WELLS WVU-48 Universal Ventless Hood Owner’s Manual

June 13, 2024
WELLS

JobItem No.
Universal Ventless Hood
MODEL WVU-48

Model WVU-48

DESCRIPTION

Wells Universal hoods are Certified Type-1 compliant, UL710B approved recirculation hood systems and feature completely self-contained air filtration and fire-suppression systems. They do not require venting outside making it possible to cook in non- traditional locations or when traditional Type-1 hoods and ductwork are impractical, restricted or too expensive. Operators can mix and match various electric cooking equipment under the hood such as fryers, ovens, griddles, steamers and more – providing greater flexibility and through-put.

SPECIFICATIONS

Fire Protection – Completely self contained ANSUL® R-102 system includes ANSUL® tank, nitrogen cartridge, ANSUL® sopanifier, piping, heat sensors, ANSUL® drops, nozzles, and movable manual pull station. Manual pull can be relocated to the egress  position or an additional station can be added by an authorized ANSUL® representative. Front access for easy fire system maintenance. Fire protection system meets NFPA 96 Chapter 13. Fire protection system must be charged and certified by ANSUL®  Authorized distributor after installation and before first use (operator’s responsibility).
Filtration — Completely self-contained filtration process reduces emissions below that allowed in NFPA 96 and ANSI UL710B using the EPA 202 test method and includes stainless steel grease baffle filter with grease cup, fiberglass pre-filters, HEPA (High- Efficiency Particulate Air) filter/ carbon-charcoal filter pack. Al filters are easily removable with out tools. Air flow sensors continually monitor air flow optimizing performance and grease removal while aninterlock system will not allow cooking appliances to  function if filters are missing, clogged or in the event of a fire.

Cooking Appliances – Only electrically heated appliances are acceptable for installation. Cooking equipment is optional from Wells or other manufacturers. Appliances must be installed as per manufacturers instructions and controlled thru the hood equipment  shut-off interface through a customer supplied contractor which will disable cooking equipment in the event of fire or hood malfunction. For size, temperature and KW limits see back page or manual.
Exhaustand Air Flow – Exhaust air may be horizontal or vertical. Hoods are shipped for horizontal discharge and are field convertible for vertical discharge. Typical airflow is 1,500 CFM. A minimum of 800 cubic feet of fresh air per minute is recommended both  in and out of the cooking area to ensure the dilution of cooking aromas.

STANDARD FEATURES

  • Completely self-contained, 4-stage filtration system
  • Completely self-contained fire protection system
  • Interlock system will disable cooking appliances if filters are missing, clogged or in the event of a fire
  • Airflow sensors continually monitor airflow for optimizing performance and grease removal
  • llluminated early-warning system to monitor filter replacement
  • Completely self-contained filtration process reduces emissions below that allowed in NFPA 96 and ANSI UL710B using the EPA 202 test method
    [ Three LED lights producing 495 lumens each for improved visibility – light color temperature (cool white): 6000K
    [ Stainless steel construction for strength, durability and ease of cleaning
    [ Fits through a 36″ wide door opening 16″ to 8” adjustable legs (adjustable by 2″ for leveling)
    (1 Universal systems are movable making them ideal for leased properties (3 Available in 208/240V, 10
    [ Limited one-year parts and one year labor warranty

OPTIONS & ACCESSORIES

  1. Pre-filters
  2. HEPA / carbon-charcoal filter packs

CERTIFICATIONS

UL710B CATEGORY YZCT
RECRCULATING SYSTEM
FILENO. MHas408

GENERAL LAYOUT DATA SANITATION

MODEL WVU-48 UNIVERSAL VENTLESS HOOD SYSTEM

UL CAT. YZCT RECIRCULATING SYSTEM FILE NO. MH48408
SPECIAL ENVIRONMENTAL NOTICE: THE HOOD SYSTEM IS DESIGNED TO REDUCE EMISSIONS BUT WILL NOT COMPLETELY ELIMINATE COOKING AROMAS. AIR EXCHANGE AT
THE INSTALLATION SITE MUST COMPLY WITH REQUIREMENTS OF THE LOCAL JURISDICTIONAL AUTHORITY. A MINIMUM OF 800 CUBIC FEET OF FRESH AR PER MINUTE
INTO THE AREA IS RECOMMENDED TO ENSURE ADEQUATE DILUTION.

VOLTAGE
AC 60 HZ| AMPS
1 PH.| HORSE
POWER| TYPICAL
AIRFLOW| MAX. GREASE EMMISSIONS| CLEARANCES TO COMBUSTIBLES| UNDER HOOD
LED LIGHTING
---|---|---|---|---|---|---
208/240| 4.| 3/4| 1500 CFM| .0024 LB/HR/FT| SEE DRAWING| 1500 LUMENS

HOOD SYSTEM INSTALLATION – STAND MOUNT – REGARDLESS OF EQUIPMENT UNDER HOOD.

WELLS WVU-48 Universal Ventless Hood - Hood System

Table: Meights and 3hipping Information

Meights| Carton Dimensions| Crate 3ise
3hipping Meight| Insta led Meight| Midth| Depth| Meight
Pounds| kg| Pounds| kg| Inches| mm| Inches| mm| Inches| mm| Cubic Eeet| Cubic Meters
1189| 501| F98| 363| 60| 1520| F0| 1FF8| 55.5| 1010| 1F9| 5.06

THE HOOD AND ALL UNDER HOOD APPLIANCES MUST BE INSTALLED IN ACCORDANCE WITH THE STANDARD FOR VENTILATION CONTROL AND FIRE PROTECTION OF COMMERCIAL COOKING OPERATIONS NFPA 96, THE NATIONAL  ELECTRIC CODE NFPA 70 AND ALL LOCAL CODES WHERE APPLICABLE. ALL UNDER HOOD APPLIANCES MUST BE INSTALLED AS PER MANUFACTURER INSTRUCTIONS AND CONTROLLED BY THE HOOD EQUIPMENT SHUTOFF INTERFACE  THROUGH A CUSTOMER SUPPLIED CONTACTOR. SEE THE INSTRUCTION MANUAL FOR INTERFACE CONNECTION OPTIONS. APPLIANCES MUST MEET EQUIPMENT PARAMETERS DESCRIBED ABOVE. ONLY ELECTRICALLY HEATED  APPLIANCES ARE ACCEPTABLE FOR INSTALLATION. PRIOR TO OPERATION THE FIRE SUPPRESSION SYSTEM MUST BE CHARGED AND CERTIFIED BY AN ANSUL® AUTHORIZED DISTRIBUTOR. ADEQUATE SIDE CLEARANCE MUST BE  PROVIDED FOR SUPPLY CONNECTION AND SUPPRESSION MANUAL PULL ACCESS.
EXHAUST IS SHPPED FOR HORIZONTAL DISCHARGE AND FIELD CONVERTIBLE FOR VERTICAL DISCHARGE.

CENERAL LAYOUT DATA SANITATION

MODEL WVU—48 UNIVERSAL VENTLESS HOOD SYSTEM

VOLTACL
AC 60 H5| AUPS 1 PH.| HORSL POMLR| 1$PICAL AIRFLOM| UAX. CRLASL LUUISSIONS| CLLARANCLS 1O COU8USTI8LLS| YNDLR HOOD LLD LICHTINC
---|---|---|---|---|---|---
 208/240|  3.5|  3/4|  1500 CFU|  .0024 L8/HR/F1|  SLL DRAMINC|  1500 LYULNS

UL CAT. YZCT RECIRCULATING SYSTEM FILE NO. MH48408
SPECIAL ENVIRONMENTAL NOTICE: THE HOOD SYSTEM IS DESIGNED TO REDUCE EMISSIONS BUT WILL NOT COMPLETELY ELIMINATE COOKING AROMAS. AR EXCHANGE AT THE INSTALLATION SITE MUST COMPLY WITH  REQUIREMENTS OF THE LOCAL JURISDICTIONAL AUTHORTY. A MINIMUM OF 80O CUBIC FEET OF FRESH AR PER MINUTE INTO THE AREA IS RECOMMENDED TO ENSURE ADEQUATE DILUTION.

HOOD SYSTEM INSTALLATION — EQUIPMENT PLACEMENT REQUIREMENTS

WELLS WVU-48 Universal Ventless Hood - Hood System 2

TABLE: APPLIANCE PLACEMENT REQUIREMENTS| | | |
---|---|---|---|---
APPLIANCE TYPE| MAXIMUM
KW/FT| MAXIMUM
COOKING
TEMPERATURE
(°F)| MAXIMUM
SINGLE
APPLIANCE
HEATED
COOKING
SURFACE LENGTH
(IN.)| DIMENSION A (IN.)
MINIMUM| DIMENSION B
(IN.)
MINIMUM| DIMENSION B
(IN.)
MAXIMUM| DIMENSION C
(IN.)
MINIMU M
FRYER| 16.9| 400| 18| 24 (EDGE OF OIL)| 37| 42| 0
GRIDDLE| 5.5| 450| 36| 21 (EDGE OF HEATED PLATE)| 37| 42| 1
RANGE (2) / HOTPLATE| 5.5| NA| 48| 18 (EDGE OF HEATED  PLATEN)| 37| 42| 1
WOK| 7.0| NA| 48| 21 (EDGE OF HEATED  SURFACE)| 37| 42| 0
VERTICAL BROILER| 7.0| NA| 25| 20 (EDGE OF HEATED  SURFACE)| 10| NA| 0
OVEN| NA| 575| 48| 6 (EDGE OF FRONT DOOR)| 8| NA| 0
BRAISING PAN / SKILLET (1)| 5.| 550| 48| 14 (EDGE OF HEATED  SURFACE)| 37| 42| 0
CONVECTION OVEN| NA| 575| 48| 6 (FRONT EDGE OF DOOR)| 8| NA| 0
STEAMER / COMBI OVEN| NA| 575| 48| 6 (TOP EDGE OF DOOR)| 20| NA| 0
STEAM JACKETED KETTLE| 16.9| 450| 48| 14 (EDGE OF HEATED  SURFACE)| 30| 42| 0
SANDWICH GRILL (1)| 4.5| 550| 36| 18 (EDGE OF HEATED  PLATEN)| 30| 42| 0
CONVEYOR OVEN| 4.5| NA| 23| 6 (EDGE OF HEATED SURFACE)| 20| 42| 0

  1. LID OF THE APPLIANCE MUST NOT INTERFERE WITH SUPPPRESSION NOZZLE DISCHARGE PATTERN.
  2. PLUSOVEN KW IF APPLICABLE

THE HOOD AND ALL UNDER HOOD APPLIANCES MUST BE INSTALLED IN ACCORDANCE WITH THE STANDARD FOR VENTILATION CONTROL AND FIRE PROTECTION OF COMMERCIAL COOKING OPERATIONS NFPA 96, THE NATIONAL  ELECTRIC CODE NFPA 70 AND ALL LOCAL CODES WHERE APPLICABLE. ALL UNDER HOOD APPLIANCES MUST BE INSTALLED AS PER MANUFACTURER INSTRUCTIONS AND CONTROLLED BY THE HOOD EQUIPMENT SHUTOFF INTERFACE  THROUGH A CUSTOMER SUPPLIED CONTACTOR. SEE THE INSTRUCTION MANUAL FOR INTERFACE CONNECTION OPTIONS. APPUANCES MUST MEET EQUIPMENT PARAMETERS DESCRIBED ABOVE. ONLY ELECTRICALLY HEATED  APPLIANCES ARE ACCEPTABLE FOR INSTALLATION. PRIOR TO OPERATION THE FIRE SUPPRESSION SYSTEM MUST BE CHARGED AND CERTIFIED BY AN ANSUL® AUTHORIZED DISTRBUTOR. ADEQUATE SIDE CLEARANCE MUST BE  PROVIDED FOR SUPPLY CONNECTION AND SUPPRESSION MANUAL PULL ACCESS.
EXHAUST IS SHIPPED FOR HORIZONTAL DISCHARGE AND FIELD CONVERTIBLE FOR VERTICAL DISCHARGE.

WELLS MANUFACTURING 265
HOBSON ST. SMITHVILLE, TN
37166 USA
NOTE: SPACFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE.
SK2547 REV H (08-22)