Laserliner 082.431A AirMonitor Pure Instruction Manual
- June 4, 2024
- Laserliner
Table of Contents
AirMonitor PURE
Instruction Manual
Safety instructions
Dealing with electromagnetic radiation
- The measuring device complies with the provisions and limits values for safety and electromagnetic compatibility in accordance with the Low Voltage Directive (LVD) 2014/35/EU and the Electromagnetic Compatibility (EMC) Directive 2014/30/EU.
- Umarex GmbH & Co KG hereby declares that the electronic device AirMonitor PURE complies with the requirements and other conditions of the European Low Voltage Directive 2014/35/EU (LVD) and the EMC Directive 2014/30/EU. The complete text of the EC declaration of conformity is available at the following internet address: https://laserliner.com
Local operating restrictions – for example, in hospitals, aircraft, petrol
stations or in the vicinity of people with pacemakers – may apply. Electronic
devices can potentially cause hazards or interference or be subject to hazards
or interference.
Operation with a power supply unit
The device is operated using the power supply unit provided.
- Fine particulate matter indicator PM 2.5
- Fine particulate matter indicator PM 10
- PM 2.5 value display
- PM 10 value display
- Acoustic alarm OFF
- Time display in 12/24 hour mode
- Temperature display: unit of measurement °C
- Humidity display
a Clock button for setting the time
b Night mode button for dimming the display at night
c Alarm button ON/OFF Hours button for switching between 12 and 24-hour
clock modes
d Power supply connection
Set time
- Hold down the ‘Clock’ button (a) for 3 seconds. Hours display flashes.
- To set the minutes, press the ‘clock’ button (a).
- To set hours/minutes, use the ’night mode’ (b) and ‘alarm’ (c) buttons.
Explanation PM 2.5 / PM 10
Fine particulate matter with a diameter of 2.5 microns and 10 microns are
considered to be the most dangerous atmospheric pollutant. PM 10 fine
particulate matter includes pollen and allergens from plants and flowers. PM
2.5 fine particulate matter includes industrial emissions which can penetrate
deep into the respiratory tract due to their extremely small size, causing
long-term damage to the lungs.
Fine particulate matter indicator
PM 2.5 | 0… <10 pg/m3 | 10…<25 pg/m3 | 25 pg/m3 |
---|---|---|---|
Colour | green | yellow | red |
Alarm | _ | _ | |
PM 10 | 0…<25 pg/m3 | 25…<50 pg/m3 | nO pg/m3 |
--- | --- | --- | --- |
Colour | green | yellow | red |
Alarm | _ | _ |
Information on maintenance and care
Clean all components with a damp cloth and do not use cleaning agents,
scouring agents, and solvents. Store the device in a clean and dry place.
Maintenance work may only be carried out by qualified maintenance personnel.
Maintenance is required if the device is damaged in any way, for example, if
the power cable or plug are damaged, there has been ingress of liquids or
foreign bodies into the device, if the device has been rained on or subjected
to moisture, if it is no longer functioning correctly, or has been dropped.
Technical data
(Subject to technical changes without notice. Rev22W03)
Variable| The concentration of particular matter PM2.5 / PM10 Ambient
Temperature, Humidity
---|---
Ambient temperature Measuring range Accuracy| -9.9°C … 50°C
± 1°C
Humidity
Measuring range (relative) Accuracy (absolute) Humidity (relative)| 1% …
99%
± 3% (30% … 70%)
± 5% (0% … 30%, 70% … 100%)
Fine particulate matter
Measuring range Accuracy
Fine particulate matter sensitivity:| PM2.5: 0 … 999 µg/m³
PM10: 0 … 999 µg/m³
PM2.5: 0 … 100 μg/m³ (± 10 μg/m³), 100 … 999 μg/m³ (± 10%)
PM10: 0 … 100 μg/m³ (± 25 μg/m³), 100 … 999 μg/m³ (± 25%)
PM2.5: 300 nm … 2.5 µm
PM10: 300 nm … 10 µm
Sensor type| Particulate Matter
Power supply| 5V/DC / 1A power supply
Operating conditions| 0°C … 40°C, max. humidity, 80% RH, no condensation, max.
working altitude 2000 m above sea level
Storage conditions| -10°C … 60°C, max. humidity, 80% rH, no condensation
Dimensions (W x H x D)| 90 x 91 x 33 mm
Weight| 152 g (without power supply unit)
EU directives and disposal
This device complies with all necessary standards for the free movement of
goods within the EU.
This product is an electric device and must be collected separately for
disposal according to the European Directive on waste electrical and
electronic equipment.
Further safety and supplementary notices at: https://laserliner.com
SERVICE
Umarex GmbH & Co. KG
– Laserliner – Möhnestraße 149, 59755 Arnsberg, Germany
Tel.: +49 2932 638-300,
Fax: +49 2932 638-333
info@laserliner.com
Umarex GmbH & Co. KG
Sonnenfeld 2
59757 Arnsberg, Germany
Tel.: +49 2932 638-300,
Fax: -333
www.laserliner.com
** Rev22W03**
Documents / Resources
|
Laserliner 082.431A AirMonitor
Pure
[pdf] Instruction Manual
082.431A AirMonitor Pure, 082.431A, AirMonitor Pure, Pure
---|---
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>