auronic AU3165 Dehumidifier With Air Purification User Manual

June 16, 2024
auronic

**auronic AU3165 Dehumidifier With Air Purification User Manual

**

INTRODUCTION

Thank you for choosing our Aaronic product! Please always follow the instructions for safe usage.

Intended use
This product is a device that can be used to reduce moisture in the air. It is mainly recommended to be used in various situations where there is excess moisture in the environment. You can use this product to regulate room humidity, address moisture problems, prevent mold, improve air quality and extend the life of possessions. It can be used in a variety of environments and situations. This product is only intended to reduce humidity in living spaces, basements or storage areas with an ambient temperature of 5 to 35°C. The product is to be used indoors only. The product is intended for personal and not commercial use only.

The supplier is released from liability for any injury or damage caused by using the product beyond its intended use. Any modification of the product may affect your safety and warranty.

Product overview

  1. Control panel

  2. Handle

  3. Air grille

  4. Drain pipe

  5. Wheels

  6. Exhaust air flap

  7. Rear casing

  8. Power cable

  9. Exhaust air flap

  10. Front housing

  11. Water tank

  12. On/Off

  13. Timer

  14. Manual dehumidification

  15. Fan speed/Child lock

  16. Wax drying function

  17. Ionization

  18. Ionization indicator

  19. Wash dry indicator

  20. High speed indicator

  21. Low speed indicator

  22. Screen

  23. Timer indicator

  24. Tank full indicator

  25. Defrost indicator

  26. On/Off indicator

  27. Drain tube
    Product overview

Product specifications

AU3165 AU570 AU3219 AU3220
Dimension 33.5 x 28.5 x 54 cm 33,5 x 28,5 x 54 cm 33,5 x 28,5 x 54 cm
Weight 15.2 kg 14.2 kg 15.2 kg
Material ABS, copper and PCB ABS, copper and PCB ABS, copper and PCB
Color White White White
Cord length 1.8 m 1.8 m 1.8 m
Drain hose Length: 60 diameter: 14 mm Length: 60 diameter: 14 mm Length: 60

diameter: 14 mm
IP rating| IP20| IP20| IP20
Voltage| 220 – 240V~| 220 – 240V~| 220 – 240V~
Frequency| 50Hz| 50Hz| 50Hz
Power| 255W (27°C 60%)355W (35°C 80%)| 215W (27°C 60%)275W (35°C 80%)| 325W (27°C 60%)480W (35°C 80%)
Water tank capacity| 5 l| 5 l| 5 l
Current| 1.55A (27°C 60%)1.85A (35°C 80%)| 1.30A (27°C 60%)1.55A (35°C 80%)| 1.80A (27°C 60%)2.40A (35°C 80%)
Safety class plug| 1| 1| 1
Coolant| R290/0.075 kg| R290/0.055 kg| R290/0.08 kg
Max. dehumidification| 20 l / 24 h (30°C 80%)11.5 l / 24 h (27°C 60%)| 16 l / 24 h (30°C 80%)9.5 l / 24 h (27°C 60%)| 25 l / 24 h (30°C 80%)15 l / 24 h (27 ° C 60%)
Suction side pressure| 1.0 MPa| 1.0 MPa| 1.0 MPa
Pressure exhaust side| -2.5 MPa| -2.5 MPa| -2.5 MPa
Operating temperature| 5 to 35°C| 5 to 35°C| 5 to 35°C
Storage temperature| 5 to 35°C| 5 to 35°C| 5 to 35°C
Operating humidity| 30 to 80%| 30 to 80%| 30 to 80%
Storage humidity| 45 to 65%| 45 to 65%| 45 to 65%
Noise level| 42 – 44dB| 42 – 44dB| 44 – 46dB
Min. surface area to be dehumidified| 20 m2| 20 m2| 20 m2
Max. surface area to be dehumidified| 40 m2| 32 m2| 50 m2
Min. air flow rate| 130 m³/h| 120 m³/h| 155 m³/h
Max. airflow| 145 m³/h| 140 m³/h| 170 m³/h
Timer| 0 – 24 h| 0 – 24 h| 0 – 24 h
CO2 equivalent| 150| 150| 150
GWP factor| 3| 3| 3

Contents of package
When receiving your shipment, make sure that the contents are consistent with the packing
list. Notify your distributor of any missing items. If the equipment appears to be damaged,
file a claim immediately with the carrier and notify your distributor at once, giving a detailed
description of any damage. Save the damaged parts and packing container to substantiate
your claim

Aaronic Dehumidifier with air purification – 20 l – Model AU3165 – EAN 8720195254232
Aaronic Dehumidifier with air purification – 16 l – Model AU3219 – EAN 8720195258445
Aaronic Dehumidifier with air purification – 25 l – Model AU3220 – EAN 8720195258452
Aaronic Dehumidifier with air purification – 20 l – Model AU570 – EAN 8720195259114

Included accessories

  • 1x User manual
  • 4x Wheels
  • 1x Drain hose

 SAFETY

  Please ensure that the packaging is kept out of the reach of children! Risk of suffocation! **** Before use, read the manual and safety information carefully. The supplier is not responsible for
failure to follow the safety information on the use and handling of the product or damage to property or personal injury

Always observe the following precautions when using ‘the Dehumidifier with air purification’,
hereinafter referred to as ‘the product’.

General

  • Be aware of the risks and consequences associated with misuse of the product. Misuse may
    result in personal injury and damage to the product.

  • Leave at least 50 cm of ventilation space around the product.

  • The product is designed only for combination with R-290 (propane) gas as refrigerant.
    Observe national gas regulations.

  • Do not release the refrigerant into the atmosphere.

  • R-290 (propane) is flammable and heavier than air. It first collects in low areas and is
    circulated by fans.

  • Propane gas is odorless. The lack of odor does not indicate that the gas has not escaped. If
    a leak is detected, immediately evacuate all persons from the area, ventilate the area and contact the local fire department to indicate that there is a propane leak

  • Water collected is not suitable for drinking or watering plants. This may be a potential health hazard.

  • The product operates only in areas with an ambient temperature between 5˚C and 35˚C. If
    the ambient temperature is below 5˚C and above 35˚C, the product will not work.

  • Use the product only for the purposes indicated in this manual.

  • If the product is malfunctioning, dropped or damaged, do not use it and consult Customer
    Service.

  • The product is designed and intended for private use. Do not use it for commercial
    purposes.

  • Do not unplug the product while it is on. Unplug the product when not in use.

  • Do not tilt the product. If the product is (has been) tilted more than 45°, leave it upright for at least 24 before turning it on.

  • Empty the water tank before moving the product.

Persons

  • This product may be used by children 8 years of age and older if they are properlyupervised and instructed in the safe use of the product and understand its potential hazards. Cleaning and maintenance of the product should not be performed by children.
  • The product can be used by people with physical or mental disabilities, provided that they are properly supervised and informed concerning the safe use of the product and understand its possible dangers.
  • The product is not a toy. Keep children under 3 years of age closely supervised and away from the product. Do not allow children to play with the product.

Use

  • Do not put or place objects on the product or sit on it.

  • Do not insert fingers or objects into the ventilation holes.

  • Do not touch the ventilation holes.

  • Always place the product on a flat, stable and level surface.

  • Do not use the product near a bathtub, a shower, a (laundry) tub filled with water or similar places.

  • Do not immerse the product, cabling or plug in water or other liquids.

  • Protect the product from dripping or spraying.

  • If water enters the product (except for the water tank), unplug it immediately. Have the
    product checked for damage before using it again.

  • Do not touch the product with wet hands.

  • If the product falls into water, unplug it immediately. Do not remove the product from water until the plug is unplugged.

  • Do not use the product in a potentially explosive environment where there are flammable
    liquids, gases or substances. Electrical appliances may generate sparks that may ignite dust
    or vapors.

  • The product contains extremely highly flammable pressurized gas. This gas may explode
    when heated.

  • Keep the product away from heat, hot surfaces, open flames and other sources of ignition.
    Do not smoke near the product.

  • Do not use items other than those approved by the manufacturer to aid the defrosting
    process.

  • The product should be stored only in areas without permanent ignition sources (e.g., open
    flames, appliances that run on gas and are on, electric heaters).

  • Do not drill into the product. Do not burn the product.

  • Remember that refrigerants are odorless.

  • Do not use the product near swimming pools, bathrooms or similar environments.

  • The product is not suitable for drying insulation materials. If insulation materials are damp due to a cracked pipe, consult an expert.

  • Never expose the product to temperatures equal to or below 0°C. Residual water in the
    pipes may freeze and damage the product.

  • Do not use the product in a dusty environment or in an area treated with chlorine.

  • Unplug the product before cleaning or servicing it.

Electronics

  • Do not disassemble, repair or restore the product. Doing so may cause damage to the
    product. For your own safety, these parts should only be replaced by authorized service
    personnel. Before connecting the product, ensure that the mains voltage indicated on the
    rating plate matches that of your mains supply.

  • Check both power cord and plug regularly for signs of damage or wear, and if there is
    any, do not use the product and have the power cord and/or plug replaced or repaired by
    authorized service personnel.

  • There is a risk of electrocution if live cables are touched and electrical and mechanical
    structures are modified.

  • If the power fails during use, immediately turn off the product and unplug the power cord.

  • Do not pull on the cord to unplug it.

  • Do not move the product by pulling the cord or twist the cord.

  • Be careful not to trip over the cable and make sure the cable is not kinked, twisted, or stuck.

  • Do not place the cable on hot surfaces or near oil. Do not leave the cable hanging over the
    edge of a table or countertop.

  • The product should only be connected to a grounded 220-240V~ outlet.

INSTRUCTIONS FOR USE

Installation

  • Place the product upright on a stable, flat surface.
  • Make sure the product is at a safe distance of at least 50 cm from a wall or furniture.
  • The supply voltage must match the value on the rating plate and the outlet must be grounded.
  • Check that the water tank is correctly positioned. If the water tank is full or not in place, the “water tank full” light comes on and the product stops working

How to use

  1. Make sure the water tank is empty and properly placed.

  2. Connect the product to the power outlet.

  3. Press the power button (12) to turn the product on. The product will default to manual
    continuous dehumidification with high fan speed. The on/off indicator will light up.

  4. Select the desired mode.

  5. Press the on/off button (12) to turn the product off. The fan will still work for a few seconds to blow out the warm air inside the produc

Automatic switch-off timer

  1. Press the timer button (13) to select the desired number of timer hours from 00 to 24 hours for automatic shutdown.
  2. The automatic shutdown can be canceled if the timer button (13) is pressed twice within three seconds.
  3. The automatic shutdown can also be canceled if you turn the product off and on again.

Manual dehumidification mode
Press the manual dehumidify key (14) to select the desired humidity level between CO-30%- 35%-40%-45%-50%-55%-60%-65%-70%-75%- 80%. CO means continuous dehumidification regardless of the ambient humidity

Fan speed
Press the fan speed button (15) to select the desired fan speed between low and high. The fan speed button does not work in defrost mode.

Child lock
Press the child lock button (15) for 2 seconds to lock all buttons with a beeping sound

The child lock function can be set in standby mode and working mode, but cannot be activated when the water tank is full.

Laundry drying function
Press the wash dry button (16) to select the wash dry function. The product operates in continuous dehumidification with high fan speed for 6 hours and then turns off automatically

Memory function
When the power cord is unplugged directly or the power is disconnected, and then reconnected to the power supply, the product will continue to operate in the mode as it was before it was turned off. The timer setting will be retained.

  1. Press the power button (12) to turn off the product, then press the power button to start.
  2. Turn the product off and unplug it, then plug it back in and turn the product on. The product will operate in the factory setting as it was set the first time.

Low temperature defrost indicator
When the ambient temperature is too low, the product will go into defrost mode, the product will operate at high fan speed without dehumidifying

Automatic shutdown with water  tank full indicator
The product will switch to standby mode when the water tank is full or when the water tank is not installed correctly. After emptying the water tank, or installing the water tank correctly, the product will switch to the previous mode

Air cleaning/Ionization function
Press the ionization button to activate the ionization function to improve air quality

This function activates air cleaning and absorption of airborne particulate matter/ particles by ionization. Ionizers produce a stream of charged particles (ion flow) in the air that precipitate (fine) dust particles in the environment. In theory, this has a beneficial effect on air quality (source: RIVM).
Air cleaning/Ionization function

The benefits of ionization for cleaner air:

  • Removes pollutants : Ionization is an effective method of neutralizing and removing airborne pollutants. Negative ions attach themselves to particles such as dust, pollen, mold spores and bacteria, making them heavier and sink to the ground. This results in cleaner air and  reduces the risk of respiratory problems and allergies.
  • Actively fights bacteria and viruses : Ionization can help fight airborne bacteria and viruses. Negative ions can bind to pathogens and inactivate them, making them no longer harmful to health. This is especially important in areas where people congregate, such as stores, offices, schools and medical facilities.
  • Reduces odors : Negative ions also have the ability to neutralize odors. They attach to odor molecules and break them down, eliminating unpleasant odors. Whether it is cooking odors in the kitchen, smoke odor in a smoking room or other bothersome odors, ionization can  help create a fresh and pleasant environment.
  • Improves air quality : By removing contaminants and reducing airborne allergens, ionization contributes to an overall improvement in air quality. This can lead to a healthier indoor environment, with fewer respiratory irritations and an increased sense of comfort

Drain hose
In general, the water is collected in the water tank. If you want continuous water drainage, follow these steps.

  1. Unplug the product.
  2. Insert the drain hose with an inside diameter of 14 mm into the water outlet. Always make sure the pipe runs down and is not blocked or kinked.
  3. Make sure the hose is in a container or something similar to catch the water.

Emptying the water tank
Note: When the water tank is full, the warning light on the bottom of the product will flash red.
The product beeps briefly 5 times and automatically turns off. The warning light will continue to
flash until the water tank is replaced.

  1. Hold the water tank with two hands. Push against the product with your thumbs and gently
    pull out the reservoir (Fig. 1).

  2. Remove the cover from the reservoir and empty the reservoir (Fig. 2).

  3. Replace the reservoir and press the power button (12) to turn the product back on.
    Emptying the water tank

Audible signal
When the water tank is full of water, the product will stop working and emit a sound signal.
The audible signal will be audible for 20 seconds after you remove the collection tray from the
product.

TROUBLESHOOTING

Problem Cause Solution
The product no longer works. The cable is not plugged in. Plug in the power

cord.
The water tank is full.| Empty the water tank.
The water tank is incorrectly positioned.| Reinstall the water tank.
Water removal capacity is too low.| Run time is too short.| Be patient, and wait a while longer.
Ambient temperature or humidity is too low.| It is common for the product not to work in these conditions.
Product works but does not reduce relative humidity sufficiently.| Ambient space is too large.| It is recommended that you look for a dehumidifier with a longer range.
There is too much ventilation at that time.| Make sure you ventilate the room less.
The air filter is clogged.| Clean the air filter.
The entered humidity level is higher than the ambient temperature.| Set the entered humidity level lower than the ambient temperature.
Warm air is coming out of the product.| The dried air is passed over heating coils before being blown into the room as part of the dehumidification process.| This is completely normal, nothing is wrong.
Display does not show humidity set point.| The display shows the ambient humidity, not the humidity set at the set point.| Press the humidity knob to reset the desired humidity level.
Water on the floor.| There is residual water in the water tank.| Be careful when moving the water tank.
The product makes a lot of noise.| The air filter is blocked, or the product is not on a level surface.| Clean the air filter or place the product on a flat surface.

Contact the supplier if you encounter one or more of the error message(s) below.

Error code Error message Display Cause
E1 Temperature sensor error message. Flashes on screen every 30 seconds.

Product is still dehumidifying air while in defrost mode.
E2| Humidity sensor error message.| Flashes every 30 seconds in picture.| Product is still dehumidifying while in continuous dehumidification mode.
L4| The product is in a room that is too cold.| Flashes every 30 seconds in picture.| Make sure the room is at least 2˚C warmer. After±10 minutes, the product starts working again.

MAINTENANCE AND CLEANING

  1. Turn the product off and unplug the power cord.

  2. Clean the casing with a soft, dry cloth. If the product is very dirty, use a mild detergent.

  3. Wipe the product with a slightly damp cloth. Never spray the product with water. Do not use aggressive or chemical cleaning agents. Do not immerse the product in water or hold the
    product or parts of the product under running water.

  4. Remove the filter and clean the filter with a vacuum cleaner or soapy water no hotter than 40°C.

  5. Rinse and dry the filter completely before replacing it in the produce

STORAGE

Store the product in a clean and dry place. Do not store the product in extreme high or extreme
low temperatures.

DISPOSAL AND RECYCLE

Think about the environment and contribute to a cleaner living environment! This product is
subject to the European Directive (EU) 2012/19/EU. At the end of its service life, do not dispose of the product with normal household waste, but deliver it to a collection point designated by the authorities for recycling

SYMBOLS

Symbol Description
Please read and save the manual!
Recycle this product
CE mark: in accordance with European regulations
Restriction of (the use of certain) hazardous substances in electrical and

electronic equipment
| WEEE symbol: do not dispose of as unsorted waste, collect separately for recycling
| Safety class 1 plug.
| Suitable for indoor use.
| Protected against solid objects above 12 mm.
| This manual can be recycled.
| This device and its accessories can be recycled.
| Polyethylene terephthalate (PET)/Polyester
| High-density polyethylene
| Polypropylene.
| Acrylonitrile butadiene styrene.
| Steel
| Aluminum
| Paper with corrugated cardboard (fiberboard)
| Paper with corrugated cardboard (fiberboard).
| Handle with care.
| Protect from moisture.
| Do not cut.
| Careful, fragile.
| This side up.

DISCLAIMER

Changes reserved; specifications are subject to change without stating grounds for doing so.
auronic Logo

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals