Ruichuangte BC02 Smart Badge User Guide
- June 3, 2024
- Ruichuangte
Table of Contents
BC02 Badge User Guide
08/17/2022
BC02 Smart Badge
(Please read the instruction carefully before installation and use)
Nanjing Ruichuangte Information Technology Co., LTD
Warning
- Do not disassemble, replace or charge the battery in dangerous places.
- Do not rub the surface of the shell with other objects to prevent static electricity.
- Do not open the shell in a dangerous place to repair the equipment.
- The model, specification, and other parameters of intrinsically safe products and electronic components related to intrinsically safe circuits shall not be changed at will during maintenance.
- Do not connect with the equipment outside the specification. When connected with other equipment, it must pass explosion-proof inspection.
- Before using the product, release static electricity and wipe it with a damp cloth.
FCC Warning
This device complies with part 15 of the FCC Rules. Operation is subject to
the following two conditions:
(1) This device may not cause harmful interference, and (2) this device must
accept any interference received, including interference that may cause
undesired operation.
Any Changes or modifications not expressly approved by the party responsible
for compliance could void the user’s authority to operate the equipment.
Note: This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates uses and
can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment to an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help. The device has been evaluated to meet general RF exposure requirements.
The device can be used in portable exposure conditions without restriction.
Specific Absorption Rate (SAR) information:
This Smart Badge meets the government’s requirements for exposure to radio
waves. The guidelines are based on standards that were developed by
independent scientific organizations through periodic and thorough evaluations
of scientific studies. The standards include a substantial safety margin
designed to assure the safety of all persons regardless of age or health.
FCC RF Exposure Information and Statement
– This radio is designed for and classified as “General
population/uncontrolled Use”, the guidelines are based on standards that were
developed by independent scientific organizations through periodic and
thorough evaluation of scientific studies. The standards include a substantial
safety margin designed to assure the safety of all persons regardless of age
or health. The exposure standard for wireless radio employs a unit of
measurement known as the Specific Absorption Rate, or SAR, the
The SAR limit is set 1.6W/kg.
- Body-worn operation; this device was tested for typical body-worn operations with the back of the handset kept 0mm for body-worn. To maintain compliance with RF exposure requirements, use accessories that maintain a 0mm for body-worn. The use of belt clips, holsters, and similar accessories should not contain metallic components in its assembly. The use of accessories that do not satisfy these requirements may not comply with RF exposure requirements and should be avoided.
- The highest reported SAR value for worn on the body is 0.797 W/kg.
Specification
Positioning Mode | BLE/GNSS |
---|---|
Protocol | LoRaWAN |
Frequency | 902.3~914.9MHz |
Sensitivity | -130dBm@SF9, -123dBm@SF8, -115dBm@SF7 |
Operating Current | 17uA@sleep mode |
Max 102mA@20dBm
Standby Time| 6 months
Operating Temperature| -15~+45℃
Charging Temperature| -10~+40℃
Storage Temperature| -40~+85℃
Communication Distance| >1.5km in urban area
Product introduction
2.1 Function
BC02 is a card-type low-power locator product independently developed by our
company based on LoRaWAN technology. BLE technology is used indoors and GNSS
is used
outdoors for positioning and long-distance transmission via standard LoRaWAN.
The product has the following functions:
- Indoor location is based on BLE, cooperates with our company localization algorithm, provides a precision of 1 ~ 5 meters, and the probability of fewer than three meters is 70%.
- Outdoor location is based on GPS, with a precision of 10 meters, the probability of less than 10 meters is 80%.
- Support Quuppa system, based on the BLE AOA high precision positioning, precision is less than 1 m.
- 800 ma rechargeable lithium battery, supports overcharge and high-temperature protection, standby time can be up to 6 months.
- Bluetooth OTA upgrade supports batch updates.
- Support iBeacon protocol and third-party custom-defined BLE formats, support for up to five kinds of BLE custom formats.
- Beacon white list mechanism, scan only specific UUID beacon, support for up to five different UUID.
- Intelligent motion sensor enters a sleep state when stationary, and power consumption is less than 17uA.
- During specified times, such as night, the device can enter deep sleep, and power consumption is less than 5uA.
- Intelligent scanning to save power, don’t start BLE scanning if move steps under the threshold.
- Precise step counting, the error is less than 5%.
- Security Social distance monitoring, the device will sound or vibrate if people are too close, and the distance threshold is adjustable;
- Support SOS alarm, entering hazardous area alarm;
- Cooperate with our BLE gateway, badges can work in places without Lora signals, such as the cabin, and shielding room.
- Badge can also detect asset beacons to implement localization and asset management dual mode.
- Badge can be set as a BLE gateway, to detect and report at most 50 BLE beacons in one single transmission.
2.2 Size
2.3 Parameters
Type | BC02 |
---|---|
Frequency | 902.3~914.9MHz |
Tx Power | 17dBm +/-2dB |
Lora Protocol | LoRaWAN1.0.3 |
BLE | 2.4G Hz |
RSSI | -92dBm |
BLE Protocol | BLE 4.2, iBeacon |
Chip | Nordic NRF52832,Semtech LLCC68 |
Charge | MicroUSB,5V/250mA |
Battery | 800mah, 622452 Polymer lithium battery |
Sleep Current | 17uA |
Data Interval | Configurable, 10s by default |
Range | LoRa: >1000m, BLE: >50m |
Sensor | G-Sensor |
Upgrade | BLE OTA |
Alarm | SOS, hazardous area alarm |
Temperature | -15℃ ~ 60℃ |
Protection Grade | IP66 |
Size | 98mm x 60mm x 7.7~9.1mm(L x W x H) |
Weight | 50g |
Shell material | ABS |
Installation | Rope |
Operate guide
3.1 Charge
The charging port is a standard MicroUSB, which is used to charge regular
Android phones. When charging, the indicator is blinking red. After charging,
the indicator turns to be steady green. After removing the charging head, the
green indicator is off. The locator has a built-in battery management chip
that automatically terminates charging when the battery is fully charged. A
full battery takes about three hours.
3.2 Power on
The badge can be turned on by pressing the power button. To power on the
badge, need to press the button till the green LED is on and red LED blinks,
and the buzzer beeps. The badge can’t be turned off by pressing the button for
security reasons.
3.3 Power off
After startup, the worker card cannot be shut down by pressing the button, but
can only be shut down remotely by command. When receiving the shutdown
command, the buzzer will ring three times, and the red light will be on for
three seconds and then off.
3.4 SOS
Press the button three times in three seconds can trigger an SOS alarm. If the
alarm is generated successfully, the buzzer beep one time and the red LED
blinks. The server
needs to send an acknowledgment message after receiving the alarm, then the
red LED turns off and the green LED blinks, it tells the caller that the alarm
has been received. After that, the platform administrator needs to dismiss SOS
by downlink command; otherwise, the
green LED keeps flashing. The caller can also restart the device to deactivate
the alarm.
3.5 Reboot
under startup state, long press the button above three seconds, the LED light
will blink three times, and the buzzer will beep, then the device restart.
3.6 Status Check
Short press the button to check whether the tracker is working, if the green
LED blinks, it indicates the tracker is working and the left power of the
battery is above 70%. If both the green LED and red LED blink, the power is
above 40%. If only red LED blinks, the power is below 40%, needs to be charged
ASAP.
Configuration
The working parameters of the device can be configured online through the Lora network or through the Bluetooth connection established through the APP. In addition, if the device number, Key, frequency point, and working mode of the device are changed, they can only be changed through the APP. For details, please visit the following links:
https://location.rctiot.com:8079/guide/bleconfig.html
Upgrade
Devices can be upgraded by establishing a Bluetooth connection through the NRF Connect. The NRF Connect interface is slightly different between Android and Apple iPhones. For details on how to upgrade, please visit the following link:
https://location.rctiot.com:8079/guide/ota.html
Unpacking and checking
-
Check whether the number, instruction manual, certificate, packing list
and accessories of the packing case are complete. -
The appearance of the product should be intact and marked clearly.
Maintenance guide
-
The light does not respond when the device button is pressed?
In this case, the device may be powered off or hibernated in a low-power state. You can view the latest power of the device through the platform. -
How to extend the working time of the equipment
The sleep time of the device can be set through the platform, which does not consume power when it is not working。 -
Do I need to restart the device after it is shut down and charged at low power?
Don’t need it. The shutdown of the device due to low power is actually deep hibernation, and the device itself has a certain amount of power, which can automatically resume work after charging. -
The device is always in a static state, how to obtain its position?
You can obtain the current location by issuing the request location command from platform.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>