FIXTURE DIAGRAM

CAUTIONS

CAUTION – RISK OF SHOCK:
Disconnect Power at the main circuit breaker panel or main fuse box before starting and during the installation.

WARNING:
This fixture is intended for installation in accordance with the National Electrical Code (NEC) and all local code specifications. If you are not familiar with code requirements, installation by a certified electrician is recommended. Failure to adhere to these codes and instructions may result in serious injury and/or property damage and will void the warranty.

CAUTION :
To reduce the risk of fire, do not install closer than 1 inch to cabinet wall or in compartment smaller than 12 inches by 12 inches by 12 inches.

CLEANING:

  • Always be certain that electric current is turned off before cleaning.
  • Only a soft damp cloth should be used. Harsh cleaning products may damage the finish.

IMPORTANT SAFETY INSTRUCTIONS

a ) Read all instructions.
b ) Do not conceal or extend exposed conductors through a building wall, floor or ceiling.
c ) Install this system in dry or damp locations only.
d ) To reduce risk of fire and burns, do not install this lighting system where the exposed bare conductors can be shorted or contact any conductive materials.
e ) To reduce the risk of fire and overheating, make sure all connections are tight.
f ) Do not install any luminaire closer than 6 inches (15.25cm) from any curtain, or similar combustible materials.
g ) Power supply has two distinct sections:

  • line voltage (AC Input), black and white
  • low voltage (DC Output), red and black
    It is important to keep the line voltage and the DC voltage wires separate.

SAVE THESE INSTRUCTIONS

NOTE: Kichler 4TD-Series and 6TD-Series are compatible with wide variety of dimmers in the market, including but not limited to:

MANUFACTURER: MODEL NUMBER:
Lutron AYCL-153P
Lutron SCL-153P
Lutron CTCL-153P
Lutron DVCL-153P
Lutron MACL-153M
Legrand ADPD453LW2
Legrand ADTP703TUM4

INSTALLATION INSTRUCTIONS

  1. Turn off power.

  2. Determine desired location for mounting power supply. Power supply should be located within 25’ of first luminaire.

  3. Secure power supply using provided mounting screws. Secure into wall studs if possible, otherwise, use appropriate anchors rated for proper wall material and hanging weight (not included).

  4. Using the pre-punched knock-outs in the metal enclosure, route the 120V line voltage to the primary side (AC Input) of the power supply.
    NOTE: A proper UL listed cable connector must be used in the knock-out to provide strain relief and wire protection (cable connector provided). In addition, all unused knockouts shall be covered.

  5. Make grounding connection (connector provided).

  6. Make wire connections (connectors are provided). Reference chart below for connections and wire accordingly.
    Connect Line (Black Supply Wire) to:| Connect Neutral (White Supply Wire) to:
    ---|---
    Black| White
    Parallel cord (round & smooth)| Parallel cord (square & ridged)
    Clear without tracer| Clear with white tracer
    *Note: When parallel wire (SPT 1 & SPT 2) are used. The neutral wire is square shaped or ridged and the other wire will be round in shape or smooth (See illus.)|

  7. The total load connected to the power supply should not exceed the rated Wattage of the power supply. In the event that the connected LED’s (load) exhibit an overload condition consisting of blinking LEDs and or a restart of the system, it is suggested that the load should be set to not exceed 80 to 85% of the rated wattage.
    NOTE: After determining the layout of the system, add the wattage of each luminaire/fixture together to calculate the total system consumption. The calculated total system consumption should be equal or less than the Class 2 power supply rating that is being used.

  8. Using the pre-punched knock-outs in the metal enclosure, route and connect the lighting system leads to the secondary side low voltage (DC output) of the power supply.
    NOTE: Connect positive to the red wire and negative to the black wire using the supplied wire nuts or other UL approved connectors. Do not exceed manufacturers’ wiring combination specifications for size and quantity of conductors.
    NOTE: A proper UL listed cable connector must be used in the knockouts to provide wire protection (cable connector provided).
    NOTE: Ensure cover is closed and secured before applying power.

FCC INFORMATION

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:

  1. This device may not cause harmful interference, and

  2. This device must accept any interference received, including interference that may cause undesired operation.
    Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

    • Reorient or relocate the receiving antenna.
    • Increase the separation between the equipment and receiver.
    • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
    • Consult the dealer or an experienced radio/TV technician for help.

CUSTOMER SUPPORT

For warranty information please visit: kichler.com/warranty
Para informacion de la granita por favor visite: kichler.com/warranty
Kichler® Power Supplies
4TD12V060BKTv2, 6TD24V060BKTv2, 6TD24V096BKTv2
Installation Instructions
We’re here to help 866-558-5706
Hrs: M-F 9am to 5pm EST

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

KICHLER User Manuals

Related Manuals