PACIFIC ENERGY SUMMIT LE Wood Stove Instruction Manual

June 16, 2024
Pacific Energy

SUMMIT LE Wood Stove

Product Information

Specifications

  • Model: SUMMIT LE / SUMMIT CLASSIC LE

  • Serial #: [Serial Number]

  • Tested and Listed to CAN/ULC S627 AND UL 1482

  • Meets the Environmental Protection Agency’s 2020 Particulate
    Emission Standards (Crib Wood)

  • BTU Output Range: 16,102 to 41,275 Btu/hr

  • Emission Rate: 1.8 g/hr

Safety Notice

If this stove is not properly installed, a house fire may
result. For your safety, follow the installation instructions.
Contact local building or fire officials about restrictions and
installation inspection requirements in your area.

Operating and Installation Instructions

This manual describes the installation and operation of the
SUMMIT LE or SSUMMIT CLASSIC LE Freestanding wood heater. This
heater meets the 2020 U.S. Environmental Protection Agency’s crib
wood emission limits for wood heaters sold after May 15, 2015.
Under specific test conditions, this heater has been shown to
deliver heat at rates ranging from 16,102 to 41,275 Btu/hr.

NOTE: WE STRONGLY RECOMMEND THAT SMOKE AND CARBON MONOXIDE
DETECTORS BE INSTALLED IN THE AREA WHERE THE HEATER IS TO BE
INSTALLED. If smoke detectors have been previously installed, you
may notice that they are operating more frequently. This may be due
to curing of stove paint or fumes caused by accidentally leaving
the fire door open. Do not disconnect the detectors.

SAFETY NOTICE: If this stove is not properly installed, a house
fire may result. For your safety, follow the installation
instructions. Contact local building or fire officials about
restrictions and installation inspection requirements in your area.
Please read this entire manual before you install and use your new
room heater. Failure to follow instructions may result in property
damage, bodily injury, or even death.

Baffle Removal

[Baffle Removal instructions]

Dimensions

[Dimensions of the product]

Assembly

[Assembly instructions]

Hot Glass Warning

WARNING: HOT GLASS WILL CAUSE BURNS. DO NOT
TOUCH GLASS UNTIL COOLED. NEVER ALLOW CHILDREN TO TOUCH GLASS.

Table of Contents

[Table of Contents]

Rating Label

This manual describes the installation and operation of the
Pacific Energy, SUMMIT LE / SUMMIT CLASSIC LE Freestanding wood
heater. Model SUMMIT LE / SUMMIT CLASSIC LE: 1.8 g/hr.

Experience will give you the right settings for proper
combustion and efficient burning. Remember the correct air inlet
setting is affected by variables such as type of wood, outside
temperature, chimney size, and weather conditions. With practice,
you will become proficient in operating your heater and will obtain
the performance for which it was designed.

FAQ

Q: What is the emission rate of the SUMMIT LE / SUMMIT CLASSIC

LE wood heater?

A: The emission rate is 1.8 g/hr.

Q: What is the BTU output range of the wood heater?

A: The BTU output ranges from 16,102 to 41,275 Btu/hr.

Q: Are smoke and carbon monoxide detectors recommended?

A: Yes, it is strongly recommended to install smoke and carbon
monoxide detectors in the area where the heater is installed.

IMPORTANT: THESE INSTRUCTIONS ARE TO REMAIN WITH THE HOMEOWNER

SERIAL #

SAFETY NOTICE
If this stove is not properly installed, a house fire may result. For your safety, follow the installation instructions. Contact local building or fire officials about restrictions and installation inspection requirements in your area.

OPERATING AND INSTALLATION INSTRUCTIONS

TESTED and LISTED to CAN/ULC S627 AND UL 1482

Meets the Environmental Protection Agency’s 2020 Particulate Emission Standards (Crib Wood).

MODEL(s): SUMMIT LE, SUMMIT CLASSIC LE

310119-28

Visit www.pacificenergy.net for the most recent version of this manual
SUMMIT LE / SUMMIT CLASSIC LE

100000302

Table of Contents

Contents
Table of Contents ……………………………………………………………. 2 Rating Label …………………………………………………………………… 3
Efficiency and BTU Output…………………………………………. 3 Safety ……………………………………………………………………………. 4
Chimney Smoke and Creosote Formation……………………. 4 Chimney Fires ………………………………………………………….. 4 To Avoid a Chimney Fire…………………………………………….. 5 In Case of a Chimney Fire ………………………………………….. 5 Curing of the Paint Finish…………………………………………… 5 Operation ……………………………………………………………………….. 6 Wood Selection ………………………………………………………… 6 DO NOT BURN :……………………………………………………….. 6 How to Test Your Wood……………………………………………… 6 Lighting a fire……………………………………………………………. 7 Normal Operation……………………………………………………… 7 Restarting After Extended or Overnight Burns ……………… 8 Proper Draft……………………………………………………………… 8 Ash Removal ……………………………………………………………. 8 Ash Cleanout system (optional): ………………………………… 8 Disposal of Ashes……………………………………………………… 8 Maintenance …………………………………………………………………… 9 Maintenance Checks ……………………………………………………… 10 Weekly:………………………………………………………………….. 10 Monthly …………………………………………………………………. 10 When Cleaning the Chimney System:………………………… 10 Blower: ………………………………………………………………….. 10 Baffle: ……………………………………………………………………. 10

Baffle Removal ……………………………………………………………… 10 Dimensions …………………………………………………………………… 11 Assembly ……………………………………………………………………… 12
Crate Removal ……………………………………………………….. 12 Optional Ash Cleanout System -(Install first) ………………. 12 Pedestal Ash Pan ……………………………………………………. 12 Leg Ash Pan …………………………………………………………… 12 Legs………………………………………………………………………. 12 Floor Protector ……………………………………………………………… 13 Residential Installation ……………………………………………………. 14 Clearances: ……………………………………………………………. 14 Chimney and Connector ………………………………………….. 15 When using a Double-Wall Connector ……………………….. 15 When using a Single-Wall (smoke pipe) Connector ……… 15 Installation Procedure ……………………………………………… 16 Combustion Air ……………………………………………………………… 16 Through Wall Installations ……………………………………….. 19 Mobile Home Installation ………………………………………………… 21 Clearances …………………………………………………………….. 21 Optional Blower …………………………………………………………….. 22 Blower Operation ……………………………………………………. 22 Trouble Shooting …………………………………………………………… 23 Replacement Parts – SUMMIT LE ……………………………………. 24 Replacement Parts – SUMMIT CLASSIC LE ……………………… 25 Firebricks ……………………………………………………………………… 26 Firebrick Installation ………………………………………………………. 27

! WARNING

HOT GLASS WILL CAUSE BURNS.
DO NOT TOUCH GLASS UNTIL COOLED.
NEVER ALLOW CHILDREN TO TOUCH GLASS.
PLEASE SAVE THESE INSTRUCTIONS
This manual describes the installation and operation of the SUMMIT LE or SSUMMIT CLASSIC LE Freestanding wood heater. This heater meets the 2020 U.S. Environmental Protection Agency’s crib wood emission limits for wood heaters sold after May 15, 2015. Under specific test conditions this heater has been shown to deliver heat at rates ranging from 16,102 to 41,275 Btu/hr.
NOTE: WE STRONGLY RECOMMEND THAT SMOKE AND CARBON MONOXIDE DETECTORS BE INSTALLED IN THE AREA WHERE THE HEATER IS TO BE INSTALLED. If smoke detectors have been previously installed, you may notice that they are operating more frequently. This may be due to curing of stove paint or fumes caused by accidentally leaving the fire door open. Do not disconnect the detectors.
SAFETY NOTICE: If this stove is not properly installed, a house fire may result. For your safety, follow the installation instructions. Contact local building or fire officials about restrictions and installation inspection requirements in you area. Please read this entire manual before you install and use your new room heater. Failure to follow instructions may result in property damage, bodily injury, or even death.

100000302

2

SUMMIT-LE_310119-28

Figure 1: Rating Label, SUMMIT LE .

Rating Label
PLEASE SAVE THESE INSTRUCTIONS
This manual describes the installation and operation of the Pacific Energy, SUMMIT LE / SUMMIT CLASSIC LE Freestanding wood heater.
Model SUMMIT LE / SUMMIT CLASSIC LE: 1.8 g/hr.

Experience will give you the right settings for proper combustion and efficient burning. Remember the correct air inlet setting is affected by variables such as type of wood, outside temperature, chimney size and weather conditions. With practice, you will become proficient in operating your heater and will obtain the performance for which it was designed.

SUMMIT-LE_310119-28

CERTIFIED FOR CANADA AND U.S.A. – MODEL / MODÈLE: SUMMIT LE SUMMIT CLASSIC LE ALDERLEA T6 LE

LISTED ROOM HEATER, SOLID FUEL TYPE. ALSO FOR USE IN MOBILE HOMES CERTIFIED TO / CERTIFIÉ POUR: CAN/ULC S627-00 / UL 1482-2011

DO NOT REMOVE THIS LABEL

SN#

Refer to Intertek’s Directory of Building Products for detailed information

RESIDENTIAL INSTALLATION

C#4001507
· INSTALL AND USE IN ACCORDANCE WITH THE MANUFACTURER’S INSTALLATION AND OPERATING INSTRUCTIONS.
· CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS, INSTALLATION PERMIT AND INSPECTION IN YOUR AREA.
· DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE. · USE 6 INCH / 150MM DIAMETER MINIMUM 24 MSG BLACK OR LISTED CONNECTOR. · CAN BE CONNECTED TO A LINED MASONRY CHIMNEY SUITABLE FOR USE WITH SOLID FUELS. · DO NOT OBSTRUCT THE SPACE BENEATH THE HEATER. · SEE LOCAL BUILDING CODE AND MANUFACTURER’S INSTRUCTIONS FOR PRECAUTIONS
REQUIRED WHEN PASSING A CHIMNEY THROUGH A COMBUSTIBLE WALL OR CEILING. · DO NOT PASS A CHIMNEY CONNECTOR THROUGH A COMBUSTIBLE WALL OR CEILING. · MINIMUM CLEARANCE BETWEEN SINGLE WALL CHIMNEY CONNECTOR AND COMBUSTIBLE
MATERIALS-18INCHES/455MM. CLEARANCE MAY BE REDUCED BY THE USE OF LISTED PIPE SHIELDS, WALL PROTECTORS OR OTHER MEANS APPROVED BY LOCAL BUILDING OR FIRE OFFICIALS. · COMPONENTS REQUIRED FOR MOBILE HOME AND ALCOVE INSTALLATION: OUTSIDE AIR KIT. · BOTH CHIMNEY SYSTEM AND CONNECTOR MUST BE LISTED TO: IN CANADA – ULC S-641 LISTED CONNECTOR AND ULC-S-629 LISTED CHIMNEY IN USA – UL-103 HT LISTED CONNECTOR AND CHIMNEY · USE COMPONENTS SPECIFIED IN PACIFIC ENERGY INSTALLATION INSTRUCTIONS. · APPLIANCE MUST BE INSTALLED WITH PEDESTAL OR LEG KIT ATTACHED. · OPTIONAL COMPONENTS – FAN KIT, FAN ELECTRICAL RATING: 115V, 60HZ, 1.0 AMP. DO NOT ROUTE POWER CORD BENEATH HEATER. · CAUTION: RISK OF EXCESSIVE TEMPERATURES – KEEP ASH DUMP CLOSED DURING FIRING OF THE HEATER. · OPERATE ONLY WITH FEED DOOR CLOSED. OPEN TO FEED FIRE ONLY. · KEEP FURNISHINGS AND OTHER COMBUSTIBLE MATERIALS WELL AWAY FROM HEATER. · REPLACE GLASS ONLY WITH CERAMIC GLASS. HORIZONTAL CONNECTOR NOT PERMITTED IN MOBILE HOMES

  • AS TESTED – PIPE SHIELD MAY BE REQUIRED BY LOCAL AUTHORITIES. ** COMBUSTIBLE ALCOVE SIZE:
    DEPTH – 3 FT. / .91 M MAX., HEIGHT 7 FT. / 2.1 M MIN., · COMBUSTIBLE FLOOR MUST BE PROTECTED BY A CONTINUOUS NON-COMBUSTIBLE MATERIAL
    EXTENDED TO THE FRONT, SIDES AND BACK AS INDICATED. · THIS WOOD HEATER NEEDS PERIODIC INSPECTION AND REPAIR FOR PROPER OPERATION. –
    CONSULT THE OWNER’S MANUAL FOR FURTHER INFORMATION. · IT IS AGAINST FEDERAL REGULATIONS TO OPERATE THIS WOOD HEATER IN A MANNER
    INCONSISTANT WITH THE OPERATING INSTRUCTIONS IN THE OWNER’S MANUAL
    1.8 g/hr U.S. ENVIRONMENTAL PROTECTION AGENCY.
    Certified to comply with 2020 CRIB WOOD PARTICULATE EMISSION STANDARDS, using Method 28R// Certifié conforme aux normes sur les

MUR ADJACENT ADJACENT WALL

MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS/ DÉGAGEMENTS MINIMALES AUX
MATÉRIAUX COMBUSTIBLES
A. SIDEWALL TO UNIT/ MUR DE CÔTE / APPAREIL
B. BACKWALL TO UNIT/ MUR DE FOND / APPAREIL C. CORNER TO UNIT/ COIN / APPAREIL D. SIDEWALL TO CONNECTOR/ MUR DE CÔTE / RACCORD E. BACKWALL TO CONNECTOR/ MUR DE FOND / RACCORD F. CORNER TO CONNECTOR/ COIN / RACCORD
MUR ARRIERE BACK WALL

B

E

A

MUR COTE SIDE WALL

D

MUR ADJACENT ADJACENT WALL
C
F

USING SINGLE WALL CONNECTOR/ · INSTALLEZ ET UTILISEZ SELON LES INSTRUCTIONS D’INSTALLATION ET D’OPÉRATION FOURNI AVEC L’APPAREIL..

INSTALLATION RÉSIDENTIELLE UTILISANT · CONTACTEZ LES OFFICIELS DE LA CONSTRUCTION OU DE SERVICE D’INCENDIE POUR DES INFORMATIONS QUANT AUX

UN RACCORD DE MUR SIMPLE

RESTRICTIONS. PERMIS D’INSTALLATION ET INSPECTIONS DANS VOTRE RÉGION.

A. B. C. SUMMIT D.

14 in. / 356 mm 9 in. / 229 mm 6 in. / 152 mm
24 in. / 610 mm

· NE RELIEZ PAS CET APPAREIL À UN CONDUIT DE CHEMINÉE DESSERVANT DÉJÀ UN AUTRE APPAREIL . · UTILISEZ UN RACCORDEMENT NOIR OU CLASSÉ DE 24 MSG ET AVEC UN DIAMÈTRE D’AU MOINS 6 POUCES / 150 mm. · PEUT ÊTRE CONNECTÉ À UNE CHEMINÉE DE MAÇONNERIE ALIGNÉE PRÊTE À L’EMPLOI AVEC DES COMBUSTIBLES
SOLIDES. · N’OBSTRUEZ PAS L’ESPACE SOUS LE CAISSON DU POÊLE · CONSULTEZ LE CODE LOCAL DE CONSTRUCTION ET LES INSTRUCTIONS DU FABRICANT QUANT AUX PRÉCAUTIONS À

E.

*14.5 in. / 368 mm

PRENDRE LORSQUE VOUS FAITES PASSER UNE CHEMINÉE À TRAVERS D’UN MUR OU D’UN PLAFOND COMPOSÉS DE MATÉ-

F.

*16.9 in. / 429 mm

RIAUX COMBUSTIBLES.

ALDERLEA T6

· NE FAITES PAS PASSER UN RACCORDEMENT DE CHEMINÉE À TRAVERS D’UN MUR OU D’UN PLAFOND COMPOSÉS DE MATÉ-

D.

25.6 in. / 650 mm

RIAUX

E.

*14.6 in. / 371 mm

· DÉGAGEMENT MINIMAL ENTRE UN RACCORDEMENT DE CHEMINÉE À UN MUR SIMPLE ET TOUT MATÉRIEL COMBUSTIBLE

F.

*17.1 in. / 435 mm

– 18 POUCES / 455 mm. CE DÉGAGEMENT PEUT ÊTRE RÉDUIT EN UTILISANT DES PROTECTEURS DE TUYAUX CLASSÉS,

PROTECTEURS DE MUR OU AUTRES MOYENS APPROUVÉS PAR LES OFFICIELS DE LA CONSTRUCTION OU DU SERVICE

RESIDENTIAL INSTALLATION USING DOUBLE WALL CONNECTOR /
INSTALLATION RÉSIDENTIELLE AVEC DÉGAGEMENT MINIMAL, UTILISANT UN
RACCORD DE MUR DOUBLE

D’INCENDIE DE VOTRE RÉGION. CONNECTEUR HORIZONTAL NON PERMIS DANS MAISONS MOBILES · L’APPARIEL DOIT COMPORTER UN ENSEMBLE POUR PIEDSTABLE OU SUR PATTES. · PIÈCES REQUISES POUR INSTALLATION EN MAISON MOBILE OU EN ALCÔVE: NÉCESSAIRE D’APPROVISIONNEMENT D’AIR EXTÉRIEUR ET L’UN DES RACCORDS SUIVANTS: EN COMBINAISON AVEC L’UN DES SYSTÈMES DE CHEMINÉE COMPATIBLES SUIVANTS:

A.

13 in. / 330 mm

AU CANADA – LE ULC S-641 CONNECTEUR ENUMERES ET ULC-S-629 ONT ENUMERE CHEMINEE

B.

7.5 in. / 191 mm

· PIÈCES EN OPTION – NÉCESSAIRES DE SOUFFLERIE, INDICES ÉLECTRIQUES DE SOUFFLERIE: 115V, 60HZ, 1.0 AMP. LE FIL

C.

5 in. / 127 mm

SUMMIT

D.

23 in. / 584 mm

E.

13 in. / 330 mm

F.

15.9 in. / 403 mm

ALDERLEA T6

D.

24.6 in. / 612 mm

E.

13.1 in. / 333 mm

ÉLECTRIQUE NE DOIT PAS ÊTRE PLACÉ SOUS LE POÈTE. LE FIL ÉLECTRIQUE NE DOIT PAS ÊTRE PLACÉ SOUS LE POÊLE · ATTENTION: RISQUE DE TEMPÉRATURES EXCESSIVES – GARDES LE TIROIR DE CENDRES FERMÉ PENDANT L’ALLUMAGE DU POÈTE. · OPÉREZ SEULEMENT LORSQUE LA PORTE D’ALIMENTATION EST FERMÉE. · OUVREZ SEULEMENT POUR ALIMENTER LE FEU. · GARDEZ LES MEUBLES ET AUTRES MATÉRIAUX COMBUSTIBLES BIEN ÉLOIGNÉS DU POÊLE. · REMPLACES LA VITRE AVEC UNIQUEMENT DE LA VITRE CÉRAMIQUE.

  • TEL QUO ÉPROUVÉ UN PROTECTEUR DE TUYAU PEUT ÊTRE REQUIS PAR LES AUTORITÉS LOCALES ** DIMENSION D’ALCOVE COMBUSTIBLE: PROFONDEUR – 3 PIEDS / .91M, HAUTEUR 7 PIEDS/2.1M, LARGEUR 4 PIEDS/1.2M

F.

16.1 in. / 410 mm

MINIMUM.

LE PLANCHER COMBUSTIBLE DOIT ÊTRE PROTÉGÉ PAR UN MATÉRIEL NON-COMBUSTIBLE TOUT D’UNE PIÈCE QUI DOIT

* ALCOVE INSTALLATION USING DOUBLE WALL CONNECTOR/ INSTALLATION
EN ALCÔVE UTILISANT UN RACCORD DE MUR DOUBLE

MOBILE HOME INSTALLATION USING DOUBLE WALL CONNECTOR/ INSTALLATION EN MAISON MOBILE UTILISANT UN RACCORD DE MUR DOUBLE

·

S’ÉTENDRE DE PAR LE DEVANT, LES COTÉS ET L’ARRIÈRE TEL QU’INDIQUÉ. CET APPRAREIL DE CHAUFFAGE AU BOIS DOIT FAIRE L’OBJETD’ENTRETIENS ET D’INSPECTIONS PÉRIODIQUES POUR UN FONCTIONNEMENT ADÉQUAT. CONSULTEZ LE MANUEL D’UTILISATION POUR PLUS D’INFORMATION.

A. 16 in. / 406 mm

B. 10 in. / 254 mm

C.

N/A

SUMMIT

D. 26 in. / 690 mm

E. 15 in. / 381 mm

F.

N/A

ALDERLEA T6

18 in. / 457 mm 10 in. / 254 mm 8 in. / 203 mm
28 in. / 693 mm 15 in. / 381 mm 18.9 in. / 479 mm

COTE SIDE

DOS BACK I

H

H

HEATER POELE

COTE SIDE

IN CANADA G. AU CANADA H.
I.

IN U.S.A.

G.

H.

18 INCHES / 455 MM 8 INCHES / 200 MM 8 INCHES / 200 MM
16 INCHES / 405 MM 5 INCHES / 127 MM

DATE OF MANUFACTURE

D. 27.6 in. / 688 mm

29.6 in. /739 mm

E. 15.6 in. / 397 mm

15.6 in. / 397 mm

G

I. 0 INCHES / 0 MM

F.

N/A

19.1 in. / 486 mm

FRONT

DEVANT

émissions de particules de 2020.

261018

MADE IN CANADA/ FABRIQUÉ AU CANADA

MANUFACTURED BY/ FABRIQUÉ PAR: PACIFIC ENERGY FIREPLACE PRODUCTS LTD.
2975 ALLENBY RD., DUNCAN, BC V9L 6V8

100001329

3

SAFETY NOTICE: If this stove is not properly installed, a house fire may result. For your safety, follow the installation instructions. Contact local building or fire officials about restrictions and installation inspection requirements in you area.

Please read this entire manual before you install and use

your new room heater. Failure to follow instructions may

result in property damage, bodily injury, or even death.

Efficiency and BTU Output

EPA Certified Emissions LHV Tested Efficiency 1 HHV Tested Efficiency 2 EPA BTU Output 3

Maximum Wood Length Ideal Wood Length Fuel

1 Weighted Average Lower Heating Value (LHV) efficiency as tested using CSA B415 Performance testing of solid-fuelburning heating appliances. LHV assumes the moisture is already in a vapour state so there is no loss of energy
2 Weighted Average Higher Heating Value (HHV) efficiency as tested using CSA B415 Performance testing of solid-fuelburning heating appliances. HHV includes the energy required to vaporize the water in the fuel
3 The range of BTU outputs is based on efficiency using CSA B415 Performance testing of solid-fuel-burning heating appliances and burn rates from the low and high EPA tests using Douglas Fir dimensional lumber.

1.8 grams per hour 80% 74% 16,102 to 41,275 btu/hr

20 inches 16-18 inches Seasoned Cord wood

100000302

Safety
CAUTION: Never use gasoline, gasoline type lantern fuel, kerosene, charcoal lighter fluid or similar liquids to start or “freshen up” a fire in this heater. Keep all such liquids well away from the heater while it is in use.
Instruct all members of your family on the safe operation of the heater. Ensure they have enough knowledge of the entire system if they are expected to operate it. Stress the section on chimney fires and the importance of following the steps outlined “In Case of Chimney Fire”.
Chimney Smoke and Creosote Formation
When wood is burned slowly, it produces tar and other organic vapours, which combine with expelled moisture to form creosote. The creosote vapours condense in the relatively cool chimney flue of a slow burning fire. As a result, creosote residue accumulates on the flue lining. When ignited, this creosote makes an extremely hot fire. The chimney connector and chimney should be inspected periodically (at least once every two months) during the heating season to determine if a creosote buildup has occurred. If creosote has accumulated (3 mm. or more), it should be removed to reduce the risk of a chimney fire.
1. Highest smoke densities and emissions occur when a large amount of wood is added to a bed of hot coals and the air inlet is closed. The heated wood generates smoke, but without ample air, the smoke cannot burn. Smoke-free, clean burning requires small fuel loads, two or three logs at a time or 1/4 to 1/2 of fuel load and leaving the air inlet relatively wide open, especially during the first 10 to 30 minutes after each loading, when most of the smoke generating reactions are occurring. After 30 minutes or so, the air inlet can be turned down substantially without excessive smoke generation. Wood coals create very little creosote-producing smoke.
2. The cooler the surface over which the wood smoke is passing, the more creosote will be condensed. Wet or green wood contributes significantly to creosote formation as the excess moisture that is boiled off cools the fire, making it difficult for the tars and gases to ignite, thus creating dense smoke and poor combustion. This moisture-laden smoke cools the chimney, compounding the problem by offering the smoke the ideal place to condense.
In summary, a certain amount of creosote is inevitable. Regular inspection and cleaning is the solution. The use of dry, seasoned wood and ample combustion air will help to minimize annoying smoke emissions and creosote buildup.
Chimney Fires
The dangerous side effect of excessive creosote buildup is a chimney fire. This causes much higher than normal temperatures in the chimney and on its exterior surfaces. Temperatures inside the chimney can exceed 2000°F (1100°C). Ignition of nearby or touching combustible material is more likely during a chimney fire. Proper clearances are critical to prevent damage during such a fire.
Chimney fires are easy to detect; they usually involve one or more of the following:
· Flames and sparks shooting out of the top of the chimney · A roaring sound · Vibration of the chimney

100000302

4

SUMMIT-LE_310119-28

To Avoid a Chimney Fire 1. Burn wood cleanly. Do not burn wet wood or turn down the unit too quickly after loading.
2. Do not let creosote build up to a point where a chimney fire is possible.
3. Do not have fires in the heater that may ignite chimney fires. These are excessively hot fires, such as when burning household trash, cardboard, Christmas tree limbs, or even ordinary fuel wood; (eg. with a full load on a hot bed of coals and with the air inlet wide open for more time than is needed to completely char a fresh fuel load.)
4. The Chimney and connector pipe should be inspected /cleaned periodicaly.
In Case of a Chimney Fire
1. Prepare to evacuate to ensure everyone’s safety. Have a well understood plan of action for evacuation. Have a place outside where everyone is to meet.
2. Close air inlet on stove.
3. Call local fire department. Have a fire extinguisher handy. Contact your local municipal or provincial fire authority for further information on how to handle a chimney fire. It is most important that you have a clearly understood plan on how to handle a chimney fire.
4. After the chimney fire is out, the chimney must be cleaned and checked for stress and cracks before starting another fire. Also check combustibles around the chimney and the roof.
· The services of a competent or certified installer, (certified by the Wood Energy Technical Training program (WETT) – in Canada, Hearth Education Foundation (HEARTH) – in U.S.A.,) are strongly recommended.
Curing of the Paint Finish To acheive the best finish, the paint on your stove must be baked on. When burning your stove for the first 2-3 times it is very important that the room be well ventilated. Open all windows and doors. Smoke and fumes caused by the curing process may cause discomfort to some individuals.
WARNING: Never use chemicals or any other volatile liquid to start a fire. Do not burn garbage, or flammable fluids such as gasoline, naptha, or engine oil.

SUMMIT-LE_310119-28

5

100000302

Operation
CAUTION: Hot while in operation. Keep children, clothing and furniture away. Contact may cause skin burns.

WARNING: Always keep loading door closed when burning. This heater is not designed for open door burning.

WARNING: No alteration or modification of the combustion air control assembly is permitted. Any tampering will void warranty and could be very hazardous.

WARNING: Do not use grates or andirons to elevate the fuel. Burn directly on the fire bricks. Replace broken or missing bricks. Failure to do so may create a hazardous condition.

Wood Selection

This heater is designed to burn natural wood only. Higher efficiency and lower emissions generally result when burning air-dried seasoned hardwoods, as compared to softwoods or to green or freshly cut hardwoods.

Wood should be properly air dried (seasoned) for six months or more. Wet or undried wood will cause the fire to smoulder and produce large amounts of smoke and creosote. Wet wood also produces very little heat and tends to go out often. Wood should be stored under cover away from open flame or heat sources.

DO NOT BURN : · Salt water wood · Wet or green wood · Garbage · Lawn clippings/yard waste · Railroad ties · Materials containing rubber, including tires · Construction or demolition debris · Waste petroleum products, paints, paint thin-
ners, or asphalt products

· Treated wood · Coal/charcoal · Solvents · Unseasoned wood · Manure or animal remains · Materials containing plastic · Materials containing asbestos · Paper products, cardboard, plywood, or
particleboard.

  • These materials contain chlorides which will rapidly destroy metal surfaces and void warranty.

Burning these materials may result in the release of toxic fumes or render the heater ineffective and cause smoke.

Do not burn anything but wood. Other fuels, eg. charcoal, can produce large amounts of carbon monoxide, a tasteless, odourless gas that can kill. Under no circumstances should you attempt to barbecue in this heater.

The prohibition against burning these materials does not prohibit the use of fire starters made from paper, cardboard, saw dust, wax and similar substances for the purpose of starting a fire in an affected wood heater.

How to Test Your Wood

Add a large piece of wood to the stove when it has a good large bed of coals. It is dry if it is burning on more than one side within one minute. It is damp if it turns black and lights within three minutes. If it sizzles, hisses and blackens without igniting in five minutes it is soaked and should not be burnt

100000302

6

SUMMIT-LE_310119-28

Lighting a fire
WARNING: Never use chemicals or any other volatile liquid to start a fire.
1. Adjust air control to “High” position(all the way to the left) and open door.
2. Place crumpled newspaper in the centre of the heater and criss-cross with several pieces of dry kindling. Add a few small pieces of dry wood on top.
3. Ignite the paper and leave the door ajar approimately 1/2″(13mm) – 1″(25mm) until the wood kindling is fully engulfed in flame.
4. After the kindling is fully engulfed add a few small logs. Close door.
5. Begin normal operation after a good coal base exists and wood has charred.
Normal Operation
WARNING: This wood heater has a manufacturer-set minimum low burn rate that must not be altered. It is against federal regulations to alter this setting or otherwise operate this wood heater in a manner inconsistent with the operating instructions in this manual.
1. Set air control to a desired setting. If smoke pours down across the glass (waterfall effect) this indicates you have shut the control down too soon or you are using too low a setting. The wide range control panel makes finding the desired setting for your application easy. As every home’s heating needs vary (ie. insulation, windows, climate, etc.) the proper setting can only be found by trial and error and should be noted for future burns.
2. To refuel, adjust air control to high, and give the fire time to brighten. Open the door slowly, this will prevent backpuffing.
3. Use wood of different shape, diameter and length (up to 18″(457mm)). Load your wood endwise and try to place the logs so that the air can flow between them. Always use dry wood.
4. Do not load fuel to a height or in such a manner that would be hazardous when opening the door.
5. For extended or overnight burns, unsplit logs are preferred. Remember to char the wood completely on maximum setting before adjusting air control for overnight burn.
· Burn wood only, dry and well seasoned. The denser or heavier the wood when dry, the greater its heat value. This is why hardwoods are generally preferred. Green or wet wood will cause a rapid buildup of creosote. If you feel it is necessary to burn wet or unseasoned wood, do so only with the air inlet set open enough to maintain a good strong fire and fairly high chimney temperatures. Do not attempt to burn overnight using green wood or wet wood. Wet wood can cause up to 25% drop in heater output, as well as contributing significantly to creosote buildup.
DO NOT OVERFIRE THIS HEATER: Attempts to achieve heat output rates that exceed heater design specifications can result in permanent damage to the heater and chimney. A glowing red, top or vent pipe are indications of overfiring. Failure to recitify an over firing condition can be hazardous and may void the manufacturer’s warranty.

SUMMIT-LE_310119-28

7

100000302

Restarting After Extended or Overnight Burns
1. Open door and rake hot embers towards the front of the heater. Add a couple of dry, split logs on top of embers, close door.
2. Adjust air control to high and in just a few minutes, logs should begin burning.
3. After wood has charred, reset air control to desired setting.
4. To achieve maximum firing rate, set control to high “H”. Do not use this setting other than for starting or preheating fresh fuel loads.
Proper Draft
1. Draft is the force which moves air from the appliance up through the chimney. The amount of draft in your chimney depends on the length of the chimney, local geography, nearby obstructions and other factors.
2. Too much draft may cause excessive temperatures in the appliance. An uncontrollable burn or a glowing red stove part or chimney indicates excessive draft.
3. Inadequate draft may cause backpuffing into the room and plugging of the chimney. Smoke leaking into the room through appliance and chimney connector joints indicates inadequate draft.
Remember the correct air inlet setting is affected by variables such as type of wood, outside temperature, chimney size and weather conditions.
Ash Removal
Caution: Ashes are to be removed only when the heater is cold. Whenever ashes get 3″(76mm) to 4″(102mm) deep in your firebox, and when fire has burned down and cooled, remove excess ashes. Leave an ash bed approximately 1″ (25 mm) deep on the firebox bottom to help maintain a hot charcoal bed.
Ash Cleanout system (optional):
The ash dump handle is located under the ash lip on the left hand side. To operate ash dump, pull handle out 1/2″(13mm) and turn clockwise. This will unlock the ash dump and allow it to open. Hold handle open while pulling ashes into the opening. Avoid large embers as these still contain heat value. Release handle and push in to lock. Ensure ash dump door is properly engaged. Fill the cavity with the remaining ash level with the firebox floor. Lift and pull out ashpan and discard ashes into metal container. Replace ashpan and ensure it is seated properly.
Do not burn with ash dump door open. Doing so will create a hazardous condition. Always leave about 1″(25mm) of ash when cleaning.
Disposal of Ashes
Ashes should be placed in a metal container with a tight fitting lid. The closed container of ashes should be placed on a non-combustible floor or on the ground, well away from all combustible materials, pending final disposal. If the ashes are disposed of by burial in soil or otherwise locally dispersed, they should be retained in closed container until all cinders have thoroughly cooled. Other waste should not be placed in this container.

100000302

8

SUMMIT-LE_310119-28

Maintenance
WARNING: Never use chemicals or any other volatile liquid to start a fire. Do not burn garbage, or flammable fluids such as gasoline, naptha, or engine oil.
WARNING: ONLY USE MATERIALS SUPPLIED BY MANUFACTURER WHEN DOING MAINTENANCE OR REPLACEMENTS.
1. If glass becomes darkened through slow burning or poor wood, it can readily be cleaned with fireplace glass cleaner when stove is cold. Never scrape with an object that might scratch the glass. The type and amount of deposit on the glass is a good indication of the flue pipe and chimney buildup. A light brown dusty deposit that is easily wiped off usually indicates good combustion and dry, well-seasoned wood and therefore relatively clean pipes and chimney. On the other hand, a black greasy deposit that is difficult to remove is a result of wet and green wood and too slow a burning rate. This heavy deposit is building up at least as quickly in the chimney.
2. DOOR GASKETS – The gasket used by Pacific Energy (7/8″(22mm) medium density fiberglass rope) requires only light pressure to seal. This will prolong seal life. It is important that the door seal be maintained in good condition. Periodically inspect seals and replace if necessary. Follow the instructions included in the DR46.GLKIT kit, obtainable from your nearest Pacific Energy dealer.
3. DOOR GLASS – Do not slam loading door or otherwise impact glass. When closing door, make sure that no logs protrude to impact the glass. If the glass gets cracked or broken, it must be replaced before using the stove. Replacement glass can be obtained from your dealer. Use 17-1/2″(445mm) x 9-1/2″(241mm) x 5 mm. Ceramic glass only. Do not substitute with any other type.
· To remove broken glass, undo the four retaining screws and remove clamps and frame, noting position for re-assembly. Remove all particles of glass . Be careful as they are very sharp. Install new glass complete with gasket. Replace frame, clamps and screws.
CAUTION: – do not overtighten, tighten screws very carefully – do not clean glass when hot – do not use abrasive cleaners on glass
4. The area where boost combustion air enters the firebox must be kept clear of excessive ash buildup which will block air flow. This area is at the front of the firebox.
5. Do not store wood within heater installation clearances, or within the space required for fuel loading and ash removal. Keep the area around the heater clean and free of loose combustibles, furniture, newspapers, etc.
6. If the plated door requires cleaning, use mild soap and water only. Use of abrasive cleaners will void warranty.
7. Establish a routine for the fuel, woodburning and firing technique. Check daily for creosote buildup until experience shows how often you need to clean to be safe.
8. Be aware that the hotter the fire, the less creosote is deposited. Weekly cleaning may be necessary in mild weather, even though monthly cleaning is usually enough in the coldest months when burning rates are higher. When wood is burned slowly, it produces tar and other organic vapours, which combine with expelled moisture to form creosote.

SUMMIT-LE_310119-28

9

100000302

Maintenance Checks
Check the following parts for damage such as cracks, excessive corrosion, burned out sections and excessive warping: (See website for descriptions and more detail)
Weekly:
· Firebrick – Visual, for cracking. · Door Gasket – sagging, placement, damage.
Monthly
· Brick rail tabs and brick rails. · Air riser tube in the back of the firebox. · Back side of airwash chamber. · Baffle locking pin. · Boost tube cover.
When Cleaning the Chimney System:
· Top baffle board/blanket. · Baffle. · Top heat shield and mounting bolt. · Baffle Gasket. · Brick Rails. · Manifold.
Blower:
· The blower should be cleaned out a minimum every six months by using a vacumn on the grill openings in the back and bottom of the blower casing to remove any dust and debris.
Baffle:
· Some warping of the baffle is normal(up to 1/4″ or .65cm). Replace if the baffle has permanent warping greater than this or has cracking or breakage.
· Please contact your Dealer if you experience any of the damage listed above. Continuing to operate your stove with broken parts may accelerate damage to other parts and may void your warranty
Baffle Removal
Chimney connector pipe should be disconnected from stove to clean and inspect. Only if this is not possible should you remove baffle assembly.
DO NOT OPERATE WITH BAFFLE ASSEMBLY OR INSULATION REMOVED.
Removal
Remove retaining pin at the back top of the firebox, just under the baffle. Lift baffle up and pull forward to disconnect from the supply tube. Tilt baffle sideways to drop down and remove from firebox. Inspect gasket between baffle and supply tube. If necessary, replace with gasket #139.5 available from your Pacific Energy dealer. Re-install baffle assembly in reverse order. The two side pieces of insulation must be tight against the siderails.

100000302

10

SUMMIT-LE_310119-28

Dimensions

27″ 686mm

28″ 711mm
23 3/4″ 603mm

8 1/2″ 216mm

31 3/4″ 806mm

30″ 762mm

SUMMIT – Pedestal Option

27″ 686mm

23 3/4″ 603mm

8 1/2″ 216mm

27 5/8″ 702mm

29 1/4″ 743mm

SUMMIT – Leg Option

25 1/2″ 648mm

25 5/8″ 699mm

8 1/2″” 216mm

28 3/8″ 721mm

SUMMIT-LE_310119-28

SUMMIT CLASSIC
Figure 2: Summit LE dimensions.
11

100000302

Crate Removal
1. Carefully remove the crate top and supports. 2. Remove plastic cover. 3. Using a 7/16″ wrench, remove lag bolts that secure stove body to bottom pallet
Assembly – Legs (Leg Model)
1. Loosen the four bolts holding the Leg Adapter to the firebox bottom.
2. Insert the legs between the Leg Adapter flange and the washers.
3. Using the guides cast into the tops of the leg, align the guides into the notches in the Ash Box mounting flanges.
4. Tighten the bolts down.

Assembly – Optional Ash Cleanout

Pedestal Model

1. Remove the Ash Drawer Front Cover Plate by removing the center screw(1) and lifting up to dis-engage the bottom tab.

2. Remove the knock-out on the left side at the top of the opening.
3. Install the Ash Dump mechanism, following the instructions on the next page.

Knock-out

Remove Screw

4. Install the new Ash Pan into the Pedestal.

Leg Model 1. Remove the two screws holding the Leg
Ash Box front cover (located on either side). Remove the cover 2. Remove the knock-out on the left side at the top of the opening. 3. 4. Install the Ash Dump mechanism, following the instructions. 5. Install the new Ash Pan into the Leg Ash Box.

Locating Tab
Figure 3: Ped Cover removal.
Knock-out Remove Screws
Figure 4: Leg Ash Cover removal.

100000302

12

SUMMIT-LE_310119-28

Ash Dump Installation
1. Remove the Ash Cleanout hole cover plate and gasket, located under the stove. Discard the cover plate.

2. Place the provided gasket around the upper tube portion of the new Ash Dump mechanism, as per the picture.

1
Figure 5: Cover Plate removal
2

3. Insert The Ash Dump mechanism with gasket from underneath the firebox bottom up into the open hole and over the two bolts hanging down. – The release handle should be facing forward and on the left side, inserted in the slot located in the Pedestal or Leg adapter.
4. Re-attach the nuts onto the cairrage bolts. And tighten to gently compress the gasket.

Figure 6: Ash Cleanout Gasket. Gasket
4 Release Handle Figure 7: Under side of bolted ash Cleanout.

SUMMIT-LE_310119-28

13

100000302

Floor Protector
The stove may be installed on a combustible floor provided noncombustible ember protection is used. This protection must extend as follows:
In USA: 16″ (406 mm) to the front and 8″ (203 mm) to the sides of the fuel loading door opening. See Figure #4, below. This protection is also required under the chimney connector and 2″ (51 mm) beyond each side.
U.S.A. Only
Minimum Width – 35″(890mm) Minimum Overall Depth – 40 5/8″(1.03m)
Non-combustible floor protector

8″ [203mm] 8″ [203mm]

8″ [203mm] 8″ [203mm]

16″ [406mm] Figure 8: Summit LE Floor protector – USA only.

Canada Only
Minimum Width – 42′(1.07m) Minimum Overall Depth – 51″(1.3m)
8″ [203mm]

In Canada: 18″ (457 mm) on the firing side and 8″ (203 mm) to the other sides.

100000302

18″ [457mm] Non-combustible floor protector
Figure 9: Summit LE Floor protector – Canada only.

14

SUMMIT-LE_310119-28

Clearances:

Residential Installation

Single Wall Connector – Residential

17 1/2″ 445mm

9″ 229mm

14″ 356mm

27 1/2″ 698mm

20 3/4″ 527mm
6″ 152mm

6″ 152mm

16″ 406mm

7 1/2″ 191mm
13″ 330mm
26 1/2″ 673mm

Double Wall Connector – Residential

18 1/2″ 470mm

10″ 254mm
16″ 406mm
29 1/2″ 749mm

Alcove: Min. Height 7 1/2′(2.29m) Max. Depth 3′(915mm)

19 3/4″ 502mm
5″ 127mm

5″ 127mm

Figure 10: Summit LE Minimum clearances.

Clearances may be reduced with various heat shielding/insulating materials. Consult CSA B365 or NFPA 211 and local fire codes and authorities for approval. For close clearances, use a listed double-wall connector.
NOTE: local/national codes or regulations may override some guidelines in this manual
We recommend that our products be installed and/or serviced by professionals who are certified by a “Qualified agency”;
NFI (National Fireplace Institute®) in the United States, CSIA (Chimney Safety Institute of America) in the United States and Canada, WETT (Wood Energy Technology Transfer) in Canada or APC (Association des Professionnels du Chauffage) in Quebec

SUMMIT-LE_310119-28

15

100000302

Warning: Under no circumstances is this heater to be installed in a makeshift or “temporary” manner. It may be fired only after the following conditions have been met.
DO NOT ATTEMPT TO CONNECT THIS HEATER TO ANY AIR DISTRIBUTION DUCT.
Outside combustion air or fresh air into the room may be required in your area, consult local building codes (see Combustion Air section).

Chimney and Connector
· The chimney system must be a ULC-S629 or UL-130HT listed Stainless chimney or a Masonry chimney suitable for use with solid fuel, that is lined, in good condition and meets fire and building codes.
· The chimney flue size should be the same as the stove outlet (6 inches) for optimal performance. Reducing or increasing the flue size may adversely affect stove performance.
· Chimney flue exit is to be 3 feet (1 m.) above roof and two feet (0.6 m.) above highest projection within 10 feet (3 m.).
· The installation must meet all local codes.
· Do not connect this unit to a chimney flue serving another appliance. Minimum system height is 15 feet (4.6 m.) (measured from base of appliance).
BOTH CHIMNEY SYSTEM AND CONNECTOR MUST BE LISTED TO: IN CANADA – ULC S-641 LISTED double wall connector and ULC-S629 LISTED CHIMNEY, IN USA – UL-103 HT LISTED CONNECTOR AND CHIMNEY
When using a Double-Wall Connector
· Use a listed double-wall connector.
· If a listed chimney and double-wall connector are to be connected to the stove, install all components as per the chimney/connector manufacturer’s installation requirements.
When using a Single-Wall (smoke pipe) Connector The single wall pipe section must be:
· If you are using smoke pipe/chimney connector in conjunction with the listed chimney system, consult local/national fire or building codes for connector installation. Follow the chimney manufacturer’s complete instructions for the installation of the chimney system.
· As short and straight as possible, use six inch diameter, 24 gauge black pipe that is clean and in new condition.
· Installed with the crimped or male ends pointing down. (This will carry any liquid creosote or condensation back into the stove) and secured at every joint and collar with 3 sheet metal screws.
· The chimney connector shall not pass through an attic, roof space, closet or similar concealed space, floor, or ceiling. Where passage through a wall, or partition of combustible material is desired, the installation shall conform to CAN/CSA-B365, Installation Code for Solid-Fuel-Burning Appliances and Equipment

100000302

16

SUMMIT-LE_310119-28

Installation Procedure
1. Select the position for your wood stove based on the clearances diagram. Position the stove and floor protection.
2. Mark the position for the hole in the ceiling and roof by using a string and plumb-bob hanging over the exact center of the stoves flue pipe.
3. Check that the intended location will not interfere with floor joists, ceiling joists or rafters before proceeding further. Adjust if necessary and reconfirm the clearance’s from the stove to combustibles.
4. Carefully follow the directions of the listed chimney for installation of the chimney system from the ceiling through to the rain cap. This may include framing in holes etc.
5. Start installing smoke pipe (chimney connector), slip crimped edge of the pipe inside the stove collar. Use holes provided in collar to secure pipe with two screws.
6. Install the remaining lengths of pipe one on top of the other up to the finished height of the chimney and using the manufacturers approved adapter, secure to each other. A slip section can make this easier.
Combustion Air
Intake or combustion air can be supplied to the stove in one of two ways. Consult your local building code or CAN/CSA-B365, Installation Code for Solid- Fuel-Burning Appliances and Equipment before proceeding.
Outside air supply – (Necessary for mobile home installation, optional for residential installation.)
To draw outside air through the floor – This hole must get its air from a ventilated crawl space or be extended with duct to the outdoors (see Figure

3, Page 7). The use of outside combustion air for residential installation

requires the unit to be secured to the structure to prevent dislodging of the air duct.
· Leg Model: Cut or drill a hole in the floor, (large enough to fit 4″ metal flex venting) behind the ash box enclosure. Once the stove is in place, attach the 4″ Intake Starter to the Ash Box Enclosure. Connect to the floor with the 4″(100mm) i.d. metal flex pipe.
· Pedestal Model: Cut or drill a 4″ (100mm) diameter hole in the floor anywhere inside the perimeter of the pedestal base. Cover the hole with a 4″ x 4″ (100 mm x 100 mm) rodent screen and staple/nail in place. Leave the cover over the hole on the back of the Pedestal. Place the stove over the hole.
To draw outside air from behind the stove, Use a 4″(100mm) Air intake. Cut or drill the recomeneded size hole through a wall behind the unit.
· Install the 4″ Intake Starter over the hole in the rear of the Ash Box enclosure. Attach metal flex between the starter and the Air Intake.
· Pedestal Model: Remove the cover plate from the rear of the pedestal and install the cover plate over the hole located under the Pedestal. Install the 4″ Intake Starter over the hole in the rear. Attach metal flex between the starter and the wall inlet.
Room air supply – The stove will draw its air from the room through the opening in the Ash Box Enclosure and into the firebox intake.
Note:The living space around the heater must be well ventilated with good air circulation. Anything that may cause a negative pressure can cause gases or fumes to be pulled into the living area. During extremely cold weather, and especially when burning at very slow rates, the upper parts of the exposed chimney may ice up, partially blocking the flue gases. If blockage occurs, flue gases may enter the living space.

SUMMIT-LE_310119-28

17

100000302

Follow chimney manufacture specifcations for distance between vent termination heigth and chimney at roof line. Also consult local building regulations.

Spark arrester rain cap

Listed Insulated Chimney
Storm collar

Roof flashing

The chimney may incorporate an offset. To do this safely, all sections of listed connector, offset elbows and chimney section must be screwed together by at least three sheet metal screws per joint. The chimney must be suitably supported by the chimney manufacturer’s listed offset support. All vent manufacturer or national fire code clearances to combustible must be observed.

54″ [1.37m] Minimum
Chimney connector

Combustibles in front of the unit

48″ [1.2 m]

as per Local and Federal
codes

Chimney Support
Wall Thimble

12″ [300mm] Minimum
first section

  • of pipe

Alternate up and out installation

  • Unit may be harder to start. Please provide as much vertical length for the first section of pipe as possible

100000302

Non-combustible Ember Protector

  • 4″ (102 mm) diameter air inlet with rodent screen.
  • If the crawl space is well ventilated it is not necessary to extend air inlet to outside.
    Figure 11: Summit LE residential venting.
    18

4″ diameter hooded air inlet or 90 elbow turned down with rodent screen.
SUMMIT-LE_310119-28

Ensure that the Masonry chimney meets all National Fire Protection Association and local building codes. Have the chimney cleaned and inspected by a professional to ensure there are no cracks, weak mortar or other signs of deterioration. See vent manufactuer’s installation instructions for further information

Fireclay Flue Liner Concrete Cap
Chimney

6″ S.S. liner

54″ (1.37m) Minimum

Combustibles in front of the unit

48″ (1219 mm)
Non-combustible Ember Protector

Chimney Connector

Approved Through Wall Installation

  • 4″(102mm) diameter air inlet with rodent screen
  • If the crawl space is well ventilated it is not necessary to extend air inlet to outside

Figure 12: Summit LE Venting to a masonry chimney.

SUMMIT-LE_310119-28

19

Hooded vent or 90° elbow turned down.
100000302

Through Wall Installations (as per NFPA 211-2013)
ATTENTION: VAPOUR BARRIER MUST BE MAINTAINED WHEREVER CHIMNEY OR OTHER COMPONENTS PENETRATE TO THE EXTERIOR OF THE STRUCTURE. SEE LOCAL BUILDING CODES FOR PROPER AND APPROVED METHODS OF MAINTAINING VAPOUR BARRIER.

SYSTEM A

Minimum chimney clearance to brick and combustibles 2″ (51 mm).
Minimum clearance 12″ (305 mm) of brick

Chimney flue

Minimum 12″ (305 mm) to combustibles
Figure 13: System A.

Chimney connector
Fireclay liner
Masonry chimney constructed to NFPA 211

Minimum Clearance 12 in. (305mm) to combustibles

System A. Minimum 3.5 in. (90 mm) thick brick masonry wall framed into combustible wall with a minimum of 12 in. (305 mm) brick separation from clay liner to combustibles. Fireclay liner (ASTM C 315, Standard Specifications for Clay Fire Linings, or equivalent), minimum 5/8 in. (16 mm) wall thickness, shall run from outer surface of brick wall to, but not beyond, the inner surface of chimney flue liner and shall be firmly cemented in place.

SYSTEM B

Minimum chimney clearance from masonry to sheet steel supports and combustibles 2″ (51 mm)

Nonsoluble Factory built refractory chimney length cement

Minimum clearance 9″ (229 mm)
Chimney connector

Chimney length

flush with inside

of flue

Air space: 9″ (229 mm) min.

Chimney flue

Masonry chimney constructed to NFPA 211

Use chimney manufacturers’ parts to attach connector securely
Solid-insulated, listed factory built chimney length

Sheet steel supports

Figure 14: System B.

Minimum Clearance 9 in. (229mm) to combustibles

System B. Solid-Insulated, listed factory-built chimney length of the same inside diameter as the chimney connector and having 1 in. (25.4 mm) or more of insulation with a minimum 9 in. (229 mm) air space between the outer wall of the chimney length and combustibles.

The inner end of the chimney length shall be flush with the inside of the masonry chimney flue and shall be sealed to the flue and to the brick masonry penetration with non-water-soluble refractory cement. Supports shall be securely fastened to wall surfaces on all sides.

Fasteners between supports and the chimney length shall not penetrate the chimney liner.

100000302

20

SUMMIT-LE_310119-28

SYSTEM C
Minimum chimney clearance from masonry to sheet steel supports and combustibles 2″ (51 mm)

Two ventilated air channels, each 1″ (25.4 mm)
Chimney connector

Chimney flue

Minimum 6″ (152 mm) glass fiber insulation

Two ventilated air channels,

each 1″ (25.4 mm);

Masonry chimney

Sheet steel supports

construction of sheet steel constructed to NFPA 211

Figure 15: System C.

Minimum Clearance: 6 in. (152mm) to combustibles
System C. Sheet steel chimney connector, minimum 24 gauge [0.024 in. (0.61 mm)] in thickness, with a ventilated thimble, minimum 24 gauge [0.024 in. (0.61 mm)] in thickness, having two 1 in. (25.4 mm) air channels, separated from combustibles by a minimum of 6 in. (152 mm) of glass fiber insulation. Opening shall be covered, and thimble supported with a sheet steel support, minimum 24 gauge [0.024 in. (0.61 mm))] in thickness.
Supports shall be securely fastened to wall surfaces on all sides and shall be sized to fit and hold chimney section. Fasteners used to secure chimney section shall not penetrate chimney flue liner.

SYSTEM D

Minimum chimney clearance to sheet steel supports and combustibles 2″ (51 mm)

Sheet steel supports

Minimum clearance 2″ (51 mm)

Chimney section

1″ (25.4 mm) air space to chimney length

Chimney flue

Chimney connector

Chimney connector

Air space:

Chimney length

2″ (51 mm) min.

Sheet steel supports

Masonry chimney

constructed to NFPA 211

Figure 16: System D.

Minimum Clearance: 2 in. (51mm) to combustibles

System D. Solid-Insulated, listed factory-built chimney length with an inside diameter 2 in. (51 mm) larger than the chimney connector and having 1 in. (25.4mm) or more of insulation, serving as a pass-through for a single-wall sheet steel chimney connector of minimum 24 gauge [0.024 in. (0.61 mm)] thickness, with a minimum 2 in. (51 mm) air space between the outer wall of chimney section and combustibles.

Minimum length of chimney section shall be 12 in. (305 mm). Chimney section concentric with and spaced 1 in. (25.4 mm) away from connector by means of sheet steel support plates on both ends of chimney section. Opening shall be covered, and chimney section supported on both sides with sheet steel supports of minimum 24 gauge [0.024 in. (0.61 mm)] thickness.

Supports shall be securely fastened to wall surfaces on all sides and shall be sized to fit and hold chimney section. Fasteners used to secure chimney section shall not penetrate chimney flue liner.

SUMMIT-LE_310119-28

21

100000302

Mobile Home Installation
Warning: Under no circumstances is this heater to be installed in a makeshift or “temporary” manner. It may be fired only after the following conditions have been met.
· DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE.
· DO NOT INSTALL IN A SLEEPING ROOM.
· CAUTION: THE STRUCTURAL INTEGRITY OF THE MOBILE HOME FLOOR, WALL AND CEILING/ ROOF MUST BE MAINTAINED.
· Attach the stove to the floor using two 1/4″ x 2″ or longer lag screws through holes in the legs or the Pedestal base.
· Outside air supply must be used for Mobile Home installations – see .pg.16
· The services of a competent or certified installer, (certified by the Wood Energy Technical Training program (WETT) – in Canada, Hearth Education Foundation (HEARTH) – in U.S.A.,) are strongly recommended.
Clearances
This heater must be installed with listed double-wall connector and compatible ULC-S629 or UL-103HT listed chimney system, see page 17.
Clearances to combustible surfaces and materials are shown. See picture below.
Consult local fire codes and authorities for approval.
NOTE: Install all components to the connector or chimney manufacturer’s installation requirements. Consult your chimney supplier/manufacturer for installation advice.

Double Wall Connector – Mobile Home
10″ 254mm

18 1/2″ 470mm

18″ 457mm
31 1/2″ 800mm

22 3/4″ 578mm
8″ 203mm

Figure 17: Summit LE Minimum clearances – Mobile Home.

8″ 203mm

100000302

22

SUMMIT-LE_310119-28

Optional Blower
The optional blower kit (kit #WODC.BLOWB) is equipped with a three prong power cord and may be installed at any time. Follow installation instructions supplied with the kit. Route power supply cord away from heater.
Electrical rating: 115 volts A.C.-1.02 amps. Fan output rating: 140 CFM
Blower Operation
Proper blower speed matched with air control setting will ensure peak performance from your stove. Operate as follows:
· Air control set to “L” (low), operate blower speed control on “Low”. · Air control set between “L” and “H” (low and high), operate blower speed control at desired setting.
Automatic: To operate the blower automatically, set the rocker switch on the side of the fan housing to “Auto” and set the speed control to desired setting. This will allow the fan to turn on as the stove heats up to operating temperature. It will also shut the blower off after the fire has gone out and the unit cooled to below a useful heat output range.
Manual: To manually operate the blower, set the rocker switch to “Man” and set the speed control to desired setting. This will bypass the sensing device and allow full control of the blower. Switching from “Auto” to “Man” or selecting speed may be done anytime.
Firebricks

E

D

C

E

D

C

A

D

B

Figure 18: With ash cleanout system installed. ITEM

Figure 19: Without ash cleanout system installed.

SIZE

PART NUMBER

A ……………… 1 1/2″ X 4 1/2″ X 1 1/4″ ………………….(39 mm x 115 mm x 32 mm)………………………. 248.001 B ……………… 4″ X 4 1/2″ X 1 1/4″………………………..(102 mm x 115 mm x 32 mm)…………………….. 246.001 C ……………… 7 1/4″ X 4 1/2″ X 1 1/4″ ………………….(184 mm x 115 mm x 32 mm)…………………….. 245.001 D ……………… 9″ X 4 1/2″ X 1 1/4″………………………..(230 mm x 115 mm x 32 mm)…………………….. 5096.99 E ……………… 9″ X 4 1/2″ w/ corner cut X 1 1/4″ ……(230 mm x 115 mm w/ corner cut x 32 mm) … 3245.011

SUMMIT-LE_310119-28

23

100000302

Firebrick Installation

E

E

E DC DE

Figure 20: Corner floor bricks.

Figure 21: Back row of bricks.

1. Begin by placing the 2 “E” bricks into the rear corners of the firebox floor (Figure 20). These trimmed bricks will fit around the two bolts coming up in the back corners. Continue by placing 2 “D” bricks beside the “E” bricks and the short “C” brick in the center up against the baffle tube (Figure 21). Eliminate any gaps between the bricks by shifting the bricks in toward the center of the firebox.

2. On units with an ash dump, place 4 “D” bricks along the front row; 3 bricks on one side of the ash dump and 1 brick on the other side. Use the “A” and “B” bricks to fill in the area around the ash dump (Figure 22).
· If an ash dump is not installed, use the extra “D” brick instead of the “A” and “B” bricks to fill in this space. Eliminate any gaps between the bricks by shifting the bricks in towards the center of the firebox.

E D C DE

B

D

DDD

A

Figure 22: Floor bricks completed.

Brick rail tabs

DD

DD

DD DD

Baffle tube

Figure 23: Rear wall bricks.

Figure 24: Side wall brick placement.

3. Slip 4 “D” bricks up behind the two protruding brick rail tabs along the rear wall (Figure 23). Eliminate any gaps between the bricks by shifting the bricks in toward the baffle tube.

4. Place 2 “D” bricks along one of the side walls by slipping them up under the side brick rail tabs (Figure 24) and pushing to the rear, past the back brick. Place two more “D” bricks in the remaining opening at the front of the firebox and eliminate any gaps between the bricks by shifting the bricks toward the rear wall.

5. Complete the brick installation by repeating step 4 on the opposite side wall.

100000302

24

SUMMIT-LE_310119-28

Problem
Excessive Creosote Build-up
Glass is Dirty

Trouble Shooting

Cause

Cure

  1. Wood is too wet

– Use dry wood

  1. Turning down air control – Do not turn down until:

too soon

a) there is a good bed of coals

b) the wood is charred

  1. Draft too low

– Chimney plugged or restricted, check flue – Improper chimney height and/or diameter – Provide outside air for combustion – Check draft in chimney and system, alter as
needed.

  1. See 1, 2, and 3 above

  2. Door Gasket leakage – Replace gasket – Check door latch

Low Heat Output

  1. Wood may be wet 2) Fire too small 3) Draft too low

– Check wood and use drier wood if required.
– Build a larger fire – Open draft control to increase burn rate. – Chimney plugged or restricted
Inspect and clean

Won’t Burn Overnight

  1. Air control set too high 2) Not enough wood 3) Draft too high

– Set control lower – Unsplit wood is preferred for overnight burns – Excessive chimney hieght and/or diameter,
see page 11

Stove Won’t Burn

  1. Combustion air supply – Check outside air supply for obstructions

is blocked

– Check that room air cover is removed.

– Chimney plugged or restricted Inspect and clean

SUMMIT-LE_310119-28

25

100000302

Replacement Parts – SUMMIT LE
(WHEN ORDERING, INCLUDE PART NUMBER WITH DESCRIPTION)

ITEM

DESCRIPTION

PART NO.

1………… Side Shield, Summit LE, MBK…………………….. 80002218 3………… Cast Ash Lip ……………………………………………. 80000018 4………… Air Control, Primary …………………………………… 80002215 5………… Clamps, Wood, Glass (4 pc.) ……………………..80000369 6………… Glass Frame, Summit (2 pc.) ……………………..80000399 7………… Glass, Summit, DR46 (c/w Tape) ………………… 80000159 8………… Gasket, Summit, DR46, 7/8″ ………………………. 80000158 9………… Door, Casting Only, DR46, Met Black…………… 80000146 ………….. Door, Casting Only, DR46, Nickel…………………80000780 ………….. Door, Casting Only, DR46, Brushed Ni ………… 80002219 10………. Handle, Door …………………………………………….80000660 11 ………. Baffle Kit, Summit LE …………………………………80002220 12………. Brick Rails, Summit LE, (2pc) …………………….80002221 13………. Pin, Baffle, (10pc) ………………………………………80000364 14………. Gasket, Baffle……………………………………………80000365 15………. Flame Shield, Summit B,LE ………………………..80000393

ITEM

DESCRIPTION

PART NO.

16………. Catch, Door ………………………………………………80000655 17………. Gasket, Air Control, Secondary …………………..80002222 18………. Air Control, Secondary)………………………………80000841 19………. Pedestal Assembly, Summit ……………………….. 80001046 20………. Pedestal Front Cover, Summit…………………….. 80001049 21………. Ash Dump Assembly …………………………………. 80001793 22………. Ash Box, Ped, Summit ………………………………. 80000401 23………. Firebrick Set, Summit LE…………………………….80002223 24………. Manifold, Boost, Summit LE………………………..80002224 25………. Adapter, Leg, Summit…………………………………80002230 28………. Leg, Met Black, (1pc) ………………………………… 80000148 ………….. Leg, Nickel, (1pc) ………………………………………80000783 ………….. Leg, Bruched Nickel (1pc) ………………………….. 80000147 29………. Ash Pan, Leg, Summit……………………………….. 80001050

11

15

1

14 13
12 12
6 7 8 9 10

16
3 5

4

21

17
1 18

All parts may be ordered from your nearest Pacific Energy dealer.
Visit www.pacificenergy.net for the location of the dealer nearest you.

24 23
100000302

29 20 22

25 28
19

26

SUMMIT-LE_310119-28

Replacement Parts – SUMMIT CLASSIC LE
(WHEN ORDERING, INCLUDE PART NUMBER WITH DESCRIPTION)

ITEM

DESCRIPTION

PART NO.

4………… Air Control, Primary …………………………………… 80002215 5………… Clamps, Wood, Glass (4 pc.) ……………………..80000369 6………… Glass Frame, Summit (2 pc.) ……………………..80000399 7………… Glass, Summit, DR46 (c/w Tape) ………………… 80000159 8………… Gasket, Summit, DR46, 7/8″ ………………………. 80000158 9………… Door, Casting Only, DR46, Met Black…………… 80000146 ………….. Door, Casting Only, DR46, Nickel…………………80000780 ………….. Door, Casting Only, DR46, Brushed Ni ………… 80002219 10………. Handle, Door …………………………………………….80000660 11 ………. Baffle Kit, Summit LE …………………………………80002220 12………. Brick Rails, Summit LE, (2pc) …………………….80002221 13………. Pin, Baffle, (10pc) ………………………………………80000364 14………. Gasket, Baffle……………………………………………80000365 15………. Flame Shield, Summit B,LE ………………………..80000393 16………. Catch, Door ………………………………………………80000655 17………. Gasket, Air Control, Secondary …………………..80002222 18………. Air Control, Secondary)………………………………80000841 19………. Pedestal Assembly, Summit ……………………….. 80001046 20………. Pedestal Front Cover, Summit…………………….. 80001049 21………. Ash Dump Assembly …………………………………. 80001793

ITEM

DESCRIPTION

PART NO.

22………. Ash Box, Ped, Summit ………………………………. 80000401 23………. Firebrick Set, Summit LE…………………………….80002223 24………. Manifold, Boost, Summit LE………………………..80002224 25………. Adapter, Leg, Summit…………………………………80002230 28………. Leg, Met Black, (1pc) ………………………………… 80000148 ………….. Leg, Nickel, (1pc) ………………………………………80000783 ………….. Leg, Bruched Nickel (1pc) ………………………….. 80000147 29………. Ash Pan, Leg, Summit……………………………….. 80001050 30………. Side Shield, Summit Classic, Ivory ………………80000391 ………….. Side Shield, Summit Classic, Red………………..80000392 ………….. Side Shield, Summit Classic, Black Pearl …….. 80001042 31………. Top, Summit Classic, Ivory ………………………….80000382 ………….. Top, Summit Classic, Red …………………………..80000383 ………….. Top, Summit Classic, Black Pearl………………… 80001037 32………. Ash Lip, Summit Classic, Ivory…………………….80000388 ………….. Ash Lip, Summit Classic, Red ……………………..80000389 ………….. Ash Lip, Summit Classic, Ivory……………………. 80001039 33………. Trivet, Super/Summit Classic, Met Black………. 11260002 ………….. Trivet, Super/Summit Classic, Nickel……………. 11260003

11

15

33 30

14 13
12 12
6 7 8 9 10

16
32 5

4

21

31
17 30
18

24 SUMMIT-LE_310119-28

29 23

25
28 All parts may be ordered from your nearest Pacific Energy dealer.
Visit www.pacificenergy.net for the location of the dealer nearest you.

27

100000302

© 2017 Copyright Pacific Energy Fireplace Products LTD. Reproduction, adaptation, or translation without prior written permission is prohibited except as allowed under the copyright laws.
For Technical Support please contact your dealer
Web site: http://www.pacificenergy.net
PACIFIC ENERGY FIREPLACE PRODUCTS LTD.
2975 Allenby Rd., Duncan, B.C. V9L 6V8
Printed in Canada