PACIFIC ENERGY FP25LE Zero Clearance Wood Heater Instruction Manual
- September 30, 2024
- Pacific Energy
Table of Contents
FP25LE Zero Clearance Wood Heater
“`html
Product Specifications
- Model: FP25LE, FP25LE ARCH
- Serial Number: 300424-32
- Country: Australia
- Variants: FP25LE_AS, FP25LE_AR_AS
- Product Code: 100006366
Product Usage Instructions
General Safety
-
Burn only dry and well-seasoned wood. Hardwoods are preferred
for greater heat value. -
Remove excess ashes regularly to prevent fire hazards.
-
Clean darkened glass using fireplace ceramic glass cleaner when
stove is cold. -
Check and maintain door gasket for proper sealing.
Maintenance Checks
It is important to conduct regular maintenance checks on your
FP25LE stove to ensure safe and efficient operation. Follow these
steps:
-
Inspect the door gasket regularly and replace if
necessary. -
Clean the glass door with a fireplace ceramic glass cleaner
when needed. -
Check for any ash buildup and remove excess ashes as
required.
Frequently Asked Questions (FAQ)
Q: Can I use wet or green wood in the stove?
A: No, it is recommended to burn only dry and well-seasoned wood
to avoid creosote buildup and ensure optimal performance.
Q: How should I clean the glass door of the stove?
A: Use a fireplace ceramic glass cleaner when the stove is cold
to clean the glass door. Avoid using any objects that may scratch
the glass.
Q: What should I do if the door gasket needs replacement?
A: Inspect the door gasket periodically and replace it if
necessary. Use a 22mm medium density fiberglass rope gasket for
sealing.
“`
IMPORTANT: KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE
FP25LE
INSTALLATION AND OPERATING INSTRUCTIONS – AUSTRALIA
SERIAL #
AUSTRALIA
SAFETY NOTICE
If this stove is not properly installed, a house fire may result. For your
safety, follow the installation instructions. Contact local building or fire
officials about restrictions and installation inspection requirements in you
area.
MODEL: FP25LE, FP25LE ARCH
300424-32
FP25LE_AS, FP25LE_AR_AS
100006366
Contents
Contents
WE STRONGLY RECOMMEND THAT SMOKE and CARBON MONOXIDE DETECTORS BE INSTALLED IN
THE ROOM WHERE THE UNIT IS INSTALLED.
SAFETY NOTICE: If this stove is not properly installed, a house fire may
result. For your safety, follow the installation instructions. Contact local
building or fire officials about restrictions and installation inspection
requirements in your area.
Please read this entire manual before you install and use your new room
heater. Failure to follow instructions may result in property damage, bodily
injury, or even death.
General Safety………………………………………………………………………………………………….3 Maintenance
Checks……………………………………………………………………………………….4
Weekly: ……………………………………………………………………………………………………………4 Monthly:
………………………………………………………………………………………………………….4 When Cleaning the Chimney System:
………………………………………………………4 Creosote ……………………………………………………………………………………………………………5
Formation and Need for Removal ……………………………………………………………..5 Avoiding a Chimney
Fire………………………………………………………………………………5 In the event of a Chimney Fire
…………………………………………………………………..5 Operation
………………………………………………………………………………………………………….6 Wood
Selection……………………………………………………………………………………………..6 Lighting the
Fire…………………………………………………………………………………………….6 Curing of the New Paint
Finish…………………………………………………………………..6 Normal
Operation………………………………………………………………………………………… 7 Restarting after Overnight
Burn………………………………………………………………… 7 Dimensions
………………………………………………………………………………………………………..8 Minimum Clearances
………………………………………………………………………………………8 Fireplace Installation
……………………………………………………………………………………….9 Chimney
Installation………………………………………………………………………………………. 11 Chimney and
Connector……………………………………………………………………………..11 Room Seal Flue
Kit………………………………………………………………………………………… 12 Combustion Air
……………………………………………………………………………………………… 13 Blower
Operation………………………………………………………………………………………….. 14 Floor
Protection…………………………………………………………………………………………….. 15 Finishing The Chase
……………………………………………………………………………………… 16 Mantel and Finishing Clearances
……………………………………………………………….. 17 Firebrick
Installation……………………………………………………………………………………… 18
Cleaning/Maintenance…………………………………………………………………………………. 19 Ash Removal
………………………………………………………………………………………………… 19 Disposal of Ashes
……………………………………………………………………………………….. 19 Baffle Assembly Removal
………………………………………………………………………….. 19 Chimney Liner
…………………………………………………………………………………………….. 19 Blower Maintenance
………………………………………………………………………………….. 19 Blower
Replacement………………………………………………………………………………….20 Option: Remote Heat Duct Kit
Installation ………………………………………………. 21 Heat Duct Replacement
Parts……………………………………………………………………. 22 Troubleshooting
………………………………………………………………………………………………27 Parts List
………………………………………………………………………………………………………… 28 Rating Label
…………………………………………………………………………………………………… 29
100006366
2
FP25LE_AS, FP25LE_AR_AS_300424-32
General Safety
1. Burn wood only, dry and well seasoned. The denser or heavier the wood when dry,
the greater its heat value. This is why hardwoods are generally preferred. Green or
wet wood will cause a rapid buildup of creosote. Do not attempt to burn
overnight
using green or wet wood. Wet wood can cause up to 25% drop in heater output,
as WARNING:
well as contributing significantly to creosote buildup.
Never use chemicals
2. Remove excess ashes as needed. Excessive ash level could cause embers to roll out the door and create a fire hazard. Maintain a 25mm minimum ash base to support
or any other volatile
proper burning..
liquid to start a fire. Do
3. If glass becomes darkened from slow burning or poor wood, it can readily be cleaned with any fireplace ceramic glass cleaner when stove is cold. Never scrape with an
not burn garbage, or
object that might scratch the glass. The type and amount of deposit on the glass is a flammable fluids such
good indication of flue pipe and chimney buildup. A light brown, dusty deposit that is a gasoline, naptha, or
easily wiped off usually indicates good combustion and dry, well-seasoned wood and, therefore, relatively clean pipes and chimney. On the other hand, a black, greasy deposit
engine oil.
We strongly
that is difficult to remove is a result of wet or green wood and too slow a burning rate. recommend that smoke
This will also create heavy deposit build-up in the chimney. 4. DOOR GASKET – The gasket used by Pacific Energy (22mm medium density fiberglass
detectors be installed.
rope) requires only light pressure to seal. This will prolong seal life. It is important that
the door seal be maintained in good condition. Periodically inspect seals and replace WARNING:
if necessary. 5. DOOR GLASS – Do not slam loading door or otherwise impact glass. When closing
Only use materials
the door, make sure that no logs protrude to contact the glass. If the glass gets cracked supplied by the
or broken, it must be replaced before using the stove. Replacement glass can be obtained from your Dealer. Use only Ceramic glass. Do not substitute with any other
manufacturer when
type.
doing maintenance or
replacements.
GLASS SIZE: 450mm x 260mm x 5 mm thick.
To remove broken glass, remove the door gasket, undo the eight retaining screws and CAUTION
remove the gasket/glass retainers, noting position for re-assembly. Remove all particles
of glass. Be careful, as they are very sharp. Install new glass complete with gasket. -Tighten screws very Replace gasket/glass retainers, screws and door gasket.(Replace door gasket if needed) carefully. Do not overtighten
6. Do not store wood within heater installation clearances, or within the space required -Do not clean glass when hot
for fuel loading and ash removal. Keep the area around the heater clean and free of all -Do not use abrasive
combustibles, furniture, newspapers, etc.
cleaners on glass
7. If the heater requires cleaning, use mild soap and water only. Use of abrasive cleaners will void warranty.
8. Establish a routine for the fuel, wood burning and firing technique. Check daily for creosote buildup until experience shows how often you need to clean to be safe.
9. Be aware that the hotter the fire, the less creosote is deposited. Weekly cleaning may be necessary in mild weather, even though monthly cleaning is usually enough in the coldest months when burning rates are higher.
10. Instruct all members of your family on the safe operation of the heater. Ensure they have enough knowledge of the entire system if they are expected to operate it. Stress the section on chimney fires and the importance of following the steps outlined in “In Case of Chimney Fire”.
FP25LE, FP25LE_AR_AS_300424-32
3
100006366
Maintenance Checks
Check the following parts for damage such as cracks, excessive corrosion,
burned out sections and excessive warping: (See website for descriptions and
more detail)
Weekly:
– Firebrick – Visual, for cracking. – Door Gasket – sagging, placement,
damage.
Monthly:
– Brick rail tabs and brick rails. – Air riser tube in the back of the
firebox. – Back side of airwash chamber. – Baffle locking pin. – Boost tube
cover.
When Cleaning the Chimney System:
– Top baffle board/blanket. – Baffle. – Top heat shield and mounting bolt. –
Baffle Gasket. – Brick Rails. – Manifold.
**- Some warping of the baffle is normal(up to 1 cm).
– Replace if the baffle has permanent warping greater than this or has
cracking or breakage. – Please contact your Dealer if you experience any of
the damage listed above. Continuing to operate your stove with broken parts
may accelerate damage to other parts and may void your warranty
100006366
4
FP25LE_AS, FP25LE_AR_AS_300424-32
Creosote
Formation and Need for Removal
When wood is burned slowly, it produces tar and other organic vapours, which
combine with expelled moisture to form creosote. The creosote vapours condense
in the relatively cool chimney flue of a slow burning fire. As a result,
creosote residue accumulates on the flue lining. When ignited, this creosote
makes an extremely hot fire. The chimney connector and chimney should be
inspected at least once every two months during the heating season to
determine if a creosote buildup has occurred. If creosote has accumulated, it
should be removed to reduce the risk of a chimney fire.
1. Highest smoke levels and densities occur when a large amount of wood is
added to a bed of hot coals and the air inlet is closed. The heated wood
generates smoke, but without ample air, the smoke cannot burn. Smoke-free,
clean burning requires small fuel loads, two or three logs at a time or 1/4 to
1/2 of a fuel load and leaving the air inlet relatively wide open, especially
during the first 10 to 30 minutes after each loading, when most of the smoke
generating reactions are occurring. After 30 minutes or so, the air inlet can
be turned down substantially without excessive smoke generation. Wood coals
create very little creosote-producing smoke.
2. The cooler the surface over which wood smoke is passing, the more creosote
will be condensed. Wet or green wood contributes significantly to creosote
formation as the excess moisture that is boiled off cools the fire, making it
difficult for the tars and gasses to ignite, thus creating dense smoke and
poor combustion. This moisture-laden smoke cools the chimney, compounding the
problem by offering the smoke the ideal place to condense.
In summary, a certain amount of creosote is inevitable and must be lived with.
Regular inspection and cleaning is the solution. The use of dry, seasoned wood
and ample combustion air will help to minimize the buildup.
Avoiding a Chimney Fire
Excessive creosote build-up can cause a chimney fire. During a fire the inside
temperatures in a chimney can exceed 1100 degrees C. This causes much higher
than normal temperatures in the chimney and on its exterior surfaces thus
ignition of nearby or touching combustible material is more likely during a
chimney fire.
Signs of a chimney fire may be one or more of the following:
– Flames and sparks shooting out of the top of the chimney – A roaring sound –
Vibration of the chimney
1. Keep your chimney clear of creosote build-up by cleaning your chimney
before each burn season, and as necessary (accumulations of 3 mm or more)
during the season. 2. Burn clean, well-seasoned wood only (seasoned at least
one year). Avoid wet or green wood. 3. Do not use the heater as an incinerator
or over-fire as it may ignite chimney fires. These are hot fires, such as when
burning household trash, cardboard, Christmas tree limbs, or even ordinary
fuel wood; (eg. with a full load on a hot bed of coals and with the air inlet
wide open)
In the event of a Chimney Fire
1. Prepare to evacuate to ensure everyone’s safety. Have a place outside
where everyone is to meet.
2. Close down the damper on stove.
3. Call local fire department. Have a fire extinguisher handy. Contact your
local fire authority for further information on how to handle a chimney fire.
It is most important that you have a clearly understood plan on how to handle
a chimney fire.
4. After the chimney fire is out, the chimney must be cleaned and checked for
stress and cracking before starting another fire. Also check combustibles
around chimney and the roof. This should be done by a certified
inspector/chimney sweep.
FP25LE, FP25LE_AR_AS_300424-32
5
100006366
Operation
WARNING: No alteration or modification of the combustion air control assembly
is permitted. Any tampering will void warranty and could be very hazardous.
Wood Selection
This heater is designed to burn natural wood only. Higher efficiency and lower
emissions generally result when burning air-dried seasoned hardwoods, as
compared to softwoods or too green or freshly cut hardwoods. Wood should be
properly air dried (seasoned) for six months or more. Wet or undried wood will
cause the fire to smoulder and produce large amounts of creosote. Wet wood
also produces very little heat and tends to go out often.
DO NOT BURN:
– Salt water wood – Treated wood – Wet or Green wood
– Coal/charcoal – *Garbage/Plastics – Solvents
- These materials contain chlorides which will rapidly destroy metal surfaces and void warranty.
Do not store/place wood or other combustibles within the required clearances surrounding the unit.
Do not burn anything but wood. Other fuel, e.g. charcoal, can produce large
amounts of carbon monoxide, a tasteless, odourless gas that can kill. Under no
circumstances should you attempt to barbecue in this heater.
How to Test Your Wood
Add a large piece of wood to the stove when it has a good, large bed of coals. It is dry if it is burning on more than one side within one minute. It is damp if it turns black and lights within three minutes. If it sizzles, hisses and blackens without igniting in five minutes it is soaked and should not be burnt.
Lighting the Fire
WARNING: Never use gasoline, gasoline-type lantern fuel, kerosene, charcoal lighter fluid, or similar liquids to start or `freshen up’ a fire in this heater. Keep all such liquids well away from the heater while in use.
- Adjust air control, located under the Ash Shelf. to “H” (high) position (pushed to the far left) and open door. 2) Place crumpled newspaper in the centre of the heater and criss-cross with several pieces of dry kindling. Add a few small pieces of dry wood on top. 3) Ignite the paper and close the door.
- After the fire has established itself, open the door and add a few small
logs. Close door. 5) Begin normal operation after a good coal base exists and
wood has charred.
Your Pacific Energy heater is designed for maximum overall efficiency at a moderate firing rate. Over firing is hazardous and a waste of fuel. Too slow a burn contributes to creosote buildup and lowers combustion efficiency.
Curing of the New Paint Finish
WARNING: Do not use grates or andirons to elevate the fuel. Burn directly on the firebricks. Replace broken or missing bricks. Failure to do so may create a hazardous condition.
When burning your stove for the first 2-3 times it is very important that the room be well ventilated. Open all windows and doors. Smoke and fumes caused by the curing process may cause discomfort to some individuals.
100006366
6
FP25LE_AS, FP25LE_AR_AS_300424-32
Normal Operation
- To refuel, adjust air control to “H” (high) position (pushed to the far left) and give the fire time to brighten. Open door slowly, this will prevent smoke from rolling out.
WARNING: Always keep loading door closed when burning, except as instructed during start-up. This heater is not designed for open door burning
-
Use wood of different shape, diameter and length (up to 450mm”). Load your wood endwise and try to place the logs so that air can flow between them. Always use dry wood.
-
Do not load fuel to a height or in such a manner that would be hazardous when opening the door..
-
Set air control to desired setting. If smoke pours down across the glass (waterfall effect), this indicates you have shut the control down too soon or you are using too low a setting. As every home’s heating needs vary (i.e. insulation, windows, climate, etc.), the proper setting can only be found by trial and error and should be noted for future burns.
-
For extended or overnight burns, unsplit logs are preferred. Remember to char the wood completely on “H” (high) setting before adjusting air control for overnight burn.
DO NOT OVER FIRE THIS HEATER: Attempts to achieve heat output rates that exceed heater design specifications can result in permanent damage to the heater and chimney.
Experience will give you the right settings for proper combustion and efficient burning. Remember, the air inlet setting is affected by variables such as type of wood, outside temperature, chimney size and weather conditions. With practice, you will become proficient in operating your heater and will obtain the performance for which it was designed.
Restarting after Overnight Burn
- Open door and rake hot embers towards the front of the heater. Add a couple of dry, split logs on top of embers, close door. 2) Adjust air control to “H” (high) position (pushed to the far left) and in just a few minutes, logs should begin burning. 3) After wood has charred, reset air control to desired setting. 4) When burning at a slow rate for extended periods, occasionally maintain a strong fire under supervision for a couple of hours to remove firebox and chimney deposits as well as any of the deposits on the glass.
WARNING: No alteration or modification of the combustion air control assembly is permitted. Any tampering will void warranty and could be very hazardous.
Proper Draft
- Draft is the force which moves air from the appliance up through the chimney. The amount of draft in your chimney depends on the length of the chimney, local geography, nearby obstructions and other factors. 2) Too much draft may cause excessive temperatures in the appliance. An uncontrollable burn or a glowing red stove part or chimney indicates excessive draft. 3) Inadequate draft may cause back puffing into the room and plugging of the chimney. Smoke leaking into the room through appliance and chimney connector joints indicates inadequate draft.
CAUTION: Unit hot while in operation. Parts of the appliance, especially the external surfaces, will be hot to touch when in operation. Keep children, clothing and furniture away. Contact may cause skins burns.
FP25LE, FP25LE_AR_AS_300424-32
7
100006366
Fig. # 1
Dimensions
[1425 mm] [1055 mm] [102 mm] [610 mm] [1150 mm] [883 mm] [269 mm] Unit and
standoffs only – Steel framing kit not shown.
Minimum Clearances
Fireplace Clearances and Dimensions Distance to combustible material from the
side/back standoffs and framing kit. Ceiling clearance – both in the chase and
in the room: from the base of the fireplace to the ceiling. Minimum distance
of adjacent wall to side of fireplace door. Minimum distance to (Max) 1.22m
deep side facing from fireplace door opening. Minimum width of floor
protection from side of door opening. Minimum depth of non-combustible ember
protector from the front of the fireplace. Minimum chimney height: minimum
total chimney height from fireplace bottom to below the chimney rain cap.
Recommended maximum chimney height (at sea level) from top of fireplace to
rain cap. Maximum unsupported chimney height.
0mm 2.13m
560mm 292mm 200mm 500mm
4.6m
10.7m 6.1m
100006366
8
FP25LE_AS, FP25LE_AR_AS_300424-32
Fireplace Installation
Fig. # 2
620mm
248mm
The top front framing must be installed as shown, Fig. # 3 with no wood
framing directly in front of the chimney system
WARNING: The fireplace must not be in contact with any insulation or loose
filling material. If you are insulating the chase, cover the insulation with
plasterboard or non-combustible panels. Maintain all proper clearances.
WARNING: Plasterboard materials are considered combustible and their thickness
must be accounted for in your framing dimensions.
The open volume inside the chase is required for heat management. Do Not build
a recess, shelves or cupboards in the area above this fireplace. Do not build
anything inside this Minimum chase area.
Do Not insulate the front portion of the chase above the unit.
The combustible enclosure must have 2 vents, each vent must be 100 high x
200mm wide (20,000mm² each vent). The bottom vent must be 50mm above the
floor, the top vent must be 85mm below the ceiling. and they must be made of a
heat resistant material.
A minimum 590mm deep x 1057mm wide x 6mm thick floor protector (compressed
board) should be used under the appliance base when installing the appliance
(see joint AS/ NZS 2918:2018 3.3.2). The Thermal resistivity of the floor
protector is 0.026m².K/W for 6mm thick compressed cement sheets.
1.48m
NOTE: The framing dimensions shown are the minimums. Framing dimensions will
need to be adjusted accordingly to accept plasterboard if used inside
enclosure.
Fig. # 3
[455mm] [455mm] [1.6m]
NON-COMBUSTIBLE NOGGIN
[610mm] [1.48m] [2.134m] Inside Enclosure, from base of the
unit.
FP25LE, FP25LE_AR_AS_300424-32
9
100006366
Each Kit Contains:
Item Part #
Description
Qty.
1 5049.9912 SCREW, TEKS #8 x 1/2″(13mm)
Pkg 40
2 7746
STUD, TOP/BOTTOM
2
56″(1.42m)L
3 9093.22
STUD, CNTR SUPPORT 5
1
SIDES, 15″(381mm)L
4 7747
FRAMING KIT LEG 3
3
1/2″(89mm)L
ASSEMBLY
· Lay out top/bottom studs (#2) and center studs (#3) on their sides on a
large flat surface.
· Using the screws provided (1), attach the framing kit legs(4) to the bottom
stud (2).
· Next, attach each center support(3) to the bottom stud(2) and then attach
the top stud(2) to the center supports(3).
INSTALLING THE UNIT INTO THE CHASE
· Push the Fireplace into place (Casing must be flush with the framing in the
front) and secure if required by local code.
· Place the Steel Framing Kit on top of the unit with the legs down Figure 5.
Ensure the front edge is flush with the Fireplace and with the chase framing.
It is very important to provide a flat surface to attach the outer
noncombustible board to.
· Attach the Framing kit securely to the chase’s framing using appropriate
fasteners.
Fig. # 5
Fig. # 4
2 1
4
100006366
10
FP25LE_AS, FP25LE_AR_AS_300424-32
Chimney Installation
Chimney and Connector
WARNING: INSTALL CHIMNEY AND ALL COMPONENTS OF CHIMNEY SYSTEM ACCORDING TO
CHIMNEY MANUFACTURER’S INSTRUCTIONS. Connect to a listed chimney complying
with the requirements of AS/NZS2918/2001 and a chimney suitable for use with
solid fuel that is lined and in good condition and meets local building codes.
The chimney flue size should be the same as the stove outlet for optimal
performance. Reducing or increasing the flue size may adversely affect stove
performance. Chimney flue exit is to be minimum 1000mm above roof and 600mm
above highest projection within 3000mm. The installation must meet all local
codes. Do not connect this unit to a chimney flue serving another appliance.
Minimum system height is 4600mm (measured from base of appliance).
Fig. #6
FP25LE, FP25LE_AR_AS_300424-32
11
100006366
Room Seal Flue Kit
Insulated Room Sealed Flue Kit
Fully Sealed 4m Flue Kit
Painted Insulated RSF from the heater Stainless Steel RSF outside the home
Optional Support Brace
N
1000
25
NOTE:
Flue Assembly
F
C
C
C L C
50
NOTE:
L C
Fully Sealed Flue Kit
Item
C
1000mm Room Sealed Flue (with Locking Band)
QTY
4
E Ceiling Ring
1
F Wind Cowl
1
Stainless Steel
G Room Sealed Flue Adapter
1
C 1000
N
E
25
Ceiling Ring
C 1000
C
25
1000
NOTE: C
G
100006366
Paint Finish: Stove Bright Metallic Black
12
FP25LE_AS, FP25LE_AR_AS_300424-32
Combustion Air
Intake or combustion air can be supplied to the fireplace in one of two ways.
Consult your local building codes before proceeding.
1. Outside Air Supply: WARNING: This must get its air from the outdoors and
be finished with an approved vent cap. The use of outside combustion air for
residential installations requires that the fireplace be secured to the
structure to prevent dislodging of the air duct. Check local building codes
for instructions on sealing the vent cap at the penetration point of the
building. The combustion air inlet ducts can not terminate in an attic space
or garage.
INSTALLATION:
Outside air may be drawn through either side or back of the unit by connecting
102mm rigid or flex pipe onto the outside air adapter opening provided on the
either side of the combustion air box. The fireplace comes with the outside
air adapter factory installed on the right side. You are able to switch this
with the cover plate on the left side if required Figure 7. We recommend
insulated flex when being installed in cold climates.
Use an approved 102mm inlet vent cap. Cut or drill a corresponding hole in the
closest exterior wall or in the floor anywhere inside the chase. Cover the
hole and install a 20GA wire mesh minimum, rodent screen and staple/nail in
place. Provide water protection as required by building code. Attach 102mm
flex pipe (not supplied) between the units adapter and the inlet vent. A
typical outside air connection is shown in Figure 8.
2. Room Air Supply -The fireplace can draw its air from the room through a
space between the surround panels or through air inlet ducts placed near the
floor in the chase
CAUTION: The living space around the heater must be well ventilated with good
air circulation. Anything that may cause a negative pressure can cause gases
or fumes to be pulled into the living area. During extremely cold weather, and
especially when burning at very slow rates, the upper parts of the exposed
chimney may ice up, partially blocking the flue gases. If blockage occurs,
flue gases may enter living space.
WARNING: This unit is not designed to be operated with the firing door open.
In addition to the obvious hazard of sparks landing on combustibles, an open
fire door will cause the heater to draw excess air from the living space and
possibly cause suffocation.
WARNING: THE COMBUSTION AIR INLET MUST BE AT LEAST 1.5m BELOW CHIMNEY OUTLET
AND MUST NEVER TERMINATE IN ATTIC SPACES.
Fig. # 7
Fig. # 8
Air Intake from side or rear
OUTSIDE AIR ADAPTER left or right mounting
FP25LE, FP25LE_AR_AS_300424-32
13
100006366
Blower Operation
For your protection against shock hazard, use only a properly grounded outlet that will accept a grounded plug
The FP25LE blowers must be connected to 240 VAC house hold electrical system.
Connect the blower circuit to a wall switch or fan speed controller.(not
supplied)
All electrical service should be performed by a certified/licensed
electrician.
The FP25 comes equiped with a power cord. Plug the power cord into an approved
outlet.
Electrical Supply
Circulating air blower electrical rating: 240V, 50 Hz. 1A.
For your protection against shock hazard, use only a properly grounded outlet
that will accept a three-pronged plug. Do not cut or remove the grounding.
All electrical connections to and within an appliance shall be in accordance
with the requirements of AS/NZS 3000, AS/NZS 3100 or ER 93 and the regulatory
authority as appropriate.
Fig. # 9
Electrical box
Fig. # 10
Temp Switch
Blowers
Neutral Line
From Power Cord
Ground Junction Box
100006366
14
FP25LE_AS, FP25LE_AR_AS_300424-32
Floor Protection
A minimum 875 x 450mm x 6mm thick floor protector (compressed board) should be
used in front of the enclosure base and be placed centrally in the 875mm
width. The Thermal resistivity of the floor protector is 0.026m².K/W for 6mm
thick compressed cement sheets.
Fig. # 11
Fireplace front
Hearth extension non-combustible finish material
The space between the fireplace and the hearth extension must be sealed with a non-combustible material such as sand – cement grout
Floor
FLOOR PROTECTOR This Fireplace requires Non-Combustible Ember Protection
extending from face of the unit out in front of the Door. This can be tile,
brick, slate, stone or metal. Minimum 20GA steel
Fig. # 12
Floor Protection
[450mm] [1.48m] Minimum Width – 1.48 m centered with door opening Minimum Overall Depth – 450mm
FP25LE, FP25LE_AR_AS_300424-32
15
100006366
Finishing The Chase
The front facing area of the FP25LE must be covered with non-combustible
cement board prior to applying any non-combustible finishing material.
Use the Cement Board manufacturer’s guidelines and suggested fasteners to
attach the cement board to the unit and studs. Finish the joints as per the
board manufacturer’s recommendations.
The cement board must cover from the floor to a height of 1.6m from the bottom
of the fireplace and 1.48m wide centered on the unit.
The front casing of the fireplace has a built in facing edge/stop. DO NOT
PLACE ANY CEMENT BOARD OR FINISHING MATERIALS INSIDE THIS EDGE. Failure to
comply may result in improper installation of panels, overheating of the
fireplace and blowers and may not be covered under Warranty.
The combustible enclosure must have 2 vents, each vent must be 100 high x
200mm wide (20,000mm² each vent). The bottom vent must be 50mm above the
floor, the top vent must be 85mm below the ceiling. and they must be made of a
heat resistant material.
Fig. # 13
NON-COMBUSTIBLE CEMENT BOARD REQUIRED IN THE HATCHED AREA.
Minimum 85mm
100mm x 200mm CHASE AIR INLET
FACING EDGE/STOP
Minimum 1.48m
MIN. 1.6m
100mm x 200mm CHASE AIR INLET
Minimum 50mm
VARIOUS LOCATIONS FOR CHASE AIR INLETS, CAN ALSO BE ON OTHER SIDE OF CHASE
100006366
16
FP25LE_AS, FP25LE_AR_AS_300424-32
Mantel and Finishing Clearances
DO NOT place any facing materials inside the facing edge/stop. This will
prevent proper airflow into the unit as well as preventing removal of the rear
surround to service the blowers.
Only non combustible materials can be used in the area;
· Extending from the outer edge of the door out 11 1/2″ [292mm], · Under the
door, down to the floor. · Above the Heat Exchanger’s air deflector up to a
minimum of 16″ [406mm].
Fig. # 14
NO COMBUSTIBLES FACING EDGE/STOP [406mm] Allowed in this area
[292mm] [292mm]
Mantel Clearances and Dimensions Minimum distance to the underside of the
Mantel (max 305mm deep) from the top of the Heat Exchanger Air Deflector.
Minimum distance to the adjacent wall from the side of the fireplace door.
Minimum distance to the Mantel side facing (Max 102mm deep) from the side of
the fireplace door.
Raised hearth must be completely constructed of non-combustible materials
Minimum width of floor protection from side of door opening. Minimum depth of
non-combustible ember protector: from the front of the fireplace.
406mm 560mm 292mm
200mm 420mm
FP25LE, FP25LE_AR_AS_300424-32
17
100006366
Firebrick Installation
This package contains 18 full-size firebricks, as well as 5 various cut-size
bricks. With the heater in the upright position, install firebricks as
follows: – Place 6 full-size firebricks and bricks C & D on the bottom of the
heater first in the pattern shown below. – Next, install the rear firebricks,
4 full-size, two on each side of the baffle tube. – Then place 1 brick C in
the back left corner as shown below. – Lastly, install 4 full-size firebricks
and brick B as shown on each side of the firebox.
B C
D A
ITEM/ ARTICLE
A 9″ X 4 1/2″ X 1 1/4″ B 4 1/2″ X 4 1/2″ X 1 1/4″ C 2 1/4″ X 9″ X 1 1/4″ D 2
1/4″ X 4 1/2″ X 1 1/4″
DIMENSIONS
(230 mm x 115 mm x 32 mm) (115 mm x 115 mm x 32 mm) (57 mm x 230 mm x 32 mm)
(57 mm x 115mm x 32 mm)
B
PART NUMBER
5096.99 7847 7847.3 7847.1
100006366
18
FP25LE_AS, FP25LE_AR_AS_300424-32
Cleaning/Maintenance
Ash Removal
Whenever ashes get above 75mm deep in your firebox, and when the fire has burned WARNING: DO NOT OPERATE
down and cooled, remove excess ashes. Leave an ash bed approximately 30mm WITH BAFFLE ASSEMBLY OR
deep on the firebox bottom to help maintain a hot charcoal bed.
INSULATION REMOVED.
Disposal of Ashes
Ashes should be placed in a metal container with a tight fitting lid. The closed container of ashes should be placed on a non-combustible floor or on the ground, well away from all combustible materials, pending final disposal.
If the ashes are disposed of by burial in soil or otherwise locally dispersed,
they should be retained in the closed container until all cinders have
thoroughly cooled. Other waste should not be placed in this container!
Baffle Assembly Removal
Remove retaining pin at the back top of the firebox, just under the baffle. Lift baffle up slightly and lift one of the Side Brick Rails up off its retaining pins and remove the Rail. Lift the baffle up and pull forward to disconnect it from the supply tube. Tilt baffle sideways to drop down and remove from firebox.
Re-install baffle assembly and insulation by reversing the order.
Chimney Liner
It is recommended to inspect the liner and connector cleaned annually or more frequently if required.
monthly and to have the
liner
WARNING: Cover the opening in the top of the rear upflow tube
WARNING: DO NOT use a vacuum to clean above the baffle while installed. you when cleaning the chimney liner.
may accidentally damage or remove the Ceramic Baffle Insulation.
If debris gets into the tube it can
cause the tube to prematurely burn
Sweep/Clean chimney with baffle installed or be sure to plug the top of the baffle tube in the back of the firebox before sweeping or cleaning. Failure to prevent ash
out.
or soot from falling into the baffle tube will cause incorrect operation and will lead
to premature burn out of the tube or baffle. The baffle should be removed from
the fireplace to fully inspect the chimney liner.
Blower Maintenance
The blower requires occasional cleaning to prevent buildup of dust and hair. More frequent cleaning may be required if conditions are dusty or pets are present. This service is best performed by a qualified service technician.
The blowers use sealed bearings and do not require service lubrication.
FP25LE, FP25LE_AR_AS_300424-32
19
100006366
Blower Replacement
1. Remove the front trim by lifting and pulling away from the unit. Remove
the four screws securing the back plate to the brackets and set them aside
carefully to avoid damage.
2. Remove the Back plate mounting bracket by removing the two screws securing
the bracket to the side casing of the unit. Fig. #15 (may require the unit to
be pulled out slightly.)
Fig. # 15
Fig. # 16 3. With a 3/8″ wrench, loosen the two bolts securing the blower mounting bracket to the unit. Fig. #16
4. Disconnect the two wires leading to the blower motor.
5. Pull the blower mounting bracket bottom out first and then lift the blower
up and back to remove from the bolts. If replacing the right side blower, then
disconnect the two wires leading to the thermo-switch at this time as well..
6. Remove the three screws securing the blower to the mounting bracket and replace the blower. Fig. #17
Fig. # 17
SCREWS
7. Reverse all previous steps to reinstall the new blower.
BOLTS
100006366
20
FP25LE_AS, FP25LE_AR_AS_300424-32
Option: Remote Heat Duct Kit Installation
This Fireplace is designed to use the optional Remote Heat Transfer Kit (Part
11490004). This kit allows heat to be ducted from the casing of the
fireplace (using listed B-Vent) to the room or other parts of the home. One or
two Remote Heat Kits may be installed on the fireplace. The Remote Heat Kit
includes a blower that will require an 240V electrical connection.
The Remote Heat Kit requires 6″(153mm) Listed/Approved gas venting. This
allows reduced clearances in the wall spaces. Follow the clearances and
applicible installation guidelines in the vent manufacturers instructions,
this includes the use of firestops when passing through walls or floor spaces
WARNING: THE CHASE ENCLOSURE MUST HAVE A MINIMUM (194 cm2²) ROOM AIR INLET FOR
EACH REMOTE HEAT KIT INSTALLED ON THE FIREPLACE. The inlets can be combined,
but it must be 388cm2 or greater. No extra chase air inlet is required if not
installing a remote heat kit.
FP25LE, FP25LE_AR_AS_300424-32
21
100006366
Heat Duct Replacement Parts
ITEM DESCRIPTION
PART NUMBER
ITEM DESCRIPTION
PART NUMBER
1 DUCT ADAPTER …………………………………………………………..WODC.9128 9 BLOWER…………………………………………………………………………… 80002045 2 OUTLET GRILL ………………………………………………………………….. 5096.854 10 WIRE PIG TAIL …………………………………………………………..WODC.50625 3 BACKFLOW DAMPER………………………………………………..WODC.7940 11 STRAIN RELIEF………………………………………………………………….. 5033.505 4 TRANSITION BOOT…………………………………………………………. 5096.853 12 RHEOSTAT KIT…………………………………………………………………….5025.001 5 BLOWER CASING FACE PLATE ……………………………………………. 9144 13 JUNCTION BOX ………………………………………………………………. 5024.408 6 BLOWER FAN BRACKET…………………………………………………………. 9146 14 INLET GRILL …………………………………………………………………………5096.851 7 ELECTRICAL CONNECTION COVER ……………………………….9144.5 8 REMOTE BLOWER BOX ……………………………………………..WODC.9141
1 4
5 9
2 3
6 7
8
6
11 10
100006366
22
FP25LE_AS, FP25LE_AR_AS_300424-32
Firestop A
Ducting Options
B
A
A
Chimney not shown for clarity
Firestop
A
Fig. # 18
The maximum effective length run for each Remote Heat Kit is(6m). The amount
of heat from this kit is affected by the length and number of bends. To
maximize the performance the length and number of bends should be kept to a
minimum.
A. (305mm) from the CEILING or SIDE WALLS B. (914mm) from the FLOOR
FP25LE, FP25LE_AR_AS_300424-32
23
100006366
Duct Installation 1. Remove the knockout panel from the top of the unit for
each Remote Heat Kit you are installing Fig #19.
2. Cut and remove the insulation directly below the opening, down to the next
opening Fig #20.
Fig. # 19
REMOVE THESE KNOCKOUT PANELS AS NEEDED
Fig. # 20
Knock out panels.
Panel with insulation removed.
3. Place the Backflow Damper into the top of the unit Fig #21. Ensure that the flap in the assembly is free to move. (Flap should be in the normally closed position with the blower off)
4. Attach the Duct Adapter to the top of the fireplace over top of the Backflow Damper Fig #22. Using 4 screws secure both pieces to the Fireplace’s outer casing.
Fig. # 21
Fig. # 22
Backflow damper installed
Backflow damper.
100006366
Duct adapter.
24
FP25LE_AS, FP25LE_AR_AS_300424-32
5. Locate the Remote Blower Assembly in the desired wall location, following the specifications listed below and secure to the framing using the mounting tabs on the casing.
Fig. # 23
BLOWER ASSEMBLY
THE REMOTE HEAT KIT BLOWER ASSEMBLY MUST BE INSTALLED SO THAT ANY EDGE OF THE BLOWER CASING/ OUTLET GRILL IS A MINIMUM OF: – (305mm) FROM THE CEILING OR ADJUST WALLS – (914mm) FROM THE FLOOR
6. Attach the (254) X (83mm) Transition Boot to the Remote Blower Assembly and seal with aluminium duct tape. Run 6″(153mm) diameter approved flexible or ridged gas vent pipe (vent pipe is not include with this kit) between the blower and the fireplace. Fasten in place with screws and seal with aluminium foil tape.
7. Connect the wiring as per the directions and wiring diagram in “Remote Heat Kit Wiring” on page 26.
TRANSITION BOOT
Blower installation.
B-VENT HEAT DUCT
8. Locate the make-up air inlet as per the owner’s manual in a desired location in the chase wall.
9. Drywall and facing material must not cover the opening in the blower assembly. Remove the Face Plate.Cut the drywall so the egdes butt up against the outside of the blower casing edges Fig #23, top, bottom and sides.
10. Re-install the Face Plate Fig #25 and then attach the Outlet grill(s) over the outlet(s) Face Plate using the screws provided by aligning the screws for the outlet grill with the holes in the casing face plate.
11. Install the Inlet grill(s) over the chase inlet opening(s) after any decorative finish has been applied.
Fig. # 24
Blower Casing Egdes
Fig. # 25
Face Plate
Blower Casing Egdes Blower details.
FP25LE, FP25LE_AR_AS_300424-32
Outlet Grill Mounting Holes
Grill mounting holes.
25
100006366
Remote Heat Kit Wiring
WARNING: ALL ELECTRICAL WIRING MUST BE DONE BY A QUALIFIED ELECTRICIAN.
NOTE: For best results, the remote heat kit blower/s should be wired to a
separate switch or speed controller in the room that the outlet is in. If the
outlet(s) are mounted in the chase they could be wired on the same switch or
speed controller as the Fireplace Blower.
All electrical connections to and within an appliance shall be in accordance
with the requirements of AS/NZS 3000, AS/ NZS 3100 or ER 93 and the regulatory
authority as appropriate.
The Remote Heat Kit blower’s electrical rating: 240V, 50HZ, 1 amp. For your
protection against shock hazard, use only a properly grounded electrical
supply.
This kit includes a junction box, rheostat and cover plate. The junction box
should be mounted in a convenient location away from the fireplace.
Use only copper conductors
Blower Ground
WALL SWITCH/ SPEED CONTROLLER
Neutral (white)
Terminal Strip
Remote heat kit wiring diagram.
Hot (black)
100006366
26
FP25LE_AS, FP25LE_AR_AS_300424-32
Problem
Excessive Creosote Buildup
Glass is Dirty Low Heat Output Won’t Burn Overnight Stove Won’t Burn
Troubleshooting
Cause
- Wood is too wet
- Turning down air control too soon
- Draft too low
- See 1, 2, and 3 above 2) Door Gasket leakage
- Wood may be wet 2) Fire too small
- Air control set too high 2) Not enough wood 1) Combustion air supply
is blocked 2) Draft too low
Cure
– Use dry wood(recommended moisture level <20%)
– Do not turn down until: a) there is a good bed of coals b) the wood is
charred
– Chimney plugged or restricted, check flue – Improper chimney height and/or
diameter – Provide outside air for combustion – Check draft in chimney and
system, alter as needed.
– Replace gasket – Check door latch
– Check wood and use drier wood if required.
– Build a larger fire – Open draft control to increase burn rate.
– Set control lower
– Unsplit wood is preferred for overnight burns
– Check outside air supply for obstructions (see Combustion Air section)
– Chimney plugged or restricted Inspect and clean
– Chimney oversized or otherwise unsuitable Consult Dealer
FP25LE, FP25LE_AR_AS_300424-32
27
100006366
Parts List
ITEM DESCRIPTION
PART NUMBER ITEM DESCRIPTION
PART NUMBER
1 Quadrant 2 Blower Assembly, LHS
Blower only, LHS 3 Blower Assembly, RHS
Blower only, RHS 3a Thermoswitch 4 Door Gasket, 3/4″ Rope 5 Glass Retainer 6
Glass, NEO 2.5 (c/w Tape) 7 Door Casting
Arch Door Casting (not shown) 8 Door Handle Assembly
Door Complete w gasket and glass Arch Door Complete w/ gasket and glass
7953
9 Baffle Assembly, NEO 2.5
80000247
80002314 10 Insulation, NEO 2.5, Baffle
80001395
5024.53 10 Brick Rail Kit
80000251
80002313 11 Door Catch
80000226
5024.54 12 Backing Plate, FP25
11120001
5027.2
13 Front Trim, FP25, Met Black
11250005
80002439 Front Trim, FP25, Stainless Steel
11250006
80000246 Front Trim, FP25 Arch, Met Black
11250007
80000240 Front Trim, FP25 Arch, Stainless Steel
11250008
80000253 14 Firebrick Set
80000248
80000920 15 Framing Kit
80000801
80001754 16 Flame Shield
80002441
80000253 80000166
All parts may be ordered from your nearest Pacific Energy dealer. Contact Pacific Energy for the location
of the dealer nearest you.
15
9
2 11
10
16
1
4
5 6 7 8
13 14
3a 3
12
100006366
28
FP25LE_AS, FP25LE_AR_AS_300424-32
Rating Label
1. Remove the Front Trim by lifting up and pulling away from the unit. Remove
the four screws securing the back surround to the brackets and set the
surround aside carefully to avoid damage. 2. The rating label plate is located
on the left side, in the bottom casing support, between the side casing and
the heat shield. It is attached to the heat shield by a stainless steel cable.
Figure 26. 3. To access/view the rating label, gently pull the cable attached
to the rating label plate and lift the plate free of the slot. Figure 27.
Fig. # 26
Fig. # 27
FP25LE, FP25LE_AR_AS_300424-32
29
100006366
FP25 A
ZERO CLEARANCE
Tested by: AUSTRALIAN SOLID FUEL TESTING 3 GARDEN ST., MORWELL, VICTORIA
ASFT23065 26 SEPTEMBER 2023
WHEN TESTED IN ACCORDANCE WITH: AS/NZS 4012:2014 & AS/NZS4013:2014
MAXIMUM AVERAGE HEAT OUTPUT BURNING HARDWOOD 9.2 kW
OVERALL AVERAGE EFFICIENCY BURNING HARDWOOD 72%
PARTICULATE EMISSIONS FACTOR – 1.0g/kg
CATALYTIC COMBUSTOR – NO
Distributed by: PIVOT STOVES AND HEATING CO 234-238 MOORABOOL STREET, GEELONG,
VIC 3220
pivotstove.com.au
171023
100006424
100006366
30
FP25LE_AS, FP25LE_AR_AS_300424-32
FP25LE, FP25LE_AR_AS_300424-32
31
100006366
© 2023 Copyright Pacific Energy Fireplace Products LTD. Reproduction,
adaptation, or translation without prior written permission is prohibited
except as allowed under the copyright laws.
For technical support, please contact your retailer Web site:
www.pacificenergy.net
2975 Allenby Rd., Duncan, BC V9L 6V8
Printed in Canada
References
- Wood Stoves, Wood Fireplaces, Wood Inserts, Gas Stoves, Gas Fireplaces, Gas Inserts | Pacific Energy