Specifications

  • Mounting Plate [A]
  • Outlet Box (not supplied) [B]
  • Plate Mounting Screw (2) [C]
  • Canopy [D]
  • Mounting Screw (2) [E]
  • Glass Retainer (2) [F]
  • Glass Retainer Screw (2 per Glass Shade) [L]
  • Glass Shade (2) [H]
  • Glass Mounting Channel (2) [I]

Installation Instructions

Step 1: Attach the Mounting Plate to the Outlet Box

  1. Attach the mounting plate [A] to the outlet box [B] using the plate mounting screws [C]. The mounting plate can be adjusted to follow the position of the fixture.
  2. Make sure to install the mounting plate with the flat side against the wall.
  3. The bent flanges at the outer edge of the mounting plate should point away from the wall, at the 12 and 6 o’clock positions.

Step 2: Grounding Instructions
Follow either option a or b depending on the provided fixtures:

Option a: Fixtures with Mounting Plate Holes and Dimples

  1. Wrap the ground wire from the outlet box around the green ground screw and thread it into the hole on the mounting plate.

Option b: Fixtures with Cupped Washer

  1. Attach the ground wire from the outlet box under the cupped washer and the green ground screw. Thread it into the mounting plate.

If the fixture is provided with a ground wire, connect the fixture ground wire to the outlet box ground wire using a wire connector after following the above steps. Never connect the ground wire to black or white power supply wires.

Step 3: Make Wire Connections
Refer to the chart below for the correct connections:

Connect Black or Red Supply Wire to: Connect White Supply Wire to:
Parallel cord (round & smooth) Parallel cord (square & ridged)
Clear, Brown, Gold or Black without Tracer Clear, Brown, Gold or Black with

Tracer
Insulated wire (other than green) with copper conductor| Insulated wire (other than green) with silver conductor

Note: When using parallel wire (SPT 1 & SPT 2), the neutral wire is square-shaped or ridged, and the other wire will be round in shape or smooth.

Step 4: Mount Fixture with Glass Shades

  1. The fixture can be mounted with glass shades [H] in the up or down position.
  2. Push the canopy [D] to the wall, aligning the mounting screw holes in the mounting plate with the mounting screw holes in the canopy.
  3. Make sure all wires are inside the canopy and do not get pinched between the mounting plate and canopy or wall and canopy of the fixture.

Step 5: Attach Fixture to Wall

  1. Screw two mounting screws [E] into the holes in the canopy and mounting plate to attach the fixture to the wall. Tighten them to secure the fixture.
  2. Install one screw at the top and one at the bottom of the canopy.

Step 6: Install Glass Shades

  1. Remove two glass retainer screws [G] and glass retainer [F] from the glass mounting channel [I]. Repeat this step if required for other sockets.
  2. Insert the recommended bulb(s) (not included).
  3. Carefully slide the glass shade [H] into the slot of the glass mounting channel until seated.
  4. While holding the glass shade in place, reinstall the glass retainer and glass retainer screws to the glass mounting channel. Tighten the glass retainer screws to secure the glass shade. Repeat this step if required for other glass shades.

FAQ

  • Q: Can I install the fixture with glass shades in different positions?
    A: Yes, you can mount the fixture with the glass shades in either an up or down position.

  • Q: How should I make wire connections?
    A: Refer to the provided chart for correct wire connections based on the type of supply wire you have.

  • Q: Can I adjust the position of the mounting plate?
    A: Yes, the mounting plate can be adjusted to follow the desired position of the fixture.

  • Q: What should I do if the fixture is provided with a ground wire?
    A: Connect the fixture ground wire to the outlet box ground wire using a wire connector. Never connect the ground wire to black or white power supply wires.

  • Q: What type of bulbs should I use?
    A: The recommended bulbs are not included with the fixture. Please refer to the product specifications for the appropriate bulb type.

FIXTURE DIAGRAM

PARTS LIST

  • [A] Mounting Plate
  • [B] Outlet Box (not supplied)
  • [C] Plate Mounting Screw (2)
  • [D] Canopy
  • [E] Mounting Screw (2)
  • [F] Glass Retainer (2)
  • [G] Glass Retainer Screw (2 per Glass Shade)
  • [H] Glass Shade (2)
  • [I] Glass Mounting Channel (2)

SAFETY CAUTIONS

CAUTION – RISK OF SHOCK:
Disconnect Power at the main circuit breaker panel or main fusebox before starting and during the installation.

  • WARNING:
    • This fixture is intended for installation by the National Electrical Code (NEC) and all local code specifications. If you are not familiar with code requirements, installation by a certified electrician is recommended. Failure to adhere to these codes and instructions may result in serious injury and/or property damage and will void the warranty.
  • CLEANING:
    • Always be certain that electric current is turned off before cleaning.
    • Only a soft damp cloth should be used. Harsh cleaning products may damage the finish.

INSTALLATION INSTRUCTIONS

  1. Attach mounting plate [A] to outlet box [B] using the plate mounting screws [C]. Mounting plate can be adjusted to suit position of fixture.
    NOTE: Mounting plate should be installed with the flat side of the mounting plate against the wall.
    NOTE: Mounting plate should be installed with the bent flanges at the outer edge of the mounting plate pointing away from the wall, at the 12 and 6 o’clock position.

  2. Grounding instructions: (See Illus. a or b).

    • a. On fixtures where mounting plate is provided with a hole and two raised dimples, wrap ground wire from outlet box around green ground screw, and thread into hole.
    • b. On fixtures where a cupped washer is provided, attach ground wire from outlet box under cupped washer and green ground screw, and thread into mounting plate.
      If fixture is provided with ground wire, connect fixture ground wire to outlet box ground wire with wire connector after following the above steps. Never connect ground wire to black or white power supply wires.
  3. Make wire connections. Reference chart below for correct connections and wire accordingly.

  4. NOTE: Fixture can be mounted with glass shades[H] in the up or down position.
    Push canopy[D] to wall, carefully aligning the mounting screw holes in mounting plate with the mounting screw holes in canopy.
    NOTE: Make sure all wires are inside canopy and do not get pinched between mounting plate and canopy or wall and canopy of fixture.

  5. Screw two (2) mounting screws[E] into holes in canopy and mounting plate to attach fixture to wall. Tighten to secure.
    NOTE: Install one (1) at the top and one (1) at the bottom of canopy.

  6. Remove two (2) glass retainer screws[G] and glass retainer[F] from the glass mounting channel[I]. (Repeat if required for other sockets).

  7. Insert recommended bulb(s) (not included).

  8. Carefully slide glass shade[H] into the slot of the glass mounting channel until seated. While holding glass shade in place, reinstall glass retainer and glass retainer screws to the glass mounting channel. Tighten glass retainer screws to secure glass shade.(Repeat if required for other glass shades).