MEAN WELL LRS-100 100W Single Output Switching Power Supply User Manual

June 4, 2024
MEAN WELL

MEAN WELL LRS-100 100W Single Output Switching Power Supply User Manual
MEAN WELL LRS-100 100W Single Output Switching Power
Supply

Features

  • Universal AC input / Full range
  • Withstand 300VAC surge input for 5 second
  • Protections: Short circuit / Overload / Over voltage
  • Cooling by free air convection
  • Miniature size and 1U low profile
  • Compliance to IEC/BS EN/EN 60335-1(PD3) and IEC/BS EN/EN61558-1, 2-16 for household appliances
  • Operating altitude up to 5000 meters (Note.7)
  • Withstand 5G vibration test
  • LED indicator for power on
  • No load power consumption<0.3W
  • Over voltage category Ⅲ
  • 100% full load burn-in test
  • High operating temperature up to 70℃
  • High efficiency, long life and high reliability
  • 3 years warranty

Applications

  • Industrial automation machinery
  • Industrial control system
  • Mechanical and electrical equipment
  • Electronic instruments, equipments or apparatus
  • Household appliances

Description

LRS-100 series is a 100W single-output enclosed type power supply with 30mm of low profile design. Adopting the full range 85~264VAC input, the entire series provides an output voltage line of 3.3V, 5V, 12V, 15V, 24V, 36V and 48V.

In addition to the high efficiency up to 91%, the design of metallic mesh case enhances the heat dissipation of LRS-100 that the whole series operates from -30℃ through 70℃ under air convection without a fan.

Delivering an extremely low no load power consumption (less than 0.3W), it allows the end system to easily meet the worldwide energy requirement. LRS-100 has the complete protection functions and 5G antivibration capability; it is complied with the international safety regulations such as TUV BS EN/EN2368-1, BS EN/EN60335- 1,BS EN/EN61558- 1/- 2-16, UL62368- 1 and GB4943. LRS- 100 series serves as a high price- to- performance power supply solution for various industrial applications.

Model Encoding

Model Encoding

SPECIFICATION

MODEL| LRS-100-3.3| LRS-100-5| LRS-100-12| LRS-100-15| LRS-100-24| LRS-100-36| LRS-100-48
---|---|---|---|---|---|---|---
OUTPUT| DC VOLTAGE| 3.3V| 5V| 12V| 15V| 24V| 36V| 48V
RATED CURRENT| 20A| 18A| 8.5A| 7A| 4.5A| 2.8A| 2.3A
CURRENT RANGE| 0 ~ 20A| 0 ~ 18A| 0 ~ 8.5A| 0 ~ 7A| 0 ~ 4.5A| 0 ~ 2.8A| 0 ~ 2.3A
RATED POWER| 66W| 90W| 102W| 105W| 108W| 100.8W| 110.4W
RIPPLE & NOISE (max.) Note.2| 100mVp-p| 100mVp-p| 120mVp-p| 120mVp-p| 150mVp-p| 200mVp-p| 200mVp-p
VOLTAGE ADJ. RANGE| 2.97 ~ 3.6V| 4.5 ~ 5.5V| 10.2 ~ 13.8V| 13.5 ~ 18V| 21.6 ~ 28.8V| 32.4 ~ 39.6V| 43.2 ~ 52.8V
VOLTAGE TOLERANCE Note.3| ±3.0%| ±2.0%| ±1.0%| ±1.0%| ±1.0%| ±1.0%| ±1.0%
LINE REGULATION Note.4| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%
LOAD REGULATION Note.5| ±2.0%| ±1.0%| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%
SETUP, RISE TIME| 500ms, 30ms/230VAC               500ms,30ms/115VAC at full load
HOLD UP TIME (Typ.)| 55ms/230VAC      10ms/115VAC at full load
INPUT| VOLTAGE RANGE| 85 ~ 264VAC             120 ~ 373VDC (Withstand 300VAC surge for 5sec. Without damage)
FREQUENCY RANGE| 47 ~ 63Hz
EFFICIENCY (Typ.)| 84.5%| 86%| 88%| 88.5%| 90%| 90.5%| 91%
AC CURRENT (Typ.)| 1.9A/115VAC         1.2A/230VAC
INRUSH CURRENT (Typ.)| COLD START 50A/230VAC
LEAKAGE CURRENT| <0.75mA / 240VAC
PROTECTION| OVER LOAD| 110 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
OVER VOLTAGE| 3.8 ~ 4.45V| 5.75 ~ 6.75V| 13.8 ~ 16.2V| 18.75 ~ 21.75V| 28.8 ~ 33.6V| 41.4 ~ 48.6V| 55.2 ~ 64.8V
Protection type : Shut down o/p voltage, re-power on to recover
ENVIRONMENT| WORKING TEMP.| -30 ~ +70℃ (Refer to “Derating Curve”)
WORKING HUMIDITY| 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 ~ +85℃, 10 ~ 95% RH non-condensing
TEMP. COEFFICIENT| ±0.03%/℃ (0 ~ 50℃)
VIBRATION| 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes
OVER VOLTAGE CATEGORY| Ⅲ; Compliance to BS EN/EN61558, BS EN/EN50178, BS EN/EN60664-1, BS EN/EN62477-1; altitude up to 2000 meters
SAFETY & **EMC (Note 8)| SAFETY STANDARDS**| UL 62368-1, TUV BS EN/EN62368-1, BS EN/EN60335-1, BS EN/EN61558-1/-2-16,CCC GB4943.1,BSMI CNS14336-1, EAC TP TC 004,S/NZS62368.1(by CB),KC K60950-1(for LRS-100-12/24 only), BIS IS13252(Part1):

2010/IEC 60950-1: 2005 approved

WITHSTAND VOLTAGE| I/P-O/P:4KVAC I/P-FG:2KVAC  O/P-FG:1.25KVAC
ISOLATION RESISTANCE| I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION| Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN55014, BS EN/EN61000-3-2,-3, GB/T 9254, BSMI CNS13438, EAC TP TC 020,KC KN32,KN35(for LRS-100-12/24 only)
EMC IMMUNITY| Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN61000-6-2 (BS EN/EN50082-2), heavy industry level, criteria A, EAC TP TC 020,KC KN32,KN35(for LRS-100-12/24 only)
OTHERS| MTBF| 720.6K hrs min.         MIL-HDBK-217F (25℃)
DIMENSION| 1299730mm (LWH)
PACKING| 0.34Kg ; 40pcs/14.6Kg/0.92CUFT
NOTE|

  1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
  2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
  3. Tolerance : includes set up tolerance, line regulation and load regulation.
  4. Line regulation is measured from low line to high line at rated load.
  5. Load regulation is measured from 0% to 100% rated load.
  6. Length of set up time is measured at cold first start. Turning ON/OFF the power supply very quickly may lead to increase of the set up time.
  7. The ambient temperature derating of 5℃/1000m is needed for operating altitude greater than 2000m(6500ft).
  8. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to [EMI testing of component power supplies.] (as available on http://www.meanwell.com)

※ Product Liability Disclaimer: For detailed information, please refer to https://[www.meanwell.com/serviceDisclaimer.aspx](http://www.meanwell.com/serviceDisclaimer.aspx)

Block Diagram

Block Diagram

Derating Curve

Derating Curve

Static Characteristics

Static Characteristicso

Mechanical Specification

Mechanical Specification Mechanical
Specification

Terminal Pin No. Assignment

Terminal

| Pin No.| Assignment|
---|---|---|---
Pin No.| Assignment| Pin No.| Assignment
1| AC/L| 4,5| DC OUTPUT -V
2| AC/N| 6,7| DC OUTPUT +V
3| FG | |

Installation Manual

Please refer to : http://www.meanwell.com/manual.html

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

MEAN WELL User Manuals