE MAINTAINED.
- Attach the stove to the floor using two 1/4″ x 2″ or longer lag screws through holes in the legs or the Pedestal base.
- Outside combustion air supply must be used for Mobile Home installations – See “Combustion Air” on page 17.
- The services of a competent or certified installer, are strongly recommended:
NFI (National Fireplace Institute®) in the United States,
CSIA (Chimney Safety Institute of America) in the United States and Canada,
WETT (Wood Energy Technology Transfer) in Canada or
APC (Association des Professionnels du Chauffage) in Quebec
Clearances
This heater must be installed with listed double-wall connector and compatible
ULC-S629 or UL-103HT listed chimney system.
Clearances to combustible surfaces and materials are shown. See picture below.
Consult local fire codes and authorities for approval.
NOTE: Install all components to the connector or chimney manufacturer’s
installation requirements. Consult your chimney supplier/manufacturer for
installation advice.
Optional Blower
The optional blower kit (Part #: 11140001) is equipped with a three prong
power cord and may be installed at any time. Follow the installation
instructions supplied with the kit. Route power supply cord away from heater.
Electrical rating: 115 volts AC-1.02 amps.
Fan output rating: 160 CFM
Blower Operation
Proper blower speed matched with air control setting will ensure peak
performance from your stove. Operate as follows:
• Air control set to “L” (low), operate blower speed control on “Low”. Failure
to turn the blower to low may result in the unit going out.
• Air control set between “L” and “H” (low and high), operate blower speed
control at desired setting.
Automatic: To operate the blower automatically, set the rocker switch on the
side of the fan housing to “Auto” and set the speed control to your desired
setting. This will allow the fan to turn on as the stove heats up to operating
temperature. It will also shut the blower off after the fire has gone out and
the unit has cooled to below a useful heat output range.
Manual: To manually operate the blower, set the rocker switch to “Man” and set
the speed control to your desired setting. This will bypass the temperature
sensing device and allow full control of the blower. Switching from “Auto” to
“Man” or selecting speed may be done anytime.
Note: The Blower will not shut off until it is manually turned off.
Firebrick Installation
Figure 14: NEO 2.5 freestanding brick layout.
Begin firebrick installation with the rear wall.
1. Stand two “A” firebricks vertically behind the right tab located on the
brick rail. Slide the firebrick toward the center of the rear wall (Figure
15).
2. On the left side of the rear wall, stand two “A” bricks with one “B” brick
in between them. Slide the bricks toward the center of the rear wall (Figure
16)
3. On one of the side walls, stand three “A” bricks vertically and push them
back so that they make contact with the “A” bricks on the rear wall. Then
place a “C” brick on top of an “A” brick (Figure 17).
4. Slip an “A” brick horizontally on top of the center and near “A” bricks.
Insert this brick behind the tab as shown in Figure 18.
5. Repeat steps 3 and 4 for the opposite side wall.
6. On the firebox floor, place an “A” brick in each corner and insert one “B”
brick as shown in Figure 19.
7. Place an “A” brick in front of the left side “A” brick located at the rear
of the firebox floor and slide it back so that both “A” bricks are touching.
Then place one “D” brick behind the ash dump and between the “A” brick and “B”
brick (Figure 20).
8. Place a “C” brick on the firebox floor in front of the ash dump and up
against the “A” brick located on the left side of the firebox floor (Figure
21).
9. Finish by placing two “A” bricks on the right side of the firebox floor
followed by the remaining “D” brick placed in the center of the firebox in
front of the “B” brick.
Note: there will be one full sized “A” brick left over as a spare.
Trouble Shooting
Parts Diagram – NEO 2.5 LE
(WHEN ORDERING, INCLUDE PART NUMBER WITH DESCRIPTION)
All parts may be ordered from your nearest Pacific Energy dealer. Contact Pacific Energy for the location of the dealer nearest you.
Figure 23: NEO 2.5LE Parts.
© 2023 Copyright Pacific Energy Fireplace Products LTD.
Reproduction, adaptation, or translation without prior written permission is
prohibited except as allowed under the copyright laws.
For technical support, please contact your retailer
Web site: www.pacificenergy.net
2975 Allenby Rd., Duncan, BC V9l 6V8
Printed in Canada