DESCRIPTION
Wells Universal hoods are Certified Type-1 compliant, UL710B approved recirculation hood systems and feature completely self-contained air filtration and fire-suppression systems. They do not require venting outside making it possible to cook in non- traditional locations or when traditional Type-1 hoods and ductwork are impractical, restricted or too expensive. Operators can mix and match various electric cooking equipment under the hood such as fryers, ovens, griddles, steamers and more – providing greater flexibility and through-put.
SPECIFICATIONS
Fire Protection – Completely self contained ANSUL® R-102 system includes
ANSUL® tank, nitrogen cartridge, ANSUL® sopanifier, piping, heat sensors,
ANSUL® drops, nozzles, and movable manual pull station. Manual pull can be
relocated to the egress position or an additional station can be added by an
authorized ANSUL® representative. Front access for easy fire system
maintenance. Fire protection system meets NFPA 96 Chapter 13. Fire protection
system must be charged and certified by ANSUL® Authorized distributor after
installation and before first use (operator’s responsibility).
Filtration — Completely self-contained filtration process reduces emissions
below that allowed in NFPA 96 and ANSI UL710B using the EPA 202 test method
and includes stainless steel grease baffle filter with grease cup, fiberglass
pre-filters, HEPA (High- Efficiency Particulate Air) filter/ carbon-charcoal
filter pack. Al filters are easily removable with out tools. Air flow sensors
continually monitor air flow optimizing performance and grease removal while
aninterlock system will not allow cooking appliances to function if filters
are missing, clogged or in the event of a fire.
Cooking Appliances – Only electrically heated appliances are acceptable for
installation. Cooking equipment is optional from Wells or other manufacturers.
Appliances must be installed as per manufacturers instructions and controlled
thru the hood equipment shut-off interface through a customer supplied
contractor which will disable cooking equipment in the event of fire or hood
malfunction. For size, temperature and KW limits see back page or manual.
Exhaustand Air Flow – Exhaust air may be horizontal or vertical. Hoods are
shipped for horizontal discharge and are field convertible for vertical
discharge. Typical airflow is 1,500 CFM. A minimum of 800 cubic feet of fresh
air per minute is recommended both in and out of the cooking area to ensure
the dilution of cooking aromas.
STANDARD FEATURES
- Completely self-contained, 4-stage filtration system
- Completely self-contained fire protection system
- Interlock system will disable cooking appliances if filters are missing, clogged or in the event of a fire
- Airflow sensors continually monitor airflow for optimizing performance and grease removal
- llluminated early-warning system to monitor filter replacement
- Completely self-contained filtration process reduces emissions below that allowed in NFPA 96 and ANSI UL710B using the EPA 202 test method
[ Three LED lights producing 495 lumens each for improved visibility – light color temperature (cool white): 6000K
[ Stainless steel construction for strength, durability and ease of cleaning
[ Fits through a 36″ wide door opening 16″ to 8” adjustable legs (adjustable by 2″ for leveling)
(1 Universal systems are movable making them ideal for leased properties (3 Available in 208/240V, 10
[ Limited one-year parts and one year labor warranty
OPTIONS & ACCESSORIES
- Pre-filters
- HEPA / carbon-charcoal filter packs
CERTIFICATIONS
UL710B CATEGORY YZCT
RECRCULATING SYSTEM
FILENO. MHas408
GENERAL LAYOUT DATA SANITATION
MODEL WVU-48 UNIVERSAL VENTLESS HOOD SYSTEM
UL CAT. YZCT RECIRCULATING SYSTEM FILE NO. MH48408
SPECIAL ENVIRONMENTAL NOTICE: THE HOOD SYSTEM IS DESIGNED TO REDUCE EMISSIONS
BUT WILL NOT COMPLETELY ELIMINATE COOKING AROMAS. AIR EXCHANGE AT
THE INSTALLATION SITE MUST COMPLY WITH REQUIREMENTS OF THE LOCAL
JURISDICTIONAL AUTHORITY. A MINIMUM OF 800 CUBIC FEET OF FRESH AR PER MINUTE
INTO THE AREA IS RECOMMENDED TO ENSURE ADEQUATE DILUTION.
VOLTAGE
AC 60 HZ| AMPS
1 PH.| HORSE
POWER| TYPICAL
AIRFLOW| MAX. GREASE EMMISSIONS| CLEARANCES TO COMBUSTIBLES| UNDER HOOD
LED LIGHTING
---|---|---|---|---|---|---
208/240| 4.| 3/4| 1500 CFM| .0024 LB/HR/FT| SEE DRAWING| 1500 LUMENS
HOOD SYSTEM INSTALLATION – STAND MOUNT – REGARDLESS OF EQUIPMENT UNDER HOOD.
Table: Meights and 3hipping Information
Meights| Carton Dimensions| Crate 3ise
3hipping Meight| Insta led Meight| Midth| Depth| Meight
Pounds| kg| Pounds| kg| Inches| mm| Inches| mm| Inches| mm| Cubic Eeet| Cubic
Meters
1189| 501| F98| 363| 60| 1520| F0| 1FF8| 55.5| 1010| 1F9| 5.06
THE HOOD AND ALL UNDER HOOD APPLIANCES MUST BE INSTALLED IN ACCORDANCE WITH
THE STANDARD FOR VENTILATION CONTROL AND FIRE PROTECTION OF COMMERCIAL COOKING
OPERATIONS NFPA 96, THE NATIONAL ELECTRIC CODE NFPA 70 AND ALL LOCAL CODES
WHERE APPLICABLE. ALL UNDER HOOD APPLIANCES MUST BE INSTALLED AS PER
MANUFACTURER INSTRUCTIONS AND CONTROLLED BY THE HOOD EQUIPMENT SHUTOFF
INTERFACE THROUGH A CUSTOMER SUPPLIED CONTACTOR. SEE THE INSTRUCTION MANUAL
FOR INTERFACE CONNECTION OPTIONS. APPLIANCES MUST MEET EQUIPMENT PARAMETERS
DESCRIBED ABOVE. ONLY ELECTRICALLY HEATED APPLIANCES ARE ACCEPTABLE FOR
INSTALLATION. PRIOR TO OPERATION THE FIRE SUPPRESSION SYSTEM MUST BE CHARGED
AND CERTIFIED BY AN ANSUL® AUTHORIZED DISTRIBUTOR. ADEQUATE SIDE CLEARANCE
MUST BE PROVIDED FOR SUPPLY CONNECTION AND SUPPRESSION MANUAL PULL ACCESS.
EXHAUST IS SHPPED FOR HORIZONTAL DISCHARGE AND FIELD CONVERTIBLE FOR VERTICAL
DISCHARGE.
CENERAL LAYOUT DATA SANITATION
MODEL WVU—48 UNIVERSAL VENTLESS HOOD SYSTEM
VOLTACL
AC 60 H5| AUPS 1 PH.| HORSL POMLR| 1$PICAL AIRFLOM| UAX. CRLASL LUUISSIONS|
CLLARANCLS 1O COU8USTI8LLS| YNDLR HOOD LLD LICHTINC
---|---|---|---|---|---|---
208/240| 3.5| 3/4| 1500 CFU| .0024 L8/HR/F1| SLL DRAMINC| 1500 LYULNS
UL CAT. YZCT RECIRCULATING SYSTEM FILE NO. MH48408
SPECIAL ENVIRONMENTAL NOTICE: THE HOOD SYSTEM IS DESIGNED TO REDUCE EMISSIONS
BUT WILL NOT COMPLETELY ELIMINATE COOKING AROMAS. AR EXCHANGE AT THE
INSTALLATION SITE MUST COMPLY WITH REQUIREMENTS OF THE LOCAL JURISDICTIONAL
AUTHORTY. A MINIMUM OF 80O CUBIC FEET OF FRESH AR PER MINUTE INTO THE AREA IS
RECOMMENDED TO ENSURE ADEQUATE DILUTION.
HOOD SYSTEM INSTALLATION — EQUIPMENT PLACEMENT REQUIREMENTS
TABLE: APPLIANCE PLACEMENT REQUIREMENTS| | | |
---|---|---|---|---
APPLIANCE TYPE| MAXIMUM
KW/FT| MAXIMUM
COOKING
TEMPERATURE
(°F)| MAXIMUM
SINGLE
APPLIANCE
HEATED
COOKING
SURFACE LENGTH
(IN.)| DIMENSION A (IN.)
MINIMUM| DIMENSION B
(IN.)
MINIMUM| DIMENSION B
(IN.)
MAXIMUM| DIMENSION C
(IN.)
MINIMU M
FRYER| 16.9| 400| 18| 24 (EDGE OF OIL)| 37| 42| 0
GRIDDLE| 5.5| 450| 36| 21 (EDGE OF HEATED PLATE)| 37| 42| 1
RANGE (2) / HOTPLATE| 5.5| NA| 48| 18 (EDGE OF HEATED PLATEN)| 37| 42| 1
WOK| 7.0| NA| 48| 21 (EDGE OF HEATED SURFACE)| 37| 42| 0
VERTICAL BROILER| 7.0| NA| 25| 20 (EDGE OF HEATED SURFACE)| 10| NA| 0
OVEN| NA| 575| 48| 6 (EDGE OF FRONT DOOR)| 8| NA| 0
BRAISING PAN / SKILLET (1)| 5.| 550| 48| 14 (EDGE OF HEATED SURFACE)| 37| 42|
0
CONVECTION OVEN| NA| 575| 48| 6 (FRONT EDGE OF DOOR)| 8| NA| 0
STEAMER / COMBI OVEN| NA| 575| 48| 6 (TOP EDGE OF DOOR)| 20| NA| 0
STEAM JACKETED KETTLE| 16.9| 450| 48| 14 (EDGE OF HEATED SURFACE)| 30| 42| 0
SANDWICH GRILL (1)| 4.5| 550| 36| 18 (EDGE OF HEATED PLATEN)| 30| 42| 0
CONVEYOR OVEN| 4.5| NA| 23| 6 (EDGE OF HEATED SURFACE)| 20| 42| 0
- LID OF THE APPLIANCE MUST NOT INTERFERE WITH SUPPPRESSION NOZZLE DISCHARGE PATTERN.
- PLUSOVEN KW IF APPLICABLE
THE HOOD AND ALL UNDER HOOD APPLIANCES MUST BE INSTALLED IN ACCORDANCE WITH
THE STANDARD FOR VENTILATION CONTROL AND FIRE PROTECTION OF COMMERCIAL COOKING
OPERATIONS NFPA 96, THE NATIONAL ELECTRIC CODE NFPA 70 AND ALL LOCAL CODES
WHERE APPLICABLE. ALL UNDER HOOD APPLIANCES MUST BE INSTALLED AS PER
MANUFACTURER INSTRUCTIONS AND CONTROLLED BY THE HOOD EQUIPMENT SHUTOFF
INTERFACE THROUGH A CUSTOMER SUPPLIED CONTACTOR. SEE THE INSTRUCTION MANUAL
FOR INTERFACE CONNECTION OPTIONS. APPUANCES MUST MEET EQUIPMENT PARAMETERS
DESCRIBED ABOVE. ONLY ELECTRICALLY HEATED APPLIANCES ARE ACCEPTABLE FOR
INSTALLATION. PRIOR TO OPERATION THE FIRE SUPPRESSION SYSTEM MUST BE CHARGED
AND CERTIFIED BY AN ANSUL® AUTHORIZED DISTRBUTOR. ADEQUATE SIDE CLEARANCE MUST
BE PROVIDED FOR SUPPLY CONNECTION AND SUPPRESSION MANUAL PULL ACCESS.
EXHAUST IS SHIPPED FOR HORIZONTAL DISCHARGE AND FIELD CONVERTIBLE FOR VERTICAL
DISCHARGE.
WELLS MANUFACTURING 265
HOBSON ST. SMITHVILLE, TN
37166 USA
NOTE: SPACFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE.