WELLS WVAE30F Ventilator Hood Instruction Manual
- June 16, 2024
- WELLS
Table of Contents
- WVAE30F Ventilator Hood
- LIMITED WARRANTY STATEMENT
- ELECTRICAL SPECIFICATIONS
- FEATURES & OPERATING CONTROLS
- PRECAUTIONS AND GENERAL INFORMATION
- AGENCY LISTING INFORMATION
- INSTALLATION
- OPERATION
- CLEANING INSTRUCTIONS
- REQUIRED MAINTENANCE
- TROUBLESHOOTING SUGGESTIONS
- EXPLODED VIEW PARTS LIST
- WIRING DIAGRAM
- PARTS & SERVICE
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
SUPPLEMENTAL
OWNERS MANUAL
VENTILATOR HOOD
SECTION
FRYER MODELS
WVAE30F/ WVPE30F/ WVAE55F/ WVAE55FS
Includes
INSTALLATION
USE & CARE
EXPLODED VIEW
PARTS LIST
WIRING DIAGRAM
WVAE30F Ventilator Hood
IMPORTANT: DO NOT DISCARD THIS MANUAL
This manual is considered to be part of the appliance and is to be given to
the OWNER or MANAGER of the restaurant, or to the person responsible for
TRAINING OPERATORS of this appliance. Additional manuals are available from
your WELLS DEALER.
THIS MANUAL MUST BE READ AND UNDERSTOOD BY ALL PERSONS USING OR INSTALLING
THIS APPLIANCE. Contact your WELLS DEALER if you have any questions
concerning installation, operation or maintenance of this equipment.
LIMITED WARRANTY STATEMENT
Unless otherwise specified, all commercial cooking equipment manufactured by
Wells Manufacturing is warranted against defects in materials and workmanship
for a period of one year from the date of original installation or 18 months
from the date of shipment from our factory, whichever comes first, and is for
the benefit of the original purchaser only.
THIS WARRANTY IS THE COMPLETE AND ONLY WARRANTY, EXPRESSED OR IMPLIED IN LAW
OR IN FACT, INCLUDING BUT NOT LIMITED TO, WARRANTIES OF MERCHANTABILITY OR
FITNESS FOR ANY PARTICULAR PURPOSE, AND/OR FOR DIRECT, INDIRECT OR
CONSEQUENTIAL DAMAGES IN CONNECTION WITH WELLS BLOOMFIELD PRODUCTS. This
warranty is void if it is determined that, upon inspection by an authorized
service agency, the equipment has been modified, misused, misapplied,
improperly installed, or damaged in transit or by fire, flood or act of God.
It also does not apply if the serial nameplate has been removed, or if service
is performed by unauthorized personnel. The prices charged by Wells
Manufacturing for its products are based upon the limitations in this
warranty. Seller’s obligation under this warranty is limited to the repair of
defects without charge by a Wells Manufacturing factory authorized service
agency or one of its sub-service agencies. This service will be provided on
customer’s premises for non-portable models. Portable models (a device with a
cord and plug) must be taken or shipped to the closest authorized service
agency, transportation charges prepaid, for service. In addition to
restrictions contained in this warranty, specific limitations are shown in the
Service Policy and Procedure Guide. Wells Manufacturing authorized service
agencies are located in principal cities. This warranty is valid in the United
States and Canada and void elsewhere. Please consult your classified telephone
directory, your foodservice equipment
dealer or contact:
Wells Manufacturing
10 Sunnen Dr., St. Louis MO 63143 USA
phone314-678-6314 or fax
314-781-2714
for information and other details concerning warranty.
SERVICE POLICY AND PROCEDURE GUIDE and ADDITIONAL WARRANTY EXCLUSIONS
-
Resetting of safety thermostats, circuit breakers, over load protectors, and/or fuse replacements are not covered by this warranty unless warranted conditions are the cause.
-
All problems due to operation at voltages or phase other than specified on equipment nameplates are not covered by this warranty.
Conversion to correct voltage and/or phase must be the customer’s responsibility. -
All problems due to electrical connections not made in accordance with electrical code requirements and wiring diagrams supplied with the equipment are not covered by this warranty.
-
Replacement of items subject to normal wear, to include such items as knobs, light bulbs; and, normal maintenance functions including adjustments of thermostats, adjustment of micro switches and replacement of fuses and indicating lights are not covered by warranty.
-
Damage to electrical cords and/or plug due to exposure to excessive heat are not covered by this warranty.
-
Full use, care, and maintenance instructions supplied with each machine. Noted maintenance and preventative maintenance items, such as servicing and cleaning schedules, are customer responsibility. Those miscellaneous adjustments noted are customer responsibility. Proper attention to preventative maintenance and scheduled maintenance procedures will prolong the life of the appliance.
-
Travel mileage is limited to sixty (60) miles from an Authorized Service Agency or one of its sub-service agencies.
-
All labor shall be performed during regular working hours. Overtime premium will be charged to the buyer.
-
All genuine Wells replacement parts are warranted for ninety (90) days from date of purchase on nonwarranty equipment. This parts warranty is limited only to replacement of the defective part(s). Any use of non-genuine Wells parts completely voids any warranty.
-
Installation, labor, and job check-outs are not considered warranty and are thus not covered by this warranty.
-
Charges incurred by delays, waiting time or operating restrictions that hinder the service technician’s ability to perform service are not covered by warranty. This includes institutional and correctional facilities.
SHIPPING DAMAGE CLAIM PROCEDURE
NOTE: For your protection, please note that equipment in this shipment
was carefully inspected and packaged by skilled personnel before leaving the
factory. Upon acceptance of this shipment, the transportation company assumes
full responsibility for its safe delivery. IF SHIPMENT ARRIVES DAMAGED:
- VISIBLE LOSS OR DAMAGE: Be certain that any visible loss or damage is noted on the freight bill or express receipt, and that the note of loss or damage is signed by the delivery person.
- FILE CLAIM FOR DAMAGE IMMEDIATELY: Regardless of the extent of the damage.
- CONCEALED LOSS OR DAMAGE: if damage is unnoticed until the merchandise is unpacked, notify the transportation company or carrier immediately, and file “CONCEALED DAMAGE” claim with them. This should be done within fifteen (15) days from the date the delivery was made to you. Be sure to retain the container for inspection.
Wells Manufacturing cannot assume liability for damage or loss incurred in transit. We will, however, at your request, supply you with the necessary documents to support your claim.
INTRODUCTION
Thank You for purchasing this Wells Manufacturing appliance.
Proper installation, professional operation and consistent maintenance of this
appliance will ensure that it gives you the very best performance and a long,
economical service life.
This supplemental manual contains information and instructions pertinent to
the hood section of this ventless appliance, and to its use and care.
For information regarding the fryer section, please refer to the associated
fryer owners manual.
DIMENSIONS
MODEL | WIDE | DEEP | HIGH |
---|---|---|---|
ALL | 15.8″ (402 mm) | 43.7″ | |
(1110 mm) | 76.4″ |
(1941 mm)
20″ (508 mm) including manual pull station
32″ (812.8 mm) Including manual pull station and Ansul®
inspection window standoff
ELECTRICAL SPECIFICATIONS
MODEL | VOLTS | WATTS | AMPS |
---|
WFAE-30F
WVPE-30F| 208 1Ø| 9,000| 43.
240 1Ø| 9,000| 38.
208 3Ø| 9,000| 25.0 (L1, L2, L3)
240 3Ø| 9,000| 22.0 (L1, L2, L3)
WVAE-30F EU
WVPE-30F EU| 308-415V| 9,300| 15.0 (L1)
13.0 (L2 & L3) 3 (N)
WVAE-55F
VVVAE-55FS| 208 3Ø| 17,000| 47.8 (L1, L2, L3)
240 3Ø| 17,000| 41.0 (L1, L2, L3)
WVAE-55F EU
WVAE-55FS EU| 380-415V| 17,400| 26.0 (L1)
24.0 (L2 & L3) 3 (N)
FEATURES & OPERATING CONTROLS
NOTE: Items beginning with “f. …” are part of the FRYER
Items beginning with “v. …” are part of the VENTILATOR
M381 2M-301603 Owners Manual (Supplemental) NFPA Hood
ITEM | DESCRIPTION | FUNCTION |
---|---|---|
f.1 | POWER SWITCH (FILTER-OFF-FRYER) | FRYER position energizes VENTILATOR |
POWER LIGHT and BLOWER If, within 10 seconds, there is sufficient airflow for
proper operation, POWER
LIGHT will remain ON and fryer will operate.
v.2| VENTILATOR POWER LIGHT (green)| Glows when FRYER POWER SWITCH in pressed
to FRYER and adequate airflow has been proven.
v.3| CHECK FILTERS LIGHT (amber)| Glows when GREASE BAFFLE and/or HEPA FILTER
are not properly installed. When this light is lit, fryer is disabled.
v.4| REPLACE FILTERS LIGHT (amber)| Glows if either CHARCOAL FILTER or HEPA
FILTER are due for replacement. Fryer will continue to operate, but filters
must be changed in a timely manner before they clog and disable the fryer.
v.5| SERVICE REQUIRED LIGHT (red)| Glows when there is insufficient airflow
for proper operation (either CHARCOAL FILTER or HEPA FILTER or both, plugged).
When this light is lit, fryer is disabled.
v.6| VENTILATOR BLOWER| Provides ventilation airflow.
v.7| FUSIBLE LINK LOCATION| FUSIBLE LINKS provide fire protection by melting
at a pre-set temperature and activating the fire suppression system.
v.8| FIRE SUPPRESSION NOZZLE(S)| Disperse the fire suppression media.
f.9| FILTER PUMP MOTOR OVERLOAD RESET| Provides over-temperature protection
for the FILTER PUMP MOTOR. Reset manually by pressing the red button.
v.10| VENTILATOR EXHAUST COLLAR| Ventilator discharge. DO NOT BLOCK.
Contains fire damper with pre-installed 285°F (141°C) fusible link.
v.11
v.12
v.13| CHARCOAL FILTER HEPAAIR FILTER GREASE BAFFLE| See page 10.
v.14| ANSUL@ SYSTEM STATUS INDICATOR| Indicates status of Ansul@ fire
suppression system (i.e. COCKED or FIRED).
v.15| ACCESS TOAUTOLIFT MOTOR| On fryers with automatic basket lifting device
(WVAE-series) allows servicing of lift mechanism.
v.16| MANUAL PULL STATION| Allows manual discharge of fire suppression system.
Shown on left side, may also be mounted on right side. IMPORTANT: PULL STATION
must be field installed by an ANSUL@ technician.
v.17| GREASE CUP| Catches drippings from GREASE BAFFLE.
f.18| DRIP PAN| Catches any liquid draining from top of fryer section.
f.19| STABILIZER| Prevents unit from tipping backwards.
f.20| RIGID (REAR) CASTERS| Allows unit to be easily positioned by slightly
lifting front of unit.
IMPORTANT
If a remote pull station is installed, both rear casters must be replaced with
fixed legs in order to deter movement of unit.
MOVING AN APPLIANCE EQUIPPED WITH A REMOTE PULL STATION WILL DISCHARGE THE
FIRE SUPPRESSION SYSTEM.
f.21| FIXED (FRONT) LEGS| Allows the unit to be leveled.
v.22| ANSUL@ INSPECTION WINDOW| Allows the Ansul® components to be viewed
without removing the back cover (optional)
PRECAUTIONS AND GENERAL INFORMATION
WARNING: SHOCK HAZARD
All servicing requiring access to non-insulated electrical components must be
performed by a factory authorized technician.
DO NOT open any access panel which requires the use of tools. Failure to
follow this warning can result in severe electrical shock.
CAUTION: RISK OF DAMAGE
DO NOT connect or energize this appliance until all installation instructions
are read and followed. Damage to the appliance will result if these
instructions are not followed.
CAUTION: HOT SURFACE
Exposed surfaces can be hot to the touch and may cause burns.
IMPORTANT: The fryer is disabled when the filters are plugged to the
point of insufficient airflow for proper operation. Also, the fryer is
disabled if either the HEPA filter or grease baffle is removed. It is the
responsibility of the store management to maintain sufficient spares of HEPA
air filters to avoid prolonged shutdown of the fryer when this filter is
expended. Charcoal and HEPA air filters cannot be cleaned. Wells Manufacturing
assumes no liability for loss of business due to filter related shutdown.
This ventilator hood is part of an engineered system and is intended for use
in commercial establishments only.
This ventilator and attendant fryer are intended to prepare food for human
consumption. No other use is recommended or authorized by the manufacturer or
its agents.
Operators of this appliance must be familiar with the appliance use,
limitations and associated restrictions. Operating instructions must be read
and understood by all persons using or installing this appliance. This
ventilator hood system is designed to reduce odor emissions, but will not
completely eliminate all cooking odors. Air exchange rates at the installation
site must comply with the requirements of the local jurisdictional authority.
To ensure that odors do not accumulate, recommended minimum air exchange is
400 cfm into and out of the site.
Cleanliness of this appliance is essential to good sanitation. Read and follow
all included cleaning instructions and schedules to ensure the safety of the
food product.
Disconnect this appliance from electrical power before performing any
maintenance or servicing.
This appliance is not jet stream approved. Do not direct water jet or steam
jet at this appliance, or at any control panel or wiring. Do not splash or
pour water on, in or over any controls, control panel or wiring.
Do not wash floor around this appliance with water or steam jet. Do not
attempt to wash charcoal or HEPA air filters. Water will cause their immediate
failure and disable the fryer.
Exposed surfaces of this appliance can be hot to the touch and may cause
burns.
Cooking oil will be very hot when in use. Contact will cause severe injury.
Wear appropriate heat protective apron and gloves when using this fryer.
Do not operate this appliance if the control panel is damaged. Do not operate
solid state versions of this appliance if the keypad section of the control
panel is torn or broken. Call your Authorized Wells Service Agent for service.
Avoid storing flammable or combustible materials in, on or near the appliance.
The technical content of this manual, including any wiring diagrams,
schematics, parts breakdown illustrations and/or adjustment procedures, is
intended for use by qualified technical personnel. Any procedure which
requires the use of tools must be performed by a qualified technician.
This manual is considered to be a permanent part of the appliance. This manual
and all supplied instructions, diagrams, schematics, parts breakdown
illustrations, notices and labels must remain with the appliance if it is sold
or moved to another location.
This appliance is made in the USA. Unless otherwise noted, this appliance has
American sizes on all hardware.
AGENCY LISTING INFORMATION
This appliance conforms to NSF Standard 4 for sanitation only if installed in
accordance with the supplied Installation Instructions and maintained
according to the instructions in this manual.
This appliance is and Listed under UL File E146882.
| STD 4
---|---
| E146882
| E146882
INSTALLATION
UNPACKING & INSPECTION
Carefully remove the appliance from the carton. Remove all protective plastic
film, packing materials and accessories from the appliance before connecting
electrical power or otherwise performing any installation procedure.
Carefully read all instructions in this manual before starting any
installation.
Read and understand all labels and diagrams attached to the Fryer and to the
ventilator.
Carefully account for all components and accessories before discarding packing
materials.
COMPONENTS
1 ea. Grease baffle
1 ea. HEPA air filter
1 ea. Charcoal filter
1 ea Grease cup
1 ea. Fire suppression agent tank
1 ea. Fire suppression agent (Ansulex® Low pH) 1.5 gal.
1 ea. Fire suppression system charging cartridge
1 ea. Manual pull station kit
(includes mounting hardware – must be installed by an authorized ANSUL®
distributor only)
(as req’d) Components and accessories specific to the fryer. Store these
components in a convenient place for later use .Optional Ansul® inspection
window and equipment standards.
NOTE: DO NOT discard the carton or other packing materials until you have
inspected the appliance for hidden damage and tested it for proper operation.
Refer to SHIPPING DAMAGE CLAIM PROCEDURE on the inside front cover of this
manual.
WARNING:
RISK OF INJURY
Installation procedures must be performed by a qualified technician with
full knowledge of all applicable electrical codes. Failure can result in
personal injury and property damage.
IMPORTANT: Fire suppression system must be charged and certified by an authorized Ansul® distributor. Fryer will not operate until the fire suppression system has been charged.
WARNING: SHOCK HAZARD
All servicing requiring access to non-insulated electrical components must be
performed by a factory authorized technician.
DO NOT open any access panel which requires the use of tools. Failure to
follow this warning can result in severe electrical shock.
CAUTION: RISK OF DAMAGE
DO NOT connect or energize this appliance until all installation
instructions are read and followed. Damage to the appliance will result if
these instructions are not followed.
IMPORTANT: If a remote pull station is to be used, replace the rear
casters with fixed legs.
SERVICE TECHNICIAN INSTALLATION NOTES
Installation and start up must be performed by an Authorized Installation
Company.
Installer must complete the WARRANTY REGISTRATION / FRYER CHECKOUT form, and
record fryer installation particulars on the CUSTOMER SERVICE DATA form in
this manual.
IT IS THE RESPONSIBILITY OF THE INSTALLER TO verify that this FRYER and
VENTILATOR installation is in compliance with the specifications listed in
this manual, with local code requirements, and in accordance with the STANDARD
FOR VENTILATON CONTROL AND FIRE PROTECTION OF COMMERCIAL COOKING OPERATIONS as
detailed in N.F.P.A 96 (current edition).
Certain codes require fryers to be restrained with a TETHER or other RESTRAINT
DEVICE. It is the RESPONSIBILITY OF THE INSTALLER to check with the AUTHORITY
HAVING JURISDICTION, in order to ascertain the applicability of this
requirement to THIS SPECIFIC FRYER INSTALLATION. Any restraint device must
allow access to the back and sides of the unit to provide for servicing and
maintenance, and must not interfere with the operation of the fire suppression
system.
SETUP
Setup the appliance only on a firm, level, non-combustible surface. Verify
local codes for requirements. Concrete, tile, terrazzo or metal surfaces are
recommended. Metal over combustible material may not meet code for non-
combustible surfaces. Verify vertical clearances. Ventilator fryers require a
minimum of 96” (floor to overhead) to allow or adequate air circulation.
Verify that the VENTILATOR HOOD ASSEMBLY is properly and securely assembled to
the FRYER before beginning the installation procedure. Ventilator may have
become dislodged during shipping or unpacking.
Verify that the unit sits firmly ON ALL FOUR LEGS / CASTERS. With a spirit
level, check that the appliance is level front-to-back and side-to-side. With
the adjustable legs, adjust as required to level the appliance. In order to
prevent tipping, legs must be adjusted such that all four legs / casters are
in firm contact with the floor. Adjust rear stabilizer bars (see item f.19,
page 2) to within 1/4” (6 mm)of floor to allow unit to be moved without
tipping backwards. Refer to the Installation Instruction Sheet for required
clearances. Maintain required clearances between the appliance and adjacent
combustible surfaces.
Inspection Window
For units equipped with the Ansul® component inspection window, install the
equipment stand-off bracket
ELECTRICAL INSTALLATION
Refer to the nameplate on the front of the fryer. Verify ELECTRICAL SERVICE
POWER. Voltage and phase must match the nameplate specifications, and
available electrical service amperage must meet or exceed the specifications
listed on page 1 of this manual.
- Wiring must be no less than12 ga. solid copper wire, rated for at least 75ºC.
- Wire gauge, insulation type and temperature rating , as well as type, size and construction of conduit, must meet or exceed applicable specifications of local codes and of the National Electrical Code.
Fryers are shipped from the factory wired for 3Ø electrical service.
Refer to the three-phase wiring diagram included with this fryer, and verify
that field wiring conforms to this diagram .
NOTE: 30# FRYERS are FIELD CONVERTIBLE to 1Ø.
If single-phase operation is required, refer to the 3-phase to 1-phase
Instructions included with the FRYER, and verify that both internal wiring and
field wiring conform to the included single-phase wiring diagram.
WARNING SHOCK HAZARD
Electrical connections must be made by a licensed electrician.
CAUTION: SHOCK HAZARD
The ground lug of this appliance must be connected to a suitable building
ground.
IMPORTANT: WVAE-55F and WVAE55FS units MUST NOT BE CONVERTED TO SINGLE
PHASE OPERATION.
Conversion of these units to single phase operation invalidates the UL listing
and will void the warranty.
IMPORTANT: Contact a licensed electrician to install and connect
electrical power to the appliance.
IMPORTANT: Damage due to being connected to the wrong voltage or phase is
NOT covered by warranty.
DANGER FIRE HAZARD
Fire suppression system must be charged and certified by an authorized Ansul®
distributor.
DO NOT attempt to modify or bypass the fire suppression system.
An uncontrolled fire can cause serious injury or death.
NOTE: If the fire suppression system is discharged, a buzzer will sound
continuously. The fryer will remain inoperable until the fire suppression
system is serviced, recharged and reset by an authorized Ansul® distributor.
Charging of the Ansul® Fire Suppression system must be in accordance with
Ansul® Design, Installation, Recharge and Maintenance Manual, #418087.
NOTE: If a REMOTE MANUAL PULL STATION is installed, moving the FRYER for
servicing may cause the Ansul® system to discharge. In this case, the unit
must only be installed with four fixed legs (i.e. remove rear casters and
replace with legs). Additional legs may be ordered through an Authorized Wells
Service Agency. See page 19.
FIRE SUPPRESSION SYSTEM INSTALLATION
FIRE SUPPRESSION SYSTEM is comprised of a container of Ansulex® Low pH liquid
fire suppression media, a system pressurization canister and associated
plumbing and controls.
Two FUSIBLE LINKS are utilized for automatic actuation, and a MANUAL PULL
STATION for manual actuation. Two NOZZLES disperse the fire suppression media.
The hood is supplied with a field installed MANUAL PULL STATION, which must be
set-up at the time of the fryer installation by an authorized Ansul®
distributor. See below and following page for installation details.
If the fryer is installed such that the supplied manual pull station cannot be
installed, a REMOTE MANUAL PULL STATION may be required by local codes. Any
such remote manual pull station must be installed by an authorized Ansul®
distributor in accordance with the AUTHORITY HAVING jURISDICTION.
When the fire suppression system discharges, fryer heating element(s) and
controls are de-energized, and fire suppression media discharged.
Fire supression media will form an emulsion designed to both smother and cool
the oil.
The PRIMARY 450ºF FUSIBLE LINK is located on the frypot. This link will melt
and discharge the fire suppression system should both the TEMPERATURE CONTROL
THERMOSTAT and the HIGH LIMIT CONTROL fail. The SECONDARY 280ºF FUSIBLE LINK
is located in the filter plenum, and will protect against a fire in the
plenum.
Either link melting will discharge the fire suppression media through both
NOZZLES, and cause a buzzer to sound.
The MANUAL PULL STATION and any similar REMOTE MANUAL PULL STATION will
activate the fire suppression system when the ring on the pull station is
pulled to its full extent.
DANGER BURN HAZARD HOT OIL SPILL
Any additional remote pull station must not be installed on the front or sides
of the fryer forward of the ventilator side panels.
Discharge of the fire extinguishing system into hot oil will cause hot foam to
spill over from the frypot.
Serious burns and other injuries can result from contact with hot oil and from
slipping in spilled oil.
Exclusive Anti-Fire System In the unlikely event that both the temperature
control thermostat and hi-limit detector fail, and the oil temperature climbs
above the safety limit, the fire suppression system will discharge, cooling
the oil below the oil’s (approximately) 540ºF auto-ignition temperature, and
preventing a fire from occurring.
NOTE: The GREASE BAFFLE and HEPA AIR FILTER actuate magnetic reed
switches when they are in their proper positions. They must be properly
installed or the fryer heater elements will not be energized.
NOTE: Remove the protective plastic bag from the optional charcoal filter
before installing. Installing the filter without removing the plastic bag will
block the air flow. This will cause the ventilator to shut down 10 seconds
after start-up, and the fryer will not heat.
WARNING SLIP AND FALL HAZARD
DO NOT operate fryer unless drip pan is installed. Oil will drip onto floor
creating a slipping hazard.
CAUTION BURN HAZARD
DO NOT operate fryer unless grease cup is installed.
Moisture dripping into hot oil will cause hot oil to splatter.
FILTER INSTALLATION
Remove the protective plastic bag from charcoal filter before installing.
Note air flow direction arrow on each filter, and verify that arrow points
toward plenum when filter is properly installed.
Install filters by inserting top of each into top filter support inside hood
assembly. Pivot bottom of each filter toward rear of hood assembly and drop it
into its respective bottom filter support. Seat each filter firmly into the
bottom filter support.
Install CHARCOAL FILTER first, followed by HEPA AIR FILTER.
Install GREASE BAFFLE last.
GREASE CUP & DRIP PAN INSTALLATION Install GREASE CUP into brackets below
grease baffle.
Note: Failure to install GREASE CUP will allow grease and moisture from
GREASE BAFFLE to drop into FRYPOT, creating both a SAFETY HAZARD (hot oil
splatter) and a HEALTH HAZARD (contamination of the cooking oil).
Install DRIP PAN into mounting bracket behind fryer door at lower right front
of fryer.
Note: Failure to install DRIP PAN will allow grease, moisture and other
liquids that accumulate on the fryer top panel to drip onto floor, creating
both a SAFETY HAZARD (slip and fall hazard) and a HEALTH HAZARD (substance
capable of supporting bacteria).
OPERATION
NOTE: Fryer must be operated in accordance with the instructions in the
accompanying FRYER OPERATION MANUAL. During normal operation, VENTILATOR POWER
ON light will be the only light illuminated on VENTILATOR WARNING LIGHT PANEL.
If the CHECK FILTERS light illuminates, check both GREASE BAFFLE and the HEPA
AIR FILTER for proper installation.
If REPLACE FILTERS light illuminates, replace both HEPA AIR FILTER and
CHARCOAL FILTER. Always replace both filters at the same time.
NOTE: REPLACE FILTERS light is a warning that filters are nearing the end
of their service life. The fryer will continue to operate for a period of time
after REPLACE FILTER LIGHT turns ON to allow continued fryer operation through
a peak period. However, filters must be replaced within a short time period or
they will clog, disabling the fryer.
If SERVICE REQUIRED light illuminates, filters are restricted to the point of
insufficient airflow for proper operation. Fryer is shut down until the
underlying clogged filter situation has been corrected. Normally, replacing
both HEPA AIR FILTER and CHARCOAL FILTER will remedy the condition. Reset the
unit by turning FRYER POWER SWITCH to OFF, then back to FRYER. A failure of
incoming electric power will cause a shut down of the unit. Reset the unit by
turning the FRYER POWER SWITCH to OFF, then back to FRYER.
CAUTION: HOT SURFACE
Exposed surfaces can be hot to the touch and may cause burns.
CAUTION: SHOCK HAZARD
DO NOT splash or pour water or grease onto control panel or wiring.
IMPORTANT: The fryer is disabled when REPLACE FILTERS light is
illuminated. Note that the fryer cannot operate if the HEPA air filter is
removed. It is the responsibility of the store management to maintain
sufficient spares of HEPA air filters to avoid prolonged shutdown of the fryer
when this filter is expended.
Charcoal and HEPA air filters cannot be cleaned. Wells Manufacturing assumes
no liability for loss of business due to filter related shutdown.
CLEANING INSTRUCTIONS
CAUTION: HOT SURFACE
Exposed surfaces can be hot to the touch and may cause burns.
CAUTION: SHOCK HAZARD
DO NOT splash or pour water or grease onto control panel or wiring.
PRECAUTIONS: Disconnect unit from electric power and allow to cool Cover
frypot to prevent oil contamination
FREQUENCY: Weekly
TOOLS: Mild detergent, clean non-abrasive towels
NOTE: Ventilator section to be cleaned in conjunction with fryer Refer to Fryer Operation Manual for fryer cleaning instructions.
-
Disconnect unit from electric power and allow to cool.
Cover frypot to prevent oil contamination. -
Remove GREASE BAFFLE, GREASE CUP and DRIP PAN.
-
Empty GREASE CUP and DRIP PAN into an appropriate grease collection receptacle.
-
Clean GREASE BAFFLE, GREASE CUP and DRIP PAN in a sink or dishwasher using mild detergent and warm water.
-
Dry components with a clean non-abrasive cloth. Reinstall DRIP PAN, GREASE CUP, and GREASE BAFFLE.
-
Wipe exterior of fryer and ventilator with a clean cloth moistened with warm water and mild detergent. Rinse by wiping with a clean cloth moistened with warm water.
-
Uncover the frypot and reconnect unit to electric power.
Procedure is complete
PRECAUTIONS: Disconnect unit from electric power and allow to cool Cover
frypot to prevent oil contamination
FREQUENCY: Monthly
TOOLS: Mild detergent, clean non-abrasive towels
NOTE: Ventilator section to be cleaned in conjunction with fryer Refer to Fryer Operation Manual for fryer cleaning instructions.
-
Disconnect unit from electric power and allow to cool.
Cover frypot to prevent oil contamination. -
Remove GREASE BAFFLE, HEPA AIR FILTER and CHARCOAL FILTER.
-
Wipe interior of ventilator with a clean cloth moistened with warm water and mild detergent. Rinse by wiping with a clean cloth moistened with warm water. DO NOT clean by spraying.
-
Dry ventilator thoroughly with a clean non-abrasive cloth. Reinstall CHARCOAL FILTER, HEPA AIR FILTER and GREASE BAFFLE..
-
Uncover the frypot and reconnect unit to electric power.
Procedure is complete
CAUTION: HOT SURFACE
Exposed surfaces can be hot to the touch and may cause burns.
CAUTION: SHOCK HAZARD
DO NOT splash or pour water or grease onto control panel or wiring.
IMPORTANT: DO NOT wash HEPA air filter or CHARCOAL filter. Washing these
filters will clog them, and cause fryer to be disabled.
IMPORTANT: DO NOT clean interior of ventilator by spraying. Spraying can
contaminate the cooking oil, and may cause internal damage to the blower,
operation proofing system and/or fire suppression system. Clean by wiping
only.
REQUIRED MAINTENANCE
IMPORTANT: A signed and dated FRYER HOOD MAINTENANCE LOG must be
maintained on the premises, and shall be made available for inspection by the
authority having jurisdiction upon request. See page 15.
USE AND MAINTENANCE SHALL BE IN ACCORDANCE WITH THE STANDARD FOR VENTILATION
CONTROL AND FIRE PROTECTION OF COMMERIAL COOKING OPERATIONS, N.F.P.A. 96
(current edition).
3-MONTH MAINTENANCE:
Thoroughly clean entire HOOD PLENUM and BLOWER section.
6-MONTH MAINTENANCE:
Inspection and testing of total operation including FIRE DAMPER and all SAFETY
INTERLOCKS shall be performed by qualified service personnel.
All FIRE SUPPRESION SYSTEM actuation components including MANUAL PULL STATION
and any REMOTE MANUAL PULL STATION must be inspected for proper operation in
accordance with the maintenance schedule published in ANSUL® R-102 SYSTEM
DESIGN, INSTALLATION, RECHARGE AND MAINTENANCE MANUAL (418087).
On WVAE-Model fryers, open the rear cover access door and lubricate the LIFT
WORM threads with molybdenum disulfide grease (see item v.15 page 2) .
ANNUAL (12-MONTH) MAINTENANCE: FIRE SUPRESSION SYSTEM FUSIBLE LINKS must be
replaced.
NOZZLES and MANUAL PULL STATION must be cleaned in accordance with ANSUL®
R-102 SYSYTEM DESIGN, INSTALLATION, RECHARGE AND MAINTENANCE MANUAL (418087).
12-YEAR MAINTENANCE:
The FIRE SUPRESSION AGENT TANK and ¼” FLEX HOSE must be HYDROSTATICALLY
TESTED, and the FIRE EXTINGUISHING AGENTmust be REPLACED in accordance with
the maintenance schedule published in ANSUL® R-102 SYSTEM (STANDARD UL 300
LISTED).
This maintenance to be performed by qualified Ansul® service personnel only.
TROUBLESHOOTING SUGGESTIONS
Problem | Possible Cause | Suggested Remedy |
---|---|---|
Unit will not operate (no indicators lights lit) | Disconnected from electric | |
power | Reconnect to electric power Reset circuit breaker for unit | |
Unit will not operate (buzzer sounds) | Fire suppression system not set |
Contact an authorized Ansul® distributor for repairs
CHECK FILTER light lit| HEPA air filter or grease baffle not in position|
Properly install HEPA filter and grease baffle
REPLACE FILTERS light lit| HEPA air filter and charcoal filters nearing end of
service life| Arrange to replace both HEPA and charcoal filters in a timely
manner
SERVICE REQUIRED light lit (fryer not operating)| HEPA air filter and charcoal
filters plugged| Replace both HEPA and charcoal filters
Fire damper in exhaust collar has closed| Contact an authorized Wells service
agent for repairs
One or more vacuum sensing lines or ports plugged| Contact an authorized Wells
service agent for repairs
NOTE: If, after 10 seconds, there is insufficient airflow for proper
operation, SERVICE REQUIRED light will illuminate and fryer will be de-
energized.
_ Press FRYER POWER SWITCH to OFF, then back to FRYER to reset system.
NOTE: FILTERS are the only user serviceable components in this ventilator hood system. For all problems that cannot be remedied by servicing the filters, contact: Fryer or ventilator section – authorized Wells service agency Fire suppression system – authorized Ansul® distributor
IMPORTANT: Contact ANSUL® for fire suppression system installation, set-
up and service:
Ansul Incorporated 1-800-TO-ANSUL
(1-800-862-6785)
One Station Street Marinette, WI 54143-2542
website http://www.ansul.com
IMPORTANT:
Parts used in the Ansul® fire suppression system are not serviceable by the
owner/operator.
Procedures for servicing fire suppression equipment are described in: ANSUL®
R-102 SYSTEM DESIGN, INSTALLATION, RECHARGE AND MAINTENANCE MANUAL (418087,
current edition)
NOTE: ANSUL® Manual 41807 and Wells Bulletin 301646 are intended for use by authorized Ansul® service personnel only.
EXPLODED VIEW PARTS LIST
CABINET AND HOOD SECTION COMPONENTS
VACUUM AND INTERLOCK SYSTEM COMPONENTS
FIRE DETECTION AND SUPPRESSION SYSTEM COMPONENTS
FOR USE ONLY BY AUTHORIZED ANSUL© SERVICE PERSONNEL
Refer to Ansul© part no. 418078-05
R-102 Restaurant Fire Suppression System Design, Installation, Recharge and
Maintenance
WIRING DIAGRAM
WVAE-55F & VAE-55F
3Ø, 208V OR 240V, 17KW
WIRING DIAGRAM FOR VPE-30F & WVPE-30F
208V OR 240V, 9KW
SINGLE OR 3 PHASE – WIRED 3 PHASE AS SHOWN
WELLS MANUFACTURING CO.
FRYER HOOD MAINTENANCE LOG
TO BE PERFORMED BY QUALIFIED SERVICE PERSONNEL ONLY
Internet Address: http://www.ansul.com
ANSUL INCORPORATED, ONE STANTON STREET, MARINETTE, WI54143-2542
715-735-7411 Form No. F-90160-6 ©1999
Ansul incorporated
PARTS & SERVICE
DESCRIPTION
LEG KIT, REAR, WVAE, WVPE HEPA AIR FILTER CHARCOAL FILTER
PART NO.
WS-22692
WS-22402
WS-22403
IMPORTANT: Use only factory authorized service parts and replacement filters. For factory authorized service, or to order factory authorized replacement parts, contact your Wells authorized service agency, or call: Wells Manufacturing 10 Sunnen Dr., St. Louis MO 63143 USA Service Dept. phone: 314-678-6314 fax: 314-781-2714 Service Parts Department can supply you with the name and telephone number of the WELLS AUTHORIZED SERVICE AGENCY nearest you.
CUSTOMER SERVICE DATA
please have this information available if calling for service
RESTAURANT ____ LOCATION
INSTALLATION DATE ____ TECHNICIAN
SERVICE COMPANY ____
ADDRESS ____ STATE __ ZIP__
TELEPHONE NUMBER ()-_
EQUIPMENT MODEL NO. ___
EQUIPMENT SERIAL NO. ___
VOLTAGE: (check one) 208 240 380-415
Wells Bloomfield proudly supports CFESA
Commercial Food Equipment Service Association
SERVICE TRAINING – QUALITY SERVICE
CUSTOMER SATISFACTION
WELLS MANUFACTURING
10 Sunnen Dr., St. Louis, MO 63143
telephone: 314-678-6314
fax: 314-781-2714
www.wellsbloomfield.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>